Joseph Doherty
a6be2f77b5
FOCAS version-matrix stabilization (PR 1 of
#220
split) — ship the cheap half of the hardware-free stability gap ahead of the Tier-C out-of-process split. Without any CNC or simulator on the bench, the highest-leverage move is to catch operator config errors at init time instead of at steady-state per-read. Adds FocasCncSeries enum (Unknown/16i/0i-D/0i-F family/30i family/PowerMotion-i) + FocasCapabilityMatrix static class that encodes the per-series documented ranges for macro variables (cnc_rdmacro/wrmacro), parameters (cnc_rdparam/wrparam), and PMC letters + byte ceilings (pmc_rdpmcrng/wrpmcrng) straight from the Fanuc FOCAS Developer Kit. FocasDeviceOptions gains a Series knob (defaults Unknown = permissive so pre-matrix configs don't break on upgrade). FocasDriver.InitializeAsync now calls FocasAddress.TryParse on every tag + runs FocasCapabilityMatrix.Validate against the owning device's declared series, throwing InvalidOperationException with a reason string that names both the series and the documented limit ("Parameter
#30000
is outside the documented range [0, 29999] for Thirty_i") so an operator can tell whether the mismatch is in the config or in their declared CNC model. Unknown series skips validation entirely. Ships 46 new theory cases in FocasCapabilityMatrixTests.cs — covering every boundary in the matrix (widen 16i->0i-F: macro ceiling 999->9999, param 9999->14999; widen 0i-F->30i: PMC letters +K+T; PMC-number 16i=999/0i-D=1999/0i-F=9999/30i=59999), permissive Unknown-series behavior, rejection-message content, and case-insensitive PMC-letter matching. Widening a range without updating docs/v2/focas-version-matrix.md fails a test because every InlineData cites the row it reflects. Full FOCAS test suite stays at 165/165 passing (119 existing + 46 new). Also authors docs/v2/focas-version-matrix.md as the authoritative range reference with per-function citations, CNC-series era context, error-surface shape, and the link back to the matrix code; docs/v2/implementation/focas-isolation-plan.md as the multi-PR plan for
#220
Tier-C isolation (Shared contracts -> Host skeleton -> move Fwlib32 calls -> Supervisor+respawn -> MMF+ops glue, 2200-3200 LOC across 5 PRs mirroring the Galaxy Tier-C topology); and promotes docs/drivers/FOCAS-Test-Fixture.md from "version-matrix coverage = no" to explicit coverage via the new test file + cross-links to the matrix and isolation-plan docs. Leaves task
#220
open since isolation itself (the expensive half) is still ahead.
...
Co-Authored-By: Claude Opus 4.7 (1M context) <