Files
lmxopcua/tests/Server
Joseph Doherty 18f8eb5d2f feat(address-space): server-side array writes gated per driver capability (#610)
Array nodes were forced read-only for every driver. A new single authority,
Core.Abstractions DriverArrayWriteSupport, says which (driver, element type)
pairs encode a whole-array write: Modbus (Coils / numeric HoldingRegisters),
S7 (Byte/Int16/UInt16/Int32/UInt32/Float32), OpcUaClient (pass-through) and
Galaxy (Boolean/Int32/Int64/Float/Double/String/DateTime). Everything else
stays read-only, so the server never advertises a write the driver refuses.

- Composer derives RawTagPlan.ArrayWritable + UnsReferenceVariable
  .BackingArrayWritable at compose time (both seams, byte-parity); the
  applier's one writability rule is Writable && (!IsArray || ArrayWritable)
  for materialise and surgical paths, raw and UNS alike.
- ArrayWritable is on the classifier's surgical raw-tag whitelist and
  mirrored on the UNS record (UnsReferenceBackingParityTests updated).
- Node manager refuses a wrong-length / non-array value on an array node
  (BadTypeMismatch) and any IndexRange write (BadWriteNotSupported) inline,
  before dispatch; WriteOperate/ACL gates and the revert are unchanged.
- Per-driver parity tests pin the table against the real Modbus write path,
  S7 EncodeArrayBlock and Galaxy MxValueEncoder (UInt32/UInt64 excluded:
  array covariance reinterprets their bits).
- Over-the-wire proof in OpcUaServer.IntegrationTests (ArrayWriteWireTests).
- ValueRank > 1 documented as out of scope by decision (docs/Uns.md).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 07:39:05 -04:00
..