FOCAS PR 2 � IReadable + IWritable + real FwlibFocasClient P/Invoke #125

Merged
dohertj2 merged 1 commits from focas-pr2-read-write-real-client into v2 2026-04-19 19:57:33 -04:00
Owner

Closes task #193 early (strangesast/fwlib license signed). Real FwlibFocasClient wraps Fwlib32.dll via P/Invoke � cnc_allclibhndl3/freelibhndl/pmc_rdpmcrng/pmc_wrpmcrng/cnc_rdparam/cnc_wrparam/cnc_rdmacro/cnc_wrmacro/cnc_statinfo. Driver now defaults to FwlibFocasClientFactory (real wire); UnimplementedFocasClientFactory kept as opt-in. PMC Bit writes deferred to task #181 (shared RMW gap). 41 new tests, 106/106 passing. Deployment drops Fwlib32.dll beside the server � DLL not shipped (licensing). Merges to v2.

Closes task #193 early (strangesast/fwlib license signed). Real FwlibFocasClient wraps Fwlib32.dll via P/Invoke � cnc_allclibhndl3/freelibhndl/pmc_rdpmcrng/pmc_wrpmcrng/cnc_rdparam/cnc_wrparam/cnc_rdmacro/cnc_wrmacro/cnc_statinfo. Driver now defaults to FwlibFocasClientFactory (real wire); UnimplementedFocasClientFactory kept as opt-in. PMC Bit writes deferred to task #181 (shared RMW gap). 41 new tests, 106/106 passing. Deployment drops Fwlib32.dll beside the server � DLL not shipped (licensing). Merges to v2.
dohertj2 added 1 commit 2026-04-19 19:57:30 -04:00
FOCAS PR 2 — IReadable + IWritable + real FwlibFocasClient P/Invoke. Closes task #193 early now that strangesast/fwlib provides the licensed DLL references. Skips shipping with the Unimplemented stub as the default — FwlibFocasClientFactory is now the production default, UnimplementedFocasClientFactory stays as an opt-in for tests/deployments without FWLIB access. FwlibNative — narrow P/Invoke surface for the 7 calls the driver actually makes: cnc_allclibhndl3 (open Ethernet handle), cnc_freelibhndl (close), pmc_rdpmcrng + pmc_wrpmcrng (PMC range I/O), cnc_rdparam + cnc_wrparam (CNC parameters), cnc_rdmacro + cnc_wrmacro (macro variables), cnc_statinfo (probe). DllImport targets Fwlib32.dll; deployment places it next to the executable or on PATH. IODBPMC/IODBPSD/ODBM/ODBST marshaled with LayoutKind.Sequential + Pack=1 + fixed byte-array unions (avoids LayoutKind.Explicit complexity; managed-side BitConverter extracts typed values from the byte buffer). Internal helpers FocasPmcAddrType.FromLetter (G=0/F=1/Y=2/X=3/A=4/R=5/T=6/K=7/C=8/D=9/E=10 per Fanuc FOCAS/2 spec) + FocasPmcDataType.FromFocasDataType (Byte=0 / Word=1 / Long=2 / Float=4 / Double=5) exposed for testing without the DLL loaded. FwlibFocasClient is the concrete IFocasClient backed by P/Invoke. Construction is licence-safe — .NET P/Invoke is lazy so instantiating the class does NOT load Fwlib32.dll; DLL loads on first wire call (Connect/Read/Write/Probe). When missing, calls throw DllNotFoundException which the driver surfaces as BadCommunicationError via the normal exception path. Session-scoped handle from cnc_allclibhndl3; Dispose calls cnc_freelibhndl. Dispatch on FocasAreaKind — Pmc reads use pmc_rdpmcrng with the right ADR_* + data-type codes + parses the union via BinaryPrimitives LittleEndian, Parameter reads use cnc_rdparam + IODBPSD, Macro reads use cnc_rdmacro + compute scaled double as McrVal / 10^DecVal. Write paths mirror reads. PMC Bit writes throw NotSupportedException pointing at task #181 (read-modify-write gap — same as Modbus / AbCip / AbLegacy / TwinCAT). Macro writes accept int + pass decimal-point count 0 (decimal precision writes are a future enhancement). Probe calls cnc_statinfo with ODBST result. Driver wiring — FocasDriver now IDriver + IReadable + IWritable. Per-device connection caching via EnsureConnectedAsync + DeviceState.Client. ReadAsync/WriteAsync dispatch through the injected IFocasClient — ordered snapshots preserve per-tag status, OperationCanceledException rethrows, FormatException/InvalidCastException → BadTypeMismatch, OverflowException → BadOutOfRange, NotSupportedException → BadNotSupported, anything else → BadCommunicationError + Degraded health. Connect-failure disposes the half-open client. ShutdownAsync disposes every cached client. Default factory switched — constructor now defaults to FwlibFocasClientFactory (backed by real Fwlib32.dll) rather than UnimplementedFocasClientFactory. UnimplementedFocasClientFactory stays as an opt-in. 41 new tests — 14 in FocasReadWriteTests (ordered unknown-ref handling, successful PMC/Parameter/Macro reads routing through correct FocasAreaKind, repeat-read reuses connection, FOCAS error mapping, exception paths, batched order across areas, non-writable rejection, successful write logging, status mapping, batch ordering, cancellation, shutdown disposes), 27 in FwlibNativeHelperTests (12 letter-mapping cases + 3 unknown rejections + 6 data-type mapping + 4 encode helpers + Bit-write NotSupported). Total FOCAS unit tests now 106/106 passing (+41 from PR 1's 65); full solution builds 0 errors; Modbus / AbCip / AbLegacy / TwinCAT / other drivers untouched. FOCAS driver is real-wire-capable from day one — deployment drops Fwlib32.dll beside the server + driver talks to live FS 0i/16i/18i/21i/30i/31i/32i controllers. a2c7fda5f5
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
dohertj2 merged commit 5cfb0fc6d0 into v2 2026-04-19 19:57:33 -04:00
dohertj2 referenced this issue from a commit 2026-04-19 21:42:59 -04:00
Admin Equipment editor — IdentificationFields component + edit mode + three missing OPC 40010 fields. Closes the UI-editor slice of task #159 (Phase 6.4 Stream D remaining); the DriverNodeManager wire-in + ACL integration test are split into a new follow-up task #195 because they're blocked on a prerequisite that hasn't shipped — the DriverNodeManager does not currently materialize Equipment nodes at all (NodeScopeResolver has an explicit "A future resolver will..." TODO in its decomposition docstring). Shipping the IdentificationFolderBuilder call before the parent walker exists would wire a call that no code path hits, so the wire-in is deferred until the Equipment node walker lands first. New IdentificationFields.razor reusable component renders the 9-field decision #139 grid in a Bootstrap 3-column layout — Manufacturer, Model, SerialNumber, HardwareRevision, SoftwareRevision, YearOfConstruction (InputNumber), AssetLocation, ManufacturerUri (placeholder https://…), DeviceManualUri (placeholder https://…). Takes a required Equipment parameter + 2-way binds every field; no state of its own. Three fields that were missing from the old inline form — AssetLocation, ManufacturerUri, DeviceManualUri — now present, matching IdentificationFolderBuilder.FieldNames exactly. EquipmentTab.razor refactored to consume the component in both create + edit flows. Each table row gains an Edit button next to Remove. StartEdit clones the row into _draft so Cancel doesn't mutate the displayed list row with in-flight edits; on Save, UpdateAsync persists through EquipmentService's existing update path which already handles all 9 Identification fields. SaveAsync branches on _editMode — create still derives EquipmentId from a fresh Uuid via DraftValidator per decision #125, edit keeps the original EquipmentId + EquipmentUuid (immutable once set). FormName renamed equipment-form (was new-equipment) to work for both flows. Admin project builds 0 errors; Admin.Tests 72/72 passing. No new tests shipped — this PR is strictly a Razor-component refactor + two new bound fields + an Edit branch; the existing EquipmentService tests cover both the create + update paths. Task #195 created to track the blocked server-side work: call IdentificationFolderBuilder.Build from DriverNodeManager once the Equipment walker exists, plus an integration test browsing Equipment/Identification as an unauthorized user asserting BadUserAccessDenied per the builder's cross-reference note in docs/v2/acl-design.md §Identification.
Sign in to join this conversation.
No Reviewers
No Label
1 Participants
Notifications
Due Date
No due date set.
Dependencies

No dependencies set.

Reference: dohertj2/lmxopcua#125