Renames all 11 projects (5 src + 6 tests), the .slnx solution file, all source-file namespaces, all axaml namespace references, and all v1 documentation references in CLAUDE.md and docs/*.md (excluding docs/v2/ which is already in OtOpcUa form). Also updates the TopShelf service registration name from "LmxOpcUa" to "OtOpcUa" per Phase 0 Task 0.6.
Preserves runtime identifiers per Phase 0 Out-of-Scope rules to avoid breaking v1/v2 client trust during coexistence: OPC UA `ApplicationUri` defaults (`urn:{GalaxyName}:LmxOpcUa`), server `EndpointPath` (`/LmxOpcUa`), `ServerName` default (feeds cert subject CN), `MxAccessConfiguration.ClientName` default (defensive — stays "LmxOpcUa" for MxAccess audit-trail consistency), client OPC UA identifiers (`ApplicationName = "LmxOpcUaClient"`, `ApplicationUri = "urn:localhost:LmxOpcUaClient"`, cert directory `%LocalAppData%\LmxOpcUaClient\pki\`), and the `LmxOpcUaServer` class name (class rename out of Phase 0 scope per Task 0.5 sed pattern; happens in Phase 1 alongside `LmxNodeManager → GenericDriverNodeManager` Core extraction). 23 LmxOpcUa references retained, all enumerated and justified in `docs/v2/implementation/exit-gate-phase-0.md`.
Build clean: 0 errors, 30 warnings (lower than baseline 167). Tests at strict improvement over baseline: 821 passing / 1 failing vs baseline 820 / 2 (one flaky pre-existing failure passed this run; the other still fails — both pre-existing and unrelated to the rename). `Client.UI.Tests`, `Historian.Aveva.Tests`, `Client.Shared.Tests`, `IntegrationTests` all match baseline exactly. Exit gate compliance results recorded in `docs/v2/implementation/exit-gate-phase-0.md` with all 7 checks PASS or DEFERRED-to-PR-review (#7 service install verification needs Windows service permissions on the reviewer's box).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
41 lines
1.2 KiB
C#
41 lines
1.2 KiB
C#
using System.Diagnostics;
|
|
using Shouldly;
|
|
using Xunit;
|
|
using ZB.MOM.WW.OtOpcUa.Host;
|
|
using ZB.MOM.WW.OtOpcUa.Host.Configuration;
|
|
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Tests.Wiring
|
|
{
|
|
/// <summary>
|
|
/// Verifies: Start then Stop completes within 30 seconds. (SVC-004)
|
|
/// </summary>
|
|
public class ShutdownCompletesTest
|
|
{
|
|
/// <summary>
|
|
/// Confirms that a started service can shut down within the required time budget.
|
|
/// </summary>
|
|
[Fact]
|
|
public void Shutdown_CompletesWithin30Seconds()
|
|
{
|
|
var config = new AppConfiguration
|
|
{
|
|
OpcUa = new OpcUaConfiguration { Port = 14841, GalaxyName = "TestGalaxy" },
|
|
MxAccess = new MxAccessConfiguration { ClientName = "Test" },
|
|
Dashboard = new DashboardConfiguration { Enabled = false }
|
|
};
|
|
|
|
var proxy = new FakeMxProxy();
|
|
var repo = new FakeGalaxyRepository();
|
|
var service = new OpcUaService(config, proxy, repo);
|
|
|
|
service.Start();
|
|
|
|
var sw = Stopwatch.StartNew();
|
|
service.Stop();
|
|
sw.Stop();
|
|
|
|
sw.Elapsed.TotalSeconds.ShouldBeLessThan(30);
|
|
}
|
|
}
|
|
} |