Spec: per-shape contract (Unset/None/Warm), RedundancySupport + ServerUriArray graph, ServiceLevel bands, per-service standby behaviour, alarm suppression + ConditionRefresh (D5), strict first-delivery (D4), transition sequencing, ordered snapshot revisions, ScadaBridge impact, SDK 2.0.1 re-proof list, open questions. Plan: T0-T13 with wire tests, docker-dev live gate, rollout/rollback. Docs only. Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
316 lines
25 KiB
Markdown
316 lines
25 KiB
Markdown
# Warm non-transparent redundancy with a degraded standby (Gitea #717): design spec
|
||
|
||
Status: **DRAFT for owner approval.** No product code changes until this spec and the companion plan
|
||
(`2026-11-11-warm-redundancy-717-plan.md`) are approved. Parent gate: #615 (G8 CTT, G9 production-client
|
||
cutover). These stay open and separate from everything here.
|
||
|
||
## 1. Owner decisions this spec builds on (not re-opened)
|
||
|
||
| # | Decision | Source |
|
||
|---|---|---|
|
||
| D1 | Advertise **Warm** for a 2-node pair, with an explicit degraded-standby contract; **None** for standalone. | #717 c7796 |
|
||
| D2 | Standby ServiceLevel in the **degraded band 2–199**; ordinary tag Reads/subscriptions on the standby **degrade**, while internal acquisition continues. Today's Secondary serves live Good data at 240, so it cannot just be relabelled. | #717 c7796, c7801, c9329 |
|
||
| D3 | Event subscriptions stay established on the standby; **new** alarm events are suppressed there; current retained conditions are refreshed on promotion. | #717 c7804 |
|
||
| D4 | **Strict first delivery.** After demotion, any Publish response delivered for the first time must not contain Good ordinary-tag values. That includes samples queued before demotion and batches built before it. Republish history and responses already in flight are preserved. | #717 c7849 |
|
||
| D5 | A client-initiated ConditionRefresh on the Warm standby **returns its current retained conditions**. Only new alarm events are suppressed. | #717 c11362 (2026-11-11) |
|
||
| D6 | The queue-only spike gate must not be adopted unchanged, because of late-overflow and filtered-retain effects. Product alarm suppression happens **before** SDK event-field projection. Per-tag read projection is the recommended data seam. Every ACL, direct-item and Server-object refresh path needs coverage. Role snapshots need an ordered revision. | #717 c7812, c7853, issue body |
|
||
| D7 | Existing mutation and election policies are preserved: the write/native-ack/HistoryUpdate Primary gates, the oldest-Up-member election, and `auto-down`. | #717 c7794 |
|
||
|
||
## 2. Where the code is today
|
||
|
||
- **Metadata.** No code sets `ServerRedundancy.RedundancySupport` (`i=3709`), so it reads the SDK default. `Server.ServerRedundancy` is the base `ServerRedundancyType` and has no `ServerUriArray` (`i=11314`) (`docs/Redundancy.md:9`). Peers are published only in `Server.ServerArray` (`i=2254`), by appending to `IServerInternal.ServerUris` after start (`OpcUaApplicationHost.cs:378-414`, called at `:241`).
|
||
- **Self URI.** It comes from `OpcUa:ApplicationUri`, which defaults to `urn:OtOpcUa` (`OpcUaApplicationHost.cs:35`). If `ApplicationConfigPath` is set, the loaded XML wins (`:602-608`). docker-dev sets neither `OpcUa__ApplicationUri` nor `PeerApplicationUris` on central-1/2 (`docker-dev/docker-compose.yml:289-481`), so both centrals advertise `urn:OtOpcUa`. The seeded `ClusterNode.ApplicationUri` uses `urn:OtOpcUa:<NodeId>` (`docker-dev/seed/seed-clusters.sql:13`).
|
||
- **ServiceLevel.** `ServiceLevelCalculator.Compute` returns 240 + 10 for the Primary (`ServiceLevelCalculator.cs:44-64`). The standby therefore sits in the *healthy* band. `OpcUaPublishActor.RecomputeServiceLevel` feeds it (`OpcUaPublishActor.cs:1576-1636`), and the result is published through the #719-fixed retain/replay path (`:1468-1488`, `SdkServiceLevelPublisher.cs:36-60`).
|
||
- **Acquisition is role-independent.** Every driver node spawns its drivers and subscribes whatever its role (#717 c7794). Today Primary gating covers only writes, native acks, the alerts emit, alarm-history drain, historization capture and HistoryUpdate (`PrimaryGatePolicy.cs:21,56,97,155`; `docs/Redundancy.md:554-600`).
|
||
- **Data variables.** Every ordinary-tag data variable (raw tag, UNS reference, virtual tag, Calculation tag) is an `EquipmentVariableState` created at exactly one site (`OtOpcUaNodeManager.cs:4060`). Values are pushed into it with `PublishValue` (`EquipmentVariableState.cs:28-35`).
|
||
- **Alarm events.** Every condition event goes through `ReportConditionEvent` (`OtOpcUaNodeManager.cs:1376`) and then `ReportEventWithoutBlocking` (`:1507`). The callers are engine/driver projection (`:1254`, `:1341`), method transitions (`:2842`) and restore re-report (`:4659`). Server-object items get per-item, ACL-filtered dispatch (#586). Folder and direct items get per-item delivery (#826/#855). Refresh paths: `ConditionRefresh` (`:6586`), `RefreshDirectItems` (`:6974`) and the #854 cut. Model-change and audit events use `ReportToServerObject` (`:6060`), not this path.
|
||
- **Role snapshots are unordered.** `RedundancyStateActor` is a cluster singleton. It publishes `RedundancyStateChanged(Nodes, CorrelationId)` on DPS, debounced at 250 ms and heartbeated every 10 s (`RedundancyStateActor.cs:25,33,105-113`). `AsOfUtc` is the *publisher's* wall clock (`:184`) and `CorrelationId` is random (`:110`). Subscribers replace their cached snapshot unconditionally (`OpcUaPublishActor.cs:1494-1498`, `DriverHostActor.cs:2555-2562`). After a singleton handover, a late heartbeat from the old incarnation can overwrite the new incarnation's snapshot. Nothing establishes the order, and there is no lease.
|
||
- **Config.** `ServerCluster.RedundancyMode` (None/Warm/Hot) exists in ConfigDb. It is CHECK-coupled to NodeCount (`OtOpcUaConfigDbContext.cs:109-111`; `DraftValidator.cs:958-962`) and travels in the artifact's `Clusters` array (`ConfigComposer.cs:67`), but no runtime code reads it.
|
||
|
||
## 3. Contract per deployment shape
|
||
|
||
| Shape | `OpcUa:Redundancy:Mode` | `RedundancySupport` (i=3709) | `ServerRedundancy` type | `ServerUriArray` (i=11314) | `ServerArray` (i=2254) | Standby behaviour |
|
||
|---|---|---|---|---|---|---|
|
||
| Today / not opted in | `Unset` (default) | SDK default (unchanged) | `ServerRedundancyType` (2034) | absent | self + peers (unchanged) | none; Secondary serves Good at 240 (unchanged) |
|
||
| Standalone | `None` | `None` (0) | `ServerRedundancyType` (2034) | absent | self only | never; always serves |
|
||
| Pair | `Warm` | `Warm` (2) | `NonTransparentRedundancyType` (2039) | `[effectiveSelfUri, peer…]`, read-only String[], self first (decision #155, `docs/v2/plan.md:930`) | unchanged | §4 |
|
||
|
||
- The metadata is **startup-static**. The graph is built before node-manager registration through
|
||
`StandardServer.CreateMainNodeManagerFactory` + `ConfigurationNodeManager.AddBehaviourToPredefinedNode`. That
|
||
route is spike-proven on SDK 1.5.378.106 (#717 c7791) and becomes `AddBehaviourToPredefinedNodeAsync` on 2.0.1.
|
||
The passive predefined `i=11314` the SDK visits later must resolve to the same constructed instance, or the wire
|
||
value is null (c7791). Changing mode or peers requires a restart.
|
||
- `effectiveSelfUri` is the **effective** `ApplicationConfiguration.ApplicationUri` after any XML load, never the
|
||
options default (c7787).
|
||
- `Hot` is **not advertisable**: continuous acquisition alone does not meet Part 4 §6.6.2.4 Hot (c7794).
|
||
`Mode=Hot` fails host start.
|
||
- Startup validation (`ValidateOnStart`) runs for `Warm` and fails host start when any of these holds: there is no
|
||
peer; a peer URI equals the self URI; a URI is duplicated; the `driver` role is missing.
|
||
- Deploy-time cross-check: if the artifact's `ServerCluster.RedundancyMode` for this node's cluster disagrees
|
||
with the local mode (`NodeCount=1/None` against local `Warm`, or the reverse), the node logs an Error and records
|
||
the metric `otopcua.redundancy.mode_mismatch`. The node keeps running in its local mode. Local config is the
|
||
authority, because it is the only value available before SDK start.
|
||
|
||
## 4. Warm role contract
|
||
|
||
### 4.1 Role verdict (who is Active)
|
||
|
||
A Warm node is **Active** iff all of the following hold. Otherwise it is **Standby**.
|
||
|
||
1. The local `SelfMember` is Up and `EndpointListening` is true (#762).
|
||
2. The node's **own** `Cluster.State` names it the oldest Up `driver` member. This is the same function the
|
||
singleton uses (`RedundancyStateActor.SelectOldestUpMemberOfRole`, `:172`), so the verdict cannot drift from
|
||
singleton placement (D7).
|
||
3. The latest **accepted** snapshot (§4.2) names it `Primary`.
|
||
|
||
Any disagreement between (2) and (3) resolves to Standby. A Warning is logged if the disagreement lasts more than
|
||
two heartbeats (20 s). When the role is unknown — before the first accepted snapshot, or when the snapshot omits
|
||
this node — the node is **Standby**, whatever the member count. This is stricter than `PrimaryGatePolicy`'s
|
||
lone-node allow (`PrimaryGatePolicy.cs:21`): a lone node goes Active within one debounce (~250 ms) of its own
|
||
singleton's first publish. That gate is **not** changed for writes/acks (D7). The Warm verdict is a separate output.
|
||
|
||
Accepted trade: an `auto-down` partition can give two Active nodes, as it already does for the data-plane gate
|
||
(`docs/Redundancy.md` §Split-brain). For reads this is benign, because both nodes serve the same Good data.
|
||
|
||
### 4.2 Ordered snapshots (the revision problem)
|
||
|
||
`RedundancyStateChanged` gains an additive `Revision(PublisherUpNumber, IncarnationTick, Sequence)`:
|
||
|
||
- `PublisherUpNumber` is the `Member.UpNumber` of the node that hosts the singleton. The singleton always lives on
|
||
the oldest member, and every surviving member has a larger up-number than a departed oldest one. The value is
|
||
therefore monotonic across handovers within one cluster incarnation.
|
||
- `IncarnationTick` is `Environment.TickCount64` at singleton `PreStart`. It is monotonic for a singleton that
|
||
restarts in the same process.
|
||
- `Sequence` increments on every publish, including heartbeats.
|
||
|
||
Subscribers (`OpcUaPublishActor`, `DriverHostActor`) accept a snapshot only if its revision is lexicographically
|
||
greater than the last accepted one. Anything else is dropped and counted in
|
||
`otopcua.redundancy.snapshot_rejected{reason}`. A subscriber cannot outlive its cluster incarnation: a removed node
|
||
must restart its `ActorSystem` to rejoin. The plan pins this assumption with a test. A snapshot **without** a
|
||
revision (from a pre-#717 publisher during a rolling upgrade) is accepted for the existing gates but can never make
|
||
a Warm node Active. Warm therefore requires both pair nodes to be upgraded before it is turned on.
|
||
|
||
There is no time lease beyond this. Liveness comes from (2), which reads live gossip, and the existing 30 s
|
||
staleness input to ServiceLevel. Demoting an Active node on snapshot staleness alone was rejected: the singleton
|
||
lives on the Active node itself, so staleness there means a local fault, and demoting would turn it into a pair-wide
|
||
data outage.
|
||
|
||
### 4.3 ServiceLevel bands (Part 4 §6.6.2.4.2)
|
||
|
||
| Node state (Warm) | Byte | Band |
|
||
|---|---|---|
|
||
| Down / Detached / endpoint failed | 0 | Maintenance (unchanged) |
|
||
| Boot, before first computed level | **1** (set in the startup graph; replaces SDK default 255) | NoData |
|
||
| Standby, degraded (stale or DB unreachable) | **50** | Degraded |
|
||
| Standby, healthy | **90** | Degraded |
|
||
| Active, critically degraded | 100 | Degraded (unchanged) |
|
||
| Active, stale | 200 | Healthy (unchanged) |
|
||
| Active, healthy | 250 | Healthy (unchanged: 240 + 10) |
|
||
|
||
Invariant: **every Standby level is below every level an Active node serving data can publish (≥ 100)**. A
|
||
"highest ServiceLevel" client therefore never prefers a standby over a data-serving Active node. `Unset` and `None`
|
||
keep `ServiceLevelCalculator.Compute` byte-for-byte.
|
||
|
||
### 4.4 Behaviour on the Standby, per service
|
||
|
||
"Ordinary tag" means the `Value` attribute of an `EquipmentVariableState`. The category is captured at item
|
||
creation from the node instance and the `AttributeId`, never from namespace or ClientHandle (c7853).
|
||
|
||
| Service | Standby behaviour | Status the client sees |
|
||
|---|---|---|
|
||
| Read (ordinary tag `Value`) | Projected. The stored value is kept internally and continues to update from acquisition. | `BadNoCommunication`, `Value = null`, `ServerTimestamp = now`. Operation result Good. |
|
||
| Read (other attributes, condition children, ns=0 incl. ServiceLevel/ServerStatus/ServerRedundancy) | Unchanged | Good / as today |
|
||
| CreateMonitoredItems (ordinary tag) | Created normally (ACL unchanged). Initial value is projected. | Item result Good; first notification `BadNoCommunication`/null |
|
||
| Existing data items at demotion | One `BadNoCommunication`/null notification is queued, ignoring filters. Later samples project to the same value, so the SDK's change filter emits nothing further. **D4:** any Good ordinary-tag notification that would be first-delivered after the demotion step is rewritten to `BadNoCommunication`/null at Publish/Republish (§4.6). | `BadNoCommunication` |
|
||
| Write | **Unchanged (D7):** the existing gate rejects off-Primary through the #5 self-correction (synchronous Good, then revert + audit). Under Warm the revert is invisible because the value is projected Bad anyway. See open question Q1. | as today |
|
||
| HistoryRead | Unchanged. Served from the shared backend, which is not live acquisition. | as today |
|
||
| HistoryUpdate | Unchanged | `BadInvalidState` off-Primary (#674) |
|
||
| Browse / TranslateBrowsePaths / RegisterNodes | Unchanged | as today |
|
||
| Call: Part 9 methods | Unchanged (D7): native ack `BadInvalidState` off-Primary; scripted ack/shelve accepted. The resulting condition event counts as a new alarm event and is suppressed (§4.5). See Q4. | as today |
|
||
| Event subscriptions (Server object, folders, direct) | Stay established, in Reporting mode, with the ACL unchanged | — |
|
||
| Model-change / audit events | **Not suppressed.** They are not alarm events, and browse consistency needs them. | — |
|
||
| Session / secure channel / ServerStatus.State | Unchanged (`Running`) | — |
|
||
|
||
### 4.5 Alarms and events on the Standby
|
||
|
||
- **Suppression point.** `ReportConditionEvent` is split into *stamp* and *deliver*. Stamp sets EventId, Time and
|
||
ReceiveTime, and runs `ClearChangeMasks`. Deliver builds the snapshot and calls `ReportEventWithoutBlocking`. On
|
||
the Standby only *stamp* runs. Condition node state therefore stays current, and a later refresh carries a valid,
|
||
ackable EventId. Because suppression sits before snapshot construction and before every SDK field projection, it
|
||
covers the Server-object, folder and direct paths, ACL on or off, by construction. Overflow, filtered retain and
|
||
the #838 deferral queue never see a suppressed event. The `RingEventQueueFactory` queue is **not** used as the
|
||
gate (D6).
|
||
- **Boundary.** The decision is made at report time. An event whose report ran while Active is delivered even if
|
||
delivery finishes after demotion: deferred (#838) or already in an item queue. This matches the spike's
|
||
observed admission boundary (c7805). Republish of already-built event messages is unchanged.
|
||
- **Client ConditionRefresh / ConditionRefresh2 on the Standby (D5)** run the existing paths unchanged: Server
|
||
object (#854 cut), `RefreshDirectItems` (#855), with ACL filtering as today. The replay is RefreshStart, the
|
||
current retained conditions, then RefreshEnd.
|
||
- **Promotion refresh.** On Standby → Active, the server runs a refresh on **every** live event item: Server-object
|
||
items, direct items and folder items. The two refresh entry points are reused, so ACL decisions and the #854/#855
|
||
cut apply. Clients see RefreshStart, retained conditions, RefreshEnd, then new events. This is spike-proven on
|
||
1.5 (c7805). A condition that went active **and** stopped being retained entirely while the node was Standby is
|
||
not replayed. That is standard refresh semantics, and the transition is not historized twice, because alarm
|
||
history is Primary-gated (`docs/Redundancy.md:572-573`).
|
||
|
||
### 4.6 Strict first delivery (D4)
|
||
|
||
The item-level projection (§4.4) stops new Good samples. It cannot reach samples already queued in an item, nor
|
||
`NotificationMessage`s the subscription has prebuilt or cached (c7846, c7850). For those, the design uses the
|
||
mechanism that passed the provenance spike (c7851, 66 assertions) and the delivery-history spike (c7852,
|
||
53 assertions):
|
||
|
||
1. **Provenance.** Ordinary-tag data items are created through a custom sampled item. Its per-value `Publish`
|
||
stamps each newly created `MonitoredItemNotification` with an immutable `(NodeId, AttributeId, Category)`. The
|
||
stamp survives handle modification, item deletion and reuse.
|
||
2. **Delivery history.** `OtOpcUaSdkServer` overrides `PublishAsync` and `RepublishAsync`, calls base first, and
|
||
records **one first-delivery choice per cached message object**. The association is weak and keyed by object;
|
||
cached SDK objects are never mutated.
|
||
- If the node is Active at first delivery, the original message is the choice.
|
||
- If the node is Standby, a detached clone is the choice, with every `OrdinaryTag` notification replaced by
|
||
`BadNoCommunication`/null.
|
||
- A Republish returns the recorded choice. First delivery *through* Republish is decided the same way.
|
||
- A short lock orders the choice against the role flip. No lock spans an await.
|
||
3. **Out of scope of the rewrite**, by D4: messages already in flight before the demotion step, and Republish of
|
||
messages first delivered while Active. Unknown-origin notifications are not rewritten; there is no implicit
|
||
policy (c7853).
|
||
|
||
### 4.7 Transition sequencing
|
||
|
||
One actor, `OpcUaPublishActor`, owns the verdict, the ServiceLevel publish and a new `IStandbyProjection` sink
|
||
(in `Commons.OpcUa`, bound late like `IServiceLevelPublisher`). Each transition runs as one serialized handler, in
|
||
this order.
|
||
|
||
**Promotion (Standby → Active)**
|
||
|
||
1. Open the read projection.
|
||
2. For each live ordinary-tag item, queue the current stored value, ignoring filters. The precedent is the queue
|
||
pattern at `OtOpcUaNodeManager.cs:7303`.
|
||
3. Switch the delivery-history choice to Active.
|
||
4. Un-suppress alarm delivery.
|
||
5. Run the promotion refresh (§4.5).
|
||
6. Publish the Active ServiceLevel.
|
||
|
||
**Demotion (Active → Standby)**
|
||
|
||
1. Publish the Standby ServiceLevel.
|
||
2. Switch the delivery-history choice to Standby. This is the D4 boundary.
|
||
3. Suppress alarm delivery.
|
||
4. Close the read projection.
|
||
5. Queue `BadNoCommunication` to each live ordinary-tag item.
|
||
|
||
Invariant: **an Active-band ServiceLevel is never visible while the projection is closed.** If the ServiceLevel
|
||
publish fails (#719 retry path), a promotion stops before step 6 and retries. A demotion continues anyway: failing
|
||
safe means degrading the data.
|
||
|
||
### 4.8 Standalone (`None`) and `Unset`
|
||
|
||
`None` never projects, never suppresses and never refreshes. It advertises `RedundancySupport=None` with no
|
||
`ServerUriArray`, and uses today's ServiceLevel. `Unset` is byte-for-byte today's server, including the documented
|
||
unmet A4/A5b gates.
|
||
|
||
## 5. ScadaBridge impact (cross-repo, blocking for any Warm flip)
|
||
|
||
ScadaBridge consumes this server as an OPC UA client, through `RealOpcUaClient` and `DataConnectionActor`.
|
||
|
||
- **Failover is connection-driven, not ServiceLevel-driven.** ScadaBridge swaps primary to backup only after
|
||
`FailoverRetryCount` consecutive *unstable disconnects*
|
||
(`../ScadaBridge/src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Actors/DataConnectionActor.cs:655-690`;
|
||
`RealOpcUaClient.cs` sits in that project's `Adapters/`).
|
||
`BadNoCommunication` is not a connection-level status (`:1974-1983`), so it maps to plain Bad quality, and since
|
||
ScadaBridge#112 a Bad-with-null update keeps the last-known value. Nothing in ScadaBridge reads `ServiceLevel`,
|
||
`RedundancySupport` or `ServerUriArray`.
|
||
- **Consequence.** A ScadaBridge connection that lands on the Standby will sit on Bad quality indefinitely on a
|
||
healthy session, and never fail over. Today the same connection gets Good data at 240. Warm is therefore an
|
||
**outage for ScadaBridge** unless ScadaBridge becomes ServiceLevel-aware: monitor `i=2267` and treat a Degraded
|
||
band (< 200) sustained for N s, while the other endpoint reports a higher level, as a failover trigger. That
|
||
change must ship and be deployed first. The plan files it as a ScadaBridge issue (`cross-repo`, blocking).
|
||
- **Alarms are compatible.** ScadaBridge already handles a RefreshStart/RefreshEnd replay as a snapshot
|
||
(`RealOpcUaClient.cs:72`) and triggers its own ConditionRefresh on (re)subscribe (`:1179-1193`). Under D5 that
|
||
refresh returns retained conditions on the Standby too. The promotion refresh arrives as an unsolicited
|
||
Start/End pair on existing items; this needs a ScadaBridge-side test.
|
||
- **Status mapping is compatible.** ScadaBridge#117 maps by severity bits, so `BadNoCommunication` is Bad.
|
||
|
||
## 6. Configuration surface
|
||
|
||
| Key | Default | Notes |
|
||
|---|---|---|
|
||
| `OpcUa:Redundancy:Mode` | `Unset` | `Unset` / `None` / `Warm`. `Hot` and unknown values fail host start. Startup-static. Flip **both** pair nodes in one window, after both run a revision-capable build (§4.2). |
|
||
| `OpcUa:PeerApplicationUris` | `[]` | Existing key, now also the `ServerUriArray` peer source. Required (≥ 1) for `Warm`, must be empty for `None`. |
|
||
| `OpcUa:ApplicationUri` | `urn:OtOpcUa` | Must be unique within the pair under `Warm` (validated against the effective config). |
|
||
|
||
There are no ConfigDb schema changes. `ServerCluster.RedundancyMode` is only cross-checked (§3).
|
||
|
||
## 7. Observability
|
||
|
||
- `otopcua.redundancy.warm_role`: gauge. 1 = Active, 0 = Standby, −1 = not Warm.
|
||
- `otopcua.redundancy.warm_transition{direction,reason}`: counter. Reasons: `membership`, `snapshot`,
|
||
`endpoint`, `boot`.
|
||
- `otopcua.redundancy.snapshot_rejected{reason=older_revision|unrevisioned}`: counter.
|
||
- `otopcua.redundancy.mode_mismatch`: counter (§3).
|
||
- `otopcua.opcua.standby.projected_notifications`: counter. Counts D4 rewrites at Publish/Republish.
|
||
- `otopcua.opcua.standby.suppressed_alarm_events`: counter.
|
||
- Logs:
|
||
- Information per transition, naming the revision and the verdict inputs.
|
||
- Warning when membership and snapshot disagree for more than 20 s.
|
||
- A boot banner line with mode, effective self URI and peers.
|
||
- `otopcua-cli redundancy` already reads `i=3709`, `i=11314` and `i=2267`.
|
||
|
||
## 8. Explicitly out of scope
|
||
|
||
- Hot (and Transparent) redundancy.
|
||
- Dynamic peer membership. Peers are static config.
|
||
- Changing the election (oldest Up driver member), `auto-down`, or the write / native-ack / HistoryUpdate /
|
||
alarm-drain / historization gates.
|
||
- Stopping acquisition on the Standby.
|
||
- TransferSubscriptions across the pair. Non-transparent means the client re-creates its subscriptions.
|
||
- CTT (G8) and production-client cutover (G9). Hermetic and live-rig passes are not acceptance.
|
||
- Durable subscription restore.
|
||
- Sequence-number wrap.
|
||
- Encoded-byte fidelity of cloned payloads beyond the plan's bounded matrix (c7890).
|
||
|
||
## 9. Open questions for the owner (short)
|
||
|
||
1. **Standby writes.** Keep today's optimistic Good + revert (D7), or refuse synchronously with `BadInvalidState`
|
||
under Warm, as HistoryUpdate and native ack already do? *Recommend synchronous refusal under Warm only.*
|
||
2. **Crash-failover gap.** A SIGKILLed Primary stays an unreachable member until auto-down, ~25–30 s. Under (2)/(3)
|
||
the survivor stays Standby for that whole window, with no Good data anywhere, where today the Secondary keeps
|
||
serving. Should the survivor be allowed to promote when the Primary is *unreachable* (the #672 pattern, default
|
||
on), accepting dual-Active during a real partition? *Recommend yes, behind
|
||
`OpcUa:Redundancy:PromoteWhilePrimaryUnreachable`.*
|
||
3. **Standby status code.** `BadNoCommunication` is spike-proven and is plain Bad in ScadaBridge, but it is the
|
||
same code as real device comms loss; only ServiceLevel tells them apart. Accept it, or use `BadOutOfService`?
|
||
4. **Scripted Part 9 methods on the Standby.** They are accepted (D7) but their event is suppressed (D3), so the
|
||
caller sees Good and no event until promotion or refresh. Accept, or refuse with `BadInvalidState` under Warm?
|
||
5. **ConfigDb `Hot`.** Narrow the CHECK to `None/Warm` with a migration, or leave it and rely on the §3 mismatch
|
||
Error?
|
||
6. **Bands.** Are Standby 90/50 and boot 1 acceptable (§4.3)?
|
||
|
||
## 10. What must be re-proven on SDK 2.0.1
|
||
|
||
The spikes ran on **1.5.378.106**. The repo now pins **2.0.1** (`Directory.Packages.props:129-135`). The 2.0.1 XML
|
||
docs confirm that these members still exist:
|
||
|
||
- `StandardServer.CreateMainNodeManagerFactory`
|
||
- `ConfigurationNodeManager.AddBehaviourToPredefinedNodeAsync`, now **async**
|
||
- `NonTransparentRedundancyState.ServerUriArray`, now in `Opc.Ua.Core.Types`
|
||
- `StandardServer.PublishAsync` / `RepublishAsync`, whose signatures now carry `RequestLifetime`
|
||
- `CreateSubscriptionManager`
|
||
- `BaseVariableState.OnSimpleReadValue`, plus new `OnSimpleReadValueAsync` / `OnReadValueAsync`
|
||
- `ReadValueAttribute`
|
||
- `IServerInternal.ConditionRefresh2`
|
||
- a new `MonitoredItemFactory` / `MonitoredItemCreateDecision` creation hook and an
|
||
`IMonitoredItemTransferCoordinator`
|
||
|
||
Existence is not behaviour. Plan T0 re-proves, on 2.0.1 over the wire:
|
||
|
||
- (a) the metadata graph, including the passive-`i=11314` resolution;
|
||
- (b) that **every** value read path reaches the per-tag projection: Read, initial sample, change fan-out,
|
||
ResendData, size-1 queue and AggregateFilter. In particular, the new async read callbacks must not bypass a sync
|
||
`OnSimpleReadValue`; if they do, the hook moves to a `ReadValueAttribute` override on `EquipmentVariableState`;
|
||
- (c) provenance through the 2.0.1 creation hook, which replaces the 1.5 manager-subclass route, including
|
||
transfer/restore;
|
||
- (d) the Publish/Republish choice with the new signatures;
|
||
- (e) suppression and promotion refresh through the product's #854/#855 per-item paths, which did not exist when
|
||
the 1.5 event spike ran.
|