Files
lmxopcua/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Ab.Transport/Pccc/PcccServices.cs
T
Joseph Doherty 004c09fa13 fix(ablegacy): an Unsupported the device replied with is an answered refusal, not a local one
Review I2: Driver.Ab.Transport raises statuses that came off the wire in an
Execute PCCC reply (envelope CIP status, PCCC STS) as AbDeviceReplyException.
AbLegacy's IsLocalRefusal now excludes it, and the new IsAnsweredRefusal (used
by the read, write, probe and indirect-index paths) counts a wire Unsupported -
CIP 0x08/0x1C/0x20 on the envelope, STS 0x10 - as answered: per-tag
BadNotSupported, Healthy, LastSuccessfulRead advanced. Before, they landed in
the 'refused before the wire' neutral class. Pre-wire refusals are unchanged
(still neutral). A socket test covers all four codes (red before); transport
tests pin the marker and a pre-wire builder refusal as the positive control.
The AbCip Forward Open BadConnection path is untouched.

Refs #747
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:21:42 -04:00

139 lines
7.8 KiB
C#

using ZB.MOM.WW.OtOpcUa.Driver.Ab.Transport.Cip;
using ZB.MOM.WW.OtOpcUa.Driver.Ab.Transport.Wire;
namespace ZB.MOM.WW.OtOpcUa.Driver.Ab.Transport.Pccc;
/// <summary>Pure builders/parsers for Execute PCCC (CIP 0x4B on class 0x67) carrying SLC/MicroLogix
/// protected typed logical commands and PLC-5 range reads. Framing is taken from the golden captures.
/// The Execute PCCC request is sent bare (no Unconnected Send, no route) per the captures.</summary>
public static class PcccServices
{
/// <summary>Largest data byte count one typed read/write may carry (single-byte count on the wire).</summary>
public const int MaxDataBytes = 236;
/// <summary>True: PLC-5 range READ (cmd 0x0F fnc 0x01) is capture-verified.</summary>
public static bool Plc5Verified { get; } = true;
/// <summary>False: no PLC-5 write capture exists, so no PLC-5 write builder ships.</summary>
public static bool Plc5WriteVerified { get; } = false;
/// <summary>Requestor vendor id the native transport puts in Execute PCCC: libplctag's, from the captures
/// (<c>07 3D F3 45 43 50 21</c> in <c>slc500-read-n7.hex</c>).</summary>
/// <remarks>Not the CIP originator vendor (<see cref="ConnectionOptions.VendorId"/>). ab_server answers every
/// PCCC request with this fixed requestor id (<c>PCCC_RESP_PREFIX</c> in its <c>pccc.c</c>) instead of
/// echoing the request's, while real controllers echo whatever was sent. Sending libplctag's identity is
/// the only choice that lets the echo check in <see cref="ParseReply"/> pass against both (found by
/// the slc500 simulator: with the 0x1337 originator identity every native PCCC reply was BadReply).</remarks>
public const ushort RequestorVendor = 0xF33D;
/// <summary>Requestor serial number paired with <see cref="RequestorVendor"/> (libplctag's, from the captures).</summary>
public const uint RequestorSerial = 0x21504345;
/// <summary>Wraps a PCCC command in Execute PCCC: <c>4B 02 20 67 24 01</c> + requestor id (7, vendor, serial) + PCCC.</summary>
/// <param name="requestorVendor">The requestor vendor id.</param>
/// <param name="requestorSerial">The requestor serial number.</param>
/// <param name="pccc">The PCCC command bytes to wrap.</param>
/// <returns>The encoded Execute PCCC CIP request.</returns>
public static byte[] ExecutePccc(ushort requestorVendor, uint requestorSerial, ReadOnlySpan<byte> pccc) =>
new CipWriter().U8(0x4B).U8(2).U8(0x20).U8(0x67).U8(0x24).U8(0x01)
.U8(7).U16(requestorVendor).U32(requestorSerial).Bytes(pccc).ToArray();
private static void Field(CipWriter w, int v)
{
if (v < 0) throw new AbTransportException(AbStatus.OutOfBounds, $"Negative PCCC field {v}.");
if (v > ushort.MaxValue) throw new AbTransportException(AbStatus.OutOfBounds, $"PCCC field {v} exceeds 65535.");
if (v < 0xFF) w.U8((byte)v); else w.U8(0xFF).U16((ushort)v);
}
private static void CheckCount(int n)
{
if (n < 0 || n > MaxDataBytes)
throw new AbTransportException(AbStatus.TooLarge, $"PCCC byte count {n} exceeds {MaxDataBytes}.");
}
private static void Logical(CipWriter w, PcccAddress a)
{
Field(w, a.EffectiveFileNumber);
w.U8(a.FileTypeCode);
Field(w, a.Element);
Field(w, a.ResolveSubElement().Word);
}
/// <summary>Protected typed logical read with 3 address fields (0x0F/0xA2).</summary>
/// <param name="tns">The transaction number.</param>
/// <param name="addr">The data-table address to read.</param>
/// <param name="byteCount">Number of bytes to read.</param>
/// <returns>The PCCC command bytes.</returns>
public static byte[] SlcTypedRead(ushort tns, PcccAddress addr, int byteCount)
{
CheckCount(byteCount);
var w = new CipWriter().U8(0x0F).U8(0).U16(tns).U8(0xA2).U8((byte)byteCount);
Logical(w, addr);
return w.ToArray();
}
/// <summary>Protected typed logical write with 3 address fields (0x0F/0xAA). SLC/MicroLogix/LogixPccc
/// only: it must not be used for PLC-5 (the family guard lives in the AbLegacy native runtime).</summary>
/// <param name="tns">The transaction number.</param>
/// <param name="addr">The data-table address to write.</param>
/// <param name="data">The bytes to write.</param>
/// <returns>The PCCC command bytes.</returns>
public static byte[] SlcTypedWrite(ushort tns, PcccAddress addr, ReadOnlySpan<byte> data)
{
CheckCount(data.Length);
var w = new CipWriter().U8(0x0F).U8(0).U16(tns).U8(0xAA).U8((byte)data.Length);
Logical(w, addr);
return w.Bytes(data).ToArray();
}
/// <summary>PLC-5 range read (0x0F/0x01), as captured from libplctag:
/// <c>offset u16 (0), totalTrans u16, levelMask u8 (0x06 = file+element), file*, element*, byteCount u8</c>.
/// <c>totalTrans</c> counts 16-bit WORDS (DF1 word range read; the capture shows 1 for one 2-byte N element).
/// Only N-file reads are capture-verified, other PLC-5 file types are unverified; sub-element addressing is not and throws Unsupported.</summary>
/// <param name="tns">The transaction number.</param>
/// <param name="addr">The data-table address to read.</param>
/// <param name="totalTrans">Total transaction size in 16-bit words.</param>
/// <param name="byteCount">Number of bytes to read.</param>
/// <returns>The PCCC command bytes.</returns>
public static byte[] Plc5RangeRead(ushort tns, PcccAddress addr, ushort totalTrans, int byteCount)
{
CheckCount(byteCount);
if (addr.ResolveSubElement().Word != 0)
throw new AbTransportException(AbStatus.Unsupported, "PLC-5 sub-element addressing is not capture-verified.");
var w = new CipWriter().U8(0x0F).U8(0).U16(tns).U8(0x01).U16(0).U16(totalTrans).U8(0x06);
Field(w, addr.EffectiveFileNumber);
Field(w, addr.Element);
return w.U8((byte)byteCount).ToArray();
}
/// <summary>Validates an Execute PCCC reply and returns the PCCC data bytes.</summary>
/// <param name="reply">The parsed CIP reply.</param>
/// <param name="expectedTns">The request's TNS; checked before STS so a stale error reply is BadReply.</param>
/// <param name="expectedRequestorId">Optional full echoed requestor id (length byte included) to compare.</param>
/// <returns>The PCCC data bytes following the reply header.</returns>
public static ReadOnlyMemory<byte> ParseReply(CipReply reply, ushort expectedTns, byte[]? expectedRequestorId = null)
{
if (reply.GeneralStatus != 0)
throw new AbDeviceReplyException(reply.Status, $"Execute PCCC CIP status 0x{reply.GeneralStatus:X2}.");
var r = new CipReader(reply.Data.Span);
var idLen = r.U8();
if (idLen < 1) throw new AbTransportException(AbStatus.BadReply, "Empty requestor id in PCCC reply.");
var idBody = r.Bytes(idLen - 1);
if (expectedRequestorId is not null
&& !(expectedRequestorId.Length == idLen && expectedRequestorId[0] == idLen
&& idBody.SequenceEqual(expectedRequestorId.AsSpan(1))))
throw new AbTransportException(AbStatus.BadReply, "PCCC reply requestor id does not match the request.");
var cmd = r.U8();
if (cmd != 0x4F)
throw new AbTransportException(AbStatus.BadReply, $"PCCC reply command 0x{cmd:X2} != 0x4F.");
var sts = r.U8();
var tns = r.U16();
if (tns != expectedTns)
throw new AbTransportException(AbStatus.BadReply, $"PCCC TNS {tns} != {expectedTns}.");
byte? ext = sts == 0xF0 ? r.U8() : null;
if (sts != 0)
throw new AbDeviceReplyException(AbStatusCodes.FromPccc(sts, ext),
$"PCCC STS 0x{sts:X2}{(ext is { } e ? $" EXT 0x{e:X2}" : "")}.");
return reply.Data[r.Position..];
}
}