Renames all 11 projects (5 src + 6 tests), the .slnx solution file, all source-file namespaces, all axaml namespace references, and all v1 documentation references in CLAUDE.md and docs/*.md (excluding docs/v2/ which is already in OtOpcUa form). Also updates the TopShelf service registration name from "LmxOpcUa" to "OtOpcUa" per Phase 0 Task 0.6.
Preserves runtime identifiers per Phase 0 Out-of-Scope rules to avoid breaking v1/v2 client trust during coexistence: OPC UA `ApplicationUri` defaults (`urn:{GalaxyName}:LmxOpcUa`), server `EndpointPath` (`/LmxOpcUa`), `ServerName` default (feeds cert subject CN), `MxAccessConfiguration.ClientName` default (defensive — stays "LmxOpcUa" for MxAccess audit-trail consistency), client OPC UA identifiers (`ApplicationName = "LmxOpcUaClient"`, `ApplicationUri = "urn:localhost:LmxOpcUaClient"`, cert directory `%LocalAppData%\LmxOpcUaClient\pki\`), and the `LmxOpcUaServer` class name (class rename out of Phase 0 scope per Task 0.5 sed pattern; happens in Phase 1 alongside `LmxNodeManager → GenericDriverNodeManager` Core extraction). 23 LmxOpcUa references retained, all enumerated and justified in `docs/v2/implementation/exit-gate-phase-0.md`.
Build clean: 0 errors, 30 warnings (lower than baseline 167). Tests at strict improvement over baseline: 821 passing / 1 failing vs baseline 820 / 2 (one flaky pre-existing failure passed this run; the other still fails — both pre-existing and unrelated to the rename). `Client.UI.Tests`, `Historian.Aveva.Tests`, `Client.Shared.Tests`, `IntegrationTests` all match baseline exactly. Exit gate compliance results recorded in `docs/v2/implementation/exit-gate-phase-0.md` with all 7 checks PASS or DEFERRED-to-PR-review (#7 service install verification needs Windows service permissions on the reviewer's box).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
101 lines
3.8 KiB
C#
101 lines
3.8 KiB
C#
using System.Collections.Generic;
|
|
using System.Threading.Tasks;
|
|
using Opc.Ua;
|
|
using Shouldly;
|
|
using Xunit;
|
|
using ZB.MOM.WW.OtOpcUa.Host.Domain;
|
|
using ZB.MOM.WW.OtOpcUa.Tests.Helpers;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Tests.Integration
|
|
{
|
|
public class HistorizingFlagTests
|
|
{
|
|
private static FakeGalaxyRepository CreateRepo()
|
|
{
|
|
return new FakeGalaxyRepository
|
|
{
|
|
Hierarchy = new List<GalaxyObjectInfo>
|
|
{
|
|
new()
|
|
{
|
|
GobjectId = 1, TagName = "TestObj", BrowseName = "TestObj", ParentGobjectId = 0, IsArea = false
|
|
}
|
|
},
|
|
Attributes = new List<GalaxyAttributeInfo>
|
|
{
|
|
new()
|
|
{
|
|
GobjectId = 1, TagName = "TestObj", AttributeName = "HistorizedAttr",
|
|
FullTagReference = "TestObj.HistorizedAttr", MxDataType = 2, IsHistorized = true
|
|
},
|
|
new()
|
|
{
|
|
GobjectId = 1, TagName = "TestObj", AttributeName = "NormalAttr",
|
|
FullTagReference = "TestObj.NormalAttr", MxDataType = 5, IsHistorized = false
|
|
},
|
|
new()
|
|
{
|
|
GobjectId = 1, TagName = "TestObj", AttributeName = "AlarmAttr",
|
|
FullTagReference = "TestObj.AlarmAttr", MxDataType = 1, IsAlarm = true
|
|
}
|
|
}
|
|
};
|
|
}
|
|
|
|
/// <summary>
|
|
/// Verifies that historized Galaxy attributes advertise OPC UA historizing support and history-read access.
|
|
/// </summary>
|
|
[Fact]
|
|
public async Task HistorizedAttribute_HasHistorizingTrue_AndHistoryReadAccess()
|
|
{
|
|
var fixture = OpcUaServerFixture.WithFakeMxAccessClient(repo: CreateRepo());
|
|
await fixture.InitializeAsync();
|
|
try
|
|
{
|
|
using var client = new OpcUaTestClient();
|
|
await client.ConnectAsync(fixture.EndpointUrl);
|
|
|
|
var nodeId = client.MakeNodeId("TestObj.HistorizedAttr");
|
|
var historizing = client.ReadAttribute(nodeId, Attributes.Historizing);
|
|
((bool)historizing.Value).ShouldBeTrue();
|
|
|
|
var accessLevel = client.ReadAttribute(nodeId, Attributes.AccessLevel);
|
|
var level = (byte)accessLevel.Value;
|
|
(level & AccessLevels.HistoryRead).ShouldBe(AccessLevels.HistoryRead,
|
|
"HistoryRead bit should be set");
|
|
}
|
|
finally
|
|
{
|
|
await fixture.DisposeAsync();
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// Verifies that non-historized Galaxy attributes do not claim OPC UA history support.
|
|
/// </summary>
|
|
[Fact]
|
|
public async Task NormalAttribute_HasHistorizingFalse_AndNoHistoryReadAccess()
|
|
{
|
|
var fixture = OpcUaServerFixture.WithFakeMxAccessClient(repo: CreateRepo());
|
|
await fixture.InitializeAsync();
|
|
try
|
|
{
|
|
using var client = new OpcUaTestClient();
|
|
await client.ConnectAsync(fixture.EndpointUrl);
|
|
|
|
var nodeId = client.MakeNodeId("TestObj.NormalAttr");
|
|
var historizing = client.ReadAttribute(nodeId, Attributes.Historizing);
|
|
((bool)historizing.Value).ShouldBeFalse();
|
|
|
|
var accessLevel = client.ReadAttribute(nodeId, Attributes.AccessLevel);
|
|
var level = (byte)accessLevel.Value;
|
|
(level & AccessLevels.HistoryRead).ShouldBe(0,
|
|
"HistoryRead bit should not be set");
|
|
}
|
|
finally
|
|
{
|
|
await fixture.DisposeAsync();
|
|
}
|
|
}
|
|
}
|
|
} |