The original three-stage design (probe / driver-loopback / forward- bridge) only proved driver-write → server-read. It missed: - OPC UA write → server → driver → PLC (the reverse direction) - server-side data-change notifications actually firing (a stale subscription can still let a read-after-the-fact return the new value and look fine) Extend _common.ps1 with two helpers: - Test-OpcUaWriteBridge: otopcua-cli write the NodeId -> wait 3s -> driver CLI read the PLC side, assert equality. - Test-SubscribeSeesChange: Start-Process otopcua-cli subscribe in the background with --duration N, settle 2s, driver-side write, wait for the subscription window to close, assert captured stdout contains the new value. Wire both into test-modbus / test-abcip / test-ablegacy / test-s7 / test-focas / test-twincat after the existing forward-bridge stage. Update README to describe the five-stage design + note that the published NodeId must be writable for stages 4 + 5. Also prepend UTF-8 BOM to every script in scripts/e2e so Windows PowerShell 5.1 parsers agree on em-dash byte sequences the way PowerShell 7 already does. The scripts still #Requires -Version 7.0 — the BOM is purely defensive for IDE / CI step parsers. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
97 lines
3.2 KiB
PowerShell
97 lines
3.2 KiB
PowerShell
#Requires -Version 7.0
|
|
<#
|
|
.SYNOPSIS
|
|
End-to-end CLI test for the FOCAS (Fanuc CNC) driver.
|
|
|
|
.DESCRIPTION
|
|
**Hardware-gated.** There is no public FOCAS simulator; the driver's
|
|
FwlibFocasClient P/Invokes Fanuc's licensed Fwlib32.dll. Against a dev
|
|
box without the DLL on PATH the test will skip with a clear message.
|
|
Against a real CNC with the DLL present it runs probe / driver-loopback /
|
|
server-bridge the same way the other scripts do.
|
|
|
|
Set FOCAS_TRUST_WIRE=1 when -CncHost points at a real CNC to un-gate.
|
|
|
|
.PARAMETER CncHost
|
|
IP or hostname of the CNC. Default 127.0.0.1 — override for real runs.
|
|
|
|
.PARAMETER CncPort
|
|
FOCAS TCP port. Default 8193.
|
|
|
|
.PARAMETER Address
|
|
FOCAS address to exercise. Default R100 (PMC R-file register).
|
|
|
|
.PARAMETER OpcUaUrl
|
|
OtOpcUa server endpoint.
|
|
|
|
.PARAMETER BridgeNodeId
|
|
NodeId at which the server publishes the Address.
|
|
#>
|
|
|
|
param(
|
|
[string]$CncHost = "127.0.0.1",
|
|
[int]$CncPort = 8193,
|
|
[string]$Address = "R100",
|
|
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
|
|
[Parameter(Mandatory)] [string]$BridgeNodeId
|
|
)
|
|
|
|
$ErrorActionPreference = "Stop"
|
|
. "$PSScriptRoot/_common.ps1"
|
|
|
|
if (-not ($env:FOCAS_TRUST_WIRE -eq "1" -or $env:FOCAS_TRUST_WIRE -eq "true")) {
|
|
Write-Skip "FOCAS_TRUST_WIRE not set — no public simulator exists (task #222 tracks the lab rig). Set =1 when -CncHost points at a real CNC with Fwlib32.dll on PATH."
|
|
exit 0
|
|
}
|
|
|
|
$focasCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli" `
|
|
-ExeName "otopcua-focas-cli"
|
|
$opcUaCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
|
|
-ExeName "otopcua-cli"
|
|
|
|
$commonFocas = @("-h", $CncHost, "-p", $CncPort)
|
|
$results = @()
|
|
|
|
$results += Test-Probe `
|
|
-Cli $focasCli `
|
|
-ProbeArgs (@("probe") + $commonFocas + @("-a", $Address, "--type", "Int16"))
|
|
|
|
$writeValue = Get-Random -Minimum 1 -Maximum 9999
|
|
$results += Test-DriverLoopback `
|
|
-Cli $focasCli `
|
|
-WriteArgs (@("write") + $commonFocas + @("-a", $Address, "-t", "Int16", "-v", $writeValue)) `
|
|
-ReadArgs (@("read") + $commonFocas + @("-a", $Address, "-t", "Int16")) `
|
|
-ExpectedValue "$writeValue"
|
|
|
|
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
|
|
$results += Test-ServerBridge `
|
|
-DriverCli $focasCli `
|
|
-DriverWriteArgs (@("write") + $commonFocas + @("-a", $Address, "-t", "Int16", "-v", $bridgeValue)) `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-ExpectedValue "$bridgeValue"
|
|
|
|
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
|
|
$results += Test-OpcUaWriteBridge `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $focasCli `
|
|
-DriverReadArgs (@("read") + $commonFocas + @("-a", $Address, "-t", "Int16")) `
|
|
-ExpectedValue "$reverseValue"
|
|
|
|
$subValue = Get-Random -Minimum 30000 -Maximum 32766
|
|
$results += Test-SubscribeSeesChange `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $focasCli `
|
|
-DriverWriteArgs (@("write") + $commonFocas + @("-a", $Address, "-t", "Int16", "-v", $subValue)) `
|
|
-ExpectedValue "$subValue"
|
|
|
|
Write-Summary -Title "FOCAS e2e" -Results $results
|
|
if ($results | Where-Object { -not $_.Passed }) { exit 1 }
|