The ReconnectSupervisor was constructed but its trigger ReportTransportFailure was never called. When the gateway StreamEvents stream faulted, EventPump just logged and exited — the supervisor was never notified, so a transient gateway drop permanently stopped data-change notifications while GetHealth() still reported Healthy. EventPump gains an optional onStreamFault callback invoked from its stream-fault catch block (not on clean shutdown). GalaxyDriver wires it to ReconnectSupervisor.ReportTransportFailure so a transport drop drives reopen → replay. This is the minimal fix for -001; the pump-restart-on-reopen gap remains tracked as Driver.Galaxy-008. Regression tests cover the callback being invoked on fault, the end-to-end supervisor reopen/replay, and that a clean shutdown does not fire it. Driver.Galaxy suite: 206/206 pass. Resolves code-review finding Driver.Galaxy-001 (Critical). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>