Re-review at 7286d320. S7-015 (Medium): a Writable array tag had no WriteArrayAsync path
and silently returned BadCommunicationError on write; now rejected at init with a clear
NotSupportedException (read-only arrays still accepted) + TDD. S7-016 (factory JSON can't
produce array tags; needs AdminUI DTO) deferred.
498 lines
26 KiB
Markdown
498 lines
26 KiB
Markdown
# Code Review — Driver.S7
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Module | `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7` |
|
||
| Reviewer | Claude Code |
|
||
| Review date | 2026-06-19 |
|
||
| Commit reviewed | `7286d320` |
|
||
| Status | Reviewed |
|
||
| Open findings | 0 |
|
||
|
||
## Checklist coverage
|
||
|
||
A comprehensive review completes every category, recording "No issues found" where
|
||
a category produced nothing rather than leaving it blank.
|
||
|
||
| # | Category | Result |
|
||
|---|---|---|
|
||
| 1 | Correctness & logic bugs | Driver.S7-001, Driver.S7-002, Driver.S7-003 |
|
||
| 2 | OtOpcUa conventions | Driver.S7-004, Driver.S7-005 |
|
||
| 3 | Concurrency & thread safety | Driver.S7-006 |
|
||
| 4 | Error handling & resilience | Driver.S7-007, Driver.S7-008, Driver.S7-009 |
|
||
| 5 | Security | No issues found |
|
||
| 6 | Performance & resource management | Driver.S7-010 |
|
||
| 7 | Design-document adherence | Driver.S7-011, Driver.S7-012 |
|
||
| 8 | Code organization & conventions | Driver.S7-013 |
|
||
| 9 | Testing coverage | Driver.S7-014 |
|
||
| 10 | Documentation & comments | Driver.S7-012 (shared) |
|
||
|
||
## Re-review 2026-06-19 (commit 7286d320)
|
||
|
||
| # | Category | Result |
|
||
|---|---|---|
|
||
| 1 | Correctness & logic bugs | Driver.S7-015 |
|
||
| 2 | OtOpcUa conventions | No issues found |
|
||
| 3 | Concurrency & thread safety | No issues found |
|
||
| 4 | Error handling & resilience | No issues found |
|
||
| 5 | Security | No issues found |
|
||
| 6 | Performance & resource management | No issues found |
|
||
| 7 | Design-document adherence | Driver.S7-016 |
|
||
| 8 | Code organization & conventions | No issues found |
|
||
| 9 | Testing coverage | No issues found |
|
||
| 10 | Documentation & comments | No issues found |
|
||
|
||
## Findings
|
||
|
||
### Driver.S7-001
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | High |
|
||
| Category | Correctness & logic bugs |
|
||
| Location | `S7AddressParser.cs:93`, `S7Driver.cs:231` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** S7AddressParser.Parse accepts Timer (T0) and Counter (C0)
|
||
addresses and the test suite asserts they parse successfully, but the read path
|
||
cannot serve them. Two problems compound: (1) ReadOneAsync type-mapping switch
|
||
(lines 231-250) has no case for any Timer/Counter combination, so a Timer/Counter
|
||
tag falls through to the default arm and throws InvalidDataException with a
|
||
misleading "type-mismatch" message on every read; (2) the read is issued via
|
||
plc.ReadAsync(tag.Address, ...) passing the raw address string, and S7.Net
|
||
string-based parser does not understand T{n}/C{n} syntax. A tag configured with a
|
||
timer or counter address passes init-time parsing (the docstring promises config
|
||
typos fail fast at init) and then fails on every read - exactly the
|
||
un-diagnosable failure mode the fail-fast parse was meant to prevent.
|
||
|
||
**Recommendation:** Either drop Timer/Counter from S7AddressParser and S7Area
|
||
until they are wired through to S7.Net, or implement the Timer/Counter read path.
|
||
If kept, reject Timer/Counter tags at InitializeAsync with a clear "not yet
|
||
supported" error rather than letting them parse clean.
|
||
|
||
**Resolution:** Resolved 2026-05-22 — `InitializeAsync` now runs
|
||
`RejectUnsupportedTagAddresses`, which throws `NotSupportedException` with a
|
||
clear "not yet supported" message (echoing the tag name + address) for any tag
|
||
whose address parses as a Timer or Counter, so the bad config fails fast at init
|
||
rather than throwing a misleading type-mismatch on every read.
|
||
|
||
### Driver.S7-002
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Medium |
|
||
| Category | Correctness & logic bugs |
|
||
| Location | `S7Driver.cs:350` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** MapDataType collapses S7DataType.UInt32 to DriverDataType.Int32.
|
||
UInt32 values above int.MaxValue (2^31-1) wrap to negative when surfaced to the
|
||
OPC UA client, silently corrupting the value. The inline comment only flags
|
||
Int64/UInt64 as "widens; lossy" but UInt32 to Int32 is equally lossy and is not
|
||
called out.
|
||
|
||
**Recommendation:** Map UInt32/UInt16 to a DriverDataType wide enough to hold the
|
||
unsigned range, or add the missing unsigned DriverDataType members. At minimum
|
||
correct the comment so the lossiness of UInt32 is documented.
|
||
|
||
**Resolution:** Resolved 2026-05-22 — added an inline comment to the `MapDataType` switch explicitly documenting the UInt32→Int32 lossiness (same limitation as Int64/UInt64, tracked for a follow-up PR adding unsigned DriverDataType members); the code mapping is unchanged pending that follow-up.
|
||
|
||
### Driver.S7-003
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Low |
|
||
| Category | Correctness & logic bugs |
|
||
| Location | `S7Driver.cs:172`, `S7Driver.cs:255` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** ReadAsync and WriteAsync dereference fullReferences.Count /
|
||
writes.Count with no null guard. A null argument throws NullReferenceException
|
||
rather than ArgumentNullException, and the NRE escapes before the _gate is taken
|
||
so it is not wrapped in a per-item status. DiscoverAsync correctly uses
|
||
ArgumentNullException.ThrowIfNull(builder); the read/write entry points are
|
||
inconsistent with it.
|
||
|
||
**Recommendation:** Add ArgumentNullException.ThrowIfNull for the list parameters
|
||
at the top of ReadAsync and WriteAsync.
|
||
|
||
**Resolution:** Resolved 2026-05-23 — added `ArgumentNullException.ThrowIfNull`
|
||
at the top of both `ReadAsync` and `WriteAsync`, placed BEFORE `RequirePlc()` so
|
||
a null argument produces a typed `ArgumentNullException` (consistent with
|
||
`DiscoverAsync`) rather than either an NRE on `.Count` or the "not initialized"
|
||
`InvalidOperationException` from `RequirePlc`. Regression tests
|
||
`ReadAsync_with_null_fullReferences_throws_ArgumentNullException` and
|
||
`WriteAsync_with_null_writes_throws_ArgumentNullException`.
|
||
|
||
### Driver.S7-004
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Medium |
|
||
| Category | OtOpcUa conventions |
|
||
| Location | `S7Driver.cs` (whole file) |
|
||
| Status | Resolved |
|
||
|
||
**Description:** The driver performs no logging. CLAUDE.md Library Preferences
|
||
mandate Serilog with a rolling daily file sink. Every error path is an empty
|
||
catch block (Initialize cleanup line 130, ShutdownAsync lines 142/149/153,
|
||
ProbeLoop line 483, PollLoop lines 396/406, Dispose line 511). Connection faults,
|
||
probe transitions, PUT/GET-disabled config errors, and poll-loop exceptions are
|
||
all silently swallowed. An operator has only the DriverHealth.LastError string
|
||
and no event trail to diagnose an intermittent PLC.
|
||
|
||
**Recommendation:** Inject an ILogger/ILoggerFactory and log connect
|
||
success/failure, probe Running/Stopped transitions, PUT/GET-disabled detection,
|
||
and swallowed poll-loop / shutdown exceptions.
|
||
|
||
**Resolution:** Resolved 2026-05-22 — injected `ILogger<S7Driver>` (optional, defaults to `NullLogger`) into the primary constructor; added structured log calls for connect success/failure, probe Running/Stopped transitions, and swallowed poll-loop exceptions, giving operators an event trail via Serilog.
|
||
|
||
### Driver.S7-005
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Low |
|
||
| Category | OtOpcUa conventions |
|
||
| Location | `S7Driver.cs:33`, `S7Driver.cs:433` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** System.Collections.Concurrent.ConcurrentDictionary is written
|
||
out with a fully-qualified namespace at the field declarations instead of a
|
||
using System.Collections.Concurrent directive. ImplicitUsings is enabled and the
|
||
rest of the codebase relies on using directives; the inline FQN is inconsistent
|
||
with house style. Similar redundant global::S7.Net.* qualifiers appear throughout
|
||
S7Driver.cs despite the file-top using S7.Net.
|
||
|
||
**Recommendation:** Add using System.Collections.Concurrent and drop the
|
||
redundant global::S7.Net. qualifiers where using S7.Net already covers them.
|
||
|
||
**Resolution:** Resolved 2026-05-23 — `using System.Collections.Concurrent` was
|
||
already added by an earlier finding fix; this resolution removes the remaining
|
||
`global::S7.Net.Plc` qualifiers from the `ReadOneAsync` and `WriteOneAsync`
|
||
signatures, now using the unqualified `Plc` type (the file-top `using S7.Net`
|
||
already covers it). House style restored.
|
||
|
||
### Driver.S7-006
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | High |
|
||
| Category | Concurrency & thread safety |
|
||
| Location | `S7Driver.cs:140`, `S7Driver.cs:457`, `S7Driver.cs:506` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** Disposal races with the in-flight probe / poll tasks.
|
||
ShutdownAsync calls _probeCts.Cancel() and cancels each subscription CTS, but it
|
||
does not await the ProbeLoopAsync / PollLoopAsync tasks (they are fire-and-forget
|
||
Task.Run with the task handle discarded). DisposeAsync then calls ShutdownAsync
|
||
followed immediately by _gate.Dispose(). A probe or poll iteration that is
|
||
between _gate.WaitAsync and _gate.Release() when cancellation fires will call
|
||
Release() (line 479) or have WaitAsync observe a disposed semaphore -
|
||
ObjectDisposedException. The probe loop broad catch swallows it, but the
|
||
disposal-ordering bug is real: the semaphore can be disposed while a worker still
|
||
holds or is waiting on it. The same applies to _probeCts.Dispose() (line 143)
|
||
running while ProbeLoopAsync may still touch the linked token.
|
||
|
||
**Recommendation:** Track the probe and poll Task handles, and in ShutdownAsync
|
||
(or DisposeAsync) await Task.WhenAll(...) with a bounded timeout after cancelling,
|
||
before disposing _gate and the CTS objects.
|
||
|
||
**Resolution:** Resolved 2026-05-22 — the probe loop now stores its Task in
|
||
`_probeTask` and each subscription records its poll Task in `SubscriptionState.PollTask`.
|
||
`ShutdownAsync` cancels every CTS, awaits `Task.WhenAll` of those handles with a
|
||
bounded 5 s `DrainTimeout`, and only then disposes `_probeCts`, the subscription
|
||
CTSs, and (via `DisposeAsync`) `_gate` — so no loop can touch a disposed
|
||
semaphore. `Task.Run` is now passed `CancellationToken.None` so the handle is
|
||
always awaitable even if the token is already cancelled.
|
||
|
||
### Driver.S7-007
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | High |
|
||
| Category | Error handling & resilience |
|
||
| Location | `S7Driver.cs:200`, `S7DriverOptions.cs:13`, `docs/v2/driver-specs.md:434` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** PUT/GET-disabled handling contradicts the design and the
|
||
module own docstring. driver-specs.md section 5 (line 434) and the
|
||
S7DriverOptions class remark both state PUT/GET-disabled must be mapped to
|
||
BadNotSupported and surfaced as a configuration alert, not a transient fault,
|
||
because blind retry is wasted effort. The actual code (ReadAsync, lines 200-208)
|
||
catches every S7.Net.PlcException and maps it to StatusBadDeviceFailure, then
|
||
sets health to Degraded. Consequences: (1) a genuinely transient PlcException
|
||
(e.g. CPU briefly in STOP) is reported identically to a permanent PUT/GET
|
||
misconfiguration - the operator cannot tell a config problem from a transient
|
||
one, which is the exact distinction the spec demands; (2) the promised
|
||
BadNotSupported status code is never produced, so the S7DriverOptions docstring
|
||
is now false.
|
||
|
||
**Recommendation:** Inspect PlcException.ErrorCode and map the
|
||
PUT/GET-disabled / access-denied code to BadNotSupported with a distinct
|
||
config-alert health state; keep BadDeviceFailure/Degraded only for genuine
|
||
device-fault error codes.
|
||
|
||
**Resolution:** Resolved 2026-05-22 — `ReadAsync` / `WriteAsync` now split the
|
||
`PlcException` catch via an `IsAccessDenied` filter. S7.Net exposes no typed
|
||
error code for the S7 `AccessingObjectNotAllowed` status (its
|
||
`ValidateResponseCode` throws a plain `Exception` wrapped as the inner exception
|
||
of a `PlcException`), so `IsAccessDenied` walks the inner-exception chain for the
|
||
"not allowed" marker. A PUT/GET-disabled fault now maps to `BadNotSupported` and
|
||
sets health to `Faulted` with a config-alert message pointing operators at the
|
||
TIA Portal PUT/GET toggle; a genuine device fault still maps to
|
||
`BadDeviceFailure`/`Degraded`.
|
||
|
||
### Driver.S7-008
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Medium |
|
||
| Category | Error handling & resilience |
|
||
| Location | `S7Driver.cs:286` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** WriteAsync catch ladder is coarser than ReadAsync and loses
|
||
information. The generic catch (Exception) maps everything - socket errors,
|
||
timeouts, OverflowException from Convert.ToInt16 of an out-of-range value,
|
||
NullReferenceException from Convert.ToBoolean(null) - to StatusBadInternalError.
|
||
A genuine transport fault during a write is reported to the client as an internal
|
||
error rather than BadCommunicationError, and unlike ReadAsync the write path never
|
||
updates _health on failure, so a PLC that is down stays Healthy in the dashboard
|
||
as long as only writes are attempted. OperationCanceledException is also caught
|
||
and turned into a status code rather than propagating.
|
||
|
||
**Recommendation:** Mirror the ReadAsync catch structure: let
|
||
OperationCanceledException propagate, map socket/timeout faults to
|
||
BadCommunicationError, map value-conversion failures to a distinct out-of-range
|
||
status, and update _health to Degraded on transport failures.
|
||
|
||
**Resolution:** Resolved 2026-05-22 — restructured `WriteAsync` catch ladder: `OperationCanceledException` now re-throws, genuine `PlcException` transport faults map to `BadDeviceFailure`/`Degraded`, `NotSupportedException` maps to `BadNotSupported`, the `IsAccessDenied` PlcException path maps to `BadNotSupported`/`Faulted`, and the catch-all maps to `BadCommunicationError` with a health update — matching `ReadAsync`'s structure.
|
||
|
||
### Driver.S7-009
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Low |
|
||
| Category | Error handling & resilience |
|
||
| Location | `S7Driver.cs:392` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** The subscription poll loop never reflects sustained polling
|
||
failure anywhere an operator can see it. PollLoopAsync swallows every
|
||
non-cancellation exception with an empty catch and the comment claims "the health
|
||
surface reflects it" - but a poll failure routes through ReadAsync, which only
|
||
sets DriverState.Degraded when the per-tag read throws inside the gate;
|
||
exceptions thrown before that (e.g. RequirePlc() when Plc is null after a drop)
|
||
bypass the health update entirely. A subscription against an uninitialized or
|
||
dropped driver loops forever silently, with no backoff - re-polling every
|
||
Interval indefinitely on a hard failure.
|
||
|
||
**Recommendation:** Have the poll loop update _health on repeated failure and
|
||
apply a capped backoff after consecutive errors; at minimum log the swallowed
|
||
exception (see Driver.S7-004).
|
||
|
||
**Resolution:** Resolved 2026-05-23 — `PollLoopAsync` now tracks
|
||
`consecutiveFailures`, calls new `HandlePollFailure` which both logs (with the
|
||
failure count) AND degrades `_health` to `Degraded` once
|
||
`PollFailureHealthThreshold` (1) consecutive failures have accumulated, and
|
||
applies a capped exponential backoff via new `ComputeBackoffDelay` (doubles the
|
||
wait each consecutive failure up to a 30 s `PollBackoffCap`). A healthy tick
|
||
resets the counter so the cadence snaps back to the configured Interval.
|
||
`HandlePollFailure` refuses to downgrade a `Faulted` state (reserved for
|
||
permanent config faults like PUT/GET-denied). Regression test
|
||
`PollLoop_against_uninitialized_driver_degrades_health` proves the health
|
||
surface now reflects sustained failure; `PollLoop_applies_capped_backoff_after_consecutive_failures`
|
||
proves shutdown still completes inside the drain window even under a fault
|
||
storm.
|
||
|
||
### Driver.S7-010
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Low |
|
||
| Category | Performance & resource management |
|
||
| Location | `S7Driver.cs:504` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** Dispose() is implemented as
|
||
DisposeAsync().AsTask().GetAwaiter().GetResult() - sync-over-async. Inside the
|
||
generic host this is currently safe (no captured SynchronizationContext), but it
|
||
is a known deadlock pattern. The only async work behind DisposeAsync is
|
||
ShutdownAsync, which does nothing async (returns Task.CompletedTask). The
|
||
blocking wrap is unnecessary risk.
|
||
|
||
**Recommendation:** Since ShutdownAsync is effectively synchronous, have Dispose()
|
||
perform the teardown directly (cancel CTSs, close Plc, dispose _gate) without
|
||
round-tripping through the async path.
|
||
|
||
**Resolution:** Resolved 2026-05-23 — `Dispose()` now performs teardown
|
||
directly via a new private `SynchronousTeardown` method that mirrors
|
||
`ShutdownAsync` but uses `Task.WhenAll(...).Wait(DrainTimeout)` instead of
|
||
`await Task.WhenAll(...).WaitAsync(...)`. Probe + poll Tasks are still drained
|
||
with the bounded 5 s timeout (so a wedged loop cannot hang `Dispose` indefinitely),
|
||
but the sync path no longer round-trips through `DisposeAsync().AsTask().GetAwaiter().GetResult()`.
|
||
`DisposeAsync` keeps its existing implementation for callers that opt into the
|
||
async dispose pattern. Regression tests
|
||
`Dispose_completes_synchronously_without_sync_over_async_round_trip` and
|
||
`Dispose_is_idempotent`.
|
||
|
||
### Driver.S7-011
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | High |
|
||
| Category | Design-document adherence |
|
||
| Location | `S7Driver.cs:82`, `S7Driver.cs:134`, `IDriver.cs:24` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** S7Driver ignores the driverConfigJson parameter on both
|
||
InitializeAsync and ReinitializeAsync. The IDriver contract states InitializeAsync
|
||
initializes the driver "from its DriverConfig JSON" and ReinitializeAsync "applies
|
||
a config change in place". All configuration is instead captured in the
|
||
constructor (S7DriverOptions options), and ReinitializeAsync simply calls
|
||
ShutdownAsync then InitializeAsync with the same options object. Consequently a
|
||
config change delivered to ReinitializeAsync (the documented IGenerationApplier
|
||
recovery path per driver-stability.md) is silently discarded - the driver
|
||
re-opens with the old config. This breaks the only Core-initiated in-process
|
||
recovery path.
|
||
|
||
**Recommendation:** Either re-parse driverConfigJson inside
|
||
InitializeAsync/ReinitializeAsync and rebuild _options from it, or document
|
||
explicitly that S7 reconfiguration requires instance recreation and have
|
||
ReinitializeAsync signal that the passed JSON is unused so the contract mismatch
|
||
is visible.
|
||
|
||
**Resolution:** Resolved 2026-05-22 — config parsing was factored out of the
|
||
factory into `S7DriverFactoryExtensions.ParseOptions`. `InitializeAsync` (and
|
||
therefore `ReinitializeAsync`, which delegates to it) now re-parses
|
||
`driverConfigJson` and rebuilds `_options` from it whenever the document carries
|
||
a real body, so a config change delivered through `ReinitializeAsync` — the only
|
||
Core-initiated in-process recovery path — is honoured. An empty / placeholder
|
||
document (`""`, `{}`, `[]`) keeps the constructor-supplied options so existing
|
||
lifecycle unit tests that pass `"{}"` are unaffected.
|
||
|
||
### Driver.S7-012
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Medium |
|
||
| Category | Design-document adherence |
|
||
| Location | `S7DriverOptions.cs:59`, `S7Driver.cs:457` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** S7ProbeOptions.ProbeAddress is configured (default "MW0"),
|
||
documented at length ("the driver runs a tick loop that issues a cheap read
|
||
against S7ProbeOptions.ProbeAddress"), surfaced in the factory DTO
|
||
(S7ProbeDto.ProbeAddress), and parsed from JSON - but it is never read by any
|
||
code. ProbeLoopAsync probes liveness via plc.ReadStatusAsync (CPU status), not via
|
||
a read of ProbeAddress. The XML doc on the S7DriverOptions.Probe property and on
|
||
ProbeAddress describes behaviour the driver does not implement. An operator who
|
||
sets ProbeAddress to a known-good DB word expecting the probe to exercise it will
|
||
see no effect.
|
||
|
||
**Recommendation:** Either make ProbeLoopAsync actually read ProbeAddress
|
||
(parsing it once at init and rejecting a bad value early), or delete ProbeAddress
|
||
from S7ProbeOptions/S7ProbeDto and correct the XML docs to describe the
|
||
ReadStatusAsync-based probe.
|
||
|
||
**Resolution:** Resolved 2026-05-22 — removed `ProbeAddress` from `S7ProbeOptions` and `S7ProbeDto`; updated the `S7DriverOptions.Probe` XML doc to describe the `ReadStatusAsync`-based probe accurately. Existing configs that set `probeAddress` are silently ignored (unknown JSON fields are tolerated by the deserializer).
|
||
|
||
### Driver.S7-013
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Low |
|
||
| Category | Code organization & conventions |
|
||
| Location | `S7DriverOptions.cs:90`, `S7Driver.cs:300` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** S7TagDefinition.StringLength is a public configured/JSON-bound
|
||
parameter (default 254) but is dead: S7DataType.String reads and writes both
|
||
throw NotSupportedException ("...land in a follow-up PR"), so StringLength is
|
||
never consumed. Likewise S7DataType.Int64, UInt64, Float64, String, and DateTime
|
||
are exposed as configurable, browse through MapDataType into real DriverDataType
|
||
values, and pass DiscoverAsync - creating address-space nodes - yet every
|
||
read/write of them throws NotSupportedException, becoming BadNotSupported. A site
|
||
can configure a Float64 tag, see the node appear, and get BadNotSupported on
|
||
every access. The scaffold/follow-up-PR split leaks half-implemented types into
|
||
the configurable surface.
|
||
|
||
**Recommendation:** Reject the not-yet-implemented S7DataType values (and
|
||
StringLength) at InitializeAsync / factory validation with a clear "not yet
|
||
supported" error, so a partially-implemented type cannot be configured into a
|
||
live address space.
|
||
|
||
**Resolution:** Resolved 2026-05-23 — `InitializeAsync` now runs new
|
||
`RejectUnsupportedTagDataTypes`, which throws `NotSupportedException` for any
|
||
tag whose `DataType` is in the `UnimplementedDataTypes` set (`Int64`, `UInt64`,
|
||
`Float64`, `String`, `DateTime`). The half-implemented types can no longer leak
|
||
into the live address space — a site that configures one fails fast at init
|
||
rather than seeing a node that returns `BadNotSupported` on every access.
|
||
Entries should be removed from `UnimplementedDataTypes` as each type is wired
|
||
through; the comment on `RejectUnsupportedTagDataTypes` makes it a single grep
|
||
target for that follow-up. `StringLength` remains in `S7TagDefinition` because
|
||
removing it would be a breaking change to existing config JSON; once `String`
|
||
is implemented it will be consumed without further config changes. Regression
|
||
tests `Initialize_rejects_not_yet_implemented_data_type_with_NotSupportedException`
|
||
(Theory, 5 types) and `Initialize_accepts_implemented_data_types` (Theory, 7
|
||
types) prove the guard is targeted.
|
||
|
||
### Driver.S7-014
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Medium |
|
||
| Category | Testing coverage |
|
||
| Location | `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** Test coverage has notable gaps for the driver behavioural
|
||
core: (1) no test exercises the ReadOneAsync type-reinterpret switch (Int16 from
|
||
ushort, Int32 from uint, Float32 from UInt32 bits) - the most logic-heavy method
|
||
in the driver is untested, and the unsigned/signed unchecked casts are
|
||
unverified; (2) no test covers a Timer/Counter tag end-to-end, which would have
|
||
caught Driver.S7-001; (3) no test covers WriteOneAsync boxing conversions or
|
||
the out-of-range Convert failure paths; (4) the read-write tests only cover error
|
||
paths (uninitialized, bad address) - the happy path is explicitly deferred to "a
|
||
follow-up PR" with no mock S7 server, leaving the entire successful read, write,
|
||
poll, and probe-transition surface untested; (5) ReinitializeAsync and the
|
||
driverConfigJson-ignored behaviour (Driver.S7-011) has no test.
|
||
|
||
**Recommendation:** Add unit tests for ReadOneAsync/WriteOneAsync type mapping by
|
||
factoring the pure reinterpret/boxing logic out of the PLC round-trip so it is
|
||
testable without a live PLC, and add a Timer/Counter rejection test. Track the
|
||
live/mock-server happy-path coverage as an explicit follow-up rather than an
|
||
open-ended deferral.
|
||
|
||
**Resolution:** Resolved 2026-05-22 — factored `ReadOneAsync` type-reinterpret into `internal static ReinterpretRawValue` and `WriteOneAsync` boxing into `internal static BoxValueForWrite`; added `S7TypeMappingTests.cs` (26 tests) covering every implemented type round-trip (Bool/Byte/UInt16/Int16/UInt32/Int32/Float32), unsupported-type `NotSupportedException` assertions, and write overflow paths.
|
||
|
||
### Driver.S7-015
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Medium |
|
||
| Category | Correctness & logic bugs |
|
||
| Location | `S7Driver.cs` — `RejectUnsupportedTagConfigs`, `WriteOneAsync` |
|
||
| Status | Resolved |
|
||
|
||
**Description:** `WriteOneAsync` has no array write path. Array reads are fully implemented (`ReadArrayAsync` / `DecodeArrayBlock`), but `WriteOneAsync` has no symmetric `WriteArrayAsync` branch. When a writable array tag (e.g., `Int16[4]`) receives a write, `WriteOneAsync` falls through to `BoxValueForWrite(tag.DataType, value)` with the whole typed array as the value argument. `Convert.ToInt16(short[])` throws `InvalidCastException`, which the outer catch maps to `BadCommunicationError` — misleading to an operator who expects `BadNotSupported`. An init-time guard that rejects writable array tags existed only for wide-type arrays (guard-a in `RejectUnsupportedTagConfigs`); non-wide arrays (Int16[], UInt16[], Float32[], etc.) were accepted at init, created writable OPC UA nodes, and failed on every write with an uninformative status code.
|
||
|
||
**Recommendation:** Add init-time guard-(e) in `RejectUnsupportedTagConfigs` rejecting any `Writable=true` array tag (non-wide types). Also add a defensive `NotSupportedException` at the top of `WriteOneAsync` for transient equipment-tag refs that bypass init validation. Both paths correctly map to `BadNotSupported` via the existing catch ladder.
|
||
|
||
**Resolution:** Resolved 2026-06-19 (commit SHA blank) — added guard-(e) to `RejectUnsupportedTagConfigs` that throws `NotSupportedException` for any non-wide writable array tag; added a defensive `NotSupportedException` at the top of `WriteOneAsync` for transient equipment-tag refs. Regression tests: `Initialize_rejects_writable_array_tag_with_NotSupportedException` (Theory, 7 element types × non-wide path) and `Initialize_accepts_readonly_array_tag` (verifies read-only arrays still pass).
|
||
|
||
### Driver.S7-016
|
||
|
||
| Field | Value |
|
||
|---|---|
|
||
| Severity | Low |
|
||
| Category | Design-document adherence |
|
||
| Location | `S7DriverFactoryExtensions.cs` — `S7TagDto`, `BuildTag` |
|
||
| Status | Deferred |
|
||
|
||
**Description:** `S7TagDto` lacks `ArrayCount`/`IsArray` fields and `BuildTag` never passes `ArrayCount` to `S7TagDefinition`. As a result, tags authored via the standard driver JSON config (the factory path) can never be configured as arrays — `ArrayCount` is always null. Only equipment-tag refs resolved transiently by `S7EquipmentTagParser` can carry `ArrayCount`. The array infrastructure (read + init guards) is in place; the factory DTO simply doesn't surface the knob. A site that wants to configure a multi-element tag via the standard tag table has no way to do so.
|
||
|
||
**Recommendation:** Add `int? ArrayCount` and `bool? IsArray` to `S7TagDto` and propagate them through `BuildTag`. Mirror the `S7EquipmentTagParser` semantics (honour `arrayLength` only when `isArray` is true and the value is positive).
|
||
|
||
**Resolution:** Deferred — requires an AdminUI page/DTO change and a corresponding config-form field addition. Tracked as a follow-up to the array-read Phase 4d work. No code change in this review; the existing init guard-(e) correctly rejects any programmatically-constructed writable array reaching the driver until the DTO is wired.
|