IEC 61131-3 TIME/TOD now surface as TimeSpan (UA Duration); DATE/DT surface as DateTime (UTC). The wire form stays UDINT — AdsTwinCATClient post-processes raw values in ReadValueAsync and OnAdsNotificationEx, and accepts native CLR types in ConvertForWrite. Added Duration to DriverDataType (back-compat: existing switches default to BaseDataType for unknown enum values) and mapped it to DataTypeIds.Duration in DriverNodeManager. Closes #306