Until now ISqlDialect.QuoteIdentifier was the SOLE defence for authored
table/column names: an identifier went from the TagConfig blob straight into a
command text, bracket-quoted. The residual risk was bounded — a hostile name is
quoted into one nonexistent object, the query fails after the connection opens,
and the tag Bad-codes — but "bounded" is not "filtered", and the design promised
a filter. Both ISqlDialect and SqlServerDialect carried a doc paragraph saying so.
SqlCatalogGate + SqlCatalogLoader now resolve every authored identifier against
the live catalog at Initialize, and REPLACE it with the catalog's own spelling.
The identifier text in an emitted poll query is therefore a string this driver
read back out of ListSchemas/ListTables/ListColumns — not operator input. Quoting
becomes the backstop it was documented to be.
Decisions worth knowing before touching this:
- Substitution, not just validation. Matching is exact-ordinal first, then a
UNIQUE case-insensitive hit: SQL Server's default collation is CI so case
variants have always worked, and rejecting them would break valid deployments.
An ambiguous CI match under a case-sensitive collation is refused rather than
guessed — picking one would publish another column's data under the operator's
node, which is worse than rejecting the tag.
- Charset check BEFORE catalog lookup. Each identifier goes through
QuoteIdentifier for its rejection rules first, so a name carrying a control or
Unicode format character is rejected WITHOUT its value being echoed into a log
line (Trojan-Source). A name that passes is safe to render, which is why
catalog-miss messages do name it — an operator hunting a typo has to see what
they wrote. Both halves are pinned by tests.
- A rejected tag keeps its node. It is dropped from the POLLED table but stays in
the AUTHORED table, so it still materializes and reads BadNodeIdUnknown —
§8.1's specified outcome. My first wiring dropped it from both, which deleted
the node instead; an existing test (ReinitializeAsync_recoversFromFaulted)
caught it. A status code can only be published by a node that exists, and a
missing address-space entry is far harder to diagnose than a Bad quality.
- An unreadable catalog FAULTS Initialize; it does not reject every tag. That is
the absence of evidence about the tags, not evidence against them — rejecting
all of them would serve a confidently-empty address space and send the operator
hunting typos that do not exist. Zero visible schemas is treated the same way,
because that is exactly what a missing GRANT looks like. Faulting lands
DriverInstanceActor in Reconnecting with its retry timer running.
- Bounded load: one schema list, one default-schema scalar, then one ListTables
per distinct authored schema and one ListColumns per distinct authored relation
— never a full catalog enumeration, and nothing after Initialize. Every
authored name reaches the catalog queries as a bound @schema/@table parameter,
so building the allow-list cannot itself be an injection vector.
- ISqlDialect gains DefaultSchemaSql ("SELECT SCHEMA_NAME()"). An unqualified
`TagValues` must resolve in whatever schema the SERVER reports; hardcoding dbo
would be a silent lie on any estate that maps service accounts to their own
default schema. It is a query, not a constant, because the answer is
per-connection.
- Accepted v1 limitation: a 3-part db.schema.table (or linked-server name)
addresses a catalog this connection cannot enumerate, so it cannot be
allow-listed and is rejected with a message pointing at the fix — expose the
data through a view in the connected database.
VerifyLivenessAsync's wall-clock pattern is extracted to RunBoundedAsync and
reused, so the new I/O gets the same R2-01 / STAB-14 protection rather than a
second hand-rolled copy. (It also fixes a latent bug in the extracted code: the
OperationCanceledException arm detached the wrong task.)
Tests: 24 pure gate tests + 9 end-to-end driver tests against the real SQLite
catalog + 3 new live tests against the real SQL Server on 10.100.0.35 (21 in that
suite now pass, exercising the real SELECT SCHEMA_NAME() + INFORMATION_SCHEMA
path). Verified falsifiable: bypassing the gate turns exactly the three rejection
assertions red and leaves the rest green.
SqlInjectionRegressionTests is deliberately NOT rewritten to expect
BadNodeIdUnknown. It drives SqlPollReader directly, below the gate, and pins the
quoting backstop on its own — defence in depth is only worth the name if each
layer holds independently. Rewriting those assertions would delete the backstop's
only coverage and leave the gate a single point of failure. Its scope note, which
said the gate does not exist, is updated to say why it stays where it is.
OtOpcUa
OPC UA server (.NET 10 AnyCPU) that exposes a fleet of industrial drivers as a single OPC UA address space. Drivers ship in-process for AVEVA System Platform Galaxy (via the sibling mxaccessgw repo), Modbus TCP, Siemens S7, Allen-Bradley CIP (ControlLogix / CompactLogix), Allen-Bradley Legacy (SLC 500 / MicroLogix), Beckhoff TwinCAT (ADS), FANUC FOCAS, and OPC UA Client (gateway).
A cross-platform client stack (.NET 10) — shared library, CLI, and Avalonia desktop app — connects to any OPC UA server.
Architecture
OPC UA Clients (CLI, Desktop UI, 3rd-party)
|
v
+-------------------------------------+
| OtOpcUa.Server (.NET 10 AnyCPU) |
| address space + capability fan-out|
+-------------------------------------+
| | | | | | | |
Galaxy Modbus S7 AbCip AbLeg TwinCAT FOCAS OpcUaClient
|
v
mxaccessgw (sibling repo, gRPC)
|
v
MXAccess COM (x86 worker, on AVEVA box)
Galaxy is the only driver with an external runtime: it speaks gRPC to a separately installed mxaccessgw server (sibling repo at c:\Users\dohertj2\Desktop\mxaccessgw\) which owns the MXAccess COM apartment and the x86/STA bitness constraint server-side. Everything in this repo is platform-agnostic .NET 10.
Prerequisites
- .NET 10 SDK (server, drivers, clients all target .NET 10)
- SQL Server reachable for the central config DB
- For Galaxy specifically: a running
mxaccessgwdeployment — see docs/v2/Galaxy.ParityRig.md - For historian read-back / alarm history / continuous historization: a running
ZB.MOM.WW.HistorianGatewaydeployment (the sole historian backend; consumed as theZB.MOM.WW.HistorianGateway.ClientgRPC package). It must runRuntimeDb:Enabled=true+RuntimeDb:EventReadsEnabled=true, and the API key must carryhistorian:read+historian:write+historian:tags:writescopes.
Quick Start
dotnet restore ZB.MOM.WW.OtOpcUa.slnx
dotnet build ZB.MOM.WW.OtOpcUa.slnx
dotnet test ZB.MOM.WW.OtOpcUa.slnx
# Run the server in dev (foreground)
dotnet run --project src/Server/ZB.MOM.WW.OtOpcUa.Host
The server starts on opc.tcp://localhost:4840 with the None security profile. Configure Security.Profiles in src/Server/ZB.MOM.WW.OtOpcUa.Host/appsettings.json to enable Basic256Sha256-Sign or Basic256Sha256-SignAndEncrypt. See docs/security.md.
Install as Windows Services
Production deployment is driven by scripts/install/Install-Services.ps1, which registers the OtOpcUa server service under a chosen service account. Historian support requires a separately deployed ZB.MOM.WW.HistorianGateway and Galaxy support a separately installed mxaccessgw — neither this repo nor the install script provisions them.
.\scripts\install\Install-Services.ps1 `
-InstallRoot 'C:\Program Files\OtOpcUa' `
-ServiceAccount 'DOMAIN\svc-otopcua'
The historian backend is the external ZB.MOM.WW.HistorianGateway (not installed by this script). See the script header and docs/ServiceHosting.md for full options.
Client CLI
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- connect -u opc.tcp://localhost:4840
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- browse -u opc.tcp://localhost:4840 -r -d 3
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- read -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode"
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- write -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -v 42
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- subscribe -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -i 500
See docs/Client.CLI.md and docs/Client.UI.md.
Documentation
Architecture deep-dives
| Topic | Doc |
|---|---|
| OPC UA server composition, namespace fan-out, Polly invoker | docs/OpcUaServer.md |
| Address space layout | docs/AddressSpace.md |
| Read / Write dispatch (driver vs virtual vs scripted-alarm) | docs/ReadWriteOperations.md |
| Incremental sync (driver-backend rediscovery + config publishes) | docs/IncrementalSync.md |
| Service hosting (Server + Admin; external HistorianGateway backend) | docs/ServiceHosting.md |
| Security (transport, LDAP, certificates) | docs/security.md |
| Redundancy | docs/Redundancy.md |
| Status dashboard | docs/StatusDashboard.md |
Drivers
| Topic | Doc |
|---|---|
| Driver specs (per-driver capability surface, config, addressing) | docs/v2/driver-specs.md |
| Galaxy driver | docs/drivers/Galaxy.md |
| Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient | docs/drivers/ |
| Galaxy parity rig (mxaccessgw setup) | docs/v2/Galaxy.ParityRig.md |
| Galaxy performance + tracing | docs/v2/Galaxy.Performance.md |
Clients
| Topic | Doc |
|---|---|
| Client CLI | docs/Client.CLI.md |
| Client UI (Avalonia desktop) | docs/Client.UI.md |
v1 archive
The original v1 in-process MXAccess docs (Galaxy.Host topology, Configuration env vars, AlarmTracking, DataTypeMapping, HistoricalDataAccess, Subscriptions, etc.) are preserved under docs/v1/ — historical reference only. PR 7.2 retired the v1 architecture on 2026-04-30; current state is documented in the sections above.
License
Internal use only.