Joseph Doherty f3850f8914 Phase 6.1 Stream A.5/A.6 — WriteIdempotent flag on DriverAttributeInfo + Modbus/S7 tag records + FlakeyDriver integration tests
Per-tag opt-in for write-retry per docs/v2/plan.md decisions #44, #45, #143.
Default is false — writes never auto-retry unless the driver author has marked
the tag as safe to replay.

Core.Abstractions:
- DriverAttributeInfo gains `bool WriteIdempotent = false` at the end of the
  positional record (back-compatible; every existing call site uses the default).

Driver.Modbus:
- ModbusTagDefinition gains `bool WriteIdempotent = false`. Safe candidates
  documented in the param XML: holding-register set-points, configuration
  registers. Unsafe: edge-triggered coils, counter-increment addresses.
- ModbusDriver.DiscoverAsync propagates t.WriteIdempotent into
  DriverAttributeInfo.WriteIdempotent.

Driver.S7:
- S7TagDefinition gains `bool WriteIdempotent = false`. Safe candidates:
  DB word/dword set-points, configuration DBs. Unsafe: M/Q bits that drive
  edge-triggered program routines.
- S7Driver.DiscoverAsync propagates the flag.

Stream A.5 integration tests (FlakeyDriverIntegrationTests, 4 new) exercise
the invoker + flaky-driver contract the plan enumerates:
- Read with 5 transient failures succeeds on the 6th attempt (RetryCount=10).
- Non-idempotent write with RetryCount=5 configured still fails on the first
  failure — no replay (decision #44 guard at the ExecuteWriteAsync surface).
- Idempotent write with 2 transient failures succeeds on the 3rd attempt.
- Two hosts on the same driver have independent breakers — dead-host trips
  its breaker but live-host's first call still succeeds.

Propagation tests:
- ModbusDriverTests: SetPoint WriteIdempotent=true flows into
  DriverAttributeInfo; PulseCoil default=false.
- S7DiscoveryAndSubscribeTests: same pattern for DBx SetPoint vs M-bit.

Full solution dotnet test: 947 passing (baseline 906, +41 net across Stream A
so far). Pre-existing Client.CLI Subscribe flake unchanged.

Stream A's remaining work (wiring CapabilityInvoker into DriverNodeManager's
OnReadValue / OnWriteValue / History / Subscribe dispatch paths) is the
server-side integration piece + needs DI wiring for the pipeline builder —
lands in the next PR on this branch.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 07:16:21 -04:00
..
Phase 3 PR 63 -- S7AddressParser for DB/M/I/Q/T/C address strings. Adds S7AddressParser + S7ParsedAddress + S7Area + S7Size to the Driver.S7 project. Grammar follows driver-specs.md \u00A75 + Siemens TIA Portal / STEP 7 Classic convention: (1) Data blocks: DB{n}.DB{X|B|W|D}{offset}[.bit] where X=bit (requires .bit suffix 0-7), B=byte, W=word (16-bit), D=dword (32-bit). (2) Merkers: MB{n}, MW{n}, MD{n}, or M{n}.{bit} for bit access. (3) Inputs + Outputs: same {B|W|D} prefix or {n}.{bit} pattern as M. (4) Timers: T{n}. (5) Counters: C{n}. Output is an immutable S7ParsedAddress record struct with Area (DataBlock / Memory / Input / Output / Timer / Counter), DbNumber (only meaningful for DataBlock), Size (Bit / Byte / Word / DWord), ByteOffset (also timer/counter number when Area is Timer/Counter), BitOffset (0-7 for Size=Bit; 0 otherwise). Case-insensitive via ToUpperInvariant, whitespace trimmed on entry. Parse throws FormatException with the offending input echoed in the message; TryParse returns bool for config-validation callers that can't afford exceptions (e.g. Admin UI tag-editor live validation). Strict rejection policy -- 16 garbage cases covered in the theory test: empty/whitespace input, unknown area letter (Z0), DB without number/tail, DB bit size without .bit suffix, bit offset 8+, word/dword with .bit suffix, DB number 0 (must be >=1), non-numeric DB number, unknown size letter (Q), M without offset, M bit access without .bit, bit 8, negative offset, non-digit offset, non-numeric timer. Strict rejection surfaces config errors at driver-init time rather than as BadInternalError on every Read against the bad tag. No driver code wires through yet -- PR 64 is where IReadable/IWritable consume S7ParsedAddress and translate into S7netplus Plc.ReadAsync calls (the S7.Net address grammar is a strict subset of what we accept, and the parser's S7ParsedAddress is the bridge). Unit tests (S7AddressParserTests, 50 facts): parse-valid theories for DB/M/I/Q/T/C covering all size variants + edge bit offsets 0 and 7; case-insensitive + whitespace-trim theory; reject-invalid theory with 16 garbage cases; TryParse round-trip for valid and invalid inputs. 50/50 pass, dotnet build clean.
2026-04-19 00:06:24 -04:00
Phase 3 PR 64 -- S7 IReadable + IWritable via S7.Net string-based Plc.ReadAsync/WriteAsync. Adds IReadable + IWritable capability interfaces to S7Driver, routing reads/writes through S7netplus's string-address API (Plc.ReadAsync(string, ct) / Plc.WriteAsync(string, object, ct)). All operations serialize on the class's SemaphoreSlim Gate because S7netplus mandates one Plc connection per PLC with client-side serialization -- parallel reads against a single S7 CPU queue wire-side anyway and just eat connection-resource budget. Supported data types in this PR: Bool, Byte, Int16, UInt16, Int32, UInt32, Float32. S7.Net's string-based read returns UNSIGNED boxed values (DBX=bool, DBB=byte, DBW=ushort, DBD=uint); the driver reinterprets them into the requested S7DataType via the (DataType, Size, raw) switch: unchecked short-cast for Int16, unchecked int-cast for Int32, BitConverter.UInt32BitsToSingle for Float32. Writes inverse the conversion -- Int16 -> unchecked ushort cast, Int32 -> unchecked uint cast, Float32 -> BitConverter.SingleToUInt32Bits -- before handing to S7.Net's WriteAsync. This avoids a second PLC round-trip that a typed ReadAsync(DataType, db, offset, VarType, ...) overload would need. Int64, UInt64, Float64, String, DateTime throw NotSupportedException (-> BadNotSupported StatusCode); S7 STRING has non-trivial header semantics + LReal/DateTime need typed S7.Net API paths, both land in a follow-up PR when scope demands. InitializeAsync now parses every tag's Address string via S7AddressParser at init time. Bad addresses throw FormatException and flip health to Faulted -- callers can't register a broken driver. The parsed form goes into _parsedByName so Read/Write can consult Size/BitOffset without re-parsing per operation. StatusCode mapping in catch chain: unknown tag name -> BadNodeIdUnknown (0x80340000), unsupported data type -> BadNotSupported (0x803D0000), read-only tag write attempt -> BadNotWritable (0x803B0000), S7.Net PlcException (carries PUT/GET-disabled signal on S7-1200/1500) -> BadDeviceFailure (0x80550000) so operators see a TIA-Portal config problem rather than a transient-fault false flag per driver-specs.md \u00A75, any other runtime exception on read -> BadCommunicationError (0x80050000) to distinguish socket/timeout from tag-level faults. Write generic-exception path stays BadInternalError because write failures can legitimately be driver-side value-range problems. Unit tests (S7DriverReadWriteTests, 3 facts): Initialize_rejects_invalid_tag_address_and_fails_fast -- Tags with a malformed address must throw at InitializeAsync rather than producing a half-healthy driver; ReadAsync_without_initialize_throws_InvalidOperationException + WriteAsync_without_initialize_throws_InvalidOperationException -- pre-init calls hit RequirePlc and throw the uniform 'not initialized' message. Wire-level round-trip coverage (integration test against a live S7-1500 or a mock S7 server) is deferred -- S7.Net doesn't ship an in-process fake and a conformant mock is non-trivial. 53/53 Modbus.Driver.S7.Tests pass (50 parser + 3 read/write). dotnet build clean.
2026-04-19 00:10:41 -04:00
Phase 3 PR 62 -- Siemens S7 native driver project scaffold (S7comm via S7netplus). First non-Modbus in-process driver. Creates src/ZB.MOM.WW.OtOpcUa.Driver.S7 (.NET 10, x64 -- S7netplus is managed, no bitness constraint like MXAccess) + tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests + slnx entries. Depends on S7netplus 0.20.0 which is the latest version on NuGet resolvable in this cache (0.21.0 per driver-specs.md is not yet published; 0.20.0 covers the same Plc+CpuType+ReadAsync surface). S7DriverOptions captures the connection settings documented in driver-specs.md \u00A75: Host, Port (default 102 ISO-on-TCP), CpuType (default S71500 per most-common deployment), Rack=0, Slot=0 (S7-1200/1500 onboard PN convention; S7-300/400 operators must override to slot 2 or 3), Timeout=5s, Tags list + Probe settings with default MW0 probe address. S7TagDefinition uses S7.Net-style address strings (DB1.DBW0, M0.0, I0.0, QD4) with an S7DataType enum (Bool, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float32, Float64, String, DateTime -- the full type matrix from the spec); StringLength defaults to 254 (S7 STRING max). S7Driver implements the IDriver-only subset per the PR plan: InitializeAsync opens a managed Plc with the configured CpuType + Host + Rack + Slot, pins WriteTimeout / ReadTimeout on the underlying TcpClient, awaits Plc.OpenAsync with a linked CTS bounded by Options.Timeout so the ISO handshake itself respects the configured bound; health transitions Unknown -> Initializing -> Healthy on success or Unknown -> Initializing -> Faulted on handshake failure, with a best-effort Plc.Close() on the faulted path so retries don't leak the TcpClient. ShutdownAsync closes the Plc and flips health back to Unknown. DisposeAsync routes through ShutdownAsync + disposes the SemaphoreSlim. Internal Gate + Plc accessors are exposed to the test project (InternalsVisibleTo) so PRs 63-65 can stack read/write/subscribe on the same serialization semaphore per the S7netplus documented 'one Plc per PLC, SemaphoreSlim-serialized' pattern. ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe are all deliberately omitted from this PR -- they depend on the S7AddressParser (PR 63) and land sequenced in PRs 64-65. Unit tests (S7DriverScaffoldTests, 5 facts): default options target S7-1500 / port 102 / slot 0, default probe interval 5s, tag defaults to writable with StringLength 254, driver reports DriverType=S7 + Unknown health pre-init, Initialize against RFC-5737 reserved IP 192.0.2.1 with 250ms timeout transitions to Faulted and throws (tests the connect-failure path doesn't leave the driver in an ambiguous state). 5/5 pass. dotnet build ZB.MOM.WW.OtOpcUa.slnx: 0 errors. No regression in Modbus / Galaxy suites. PR 63 ships S7AddressParser next, PR 64 wires IReadable/IWritable over S7netplus, PR 65 adds discovery + polling-overlay subscribe + probe.
2026-04-19 00:03:09 -04:00
Phase 3 PR 62 -- Siemens S7 native driver project scaffold (S7comm via S7netplus). First non-Modbus in-process driver. Creates src/ZB.MOM.WW.OtOpcUa.Driver.S7 (.NET 10, x64 -- S7netplus is managed, no bitness constraint like MXAccess) + tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests + slnx entries. Depends on S7netplus 0.20.0 which is the latest version on NuGet resolvable in this cache (0.21.0 per driver-specs.md is not yet published; 0.20.0 covers the same Plc+CpuType+ReadAsync surface). S7DriverOptions captures the connection settings documented in driver-specs.md \u00A75: Host, Port (default 102 ISO-on-TCP), CpuType (default S71500 per most-common deployment), Rack=0, Slot=0 (S7-1200/1500 onboard PN convention; S7-300/400 operators must override to slot 2 or 3), Timeout=5s, Tags list + Probe settings with default MW0 probe address. S7TagDefinition uses S7.Net-style address strings (DB1.DBW0, M0.0, I0.0, QD4) with an S7DataType enum (Bool, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float32, Float64, String, DateTime -- the full type matrix from the spec); StringLength defaults to 254 (S7 STRING max). S7Driver implements the IDriver-only subset per the PR plan: InitializeAsync opens a managed Plc with the configured CpuType + Host + Rack + Slot, pins WriteTimeout / ReadTimeout on the underlying TcpClient, awaits Plc.OpenAsync with a linked CTS bounded by Options.Timeout so the ISO handshake itself respects the configured bound; health transitions Unknown -> Initializing -> Healthy on success or Unknown -> Initializing -> Faulted on handshake failure, with a best-effort Plc.Close() on the faulted path so retries don't leak the TcpClient. ShutdownAsync closes the Plc and flips health back to Unknown. DisposeAsync routes through ShutdownAsync + disposes the SemaphoreSlim. Internal Gate + Plc accessors are exposed to the test project (InternalsVisibleTo) so PRs 63-65 can stack read/write/subscribe on the same serialization semaphore per the S7netplus documented 'one Plc per PLC, SemaphoreSlim-serialized' pattern. ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe are all deliberately omitted from this PR -- they depend on the S7AddressParser (PR 63) and land sequenced in PRs 64-65. Unit tests (S7DriverScaffoldTests, 5 facts): default options target S7-1500 / port 102 / slot 0, default probe interval 5s, tag defaults to writable with StringLength 254, driver reports DriverType=S7 + Unknown health pre-init, Initialize against RFC-5737 reserved IP 192.0.2.1 with 250ms timeout transitions to Faulted and throws (tests the connect-failure path doesn't leave the driver in an ambiguous state). 5/5 pass. dotnet build ZB.MOM.WW.OtOpcUa.slnx: 0 errors. No regression in Modbus / Galaxy suites. PR 63 ships S7AddressParser next, PR 64 wires IReadable/IWritable over S7netplus, PR 65 adds discovery + polling-overlay subscribe + probe.
2026-04-19 00:03:09 -04:00