aba3aa7a8d
OtOpcUaNodeManager.MapSeverity re-bucketed every projected severity onto the SDK's five EventSeverity values (<800 -> 700, else 900), defeating #626's exact OpcUaSeverity: an MTConnect Fault (800) read and evented as 900; a scripted alarm graded 1000 published 900 while /alerts said 1000; a native Low (200) published 300. EventSeverity merely names points on the 1..1000 scale, so the node now carries the value clamped to 1..1000 (ToPart9Severity), at materialise, projection and in the delta gate. MTConnect wire test now asserts Fault ActiveState=true/Severity=800 and the Normal clear ActiveState=false/Retain=false/Severity=800. Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe