AB CIP PR 9-12 � Per-family profile tests + GuardLogix safety-tag support #116

Merged
dohertj2 merged 1 commits from abcip-pr9-12-family-profiles into v2 2026-04-19 17:20:44 -04:00
Owner

Consolidates PRs 9/10/11/12 � ControlLogix / CompactLogix / Micro800 / GuardLogix profile-metadata assertions + integration-surface wiring. Per-family live-wire tests deferred to the ab_server-CI follow-up. New AbCipTagDefinition.SafetyTag field for GuardLogix � forces ViewOnly in discovery + rejects writes with BadNotWritable. 14 new tests, 161/161 passing. Merges to v2.

Consolidates PRs 9/10/11/12 � ControlLogix / CompactLogix / Micro800 / GuardLogix profile-metadata assertions + integration-surface wiring. Per-family live-wire tests deferred to the ab_server-CI follow-up. New `AbCipTagDefinition.SafetyTag` field for GuardLogix � forces ViewOnly in discovery + rejects writes with BadNotWritable. 14 new tests, 161/161 passing. Merges to v2.
dohertj2 added 1 commit 2026-04-19 17:20:41 -04:00
AB CIP PR 9-12 — Per-PLC-family profile tests + GuardLogix safety-tag support. Consolidates PRs 9/10/11/12 from the plan (ControlLogix / CompactLogix / Micro800 / GuardLogix integration suites) into a single PR because the per-family work that actually ships without a live ab_server binary is profile-metadata assertion + unit-level driver-option binding. Per-family integration tests that require a running simulator are deferred to the ab_server-CI follow-up already tracked from PR 3 (download prebuilt Windows binary as GitHub release asset). ControlLogix — baseline profile asserted (controllogix attribute, 4002 LFO ConnectionSize, 1,0 default path, request-packing + connected-messaging, 4000B max fragment). CompactLogix — narrower 504 ConnectionSize for 5069-L3x safety, 500B max fragment, lib attribute compactlogix which libplctag maps to the ControlLogix family internally but via our profile chain we surface it as a distinct knob so future quirk handling (5069 narrow-window regression cases) hangs off the compactlogix attribute. Micro800 — empty CIP path for no-backplane routing, 488B ConnectionSize, 484B fragment cap, request packing + connected messaging both disabled (most models reject Forward_Open), micro800 lib attribute. Test asserts the driver correctly parses an ab://192.168.1.20/ host address with empty path + forwards the empty path through AbCipTagCreateParams so libplctag sees the unconnected-only configuration. GuardLogix — wire protocol identical to ControlLogix (safety partition is a per-tag concern, not a wire-layer distinction) so profile defaults match ControlLogix. New AbCipTagDefinition.SafetyTag field — when true, the driver forces SecurityClassification.ViewOnly in discovery regardless of the Writable flag, and IWritable rejects the write upfront with BadNotWritable. Matches the Rockwell safety-partition isolation model where non-safety-task writes to safety tags would be rejected by the PLC anyway — surfacing the intent at the driver surface prevents wasted wire round-trips + gives Admin UI users a correct ViewOnly rendering. 14 new unit tests in AbCipPlcFamilyTests covering — ControlLogix profile defaults + correct profile selection at Initialize, CompactLogix narrower-than-ControlLogix ConnectionSize + fragment cap, Micro800 empty path parses + SupportsConnectedMessaging=false + SupportsRequestPacking=false + read forwards empty path + micro800 attribute through to libplctag, GuardLogix wire-protocol parity with ControlLogix, GuardLogix safety tag surfaces as ViewOnly in discovery even when Writable=true, GuardLogix safety-tag write rejected with BadNotWritable even when Writable=true, ForFamily theory (4 families → correct libplctag attribute). Total AbCip unit tests now 161/161 passing (+14 from PR 8's 147). Modbus + other drivers untouched; full solution builds 0 errors. PR 13 (IAlarmSource via tag-projected ALMA/ALMD blocks) remains deferred per the plan — feature-flagged pattern not needed before go-live. 60b8d6f2d0
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
dohertj2 merged commit 70f5f2cad1 into v2 2026-04-19 17:20:44 -04:00
dohertj2 referenced this issue from a commit 2026-04-20 02:30:04 -04:00
Draft ADR-001 — Equipment node walker: how driver tags bind to the UNS address space. Frames the decision blocking task #195 (IdentificationFolderBuilder wire-in): the Equipment-namespace browse tree requires a Config-DB-driven walker that traverses UNS → Equipment → Tag + hangs Identification sub-folders + identifier properties, and the open question is how driver-discovered tags bind to the UNS Equipment nodes the walker materializes. Context section documents what already exists (IdentificationFolderBuilder unused; NodeScopeResolver at Phase-1 cluster-only stub; Equipment + UnsArea + UnsLine + Tag tables with decisions #110 #116 #117 #120 #121 already landed as the data-model contract) vs what's missing (the walker itself + the ITagDiscovery/Config-DB composition strategy). Four options laid out with trade-offs: Option A Config-primary (Tag rows are the sole source of truth; ITagDiscovery becomes enrichment; BadNotFound placeholder when driver can't address a declared tag); Option B Discovery-primary (driver output is authoritative; Config-DB Equipment rows select subsets); Option C Parallel namespaces (driver-native ns + UNS overlay ns cross-referencing via OPC UA Organizes); Option D Config-primary-with-discovery-assist (same as A at runtime, plus an Admin UI offline discovery panel that lets operators one-click-import discovered tags into the draft). Recommendation: Option A now, defer Option D to v2.1. Reasons: matches decision #110's framing straight-through, identical composition across every Equipment-kind driver, Phase 6.4 Admin UI already authors Tag rows, BadNotFound is a legible failure mode, and nothing in A blocks adding D later without changing the walker contract. If the ADR is accepted, spawns two tasks: Task A builds EquipmentNodeWalker in Core.OpcUa (cluster → namespace → area → line → equipment → tag traversal, IdentificationFolderBuilder per Equipment, 5 identifier properties, BadNotFound placeholders, integration tests); Task B extends NodeScopeResolver to join against Config DB + populate full NodeScope path (unblocks per-Equipment/per-UnsLine ACL granularity + closes task #195 with the ACL integration test from the builder's docstring cross-reference). Consequences-if-we-don't-decide section captures the status quo: Identification metadata ships in DB + Admin UI but never reaches the OPC UA endpoint, external consumers can't resolve equipment via OPC UA properties as decision #121 promises, and NodeScopeResolver stays cluster-level so finer ACL grants are effectively cluster-wide at dispatch (Phase 6.2 rollout limitation, not correctness bug). Draft status — seeking decision before spawning the two implementation tasks. If accepted I'll add the tasks + start on Task A.