Files
lmxopcua/docs/plans/2026-11-11-warm-redundancy-717-design.md
T
Joseph Doherty 2238da6504
v2-ci / unit-tests (push) Has been cancelled
docs(717): T0 SDK 2.0.1 re-proof — metadata and read projection pass; provenance and first-delivery choice fail as designed
The throwaway loopback spike (11/11 over the wire) shows SDK 2.0.1 clones the cached NotificationMessage on every
Publish, queued send and Republish, and pools notification payloads, so design §4.6's object-keyed provenance and
first-delivery ledger never match a delivered object (0 hits; Good leaks after demotion). A ledger keyed by
(SubscriptionId, SequenceNumber) plus a provenance token on the clone-copied MonitoredItemNotification.Message helper
passed the same matrix. Per the plan's T0 exit rule this re-opens D4's mechanism; T1+ wait for the owner's go/no-go.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 02:56:54 -05:00

332 lines
27 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Warm non-transparent redundancy with a degraded standby (Gitea #717): design spec
Status: **APPROVED by the owner 2026-11-13** (#717), together with the companion plan
(`2026-11-11-warm-redundancy-717-plan.md`). The §9 questions are answered; the answers are recorded in §9 and
applied throughout. Parent gate: #615 (G8 CTT, G9 production-client cutover). These stay open and separate from
everything here.
## 1. Owner decisions this spec builds on (not re-opened)
| # | Decision | Source |
|---|---|---|
| D1 | Advertise **Warm** for a 2-node pair, with an explicit degraded-standby contract; **None** for standalone. | #717 c7796 |
| D2 | Standby ServiceLevel in the **degraded band 2–199**; ordinary tag Reads/subscriptions on the standby **degrade**, while internal acquisition continues. Today's Secondary serves live Good data at 240, so it cannot just be relabelled. | #717 c7796, c7801, c9329 |
| D3 | Event subscriptions stay established on the standby; **new** alarm events are suppressed there; current retained conditions are refreshed on promotion. | #717 c7804 |
| D4 | **Strict first delivery.** After demotion, any Publish response delivered for the first time must not contain Good ordinary-tag values. That includes samples queued before demotion and batches built before it. Republish history and responses already in flight are preserved. | #717 c7849 |
| D5 | A client-initiated ConditionRefresh on the Warm standby **returns its current retained conditions**. Only new alarm events are suppressed. | #717 c11362 (2026-11-11) |
| D6 | The queue-only spike gate must not be adopted unchanged, because of late-overflow and filtered-retain effects. Product alarm suppression happens **before** SDK event-field projection. Per-tag read projection is the recommended data seam. Every ACL, direct-item and Server-object refresh path needs coverage. Role snapshots need an ordered revision. | #717 c7812, c7853, issue body |
| D7 | Existing mutation and election policies are preserved: the write/native-ack/HistoryUpdate Primary gates, the oldest-Up-member election, and `auto-down`. | #717 c7794 |
## 2. Where the code is today
- **Metadata.** No code sets `ServerRedundancy.RedundancySupport` (`i=3709`), so it reads the SDK default. `Server.ServerRedundancy` is the base `ServerRedundancyType` and has no `ServerUriArray` (`i=11314`) (`docs/Redundancy.md:9`). Peers are published only in `Server.ServerArray` (`i=2254`), by appending to `IServerInternal.ServerUris` after start (`OpcUaApplicationHost.cs:378-414`, called at `:241`).
- **Self URI.** It comes from `OpcUa:ApplicationUri`, which defaults to `urn:OtOpcUa` (`OpcUaApplicationHost.cs:35`). If `ApplicationConfigPath` is set, the loaded XML wins (`:602-608`). docker-dev sets neither `OpcUa__ApplicationUri` nor `PeerApplicationUris` on central-1/2 (`docker-dev/docker-compose.yml:289-481`), so both centrals advertise `urn:OtOpcUa`. The seeded `ClusterNode.ApplicationUri` uses `urn:OtOpcUa:<NodeId>` (`docker-dev/seed/seed-clusters.sql:13`).
- **ServiceLevel.** `ServiceLevelCalculator.Compute` returns 240 + 10 for the Primary (`ServiceLevelCalculator.cs:44-64`). The standby therefore sits in the *healthy* band. `OpcUaPublishActor.RecomputeServiceLevel` feeds it (`OpcUaPublishActor.cs:1576-1636`), and the result is published through the #719-fixed retain/replay path (`:1468-1488`, `SdkServiceLevelPublisher.cs:36-60`).
- **Acquisition is role-independent.** Every driver node spawns its drivers and subscribes whatever its role (#717 c7794). Today Primary gating covers only writes, native acks, the alerts emit, alarm-history drain, historization capture and HistoryUpdate (`PrimaryGatePolicy.cs:21,56,97,155`; `docs/Redundancy.md:554-600`).
- **Data variables.** Every ordinary-tag data variable (raw tag, UNS reference, virtual tag, Calculation tag) is an `EquipmentVariableState` created at exactly one site (`OtOpcUaNodeManager.cs:4060`). Values are pushed into it with `PublishValue` (`EquipmentVariableState.cs:28-35`).
- **Alarm events.** Every condition event goes through `ReportConditionEvent` (`OtOpcUaNodeManager.cs:1376`) and then `ReportEventWithoutBlocking` (`:1507`). The callers are engine/driver projection (`:1254`, `:1341`), method transitions (`:2842`) and restore re-report (`:4659`). Server-object items get per-item, ACL-filtered dispatch (#586). Folder and direct items get per-item delivery (#826/#855). Refresh paths: `ConditionRefresh` (`:6586`), `RefreshDirectItems` (`:6974`) and the #854 cut. Model-change and audit events use `ReportToServerObject` (`:6060`), not this path.
- **Role snapshots are unordered.** `RedundancyStateActor` is a cluster singleton. It publishes `RedundancyStateChanged(Nodes, CorrelationId)` on DPS, debounced at 250 ms and heartbeated every 10 s (`RedundancyStateActor.cs:25,33,105-113`). `AsOfUtc` is the *publisher's* wall clock (`:184`) and `CorrelationId` is random (`:110`). Subscribers replace their cached snapshot unconditionally (`OpcUaPublishActor.cs:1494-1498`, `DriverHostActor.cs:2555-2562`). After a singleton handover, a late heartbeat from the old incarnation can overwrite the new incarnation's snapshot. Nothing establishes the order, and there is no lease.
- **Config.** `ServerCluster.RedundancyMode` (None/Warm/Hot) exists in ConfigDb. It is CHECK-coupled to NodeCount (`OtOpcUaConfigDbContext.cs:109-111`; `DraftValidator.cs:958-962`) and travels in the artifact's `Clusters` array (`ConfigComposer.cs:67`), but no runtime code reads it.
## 3. Contract per deployment shape
| Shape | `OpcUa:Redundancy:Mode` | `RedundancySupport` (i=3709) | `ServerRedundancy` type | `ServerUriArray` (i=11314) | `ServerArray` (i=2254) | Standby behaviour |
|---|---|---|---|---|---|---|
| Today / not opted in | `Unset` (default) | SDK default (unchanged) | `ServerRedundancyType` (2034) | absent | self + peers (unchanged) | none; Secondary serves Good at 240 (unchanged) |
| Standalone | `None` | `None` (0) | `ServerRedundancyType` (2034) | absent | self only | never; always serves |
| Pair | `Warm` | `Warm` (2) | `NonTransparentRedundancyType` (2039) | `[effectiveSelfUri, peer…]`, read-only String[], self first (decision #155, `docs/v2/plan.md:930`) | unchanged | §4 |
- The metadata is **startup-static**. The graph is built before node-manager registration through
`StandardServer.CreateMainNodeManagerFactory` + `ConfigurationNodeManager.AddBehaviourToPredefinedNode`. That
route is spike-proven on SDK 1.5.378.106 (#717 c7791) and becomes `AddBehaviourToPredefinedNodeAsync` on 2.0.1.
The passive predefined `i=11314` the SDK visits later must resolve to the same constructed instance, or the wire
value is null (c7791). Changing mode or peers requires a restart.
- `effectiveSelfUri` is the **effective** `ApplicationConfiguration.ApplicationUri` after any XML load, never the
options default (c7787).
- `Hot` is **not advertisable**: continuous acquisition alone does not meet Part 4 §6.6.2.4 Hot (c7794).
`Mode=Hot` fails host start.
- Startup validation (`ValidateOnStart`) runs for `Warm` and fails host start when any of these holds: there is no
peer; a peer URI equals the self URI; a URI is duplicated; the `driver` role is missing.
- Deploy-time cross-check: if the artifact's `ServerCluster.RedundancyMode` for this node's cluster disagrees
with the local mode (`NodeCount=1/None` against local `Warm`, or the reverse), the node logs an Error and records
the metric `otopcua.redundancy.mode_mismatch`. The node keeps running in its local mode. Local config is the
authority, because it is the only value available before SDK start.
## 4. Warm role contract
### 4.1 Role verdict (who is Active)
A Warm node is **Active** iff all of the following hold. Otherwise it is **Standby**.
1. The local `SelfMember` is Up and `EndpointListening` is true (#762).
2. The node's **own** `Cluster.State` names it the oldest Up `driver` member. This is the same function the
singleton uses (`RedundancyStateActor.SelectOldestUpMemberOfRole`, `:172`), so the verdict cannot drift from
singleton placement (D7).
3. The latest **accepted** snapshot (§4.2) names it `Primary`.
Any disagreement between (2) and (3) resolves to Standby. A Warning is logged if the disagreement lasts more than
two heartbeats (20 s). When the role is unknown — before the first accepted snapshot, or when the snapshot omits
this node — the node is **Standby**, whatever the member count. This is stricter than `PrimaryGatePolicy`'s
lone-node allow (`PrimaryGatePolicy.cs:21`): a lone node goes Active within one debounce (~250 ms) of its own
singleton's first publish. That gate is **not** changed for writes/acks (D7). The Warm verdict is a separate output.
**Promote while the Primary is unreachable (owner answer Q2, `OpcUa:Redundancy:PromoteWhilePrimaryUnreachable`,
default `true`).** A SIGKILLed Primary stays an Up-but-unreachable member until `auto-down` removes it (~25–30 s),
and the singleton usually died with it, so (2) and (3) would hold the survivor Standby for that whole window. With
the option on, (2) and (3) are evaluated with **unreachable** members excluded: (2′) self is the oldest Up `driver`
member among the members this node can reach, and (3′) the latest accepted snapshot names either self or an
**unreachable** member as `Primary`. This is the #672 pattern (`ContinuousHistorization:CaptureWhilePrimaryUnreachable`).
A node that has never accepted a snapshot is still Standby. The cost is dual-Active while a live Primary is merely
unreachable, and for the whole of a real partition.
Accepted trade: an `auto-down` partition can give two Active nodes, as it already does for the data-plane gate
(`docs/Redundancy.md` §Split-brain). For reads this is benign, because both nodes serve the same Good data.
### 4.2 Ordered snapshots (the revision problem)
`RedundancyStateChanged` gains an additive `Revision(PublisherUpNumber, IncarnationTick, Sequence)`:
- `PublisherUpNumber` is the `Member.UpNumber` of the node that hosts the singleton. The singleton always lives on
the oldest member, and every surviving member has a larger up-number than a departed oldest one. The value is
therefore monotonic across handovers within one cluster incarnation.
- `IncarnationTick` is `Environment.TickCount64` at singleton `PreStart`. It is monotonic for a singleton that
restarts in the same process.
- `Sequence` increments on every publish, including heartbeats.
Subscribers (`OpcUaPublishActor`, `DriverHostActor`) accept a snapshot only if its revision is lexicographically
greater than the last accepted one. Anything else is dropped and counted in
`otopcua.redundancy.snapshot_rejected{reason}`. A subscriber cannot outlive its cluster incarnation: a removed node
must restart its `ActorSystem` to rejoin. The plan pins this assumption with a test. A snapshot **without** a
revision (from a pre-#717 publisher during a rolling upgrade) is accepted for the existing gates but can never make
a Warm node Active. Warm therefore requires both pair nodes to be upgraded before it is turned on.
There is no time lease beyond this. Liveness comes from (2), which reads live gossip, and the existing 30 s
staleness input to ServiceLevel. Demoting an Active node on snapshot staleness alone was rejected: the singleton
lives on the Active node itself, so staleness there means a local fault, and demoting would turn it into a pair-wide
data outage.
### 4.3 ServiceLevel bands (Part 4 §6.6.2.4.2)
| Node state (Warm) | Byte | Band |
|---|---|---|
| Down / Detached / endpoint failed | 0 | Maintenance (unchanged) |
| Boot, before first computed level | **1** (set in the startup graph; replaces SDK default 255) | NoData |
| Standby, degraded (stale or DB unreachable) | **50** | Degraded |
| Standby, healthy | **90** | Degraded |
| Active, critically degraded | 100 | Degraded (unchanged) |
| Active, stale | 200 | Healthy (unchanged) |
| Active, healthy | 250 | Healthy (unchanged: 240 + 10) |
Invariant: **every Standby level is below every level an Active node serving data can publish (≥ 100)**. A
"highest ServiceLevel" client therefore never prefers a standby over a data-serving Active node. `Unset` and `None`
keep `ServiceLevelCalculator.Compute` byte-for-byte.
### 4.4 Behaviour on the Standby, per service
"Ordinary tag" means the `Value` attribute of an `EquipmentVariableState`. The category is captured at item
creation from the node instance and the `AttributeId`, never from namespace or ClientHandle (c7853).
| Service | Standby behaviour | Status the client sees |
|---|---|---|
| Read (ordinary tag `Value`) | Projected. The stored value is kept internally and continues to update from acquisition. | `BadOutOfService`, `Value = null`, `ServerTimestamp = now`. Operation result Good. |
| Read (other attributes, condition children, ns=0 incl. ServiceLevel/ServerStatus/ServerRedundancy) | Unchanged | Good / as today |
| CreateMonitoredItems (ordinary tag) | Created normally (ACL unchanged). Initial value is projected. | Item result Good; first notification `BadOutOfService`/null |
| Existing data items at demotion | One `BadOutOfService`/null notification is queued, ignoring filters. Later samples project to the same value, so the SDK's change filter emits nothing further. **D4:** any Good ordinary-tag notification that would be first-delivered after the demotion step is rewritten to `BadOutOfService`/null at Publish/Republish (§4.6). | `BadOutOfService` |
| Write (ordinary tag `Value`) | **Refused synchronously under Warm only (owner answer Q1).** The node manager refuses the write before it reaches the driver; nothing is reverted and no device is touched. `Unset`/`None` keep today's #5 self-correction (synchronous Good, then revert + audit) off-Primary (D7). | `BadInvalidState` |
| HistoryRead | Unchanged. Served from the shared backend, which is not live acquisition. | as today |
| HistoryUpdate | Unchanged | `BadInvalidState` off-Primary (#674) |
| Browse / TranslateBrowsePaths / RegisterNodes | Unchanged | as today |
| Call: Part 9 methods | **Refused under Warm (owner answer Q4).** Every Part 9 condition method (Acknowledge, Confirm, AddComment, Enable/Disable, the shelving methods) on a native or scripted condition is refused before it changes any state. `Unset`/`None` keep today's behaviour: native ack `BadInvalidState` off-Primary, scripted ack/shelve accepted (D7). | `BadInvalidState` |
| Event subscriptions (Server object, folders, direct) | Stay established, in Reporting mode, with the ACL unchanged | — |
| Model-change / audit events | **Not suppressed.** They are not alarm events, and browse consistency needs them. | — |
| Session / secure channel / ServerStatus.State | Unchanged (`Running`) | — |
### 4.5 Alarms and events on the Standby
- **Suppression point.** `ReportConditionEvent` is split into *stamp* and *deliver*. Stamp sets EventId, Time and
ReceiveTime, and runs `ClearChangeMasks`. Deliver builds the snapshot and calls `ReportEventWithoutBlocking`. On
the Standby only *stamp* runs. Condition node state therefore stays current, and a later refresh carries a valid,
ackable EventId. Because suppression sits before snapshot construction and before every SDK field projection, it
covers the Server-object, folder and direct paths, ACL on or off, by construction. Overflow, filtered retain and
the #838 deferral queue never see a suppressed event. The `RingEventQueueFactory` queue is **not** used as the
gate (D6).
- **Boundary.** The decision is made at report time. An event whose report ran while Active is delivered even if
delivery finishes after demotion: deferred (#838) or already in an item queue. This matches the spike's
observed admission boundary (c7805). Republish of already-built event messages is unchanged.
- **Client ConditionRefresh / ConditionRefresh2 on the Standby (D5)** run the existing paths unchanged: Server
object (#854 cut), `RefreshDirectItems` (#855), with ACL filtering as today. The replay is RefreshStart, the
current retained conditions, then RefreshEnd.
- **Promotion refresh.** On Standby → Active, the server runs a refresh on **every** live event item: Server-object
items, direct items and folder items. The two refresh entry points are reused, so ACL decisions and the #854/#855
cut apply. Clients see RefreshStart, retained conditions, RefreshEnd, then new events. This is spike-proven on
1.5 (c7805). A condition that went active **and** stopped being retained entirely while the node was Standby is
not replayed. That is standard refresh semantics, and the transition is not historized twice, because alarm
history is Primary-gated (`docs/Redundancy.md:572-573`).
### 4.6 Strict first delivery (D4)
The item-level projection (§4.4) stops new Good samples. It cannot reach samples already queued in an item, nor
`NotificationMessage`s the subscription has prebuilt or cached (c7846, c7850). For those, the design uses the
mechanism that passed the provenance spike (c7851, 66 assertions) and the delivery-history spike (c7852,
53 assertions):
1. **Provenance.** Ordinary-tag data items are created through a custom sampled item. Its per-value `Publish`
stamps each newly created `MonitoredItemNotification` with an immutable `(NodeId, AttributeId, Category)`. The
stamp survives handle modification, item deletion and reuse.
2. **Delivery history.** `OtOpcUaSdkServer` overrides `PublishAsync` and `RepublishAsync`, calls base first, and
records **one first-delivery choice per cached message object**. The association is weak and keyed by object;
cached SDK objects are never mutated.
- If the node is Active at first delivery, the original message is the choice.
- If the node is Standby, a detached clone is the choice, with every `OrdinaryTag` notification replaced by
`BadOutOfService`/null.
- A Republish returns the recorded choice. First delivery *through* Republish is decided the same way.
- A short lock orders the choice against the role flip. No lock spans an await.
3. **Out of scope of the rewrite**, by D4: messages already in flight before the demotion step, and Republish of
messages first delivered while Active. Unknown-origin notifications are not rewritten; there is no implicit
policy (c7853).
### 4.7 Transition sequencing
One actor, `OpcUaPublishActor`, owns the verdict, the ServiceLevel publish and a new `IStandbyProjection` sink
(in `Commons.OpcUa`, bound late like `IServiceLevelPublisher`). Each transition runs as one serialized handler, in
this order.
**Promotion (Standby → Active)**
1. Open the read projection.
2. For each live ordinary-tag item, queue the current stored value, ignoring filters. The precedent is the queue
pattern at `OtOpcUaNodeManager.cs:7303`.
3. Switch the delivery-history choice to Active.
4. Un-suppress alarm delivery.
5. Run the promotion refresh (§4.5).
6. Publish the Active ServiceLevel.
**Demotion (Active → Standby)**
1. Publish the Standby ServiceLevel.
2. Switch the delivery-history choice to Standby. This is the D4 boundary.
3. Suppress alarm delivery.
4. Close the read projection.
5. Queue `BadOutOfService` to each live ordinary-tag item.
Invariant: **an Active-band ServiceLevel is never visible while the projection is closed.** If the ServiceLevel
publish fails (#719 retry path), a promotion stops before step 6 and retries. A demotion continues anyway: failing
safe means degrading the data.
### 4.8 Standalone (`None`) and `Unset`
`None` never projects, never suppresses and never refreshes. It advertises `RedundancySupport=None` with no
`ServerUriArray`, and uses today's ServiceLevel. `Unset` is byte-for-byte today's server, including the documented
unmet A4/A5b gates.
## 5. ScadaBridge impact (cross-repo, blocking for any Warm flip)
ScadaBridge consumes this server as an OPC UA client, through `RealOpcUaClient` and `DataConnectionActor`.
- **Failover is connection-driven, not ServiceLevel-driven.** ScadaBridge swaps primary to backup only after
`FailoverRetryCount` consecutive *unstable disconnects*
(`../ScadaBridge/src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Actors/DataConnectionActor.cs:655-690`;
`RealOpcUaClient.cs` sits in that project's `Adapters/`).
`BadOutOfService` is not a connection-level status (`:1974-1983`), so it maps to plain Bad quality, and since
ScadaBridge#112 a Bad-with-null update keeps the last-known value. Nothing in ScadaBridge reads `ServiceLevel`,
`RedundancySupport` or `ServerUriArray`.
- **Consequence.** A ScadaBridge connection that lands on the Standby will sit on Bad quality indefinitely on a
healthy session, and never fail over. Today the same connection gets Good data at 240. Warm is therefore an
**outage for ScadaBridge** unless ScadaBridge becomes ServiceLevel-aware: monitor `i=2267` and treat a Degraded
band (< 200) sustained for N s, while the other endpoint reports a higher level, as a failover trigger. That
change must ship and be deployed first. It is filed as **ScadaBridge#138** (`cross-repo`, blocking); no tier sets
`Mode=Warm` until it is deployed there.
- **Alarms are compatible.** ScadaBridge already handles a RefreshStart/RefreshEnd replay as a snapshot
(`RealOpcUaClient.cs:72`) and triggers its own ConditionRefresh on (re)subscribe (`:1179-1193`). Under D5 that
refresh returns retained conditions on the Standby too. The promotion refresh arrives as an unsolicited
Start/End pair on existing items; this needs a ScadaBridge-side test.
- **Status mapping is compatible.** ScadaBridge#117 maps by severity bits, so `BadOutOfService` is Bad.
## 6. Configuration surface
| Key | Default | Notes |
|---|---|---|
| `OpcUa:Redundancy:Mode` | `Unset` | `Unset` / `None` / `Warm`. `Hot` and unknown values fail host start. Startup-static. Flip **both** pair nodes in one window, after both run a revision-capable build (§4.2). |
| `OpcUa:Redundancy:PromoteWhilePrimaryUnreachable` | `true` | Warm only. Lets the survivor go Active while the Primary is unreachable but not yet downed (§4.1, owner answer Q2). |
| `OpcUa:PeerApplicationUris` | `[]` | Existing key, now also the `ServerUriArray` peer source. Required (≥ 1) for `Warm`, must be empty for `None`. |
| `OpcUa:ApplicationUri` | `urn:OtOpcUa` | Must be unique within the pair under `Warm` (validated against the effective config). |
There are no ConfigDb schema changes. `ServerCluster.RedundancyMode` is only cross-checked (§3).
## 7. Observability
- `otopcua.redundancy.warm_role`: gauge. 1 = Active, 0 = Standby, −1 = not Warm.
- `otopcua.redundancy.warm_transition{direction,reason}`: counter. Reasons: `membership`, `snapshot`,
`endpoint`, `boot`.
- `otopcua.redundancy.snapshot_rejected{reason=older_revision|unrevisioned}`: counter.
- `otopcua.redundancy.mode_mismatch`: counter (§3).
- `otopcua.opcua.standby.projected_notifications`: counter. Counts D4 rewrites at Publish/Republish.
- `otopcua.opcua.standby.suppressed_alarm_events`: counter.
- Logs:
- Information per transition, naming the revision and the verdict inputs.
- Warning when membership and snapshot disagree for more than 20 s.
- A boot banner line with mode, effective self URI and peers.
- `otopcua-cli redundancy` already reads `i=3709`, `i=11314` and `i=2267`.
## 8. Explicitly out of scope
- Hot (and Transparent) redundancy.
- Dynamic peer membership. Peers are static config.
- Changing the election (oldest Up driver member), `auto-down`, or the write / native-ack / HistoryUpdate /
alarm-drain / historization gates.
- Stopping acquisition on the Standby.
- TransferSubscriptions across the pair. Non-transparent means the client re-creates its subscriptions.
- CTT (G8) and production-client cutover (G9). Hermetic and live-rig passes are not acceptance.
- Durable subscription restore.
- Sequence-number wrap.
- Encoded-byte fidelity of cloned payloads beyond the plan's bounded matrix (c7890).
## 9. Owner answers (2026-11-13, #717)
The draft carried six open questions. The owner answered them on 2026-11-13 and approved the spec and plan
(`2be43aa9`). The answers are applied in the sections above.
1. **Standby writes.** Refuse synchronously with `BadInvalidState` under `Warm` only (§4.4). `Unset`/`None` keep the
#5 optimistic Good + revert.
2. **Crash-failover gap.** Yes: the survivor may promote while the Primary is unreachable, behind
`OpcUa:Redundancy:PromoteWhilePrimaryUnreachable` (default on) (§4.1). Dual-Active during a real partition is accepted.
3. **Standby status code.** `BadOutOfService`, not the spike's `BadNoCommunication`, so a standby is distinguishable
from real device comms loss without reading ServiceLevel. Re-proven on 2.0.1 in T0.
4. **Scripted Part 9 methods on the Standby.** Refuse with `BadInvalidState` under `Warm` (§4.4).
5. **ConfigDb `Hot`.** Leave the CHECK; rely on the §3 mismatch Error. No migration.
6. **Bands.** Accepted as drafted: Standby 90 (healthy) / 50 (degraded), boot 1 (§4.3).
## 10. What must be re-proven on SDK 2.0.1
The spikes ran on **1.5.378.106**. The repo now pins **2.0.1** (`Directory.Packages.props:129-135`). The 2.0.1 XML
docs confirm that these members still exist:
- `StandardServer.CreateMainNodeManagerFactory`
- `ConfigurationNodeManager.AddBehaviourToPredefinedNodeAsync`, now **async**
- `NonTransparentRedundancyState.ServerUriArray`, now in `Opc.Ua.Core.Types`
- `StandardServer.PublishAsync` / `RepublishAsync`, whose signatures now carry `RequestLifetime`
- `CreateSubscriptionManager`
- `BaseVariableState.OnSimpleReadValue`, plus new `OnSimpleReadValueAsync` / `OnReadValueAsync`
- `ReadValueAttribute`
- `IServerInternal.ConditionRefresh2`
- a new `MonitoredItemFactory` / `MonitoredItemCreateDecision` creation hook and an
`IMonitoredItemTransferCoordinator`
Existence is not behaviour. Plan T0 re-proves, on 2.0.1 over the wire:
- (a) the metadata graph, including the passive-`i=11314` resolution;
- (b) that **every** value read path reaches the per-tag projection: Read, initial sample, change fan-out,
ResendData, size-1 queue and AggregateFilter. In particular, the new async read callbacks must not bypass a sync
`OnSimpleReadValue`; if they do, the hook moves to a `ReadValueAttribute` override on `EquipmentVariableState`;
- (c) provenance through the 2.0.1 creation hook, which replaces the 1.5 manager-subclass route, including
transfer/restore;
- (d) the Publish/Republish choice with the new signatures;
- (e) suppression and promotion refresh through the product's #854/#855 per-item paths, which did not exist when
the 1.5 event spike ran.
**Result (2026-11-13):** (a) and (b) are re-proven on 2.0.1. The metadata graph uses `IPredefinedNodeSubtypeReplacer`
in `OnNodeManagerStartedAsync`, which is simpler than the factory route. (c) and (d) **fail as written in §4.6**:
2.0.1 clones the cached message on every delivery and pools notification payloads, so neither object-keyed
provenance nor an object-keyed choice can work. An alternative mechanism passed the spike and awaits the owner's
decision. See `docs/plans/evidence/2026-11-13-717-sdk2/RESULTS.md`.