using Microsoft.EntityFrameworkCore.Migrations;
|
||||||
|
|
||||||
|
#nullable disable
|
||||||
|
|
||||||
|
namespace ZB.MOM.WW.OtOpcUa.Configuration.Migrations
|
||||||
|
{
|
||||||
|
/// <summary>
|
||||||
|
/// Phase 7 follow-up (task #241) — extends <c>dbo.sp_ComputeGenerationDiff</c> to emit
|
||||||
|
/// Script / VirtualTag / ScriptedAlarm rows alongside the existing Namespace /
|
||||||
|
/// DriverInstance / Equipment / Tag / NodeAcl output. Admin DiffViewer now shows
|
||||||
|
/// Phase 7 changes between generations.
|
||||||
|
/// </summary>
|
||||||
|
/// <remarks>
|
||||||
|
/// Logical ids: ScriptId, VirtualTagId, ScriptedAlarmId — stable across generations
|
||||||
|
/// so a Script whose source changes surfaces as Modified (CHECKSUM picks up the
|
||||||
|
/// SourceHash delta) while a renamed script surfaces as Modified on Name alone.
|
||||||
|
/// ScriptedAlarmState is deliberately excluded — it's not generation-scoped, so
|
||||||
|
/// diffing it between generations is meaningless.
|
||||||
|
/// </remarks>
|
||||||
|
/// <inheritdoc />
|
||||||
|
public partial class ExtendComputeGenerationDiffWithPhase7 : Migration
|
||||||
|
{
|
||||||
|
/// <inheritdoc />
|
||||||
|
protected override void Up(MigrationBuilder migrationBuilder)
|
||||||
|
{
|
||||||
|
migrationBuilder.Sql(Procs.ComputeGenerationDiffV3);
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <inheritdoc />
|
||||||
|
protected override void Down(MigrationBuilder migrationBuilder)
|
||||||
|
{
|
||||||
|
migrationBuilder.Sql(Procs.ComputeGenerationDiffV2);
|
||||||
|
}
|
||||||
|
|
||||||
|
private static class Procs
|
||||||
|
{
|
||||||
|
/// <summary>V3 — adds Script / VirtualTag / ScriptedAlarm sections.</summary>
|
||||||
|
public const string ComputeGenerationDiffV3 = @"
|
||||||
|
CREATE OR ALTER PROCEDURE dbo.sp_ComputeGenerationDiff
|
||||||
|
@FromGenerationId bigint,
|
||||||
|
@ToGenerationId bigint
|
||||||
|
AS
|
||||||
|
BEGIN
|
||||||
|
SET NOCOUNT ON;
|
||||||
|
|
||||||
|
CREATE TABLE #diff (TableName nvarchar(32), LogicalId nvarchar(128), ChangeKind nvarchar(16));
|
||||||
|
|
||||||
|
WITH f AS (SELECT NamespaceId AS LogicalId, CHECKSUM(NamespaceUri, Kind, Enabled, Notes) AS Sig FROM dbo.Namespace WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT NamespaceId AS LogicalId, CHECKSUM(NamespaceUri, Kind, Enabled, Notes) AS Sig FROM dbo.Namespace WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'Namespace', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
WITH f AS (SELECT DriverInstanceId AS LogicalId, CHECKSUM(ClusterId, NamespaceId, Name, DriverType, Enabled, CONVERT(varchar(max), DriverConfig)) AS Sig FROM dbo.DriverInstance WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT DriverInstanceId AS LogicalId, CHECKSUM(ClusterId, NamespaceId, Name, DriverType, Enabled, CONVERT(varchar(max), DriverConfig)) AS Sig FROM dbo.DriverInstance WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'DriverInstance', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
WITH f AS (SELECT EquipmentId AS LogicalId, CHECKSUM(EquipmentUuid, DriverInstanceId, UnsLineId, Name, MachineCode, ZTag, SAPID, EquipmentClassRef, Manufacturer, Model, SerialNumber) AS Sig FROM dbo.Equipment WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT EquipmentId AS LogicalId, CHECKSUM(EquipmentUuid, DriverInstanceId, UnsLineId, Name, MachineCode, ZTag, SAPID, EquipmentClassRef, Manufacturer, Model, SerialNumber) AS Sig FROM dbo.Equipment WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'Equipment', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
WITH f AS (SELECT TagId AS LogicalId, CHECKSUM(DriverInstanceId, DeviceId, EquipmentId, PollGroupId, FolderPath, Name, DataType, AccessLevel, WriteIdempotent, CONVERT(varchar(max), TagConfig)) AS Sig FROM dbo.Tag WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT TagId AS LogicalId, CHECKSUM(DriverInstanceId, DeviceId, EquipmentId, PollGroupId, FolderPath, Name, DataType, AccessLevel, WriteIdempotent, CONVERT(varchar(max), TagConfig)) AS Sig FROM dbo.Tag WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'Tag', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
WITH f AS (
|
||||||
|
SELECT CONVERT(nvarchar(128), LdapGroup + '|' + CONVERT(nvarchar(16), ScopeKind) + '|' + ISNULL(ScopeId, '(cluster)')) AS LogicalId,
|
||||||
|
CHECKSUM(ClusterId, PermissionFlags, Notes) AS Sig
|
||||||
|
FROM dbo.NodeAcl WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (
|
||||||
|
SELECT CONVERT(nvarchar(128), LdapGroup + '|' + CONVERT(nvarchar(16), ScopeKind) + '|' + ISNULL(ScopeId, '(cluster)')) AS LogicalId,
|
||||||
|
CHECKSUM(ClusterId, PermissionFlags, Notes) AS Sig
|
||||||
|
FROM dbo.NodeAcl WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'NodeAcl', COALESCE(f.LogicalId, t.LogicalId),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
-- Phase 7 — Script section. CHECKSUM picks up source changes via SourceHash + rename
|
||||||
|
-- via Name; Language future-proofs for non-C# engines. Same Name + same Source =
|
||||||
|
-- Unchanged (identical hash).
|
||||||
|
WITH f AS (SELECT ScriptId AS LogicalId, CHECKSUM(Name, SourceHash, Language) AS Sig FROM dbo.Script WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT ScriptId AS LogicalId, CHECKSUM(Name, SourceHash, Language) AS Sig FROM dbo.Script WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'Script', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
-- Phase 7 — VirtualTag section.
|
||||||
|
WITH f AS (SELECT VirtualTagId AS LogicalId, CHECKSUM(EquipmentId, Name, DataType, ScriptId, ChangeTriggered, TimerIntervalMs, Historize, Enabled) AS Sig FROM dbo.VirtualTag WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT VirtualTagId AS LogicalId, CHECKSUM(EquipmentId, Name, DataType, ScriptId, ChangeTriggered, TimerIntervalMs, Historize, Enabled) AS Sig FROM dbo.VirtualTag WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'VirtualTag', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
-- Phase 7 — ScriptedAlarm section. ScriptedAlarmState (operator ack trail) is
|
||||||
|
-- logical-id keyed outside the generation scope + intentionally excluded here —
|
||||||
|
-- diffing ack state between generations is semantically meaningless.
|
||||||
|
WITH f AS (SELECT ScriptedAlarmId AS LogicalId, CHECKSUM(EquipmentId, Name, AlarmType, Severity, MessageTemplate, PredicateScriptId, HistorizeToAveva, Retain, Enabled) AS Sig FROM dbo.ScriptedAlarm WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT ScriptedAlarmId AS LogicalId, CHECKSUM(EquipmentId, Name, AlarmType, Severity, MessageTemplate, PredicateScriptId, HistorizeToAveva, Retain, Enabled) AS Sig FROM dbo.ScriptedAlarm WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'ScriptedAlarm', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
SELECT TableName, LogicalId, ChangeKind FROM #diff;
|
||||||
|
DROP TABLE #diff;
|
||||||
|
END
|
||||||
|
";
|
||||||
|
|
||||||
|
/// <summary>V2 — restores the pre-Phase-7 proc on Down().</summary>
|
||||||
|
public const string ComputeGenerationDiffV2 = @"
|
||||||
|
CREATE OR ALTER PROCEDURE dbo.sp_ComputeGenerationDiff
|
||||||
|
@FromGenerationId bigint,
|
||||||
|
@ToGenerationId bigint
|
||||||
|
AS
|
||||||
|
BEGIN
|
||||||
|
SET NOCOUNT ON;
|
||||||
|
|
||||||
|
CREATE TABLE #diff (TableName nvarchar(32), LogicalId nvarchar(128), ChangeKind nvarchar(16));
|
||||||
|
|
||||||
|
WITH f AS (SELECT NamespaceId AS LogicalId, CHECKSUM(NamespaceUri, Kind, Enabled, Notes) AS Sig FROM dbo.Namespace WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT NamespaceId AS LogicalId, CHECKSUM(NamespaceUri, Kind, Enabled, Notes) AS Sig FROM dbo.Namespace WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'Namespace', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
WITH f AS (SELECT DriverInstanceId AS LogicalId, CHECKSUM(ClusterId, NamespaceId, Name, DriverType, Enabled, CONVERT(varchar(max), DriverConfig)) AS Sig FROM dbo.DriverInstance WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT DriverInstanceId AS LogicalId, CHECKSUM(ClusterId, NamespaceId, Name, DriverType, Enabled, CONVERT(varchar(max), DriverConfig)) AS Sig FROM dbo.DriverInstance WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'DriverInstance', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
WITH f AS (SELECT EquipmentId AS LogicalId, CHECKSUM(EquipmentUuid, DriverInstanceId, UnsLineId, Name, MachineCode, ZTag, SAPID, EquipmentClassRef, Manufacturer, Model, SerialNumber) AS Sig FROM dbo.Equipment WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT EquipmentId AS LogicalId, CHECKSUM(EquipmentUuid, DriverInstanceId, UnsLineId, Name, MachineCode, ZTag, SAPID, EquipmentClassRef, Manufacturer, Model, SerialNumber) AS Sig FROM dbo.Equipment WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'Equipment', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
WITH f AS (SELECT TagId AS LogicalId, CHECKSUM(DriverInstanceId, DeviceId, EquipmentId, PollGroupId, FolderPath, Name, DataType, AccessLevel, WriteIdempotent, CONVERT(varchar(max), TagConfig)) AS Sig FROM dbo.Tag WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (SELECT TagId AS LogicalId, CHECKSUM(DriverInstanceId, DeviceId, EquipmentId, PollGroupId, FolderPath, Name, DataType, AccessLevel, WriteIdempotent, CONVERT(varchar(max), TagConfig)) AS Sig FROM dbo.Tag WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'Tag', CONVERT(nvarchar(128), COALESCE(f.LogicalId, t.LogicalId)),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
WITH f AS (
|
||||||
|
SELECT CONVERT(nvarchar(128), LdapGroup + '|' + CONVERT(nvarchar(16), ScopeKind) + '|' + ISNULL(ScopeId, '(cluster)')) AS LogicalId,
|
||||||
|
CHECKSUM(ClusterId, PermissionFlags, Notes) AS Sig
|
||||||
|
FROM dbo.NodeAcl WHERE GenerationId = @FromGenerationId),
|
||||||
|
t AS (
|
||||||
|
SELECT CONVERT(nvarchar(128), LdapGroup + '|' + CONVERT(nvarchar(16), ScopeKind) + '|' + ISNULL(ScopeId, '(cluster)')) AS LogicalId,
|
||||||
|
CHECKSUM(ClusterId, PermissionFlags, Notes) AS Sig
|
||||||
|
FROM dbo.NodeAcl WHERE GenerationId = @ToGenerationId)
|
||||||
|
INSERT #diff
|
||||||
|
SELECT 'NodeAcl', COALESCE(f.LogicalId, t.LogicalId),
|
||||||
|
CASE WHEN f.LogicalId IS NULL THEN 'Added'
|
||||||
|
WHEN t.LogicalId IS NULL THEN 'Removed'
|
||||||
|
WHEN f.Sig <> t.Sig THEN 'Modified'
|
||||||
|
ELSE 'Unchanged' END
|
||||||
|
FROM f FULL OUTER JOIN t ON f.LogicalId = t.LogicalId
|
||||||
|
WHERE f.LogicalId IS NULL OR t.LogicalId IS NULL OR f.Sig <> t.Sig;
|
||||||
|
|
||||||
|
SELECT TableName, LogicalId, ChangeKind FROM #diff;
|
||||||
|
DROP TABLE #diff;
|
||||||
|
END
|
||||||
|
";
|
||||||
|
}
|
||||||
|
}
|
||||||
|
}
|
||||||
@@ -30,6 +30,14 @@ public sealed class OpcUaApplicationHost : IAsyncDisposable
|
|||||||
private readonly Func<string, ZB.MOM.WW.OtOpcUa.Core.Abstractions.DriverTier>? _tierLookup;
|
private readonly Func<string, ZB.MOM.WW.OtOpcUa.Core.Abstractions.DriverTier>? _tierLookup;
|
||||||
private readonly Func<string, string?>? _resilienceConfigLookup;
|
private readonly Func<string, string?>? _resilienceConfigLookup;
|
||||||
private readonly Func<string, ZB.MOM.WW.OtOpcUa.Core.OpcUa.EquipmentNamespaceContent?>? _equipmentContentLookup;
|
private readonly Func<string, ZB.MOM.WW.OtOpcUa.Core.OpcUa.EquipmentNamespaceContent?>? _equipmentContentLookup;
|
||||||
|
|
||||||
|
// Phase 7 Stream G follow-up (task #239). When composed with the VirtualTagEngine +
|
||||||
|
// ScriptedAlarmEngine sources these route node reads to the engines instead of the
|
||||||
|
// driver. Null = Phase 7 engines not enabled for this deployment (identical to pre-
|
||||||
|
// Phase-7 behaviour).
|
||||||
|
private readonly ZB.MOM.WW.OtOpcUa.Core.Abstractions.IReadable? _virtualReadable;
|
||||||
|
private readonly ZB.MOM.WW.OtOpcUa.Core.Abstractions.IReadable? _scriptedAlarmReadable;
|
||||||
|
|
||||||
private readonly ILoggerFactory _loggerFactory;
|
private readonly ILoggerFactory _loggerFactory;
|
||||||
private readonly ILogger<OpcUaApplicationHost> _logger;
|
private readonly ILogger<OpcUaApplicationHost> _logger;
|
||||||
private ApplicationInstance? _application;
|
private ApplicationInstance? _application;
|
||||||
@@ -45,7 +53,9 @@ public sealed class OpcUaApplicationHost : IAsyncDisposable
|
|||||||
StaleConfigFlag? staleConfigFlag = null,
|
StaleConfigFlag? staleConfigFlag = null,
|
||||||
Func<string, ZB.MOM.WW.OtOpcUa.Core.Abstractions.DriverTier>? tierLookup = null,
|
Func<string, ZB.MOM.WW.OtOpcUa.Core.Abstractions.DriverTier>? tierLookup = null,
|
||||||
Func<string, string?>? resilienceConfigLookup = null,
|
Func<string, string?>? resilienceConfigLookup = null,
|
||||||
Func<string, ZB.MOM.WW.OtOpcUa.Core.OpcUa.EquipmentNamespaceContent?>? equipmentContentLookup = null)
|
Func<string, ZB.MOM.WW.OtOpcUa.Core.OpcUa.EquipmentNamespaceContent?>? equipmentContentLookup = null,
|
||||||
|
ZB.MOM.WW.OtOpcUa.Core.Abstractions.IReadable? virtualReadable = null,
|
||||||
|
ZB.MOM.WW.OtOpcUa.Core.Abstractions.IReadable? scriptedAlarmReadable = null)
|
||||||
{
|
{
|
||||||
_options = options;
|
_options = options;
|
||||||
_driverHost = driverHost;
|
_driverHost = driverHost;
|
||||||
@@ -57,6 +67,8 @@ public sealed class OpcUaApplicationHost : IAsyncDisposable
|
|||||||
_tierLookup = tierLookup;
|
_tierLookup = tierLookup;
|
||||||
_resilienceConfigLookup = resilienceConfigLookup;
|
_resilienceConfigLookup = resilienceConfigLookup;
|
||||||
_equipmentContentLookup = equipmentContentLookup;
|
_equipmentContentLookup = equipmentContentLookup;
|
||||||
|
_virtualReadable = virtualReadable;
|
||||||
|
_scriptedAlarmReadable = scriptedAlarmReadable;
|
||||||
_loggerFactory = loggerFactory;
|
_loggerFactory = loggerFactory;
|
||||||
_logger = logger;
|
_logger = logger;
|
||||||
}
|
}
|
||||||
@@ -85,7 +97,8 @@ public sealed class OpcUaApplicationHost : IAsyncDisposable
|
|||||||
|
|
||||||
_server = new OtOpcUaServer(_driverHost, _authenticator, _pipelineBuilder, _loggerFactory,
|
_server = new OtOpcUaServer(_driverHost, _authenticator, _pipelineBuilder, _loggerFactory,
|
||||||
authzGate: _authzGate, scopeResolver: _scopeResolver,
|
authzGate: _authzGate, scopeResolver: _scopeResolver,
|
||||||
tierLookup: _tierLookup, resilienceConfigLookup: _resilienceConfigLookup);
|
tierLookup: _tierLookup, resilienceConfigLookup: _resilienceConfigLookup,
|
||||||
|
virtualReadable: _virtualReadable, scriptedAlarmReadable: _scriptedAlarmReadable);
|
||||||
await _application.Start(_server).ConfigureAwait(false);
|
await _application.Start(_server).ConfigureAwait(false);
|
||||||
|
|
||||||
_logger.LogInformation("OPC UA server started — endpoint={Endpoint} driverCount={Count}",
|
_logger.LogInformation("OPC UA server started — endpoint={Endpoint} driverCount={Count}",
|
||||||
|
|||||||
@@ -25,6 +25,15 @@ public sealed class OtOpcUaServer : StandardServer
|
|||||||
private readonly NodeScopeResolver? _scopeResolver;
|
private readonly NodeScopeResolver? _scopeResolver;
|
||||||
private readonly Func<string, DriverTier>? _tierLookup;
|
private readonly Func<string, DriverTier>? _tierLookup;
|
||||||
private readonly Func<string, string?>? _resilienceConfigLookup;
|
private readonly Func<string, string?>? _resilienceConfigLookup;
|
||||||
|
|
||||||
|
// Phase 7 Stream G follow-up wiring (task #239). Shared across every DriverNodeManager
|
||||||
|
// instantiated by this server so virtual-tag reads and scripted-alarm reads from any
|
||||||
|
// driver's address-space subtree route to the same engine. When null (no Phase 7
|
||||||
|
// engines composed for this deployment) DriverNodeManager falls back to driver-only
|
||||||
|
// dispatch — identical to pre-Phase-7 behaviour.
|
||||||
|
private readonly IReadable? _virtualReadable;
|
||||||
|
private readonly IReadable? _scriptedAlarmReadable;
|
||||||
|
|
||||||
private readonly ILoggerFactory _loggerFactory;
|
private readonly ILoggerFactory _loggerFactory;
|
||||||
private readonly List<DriverNodeManager> _driverNodeManagers = new();
|
private readonly List<DriverNodeManager> _driverNodeManagers = new();
|
||||||
|
|
||||||
@@ -36,7 +45,9 @@ public sealed class OtOpcUaServer : StandardServer
|
|||||||
AuthorizationGate? authzGate = null,
|
AuthorizationGate? authzGate = null,
|
||||||
NodeScopeResolver? scopeResolver = null,
|
NodeScopeResolver? scopeResolver = null,
|
||||||
Func<string, DriverTier>? tierLookup = null,
|
Func<string, DriverTier>? tierLookup = null,
|
||||||
Func<string, string?>? resilienceConfigLookup = null)
|
Func<string, string?>? resilienceConfigLookup = null,
|
||||||
|
IReadable? virtualReadable = null,
|
||||||
|
IReadable? scriptedAlarmReadable = null)
|
||||||
{
|
{
|
||||||
_driverHost = driverHost;
|
_driverHost = driverHost;
|
||||||
_authenticator = authenticator;
|
_authenticator = authenticator;
|
||||||
@@ -45,6 +56,8 @@ public sealed class OtOpcUaServer : StandardServer
|
|||||||
_scopeResolver = scopeResolver;
|
_scopeResolver = scopeResolver;
|
||||||
_tierLookup = tierLookup;
|
_tierLookup = tierLookup;
|
||||||
_resilienceConfigLookup = resilienceConfigLookup;
|
_resilienceConfigLookup = resilienceConfigLookup;
|
||||||
|
_virtualReadable = virtualReadable;
|
||||||
|
_scriptedAlarmReadable = scriptedAlarmReadable;
|
||||||
_loggerFactory = loggerFactory;
|
_loggerFactory = loggerFactory;
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -77,7 +90,8 @@ public sealed class OtOpcUaServer : StandardServer
|
|||||||
|
|
||||||
var invoker = new CapabilityInvoker(_pipelineBuilder, driver.DriverInstanceId, () => options, driver.DriverType);
|
var invoker = new CapabilityInvoker(_pipelineBuilder, driver.DriverInstanceId, () => options, driver.DriverType);
|
||||||
var manager = new DriverNodeManager(server, configuration, driver, invoker, logger,
|
var manager = new DriverNodeManager(server, configuration, driver, invoker, logger,
|
||||||
authzGate: _authzGate, scopeResolver: _scopeResolver);
|
authzGate: _authzGate, scopeResolver: _scopeResolver,
|
||||||
|
virtualReadable: _virtualReadable, scriptedAlarmReadable: _scriptedAlarmReadable);
|
||||||
_driverNodeManagers.Add(manager);
|
_driverNodeManagers.Add(manager);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||