# S7 integration-test fixture — python-snap7
|
||
|
||
[python-snap7](https://github.com/gijzelaerr/python-snap7) `Server` class
|
||
wrapped in a pinned `python:3.12-slim-bookworm` image. Docker is the
|
||
only supported launch path — a fresh clone needs Docker Desktop and
|
||
nothing else.
|
||
|
||
| File | Purpose |
|
||
|---|---|
|
||
| [`Dockerfile`](Dockerfile) | `python:3.12-slim-bookworm` + `python-snap7>=2.0` + the server shim + the profile JSONs |
|
||
| [`docker-compose.yml`](docker-compose.yml) | One service per profile; currently only `s7_1500` |
|
||
| [`server.py`](server.py) | Same Python shim the native fallback uses — copy kept in the build context |
|
||
| [`profiles/*.json`](profiles/) | Area-seed definitions (DB1 / MB layouts with typed seeds) |
|
||
|
||
## Run
|
||
|
||
From the repo root:
|
||
|
||
```powershell
|
||
docker compose -f tests\Drivers\ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests\Docker\docker-compose.yml --profile s7_1500 up
|
||
```
|
||
|
||
Detached + stop:
|
||
|
||
```powershell
|
||
docker compose -f tests\...\Docker\docker-compose.yml --profile s7_1500 up -d
|
||
docker compose -f tests\...\Docker\docker-compose.yml --profile s7_1500 down
|
||
```
|
||
|
||
### ⚠️ Editing a profile requires `--build`
|
||
|
||
`Dockerfile` **COPYs `profiles/` into the image**, so the seeds are baked in at
|
||
build time — they are not bind-mounted. A plain `up -d`, and even
|
||
`up -d --force-recreate`, reuses the existing `otopcua-python-snap7:1.0` image
|
||
and silently keeps serving the OLD seeds. After editing a profile JSON:
|
||
|
||
```bash
|
||
docker compose --profile s7_1500 up -d --build --force-recreate
|
||
```
|
||
|
||
Confirm it took: `docker logs otopcua-python-snap7-s7_1500` prints
|
||
`seeded DB1 size=1024 seeds=<n>` at startup — check `<n>` matches the seed count
|
||
you just wrote. This is the fastest way to tell a stale image from a bad address.
|
||
|
||
On the shared Docker host the deployment mirror at `/opt/otopcua-s7/` is
|
||
**root-owned**, so a plain `rsync` fails with `status 23` and leaves the old
|
||
files in place while still printing the file list. Push with:
|
||
|
||
```bash
|
||
rsync -av --rsync-path="sudo rsync" \
|
||
tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/Docker/ \
|
||
dohertj2@10.100.0.35:/opt/otopcua-s7/
|
||
```
|
||
|
||
## Endpoint
|
||
|
||
- Default: `localhost:1102` (non-privileged; sidesteps Windows Firewall
|
||
prompt + Linux's root-required bind on port 102).
|
||
- Override with `S7_SIM_ENDPOINT` to point at a real S7 CPU on `:102`.
|
||
- The driver's S7DriverOptions.Port flows through S7netplus's 5-arg
|
||
`Plc(CpuType, host, port, rack, slot)` ctor so the non-standard port
|
||
works end-to-end.
|
||
|
||
## Run the integration tests
|
||
|
||
In a separate shell with the container up:
|
||
|
||
```powershell
|
||
cd C:\Users\dohertj2\Desktop\lmxopcua
|
||
dotnet test tests\Drivers\ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests
|
||
```
|
||
|
||
`Snap7ServerFixture` probes `localhost:1102` at collection init + records
|
||
a `SkipReason` when unreachable, so tests stay green on a fresh clone
|
||
without Docker running.
|
||
|
||
## What's encoded in `profiles/s7_1500.json`
|
||
|
||
DB1 (1024 bytes) + MB (256 bytes) + TM0/CT0 (64 bytes each) with typed seeds at
|
||
known offsets:
|
||
|
||
| Address | Type | Seed | Purpose |
|
||
|---|---|---|---|
|
||
| `DB1.DBW0` | u16 | `4242` | read-back probe |
|
||
| `DB1.DBW10` | i16 | `-12345` | smoke i16 read |
|
||
| `DB1.DBD20` | i32 | `1234567890` | smoke i32 read |
|
||
| `DB1.DBD30` | f32 | `3.14159` | smoke f32 read (big-endian) |
|
||
| `DB1.DBX50.3` | bool | `true` | smoke bool read at bit 3 |
|
||
| `DB1.DBW100` | u16 | `0` | scratch for write-then-read |
|
||
| `DB1.STRING[200]` | S7 STRING | `"Hello"` | S7 STRING read |
|
||
| `MW0` | u16 | `1` | `S7ProbeOptions.ProbeAddress` default |
|
||
|
||
Seed types supported: `u8`, `i8`, `u16`, `i16`, `u32`, `i32`, `f32`,
|
||
`bool` (with `"bit": 0..7`), `ascii` (S7 STRING).
|
||
|
||
### Span-planner gate seeds (offsets 300+, `S7_1500SpanReadTests`)
|
||
|
||
These exist to give `S7ReadSpanPlanner` a layout with a **known** partition under
|
||
the shipped 16-byte-gap / 220-byte-span defaults — the offsets are the test, so
|
||
moving one changes what the gate proves.
|
||
|
||
| Address | Type | Seed | Role in the partition |
|
||
|---|---|---|---|
|
||
| `DB1.DBW300` | u16 | `51001` | cluster A — merges with the four below into ONE 300..320 span |
|
||
| `DB1.DBW302` | i16 | `-21001` | cluster A (gap 0) |
|
||
| `DB1.DBD304` | i32 | `305419896` | cluster A (gap 0) |
|
||
| `DB1.DBX310.5` | bool | `true` | cluster A (gap 2) |
|
||
| `DB1.DBD316` | f32 | `2.7182817` | cluster A (gap 5); seals the span at 20 bytes |
|
||
| `DB1.DBW400` | u16 | `40201` | cluster B — 80 bytes on, so the gap budget forces a SECOND span |
|
||
| `DB1.DBW402` | u16 | `40202` | cluster B's second member (keeps it off the `PrefersPerTagRead` demotion) |
|
||
| `DB1.DBW500` | u16 | `60001` | isolated ⇒ demoted single-member span ⇒ multi-var leftover |
|
||
| `DB1.DBW600` | i16 | `-32001` | isolated ⇒ multi-var leftover |
|
||
| `MW10` | u16 | `4097` | multi-var leftover in a **different area** — a block read can't cross `(area, DB)`, multi-var can |
|
||
|
||
Offsets `308`, `311` and `312` carry **poison** (`0xDEAD`, `0x5A`, `0xDEADBEEF`)
|
||
inside the holes cluster A's span reads through. No tag maps to them; they are
|
||
there so a mis-computed slice offset returns garbage instead of a zero that could
|
||
match by luck. Every seed above is distinct and non-zero for the same reason.
|
||
|
||
### Timer / Counter (TM / CT) areas
|
||
|
||
`TM0` and `CT0` are 64 bytes each — **32 device cells**, since a timer is a 2-byte
|
||
S5TIME word and a counter a 2-byte count word, with device number `N` at byte
|
||
offset `2 × N`. They exist so `S7_1500SpanReadTests` can pin, against real wire,
|
||
that `S7ReadSpanPlanner` excludes Timer/Counter from every span and the multi-var
|
||
pass excludes them again on `IsBufferType` — each takes its own area-typed
|
||
`ReadBytes` round-trip instead.
|
||
|
||
| Address | Byte offset | Seed | Decodes to |
|
||
|---|---|---|---|
|
||
| `T0` | 0 | `0x2456` | `456.0` s (S5TIME base 2 = ×1 s, BCD 456) |
|
||
| `T5` | 10 | `0x1123` | `12.3` s (base 1 = ×0.1 s, BCD 123) |
|
||
| `T9` | 18 | `0x0250` | `2.5` s (base 0 = ×0.01 s, BCD 250) |
|
||
| `C0` | 0 | `4711` | `4711` (raw big-endian count word) |
|
||
| `C7` | 14 | `31337` | `31337` |
|
||
| `C11` | 22 | `1234` | `1234` |
|
||
|
||
A timer decodes to seconds as a `double` (S7.Net `Timer.FromByteArray`) and a
|
||
counter to an `int` count (`Counter.FromByteArray`, raw word — **not** BCD).
|
||
|
||
#### ⚠️ Only device **0** is addressable on this fixture
|
||
|
||
Live-probed 2026-08-17: snap7's server resolves the TM/CT request address as a
|
||
**bit address** — it serves byte `addr >> 3` of the area — whereas S7.Net, and a
|
||
real S7 CPU, put the device **number** in that field. Measured with S7netplus
|
||
0.20.0 against `10.100.0.35:1102` running **the profile above**:
|
||
|
||
```
|
||
ReadBytes(Timer,db=0,start=0,count=8) => [24 56 00 00 00 00 00 00] # TM bytes 0..7: T0 = 0x2456
|
||
ReadBytes(Timer,db=0,start=0,count=2) => [24 56] # T0 -> byte 0. 0>>3 == 2*0, so BOTH conventions agree here
|
||
ReadBytes(Timer,db=0,start=5,count=2) => [24 56] # T5 -> 5>>3 = byte 0. WRONG cell: T5 lives at bytes 10..11 (0x1123)
|
||
ReadBytes(Timer,db=0,start=80,count=2) => [11 23] # byte 10 needs start 80 (= 10*8): the T5 cell, reached the bit-address way
|
||
ReadBytes(Counter,db=0,start=0,count=2) => [12 67] # C0 -> byte 0 = 4711. Both conventions agree
|
||
ReadBytes(Counter,db=0,start=7,count=2) => [12 67] # C7 -> 7>>3 = byte 0. WRONG cell: C7 lives at bytes 14..15 (0x7A69 = 31337)
|
||
ReadBytes(Counter,db=0,start=112,count=2) => [7A 69] # byte 14 needs start 112 (= 14*8): the C7 cell
|
||
```
|
||
|
||
Note lines 2 and 3: asking for `T0` and asking for `T5` return the **same bytes**
|
||
— every device 0..7 collapses onto TM byte 0. Same for `C0` / `C7`.
|
||
|
||
No error is raised — the reads succeed, they just land on the wrong cell. Device
|
||
**0** is the single fixed point of the two conventions (`0 >> 3 == 2 × 0 == 0`),
|
||
so `T0` / `C0` are the only cells whose *value* the fixture can pin; that is what
|
||
`Timer_and_counter_tags_never_enter_a_multi_var_request` asserts, and the
|
||
wire-shape half of that test is unaffected by the quirk. The `2 × N` cells above
|
||
are seeded for a real CPU: run
|
||
`Timer_and_counter_decode_the_seeded_values_at_their_device_numbers` against one
|
||
with
|
||
|
||
```bash
|
||
S7_SIM_ENDPOINT=<cpu>:102 S7_TIMER_NUMBER_ADDRESSING=1 \
|
||
dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests
|
||
```
|
||
|
||
It skips (naming this limitation) whenever that variable is unset.
|
||
|
||
## Known limitations
|
||
|
||
From the `snap7.server.Server` docstring upstream:
|
||
|
||
> "Legacy S7 server implementation. Emulates a Siemens S7 PLC for testing
|
||
> and development purposes. [...] pure Python emulator implementation that
|
||
> simulates PLC behaviour for protocol compliance testing rather than
|
||
> full industrial-grade functionality."
|
||
|
||
Not exercised here — needs a lab rig:
|
||
|
||
- S7-1500 Optimized-DB symbolic access
|
||
- PG / OP / S7-Basic session-type differentiation
|
||
- PUT/GET-disabled-by-default enforcement
|
||
- Device-number addressing of the TM / CT areas (see the ⚠️ above — the reads are
|
||
served, but resolved as bit addresses, so only device 0 lands where a CPU
|
||
would put it)
|
||
|
||
See [`docs/drivers/S7-Test-Fixture.md`](../../../docs/drivers/S7-Test-Fixture.md)
|
||
for the full coverage map.
|
||
|
||
## References
|
||
|
||
- [python-snap7 GitHub](https://github.com/gijzelaerr/python-snap7)
|
||
- [`docs/drivers/S7-Test-Fixture.md`](../../../docs/drivers/S7-Test-Fixture.md) — coverage map
|
||
- [`docs/v2/dev-environment.md`](../../../docs/v2/dev-environment.md) §Docker fixtures
|