Makes the /raw device tree addressable by an ACL rule, and builds the
scope-path producer PermissionTrieBuilder has accepted since it was written
but which had no caller anywhere.
The plan for this stage said "add NodeHierarchyKind.Raw, whose path is the
RawPath segments Folder/Driver/Device/TagGroup/Tag". That shape is wrong.
RawFolder.ParentRawFolderId and TagGroup.ParentTagGroupId are both
self-referencing, so folders and tag groups each nest without bound and a real
RawPath is folder…/Driver/Device/group…/Tag. NodeScope was fixed-arity and
PermissionTrie.CollectMatches was five hardcoded steps, so the scope model
could not address a real raw tree at all. NodeScope is now {ClusterId, Kind,
Segments} and the walk is a segment loop. The trie STRUCTURE was already
variable-depth (NodeAclPath.Segments is a list, Children is a recursive
dictionary), so only the walker and the scope record had to change.
Four decisions worth keeping:
- The namespace level became the realm. Level 1 gated on NodeScope.NamespaceId,
but v3 has no Namespace entity — the snapshot was retired when the address
space went dual-namespace, and the identifier appears nowhere in production
outside NodeScope. So the level could only ever fail to match, which silently
made every sub-cluster grant unreachable while cluster grants kept working.
It is now a realm token derived from the scope's Kind, not carried on it, so
the walk and the producer cannot disagree about its spelling.
- Provenance comes from the granting row's own ScopeKind, recorded on TrieGrant
at build time. Depth-derived provenance could not name a raw level at all,
since the depth of "Device" varies with folder nesting.
- The trie comparer moved from OrdinalIgnoreCase to Ordinal. Raw sibling-name
uniqueness is ordinal, so Speed and speed can both exist under one device and
a grant on either would have matched both.
- The null-scopePaths "deterministic test mode" is deleted. It planted
unresolvable rows at a direct child of the trie root, a position the walker
cannot reach, so the grant looked placed and could never match — and every
test using that mode proved nothing about production placement. scopePaths is
now required, and a row that does not resolve is dropped with a diagnostic.
A scope resolves to a LIST of paths: a raw tag projected into N equipments is
reachable at N+1 NodeIds and a write through any of them lands on the same
driver reference, so a Tag-scoped grant covering only the raw node would be
bypassable through a UNS one. The lookup is keyed on (ScopeKind, ScopeId), not
ScopeId alone — ScopeId has no FK and no type discriminator, so an id collision
across entity types would hand a grant the wrong node's paths.
Also closed here, all found by review rather than asked for:
- NodeAcl rows had no deploy-time validation of any kind and were not reachable
from DraftValidator at all (DraftSnapshot carried no NodeAcls). They are now
gated for dangling ids, cross-cluster scopes, blank/contradictory ScopeId, the
retired FolderSegment kind, and undefined ordinals.
- ConfigDbApiKeyStore conferred roles from Cluster-scoped grants authored in ANY
cluster, because it filtered on scope kind with no ClusterId predicate while
ArtifactApiKeyStore read an already-cluster-filtered snapshot. On a fused
admin+driver node that was a cross-cluster over-grant. Its doc comment claimed
the two stores matched.
- The two AdminUI ACL banners still said enforcement was LDAP-group -> role
mapping, which stages 1/2 made false in both directions.
- The /apikeys page was never classified in PageAuthorizationGuardTests, so that
test has been red since the key-minting commit merged — I did not run
AdminUI.Tests before merging stage 4.
Falsified rather than assumed: 8 mutations against the trie tests, 5 against the
deploy gate (including one proving a cross-cluster row is not silently
mis-diagnosed as unresolved), a staged red->green for the over-grant regression,
and the realm gate, the comparer and the malformed-path guard each broken
individually to confirm only their own tests go red.
Node ACLs are still not ENFORCED — nothing constructs a NodeScope or calls the
evaluator yet. That is stages 5 and 6; this stage makes the model able to
express what those will enforce.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
OtOpcUa
OPC UA server (.NET 10 AnyCPU) that exposes a fleet of industrial drivers as a single OPC UA address space. Drivers ship in-process for AVEVA System Platform Galaxy (via the sibling mxaccessgw repo), Modbus TCP, Siemens S7, Allen-Bradley CIP (ControlLogix / CompactLogix), Allen-Bradley Legacy (SLC 500 / MicroLogix), Beckhoff TwinCAT (ADS), FANUC FOCAS, OPC UA Client (gateway), and MQTT (broker subscribe; Sparkplug B in progress).
A cross-platform client stack (.NET 10) — shared library, CLI, and Avalonia desktop app — connects to any OPC UA server.
Architecture
OPC UA Clients (CLI, Desktop UI, 3rd-party)
|
v
+-------------------------------------+
| OtOpcUa.Server (.NET 10 AnyCPU) |
| address space + capability fan-out|
+-------------------------------------+
| | | | | | | |
Galaxy Modbus S7 AbCip AbLeg TwinCAT FOCAS OpcUaClient MQTT
|
v
mxaccessgw (sibling repo, gRPC)
|
v
MXAccess COM (x86 worker, on AVEVA box)
Galaxy is the only driver with an external runtime: it speaks gRPC to a separately installed mxaccessgw server (sibling repo at c:\Users\dohertj2\Desktop\mxaccessgw\) which owns the MXAccess COM apartment and the x86/STA bitness constraint server-side. Everything in this repo is platform-agnostic .NET 10.
Prerequisites
- .NET 10 SDK (server, drivers, clients all target .NET 10)
- SQL Server reachable for the central config DB
- For Galaxy specifically: a running
mxaccessgwdeployment — see docs/v2/Galaxy.ParityRig.md - For historian read-back / alarm history / continuous historization: a running
ZB.MOM.WW.HistorianGatewaydeployment (the sole historian backend; consumed as theZB.MOM.WW.HistorianGateway.ClientgRPC package). It must runRuntimeDb:Enabled=true+RuntimeDb:EventReadsEnabled=true, and the API key must carryhistorian:read+historian:write+historian:tags:writescopes.
Quick Start
dotnet restore ZB.MOM.WW.OtOpcUa.slnx
dotnet build ZB.MOM.WW.OtOpcUa.slnx
dotnet test ZB.MOM.WW.OtOpcUa.slnx
# Run the server in dev (foreground)
dotnet run --project src/Server/ZB.MOM.WW.OtOpcUa.Host
The server starts on opc.tcp://localhost:4840 with the None security profile. Configure Security.Profiles in src/Server/ZB.MOM.WW.OtOpcUa.Host/appsettings.json to enable Basic256Sha256-Sign or Basic256Sha256-SignAndEncrypt. See docs/security.md.
Install as Windows Services
Production deployment is driven by scripts/install/Install-Services.ps1, which registers the OtOpcUa server service under a chosen service account. Historian support requires a separately deployed ZB.MOM.WW.HistorianGateway and Galaxy support a separately installed mxaccessgw — neither this repo nor the install script provisions them.
.\scripts\install\Install-Services.ps1 `
-InstallRoot 'C:\Program Files\OtOpcUa' `
-ServiceAccount 'DOMAIN\svc-otopcua'
The historian backend is the external ZB.MOM.WW.HistorianGateway (not installed by this script). See the script header and docs/ServiceHosting.md for full options.
Client CLI
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- connect -u opc.tcp://localhost:4840
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- browse -u opc.tcp://localhost:4840 -r -d 3
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- read -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode"
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- write -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -v 42
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- subscribe -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -i 500
See docs/Client.CLI.md and docs/Client.UI.md.
Documentation
Architecture deep-dives
| Topic | Doc |
|---|---|
| OPC UA server composition, namespace fan-out, Polly invoker | docs/OpcUaServer.md |
| Address space layout | docs/AddressSpace.md |
| Read / Write dispatch (driver vs virtual vs scripted-alarm) | docs/ReadWriteOperations.md |
| Incremental sync (driver-backend rediscovery + config publishes) | docs/IncrementalSync.md |
| Service hosting (Server + Admin; external HistorianGateway backend) | docs/ServiceHosting.md |
| Security (transport, LDAP, certificates) | docs/security.md |
| Redundancy | docs/Redundancy.md |
| Status dashboard | docs/StatusDashboard.md |
Drivers
| Topic | Doc |
|---|---|
| Driver specs (per-driver capability surface, config, addressing) | docs/v2/driver-specs.md |
| Galaxy driver | docs/drivers/Galaxy.md |
| Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient / MQTT | docs/drivers/ |
| Galaxy parity rig (mxaccessgw setup) | docs/v2/Galaxy.ParityRig.md |
| Galaxy performance + tracing | docs/v2/Galaxy.Performance.md |
Clients
| Topic | Doc |
|---|---|
| Client CLI | docs/Client.CLI.md |
| Client UI (Avalonia desktop) | docs/Client.UI.md |
v1 archive
The original v1 in-process MXAccess docs (Galaxy.Host topology, Configuration env vars, AlarmTracking, DataTypeMapping, HistoricalDataAccess, Subscriptions, etc.) are preserved under docs/v1/ — historical reference only. PR 7.2 retired the v1 architecture on 2026-04-30; current state is documented in the sections above.
License