@@ -512,3 +512,13 @@ T23 ← T17 + T21 T24 ← everything
|
||||
`TryExtractDeviceHost` / `NormalizeDeviceHost` static tests were removed (the statics are deleted); their
|
||||
semantics now live in `Commons.Tests/DeviceConfigIntentTests`. The suite keeps its Compose-level
|
||||
`EquipmentNode.DeviceHost` projection coverage.
|
||||
- **T24 — whole-solution test sweep deferred-live.** The grep gates ran clean offline
|
||||
(`grep "MUST parse identically" src/` = 0; `grep "private static TEnum ReadEnum" src/` = 0) and
|
||||
`dotnet build ZB.MOM.WW.OtOpcUa.slnx` is **0 errors** (812 warnings are all pre-existing OTOPCUA0001 in
|
||||
untouched `*.Tests` projects, none from R2-11). Per the executor memory constraint (integration suites
|
||||
leak ~16 GB/run and other plans run concurrently), only the impacted UNIT suites were run filtered
|
||||
throughout — all green. The whole-solution `dotnet test` is left as the serial heavy pass to run before
|
||||
merge.
|
||||
- **T22 — Writable checkbox live-`/run` deferred.** AdminUI has no bUnit; the 9 model round-trip tests +
|
||||
the razor compile are the offline proof. A docker-dev `/run` of one typed editor's Writable checkbox
|
||||
(rebuild both central-1/2) is the flagged live gate before merge.
|
||||
|
||||
@@ -16,15 +16,15 @@
|
||||
{ "id": "T12", "subject": "Modbus equipment-tag parser: freeze test, shared readers, honour writable key, Inspect warnings", "status": "completed", "blockedBy": ["T11"] },
|
||||
{ "id": "T13", "subject": "S7 equipment-tag parser: freeze test, shared readers, honour writable key, Inspect warnings (+ amend Contracts banner)", "status": "completed", "blockedBy": ["T11"] },
|
||||
{ "id": "T14", "subject": "AbCip equipment-tag parser: freeze test, shared readers (writable already honoured), Inspect warnings", "status": "completed", "blockedBy": ["T11"] },
|
||||
{ "id": "T15", "subject": "AbLegacy equipment-tag parser: freeze test, shared readers, honour writable key, Inspect warnings", "status": "pending", "blockedBy": ["T11"] },
|
||||
{ "id": "T16", "subject": "TwinCAT equipment-tag parser: freeze test, shared readers, honour writable key, Inspect warnings", "status": "pending", "blockedBy": ["T11"] },
|
||||
{ "id": "T17", "subject": "FOCAS equipment-tag parser: force Writable:false (05/UNDER-1 correction), shared readers, Inspect warnings (+ amend Contracts banner)", "status": "pending", "blockedBy": ["T11"] },
|
||||
{ "id": "T18", "subject": "FOCAS capability-matrix pre-flight on the equipment-tag _parseRef resolve path (BadNodeIdUnknown on rejection)", "status": "pending", "blockedBy": ["T17"] },
|
||||
{ "id": "T19", "subject": "Modbus probe parses the factory DTO shape (timeoutMs round-trip; OpcUaClient parity rule)", "status": "pending", "blockedBy": [] },
|
||||
{ "id": "T20", "subject": "EquipmentTagConfigInspector DriverType-dispatch map in ControlPlane (+6 Contracts references)", "status": "pending", "blockedBy": ["T12", "T13", "T14", "T15", "T16", "T17"] },
|
||||
{ "id": "T21", "subject": "AdminOperationsActor deploy-gate wiring + Deployment:TagConfigValidationMode (Warn default | Error opt-in); actor-level consuming test", "status": "pending", "blockedBy": ["T20"] },
|
||||
{ "id": "T22", "subject": "AdminUI writable checkbox in the six driver-typed tag editors (models + razor; live /run verify at execution)", "status": "pending", "blockedBy": [] },
|
||||
{ "id": "T23", "subject": "Docs + decision record: two-mode rollout, unknown-keys non-goal, FOCAS writable migration note, STATUS.md/00-INDEX.md entries + Phase-C follow-up", "status": "pending", "blockedBy": ["T17", "T21"] },
|
||||
{ "id": "T24", "subject": "Final sweep: zero parity-comment/ReadEnum-copy grep hits; whole-solution build + test gate", "status": "pending", "blockedBy": ["T5", "T6", "T7", "T8", "T9", "T10", "T12", "T13", "T14", "T15", "T16", "T17", "T18", "T19", "T21", "T22", "T23"] }
|
||||
{ "id": "T15", "subject": "AbLegacy equipment-tag parser: freeze test, shared readers, honour writable key, Inspect warnings", "status": "completed", "blockedBy": ["T11"] },
|
||||
{ "id": "T16", "subject": "TwinCAT equipment-tag parser: freeze test, shared readers, honour writable key, Inspect warnings", "status": "completed", "blockedBy": ["T11"] },
|
||||
{ "id": "T17", "subject": "FOCAS equipment-tag parser: force Writable:false (05/UNDER-1 correction), shared readers, Inspect warnings (+ amend Contracts banner)", "status": "completed", "blockedBy": ["T11"] },
|
||||
{ "id": "T18", "subject": "FOCAS capability-matrix pre-flight on the equipment-tag _parseRef resolve path (BadNodeIdUnknown on rejection)", "status": "completed", "blockedBy": ["T17"] },
|
||||
{ "id": "T19", "subject": "Modbus probe parses the factory DTO shape (timeoutMs round-trip; OpcUaClient parity rule)", "status": "completed", "blockedBy": [] },
|
||||
{ "id": "T20", "subject": "EquipmentTagConfigInspector DriverType-dispatch map in ControlPlane (+6 Contracts references)", "status": "completed", "blockedBy": ["T12", "T13", "T14", "T15", "T16", "T17"] },
|
||||
{ "id": "T21", "subject": "AdminOperationsActor deploy-gate wiring + Deployment:TagConfigValidationMode (Warn default | Error opt-in); actor-level consuming test", "status": "completed", "blockedBy": ["T20"] },
|
||||
{ "id": "T22", "subject": "AdminUI writable checkbox in the six driver-typed tag editors (models + razor; live /run verify at execution)", "status": "deferred-live", "blockedBy": [] },
|
||||
{ "id": "T23", "subject": "Docs + decision record: two-mode rollout, unknown-keys non-goal, FOCAS writable migration note, STATUS.md/00-INDEX.md entries + Phase-C follow-up", "status": "completed", "blockedBy": ["T17", "T21"] },
|
||||
{ "id": "T24", "subject": "Final sweep: zero parity-comment/ReadEnum-copy grep hits; whole-solution build + test gate", "status": "deferred-live", "blockedBy": ["T5", "T6", "T7", "T8", "T9", "T10", "T12", "T13", "T14", "T15", "T16", "T17", "T18", "T19", "T21", "T22", "T23"] }
|
||||
]
|
||||
}
|
||||
|
||||
@@ -175,6 +175,8 @@ what the unit leg cannot; (c) migrate the 3 xunit v2 holdouts once Akka ships an
|
||||
| **R2-03** | 02/S13 (rank 5), 02/S12, 02/P7 | `r2/03-vt-failure-quality` (off `1676c8f4`) | `b9775485`…`6bb91e8d` (12 task commits) | **Code-complete, offline-verified.** S13: VT script failure/timeout degrades the node to `OpcUaQuality.Bad` (carrying last-known value) instead of freezing on last-Good forever — additive `EvaluationResult.Quality`, bridge historizes `0x80020000u` BadInternalError, published once per Good→Bad transition gated on all deps arrived (inputs-ready, no cold-start flash), recovery force-publishes next Good. S12: apply-boundary `ClearCompiledScripts` racing an in-flight eval into ObjectDisposedException retried once in `RoslynVirtualTagEvaluator` (re-fetch→recompile into current generation); stress guard reproduces pre-fix, deterministically green post-fix. P7: apply-boundary clear gated on a changed deployed expression set (`HashSet.SetEquals`, ordinal) — identical redeploy / rename-with-same-expressions no longer forces full VT recompile. Runtime.Tests 372/372, RoslynVirtualTagEvaluatorTests 20/20. **Deferred (T11/T12):** full cross-suite sweep + docker-dev live-`/run` (fail→Bad→recover + P7 no-recompile spot-check). |
|
||||
| **R2-02** | 01/S-6 (High, rank 2), 01/U-6, 01/S-8=03/S12 (rank 4), 04/C-7, 01/S-7=03/S13 | `r2/02-resilience-config-hardening` (off `1676c8f4`) | `4be13429`…`dd82e740` (17 task commits) | **Code-complete, offline-verified.** **S-6:** parser clamps timeout/retry/breaker overrides (timeout≤0→tier default, breaker==1→2, caps) with diagnostics + belt-and-braces `Build` clamp so pipeline construction can never throw Polly `ValidationException` (new `ResiliencePolicyRanges` in Core.Abstractions); brick-repro + `Build_NeverThrows_ForHostileDirectOptions` + factory-seam wiring proof; AdminUI `Validate()` range warnings. **S-8:** parser forces Write/AlarmAck retry→0 (spec invariant) **and** dispatch flips to `isIdempotent:false` (RED-first on the Runtime wiring test); non-idempotent arm caches the no-retry snapshot once/invoker (01/P-4) + tracker in-flight accounting; `WriteIdempotentAttribute` false claim corrected; retry cells disabled. **U-6:** bulkhead knob deleted end-to-end (migration-free; stored keys ignored) + `Options_properties_are_exactly_the_pipeline_wired_set` inertness guard. **C-7:** `ResilienceFormModel` JsonObject-bag round-trip preserves unknown keys; malformed JSON → `ParseFailed` lock + verbatim `ToJson` + discard button. **S-7:** per-`Create` `Interlocked` options-generation in the pipeline-cache key kills the respawn stale-pipeline race. Core resilience 121/121, AdminUI form 10/10, Analyzers 32/32, Runtime 364/364; 0 production OTOPCUA0001. **Deferred (T15/T18):** docker-dev `:9200` `/run` (warning banner, input lockout, unknown-key survival) + whole-solution sweep. |
|
||||
|
||||
| **R2-11** | 01/C-1, 01/P-1 + 05/CONV-2, UNDER-1, UNDER-6 | `r2/11-tagconfig-consolidation` (off `46fedda3`) | first `2e14fe1f` … (24 task commits) | **Code-complete, offline-verified.** **Part 1 (C-1/P-1):** single `TagConfigIntent.Parse` + `DeviceConfigIntent` in Commons replace the four byte-parity TagConfig parse copies (composer/artifact/walker/DraftValidator) — composer now parses once per tag (P-1); a permanent `Runtime.Tests/TagConfigCorpusParityTests` (30-blob corpus) guards compose≡decode; `grep "MUST parse identically" src/` = 0. **Part 2 (CONV-2):** shared strict-capable `TagConfigJson` readers in Core.Abstractions replace the six copy-pasted `ReadEnum`s; all six driver parsers gain `Inspect()` warnings + honour the `writable` key (FOCAS **forced read-only**, 05/UNDER-1); FOCAS equipment tags run the capability-matrix pre-flight (05/UNDER-6); Modbus probe parses the factory DTO shape (`timeoutMs` no longer dropped). New `EquipmentTagConfigInspector` in ControlPlane + `AdminOperationsActor` deploy-gate wiring with `Deployment:TagConfigValidationMode` (**Warn default | Error opt-in**), proven through the actor (F10b consuming test). AdminUI: `writable` checkbox in the six typed editors. **Phase-C follow-up (deferred, recorded here):** flip the runtime parsers to strict (typo'd enum ⇒ `BadNodeIdUnknown` instead of wrong-width `Good`) once fleets have run `Error` mode clean — behavior change deliberately not shipped in this plan. **Deferred (T22/T24):** docker-dev `/run` of one typed editor's Writable checkbox + whole-solution serial sweep. |
|
||||
|
||||
**Report anchor drifts to fold into the next report refresh** (from the R2-02 verification pass): (1)
|
||||
`01-core-composition.md` U-6 anchor `DriverResilienceOptions.cs:23-25` → the two bulkhead properties sat at
|
||||
`:23` and `:29` (now deleted); (2) `01-core-composition.md` U-6 anchor
|
||||
|
||||
+47
@@ -231,6 +231,53 @@ Combined with historization (values are arrays — history of the whole array sn
|
||||
|
||||
See the individual driver docs under `docs/drivers/` for per-driver implementation details.
|
||||
|
||||
## Writable equipment tags (`writable` key)
|
||||
|
||||
An equipment tag is **writable by default** — the materialised OPC UA node is created
|
||||
`CurrentReadWrite` and inbound client writes are routed to the device (subject to the
|
||||
`WriteOperate` LDAP role gate). Setting the optional `"writable": false` key in a tag's
|
||||
`TagConfig` makes the node **read-only** at the driver seam. The six typed tag editors
|
||||
(Modbus, S7, AB CIP, AB Legacy, TwinCAT, FOCAS) expose this as a **Writable** checkbox
|
||||
(checked by default); it can also be hand-authored in the raw-JSON textarea.
|
||||
|
||||
| Condition | Node |
|
||||
|---|---|
|
||||
| `writable` absent | Writable (driver default) — existing configs are unchanged |
|
||||
| `writable: false` | Read-only |
|
||||
| `writable: true` | Writable |
|
||||
|
||||
The key is honoured by Modbus, S7, AB CIP, AB Legacy, and TwinCAT. **FOCAS forces
|
||||
read-only regardless** — FOCAS PMC writes are unsupported in the wire client, so its
|
||||
editor shows the checkbox disabled/unchecked and any authored `writable:true` is ignored
|
||||
(and flagged at the deploy gate below). Node-level authz (LDAP `WriteOperate`) remains the
|
||||
effective write gate above this flag.
|
||||
|
||||
## Deploy-time TagConfig validation (`Deployment:TagConfigValidationMode`)
|
||||
|
||||
The deploy gate inspects every equipment tag's `TagConfig` per its bound driver type and
|
||||
surfaces **strictness warnings** — a present-but-invalid enum value (e.g. a typo'd
|
||||
`dataType`, which the lenient runtime silently defaults to the wrong width with `Good`
|
||||
status), a structurally-unparseable TagConfig, or (FOCAS) an authored `writable:true`.
|
||||
|
||||
The behaviour is controlled by `Deployment:TagConfigValidationMode` in `appsettings.json`:
|
||||
|
||||
| Mode | Behaviour |
|
||||
|---|---|
|
||||
| `Warn` (default) | Non-blocking: warnings are logged and appended to the deployment result message; the deploy still succeeds. Existing configs never break. |
|
||||
| `Error` | Blocking: warnings fold into the draft-gate reject list — a config with a typo'd enum (or unparseable TagConfig) cannot be re-deployed until fixed. Opt-in per environment once the fleet deploys warning-clean. |
|
||||
|
||||
Running servers are untouched either way — the gate only sees re-deploys. Unmapped drivers
|
||||
(Galaxy, OpcUaClient) are skipped. **Unknown keys are never warned on**: the `TagConfig`
|
||||
blob is a shared namespace (platform intent keys coexist with per-driver address keys and
|
||||
forward-compat keys the typed editors preserve), so there is no single schema to validate
|
||||
against — parsers read known fields and ignore the rest by design.
|
||||
|
||||
> **Note (runtime strictness is deferred).** In this release the runtime parsers stay
|
||||
> *lenient* (a typo'd enum still silently defaults) — only the deploy gate reports it.
|
||||
> Flipping the runtime parsers to strict (a typo'd enum ⇒ `BadNodeIdUnknown` instead of a
|
||||
> wrong-width `Good`) is a deliberate future phase, to be taken only after fleets have run
|
||||
> `Error` mode clean. Tracked in `archreview/plans/STATUS.md`.
|
||||
|
||||
## Galaxy address picker — native-alarm pre-fill
|
||||
|
||||
When the Galaxy address picker selects an attribute that is itself an alarm
|
||||
|
||||
@@ -15,6 +15,16 @@ OtOpcUa is **read-only** against FOCAS; all reads go over the native wire
|
||||
protocol using the documented command IDs. Writes return
|
||||
`BadNotWritable` by design.
|
||||
|
||||
> **Equipment tags are forced read-only (R2-11, migration note).** The equipment-tag parser
|
||||
> (`FocasEquipmentTagParser`) now hard-codes `Writable: false` regardless of any authored
|
||||
> `"writable": true` — previously such a tag advertised a writable node whose write always failed at
|
||||
> the wire with `BadNotWritable`; now it fails one step earlier at the driver seam (same family of Bad
|
||||
> status, no successful operation changes). The AdminUI FOCAS editor shows the Writable checkbox
|
||||
> disabled/unchecked, and the deploy gate warns when a config requests `writable:true`. Additionally,
|
||||
> equipment-tag references now run the same capability-matrix pre-flight authored tags get: a reference
|
||||
> whose address violates the device series' matrix fails to resolve (`BadNodeIdUnknown`) instead of
|
||||
> reaching the wire. Honour `writable` here once PMC writes ship in the wire client.
|
||||
|
||||
> **PDU version (v3 / FANUC 30i/31i).** The wire client **accepts inbound PDU versions `{1, 3}`**
|
||||
> (`FocasWireProtocol`) while still emitting v1 on requests. Older controls + the docker mock answer
|
||||
> v1; modern controls (Makino Pro 5 / FANUC **31i-B**) answer v3. **Validated live against a real
|
||||
|
||||
+35
-5
@@ -1,4 +1,5 @@
|
||||
using System.Text.Json;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
|
||||
|
||||
@@ -38,7 +39,7 @@ public static class AbLegacyEquipmentTagParser
|
||||
return false;
|
||||
var address = addr.GetString();
|
||||
if (string.IsNullOrWhiteSpace(address)) return false;
|
||||
var dataType = ReadEnum(root, "dataType", AbLegacyDataType.Int);
|
||||
var dataType = TagConfigJson.ReadEnumOrDefault(root, "dataType", AbLegacyDataType.Int);
|
||||
var deviceHostAddress = ReadString(root, "deviceHostAddress");
|
||||
int? arrayLength = null;
|
||||
if (IsArrayFlag(root))
|
||||
@@ -47,9 +48,12 @@ public static class AbLegacyEquipmentTagParser
|
||||
if (rawLength >= 1)
|
||||
arrayLength = Math.Min(rawLength, AbLegacyArray.MaxElements);
|
||||
}
|
||||
// "writable" defaults to true when absent (today's value) — makes read-only equipment tags
|
||||
// authorable (UNDER-6).
|
||||
var writable = TagConfigJson.ReadWritable(root);
|
||||
def = new AbLegacyTagDefinition(
|
||||
Name: reference, DeviceHostAddress: deviceHostAddress, Address: address,
|
||||
DataType: dataType, Writable: true, ArrayLength: arrayLength);
|
||||
DataType: dataType, Writable: writable, ArrayLength: arrayLength);
|
||||
return true;
|
||||
}
|
||||
catch (JsonException) { return false; }
|
||||
@@ -57,9 +61,35 @@ public static class AbLegacyEquipmentTagParser
|
||||
catch (InvalidOperationException) { return false; }
|
||||
}
|
||||
|
||||
private static TEnum ReadEnum<TEnum>(JsonElement o, string name, TEnum fallback) where TEnum : struct, Enum
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.String
|
||||
&& Enum.TryParse<TEnum>(e.GetString(), ignoreCase: true, out var v) ? v : fallback;
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns on a present-but-invalid <c>dataType</c> (silently
|
||||
/// defaulted by the lenient runtime) and on a structurally unparseable TagConfig. Empty when clean
|
||||
/// or not an equipment-tag object. Never throws.
|
||||
/// </summary>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
var root = doc.RootElement;
|
||||
if (root.ValueKind != JsonValueKind.Object)
|
||||
{
|
||||
warnings.Add("AbLegacy TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
var w = TagConfigJson.DescribeInvalidEnum<AbLegacyDataType>(root, "dataType");
|
||||
if (w is not null) warnings.Add(w);
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("AbLegacy TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
return warnings;
|
||||
}
|
||||
|
||||
private static string ReadString(JsonElement o, string name)
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.String
|
||||
|
||||
+5
-1
@@ -5,5 +5,9 @@
|
||||
<ImplicitUsings>enable</ImplicitUsings>
|
||||
<TreatWarningsAsErrors>true</TreatWarningsAsErrors>
|
||||
</PropertyGroup>
|
||||
<!-- NO PackageReference. -->
|
||||
<!-- NO PackageReference. ProjectReference only to the zero-dependency Core.Abstractions leaf
|
||||
(R2-11 05/CONV-2 — shared TagConfigJson readers). -->
|
||||
<ItemGroup>
|
||||
<ProjectReference Include="..\..\Core\ZB.MOM.WW.OtOpcUa.Core.Abstractions\ZB.MOM.WW.OtOpcUa.Core.Abstractions.csproj"/>
|
||||
</ItemGroup>
|
||||
</Project>
|
||||
|
||||
@@ -1,4 +1,5 @@
|
||||
using System.Text.Json;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
|
||||
|
||||
@@ -28,11 +29,17 @@ public static class FocasEquipmentTagParser
|
||||
return false;
|
||||
var address = addr.GetString();
|
||||
if (string.IsNullOrWhiteSpace(address)) return false;
|
||||
var dataType = ReadEnum(root, "dataType", FocasDataType.Int32);
|
||||
var dataType = TagConfigJson.ReadEnumOrDefault(root, "dataType", FocasDataType.Int32);
|
||||
var deviceHostAddress = ReadString(root, "deviceHostAddress") ?? "";
|
||||
def = new FocasTagDefinition(
|
||||
Name: reference, DeviceHostAddress: deviceHostAddress, Address: address,
|
||||
DataType: dataType, Writable: true);
|
||||
// FOCAS equipment tags are FORCED read-only (05/UNDER-1): the only wire client
|
||||
// (WireFocasClient.cs:71-73) returns BadNotWritable for EVERY address, so advertising a
|
||||
// writable node is a lie — a write that used to reach the backend and always fail with
|
||||
// BadNotWritable now fails at the driver seam with the same family of Bad status (no
|
||||
// successful operation changes). Any authored `writable:true` is ignored + warned by
|
||||
// Inspect. Honour the key here once PMC writes ship in the wire client.
|
||||
DataType: dataType, Writable: false);
|
||||
return true;
|
||||
}
|
||||
catch (JsonException) { return false; }
|
||||
@@ -40,9 +47,38 @@ public static class FocasEquipmentTagParser
|
||||
catch (InvalidOperationException) { return false; }
|
||||
}
|
||||
|
||||
private static TEnum ReadEnum<TEnum>(JsonElement o, string name, TEnum fallback) where TEnum : struct, Enum
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.String
|
||||
&& Enum.TryParse<TEnum>(e.GetString(), ignoreCase: true, out var v) ? v : fallback;
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2, 05/UNDER-1): warns on a present-but-invalid <c>dataType</c>
|
||||
/// (silently defaulted by the lenient runtime), on an authored <c>writable:true</c> (FOCAS writes
|
||||
/// are unsupported — the tag is forced read-only), and on a structurally unparseable TagConfig.
|
||||
/// Empty when clean or not an equipment-tag object. Never throws.
|
||||
/// </summary>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
var root = doc.RootElement;
|
||||
if (root.ValueKind != JsonValueKind.Object)
|
||||
{
|
||||
warnings.Add("FOCAS TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
var w = TagConfigJson.DescribeInvalidEnum<FocasDataType>(root, "dataType");
|
||||
if (w is not null) warnings.Add(w);
|
||||
if (root.TryGetProperty("writable", out var wr) && wr.ValueKind == JsonValueKind.True)
|
||||
warnings.Add("FOCAS writes unsupported — 'writable:true' is ignored; the tag is forced read-only until PMC writes exist.");
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("FOCAS TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
return warnings;
|
||||
}
|
||||
|
||||
private static string? ReadString(JsonElement o, string name)
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.String ? e.GetString() : null;
|
||||
|
||||
+6
-1
@@ -5,5 +5,10 @@
|
||||
<ImplicitUsings>enable</ImplicitUsings>
|
||||
<TreatWarningsAsErrors>true</TreatWarningsAsErrors>
|
||||
</PropertyGroup>
|
||||
<!-- NO PackageReference. NO ProjectReference. -->
|
||||
<!-- NO PackageReference. ProjectReference only to the zero-dependency Core.Abstractions leaf
|
||||
(R2-11 05/CONV-2 — shared TagConfigJson readers beside EquipmentTagRefResolver; no
|
||||
dependency-closure growth for lightweight AdminUI/Cli consumers). -->
|
||||
<ItemGroup>
|
||||
<ProjectReference Include="..\..\Core\ZB.MOM.WW.OtOpcUa.Core.Abstractions\ZB.MOM.WW.OtOpcUa.Core.Abstractions.csproj"/>
|
||||
</ItemGroup>
|
||||
</Project>
|
||||
|
||||
@@ -68,7 +68,7 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
_logger = logger ?? NullLogger<FocasDriver>.Instance;
|
||||
_resolver = new EquipmentTagRefResolver<FocasTagDefinition>(
|
||||
r => _tagsByName.TryGetValue(r, out var t) ? t : null,
|
||||
r => FocasEquipmentTagParser.TryParse(r, out var d) ? d : null);
|
||||
ResolveEquipmentTagRef);
|
||||
_poll = new PollGroupEngine(
|
||||
reader: ReadAsync,
|
||||
onChange: (handle, tagRef, snapshot) =>
|
||||
@@ -234,6 +234,20 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
internal bool IsParsedAddressCached(string reference) =>
|
||||
_parsedAddressesByTagName.ContainsKey(reference);
|
||||
|
||||
// Resolves an equipment-tag TagConfig reference into a FocasTagDefinition, applying the SAME
|
||||
// capability pre-flight authored tags get at InitializeAsync (:105-119) — R2-11 (05/UNDER-6). A
|
||||
// reference whose address is unparseable, whose bound device is unknown, or whose address violates
|
||||
// the device series' capability matrix returns null ⇒ resolver miss ⇒ BadNodeIdUnknown at read time,
|
||||
// instead of a wrong-status read reaching the wire. The negative is cached by the resolver.
|
||||
private FocasTagDefinition? ResolveEquipmentTagRef(string reference)
|
||||
{
|
||||
if (!FocasEquipmentTagParser.TryParse(reference, out var def)) return null;
|
||||
var parsed = FocasAddress.TryParse(def.Address);
|
||||
if (parsed is null) return null;
|
||||
if (!_devices.TryGetValue(def.DeviceHostAddress, out var device)) return null;
|
||||
return FocasCapabilityMatrix.Validate(device.Options.Series, parsed) is null ? def : null;
|
||||
}
|
||||
|
||||
// Resolves a tag definition to its parsed FocasAddress, caching the result so that
|
||||
// equipment tags (resolver-produced, not seeded at InitializeAsync) don't re-parse the
|
||||
// address string on every ReadAsync / WriteAsync hot-path call.
|
||||
|
||||
@@ -29,19 +29,44 @@ public sealed class ModbusDriverProbe : IDriverProbe
|
||||
/// <inheritdoc />
|
||||
public string DriverType => "Modbus";
|
||||
|
||||
/// <summary>The parsed probe target — host/port/unitId + the effective connection timeout, all read
|
||||
/// from the SAME factory DTO shape (<c>ModbusDriverConfigDto</c>) the driver factory parses, so
|
||||
/// <c>timeoutMs</c> binds identically to the factory (R2-11, 05/CONV-2; the OpcUaClient parity rule).</summary>
|
||||
internal readonly record struct ProbeTarget(string Host, int Port, byte UnitId, TimeSpan Timeout);
|
||||
|
||||
/// <summary>Parse the driver config JSON into a <see cref="ProbeTarget"/> using the factory DTO shape.
|
||||
/// Returns a null target + an error message when the JSON is invalid or has no host/port. The effective
|
||||
/// timeout mirrors the factory (<c>TimeSpan.FromMilliseconds(dto.TimeoutMs ?? …)</c>); when the config
|
||||
/// omits <c>timeoutMs</c> the caller's <paramref name="fallbackTimeout"/> is used.</summary>
|
||||
/// <param name="configJson">The driver config JSON (factory DTO shape).</param>
|
||||
/// <param name="fallbackTimeout">The timeout used when the config omits <c>timeoutMs</c>.</param>
|
||||
/// <returns>The parsed target, or a null target with an error string.</returns>
|
||||
internal static (ProbeTarget? Target, string? Error) TryParseProbeTarget(string configJson, TimeSpan fallbackTimeout)
|
||||
{
|
||||
ModbusDriverFactoryExtensions.ModbusDriverConfigDto? dto;
|
||||
try { dto = JsonSerializer.Deserialize<ModbusDriverFactoryExtensions.ModbusDriverConfigDto>(configJson, _opts); }
|
||||
catch (Exception ex) { return (null, $"Config JSON is invalid: {ex.Message}"); }
|
||||
if (dto is null) return (null, "Config JSON deserialized to null.");
|
||||
|
||||
var port = dto.Port ?? 502;
|
||||
if (string.IsNullOrWhiteSpace(dto.Host) || port <= 0)
|
||||
return (null, "Config has no host/port to probe.");
|
||||
|
||||
var timeout = dto.TimeoutMs is { } ms && ms > 0 ? TimeSpan.FromMilliseconds(ms) : fallbackTimeout;
|
||||
return (new ProbeTarget(dto.Host!, port, dto.UnitId ?? 1, timeout), null);
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public async Task<DriverProbeResult> ProbeAsync(string configJson, TimeSpan timeout, CancellationToken ct)
|
||||
{
|
||||
ModbusDriverOptions? opts;
|
||||
try { opts = JsonSerializer.Deserialize<ModbusDriverOptions>(configJson, _opts); }
|
||||
catch (Exception ex) { return new(false, $"Config JSON is invalid: {ex.Message}", null); }
|
||||
if (opts is null) return new(false, "Config JSON deserialized to null.", null);
|
||||
var (target, error) = TryParseProbeTarget(configJson, timeout);
|
||||
if (target is not { } t) return new(false, error!, null);
|
||||
|
||||
var (host, port) = ExtractTarget(opts);
|
||||
if (string.IsNullOrWhiteSpace(host) || port <= 0)
|
||||
return new(false, "Config has no host/port to probe.", null);
|
||||
|
||||
var unitId = opts.UnitId;
|
||||
var host = t.Host;
|
||||
var port = t.Port;
|
||||
var unitId = t.UnitId;
|
||||
// Honour the config's timeoutMs (factory parity) — the caller's timeout is the fallback.
|
||||
timeout = t.Timeout;
|
||||
|
||||
var sw = Stopwatch.StartNew();
|
||||
using var cts = CancellationTokenSource.CreateLinkedTokenSource(ct);
|
||||
@@ -93,7 +118,4 @@ public sealed class ModbusDriverProbe : IDriverProbe
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
private static (string host, int port) ExtractTarget(ModbusDriverOptions opts)
|
||||
=> (opts.Host, opts.Port);
|
||||
}
|
||||
|
||||
+35
-5
@@ -1,4 +1,5 @@
|
||||
using System.Text.Json;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.TwinCAT;
|
||||
|
||||
@@ -28,15 +29,18 @@ public static class TwinCATEquipmentTagParser
|
||||
var symbolPath = symbol.GetString();
|
||||
if (string.IsNullOrWhiteSpace(symbolPath)) return false;
|
||||
var deviceHostAddress = ReadString(root, "deviceHostAddress");
|
||||
var dataType = ReadEnum(root, "dataType", TwinCATDataType.DInt);
|
||||
var dataType = TagConfigJson.ReadEnumOrDefault(root, "dataType", TwinCATDataType.DInt);
|
||||
// Array intent — same shape the runtime/OPC-UA foundation parses (camelCase
|
||||
// `isArray` bool + `arrayLength` uint). arrayLength is honoured ONLY when isArray
|
||||
// is true AND it is a positive JSON number, so a stale length behind a cleared
|
||||
// isArray never produces an orphan array tag (Phase 4c).
|
||||
var arrayLength = ReadArrayLength(root);
|
||||
// "writable" defaults to true when absent (today's value) — makes read-only equipment tags
|
||||
// authorable (UNDER-6).
|
||||
var writable = TagConfigJson.ReadWritable(root);
|
||||
def = new TwinCATTagDefinition(
|
||||
Name: reference, DeviceHostAddress: deviceHostAddress, SymbolPath: symbolPath,
|
||||
DataType: dataType, Writable: true, ArrayLength: arrayLength);
|
||||
DataType: dataType, Writable: writable, ArrayLength: arrayLength);
|
||||
return true;
|
||||
}
|
||||
catch (JsonException) { return false; }
|
||||
@@ -44,9 +48,35 @@ public static class TwinCATEquipmentTagParser
|
||||
catch (InvalidOperationException) { return false; }
|
||||
}
|
||||
|
||||
private static TEnum ReadEnum<TEnum>(JsonElement o, string name, TEnum fallback) where TEnum : struct, Enum
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.String
|
||||
&& Enum.TryParse<TEnum>(e.GetString(), ignoreCase: true, out var v) ? v : fallback;
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns on a present-but-invalid <c>dataType</c> (silently
|
||||
/// defaulted by the lenient runtime) and on a structurally unparseable TagConfig. Empty when clean
|
||||
/// or not an equipment-tag object. Never throws.
|
||||
/// </summary>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
var root = doc.RootElement;
|
||||
if (root.ValueKind != JsonValueKind.Object)
|
||||
{
|
||||
warnings.Add("TwinCAT TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
var w = TagConfigJson.DescribeInvalidEnum<TwinCATDataType>(root, "dataType");
|
||||
if (w is not null) warnings.Add(w);
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("TwinCAT TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
return warnings;
|
||||
}
|
||||
|
||||
private static string ReadString(JsonElement o, string name)
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.String
|
||||
|
||||
+5
-1
@@ -5,5 +5,9 @@
|
||||
<ImplicitUsings>enable</ImplicitUsings>
|
||||
<TreatWarningsAsErrors>true</TreatWarningsAsErrors>
|
||||
</PropertyGroup>
|
||||
<!-- NO PackageReference. -->
|
||||
<!-- NO PackageReference. ProjectReference only to the zero-dependency Core.Abstractions leaf
|
||||
(R2-11 05/CONV-2 — shared TagConfigJson readers). -->
|
||||
<ItemGroup>
|
||||
<ProjectReference Include="..\..\Core\ZB.MOM.WW.OtOpcUa.Core.Abstractions\ZB.MOM.WW.OtOpcUa.Core.Abstractions.csproj"/>
|
||||
</ItemGroup>
|
||||
</Project>
|
||||
|
||||
+8
@@ -17,6 +17,14 @@
|
||||
<select class="form-select form-select-sm" value="@_m.DataType" @onchange="@(e => Update(() => _m.DataType = ParseEnum(e.Value, AbCipDataType.DInt)))">
|
||||
@foreach (var v in Enum.GetValues<AbCipDataType>()) { <option value="@v">@v</option> }
|
||||
</select></div>
|
||||
<div class="col-12">
|
||||
<div class="form-check">
|
||||
<input type="checkbox" class="form-check-input" id="abcip-writable"
|
||||
checked="@(_m.Writable ?? true)"
|
||||
@onchange="@(e => Update(() => _m.Writable = e.Value is bool b && b))" />
|
||||
<label class="form-check-label small" for="abcip-writable">Writable (uncheck for a read-only tag)</label>
|
||||
</div>
|
||||
</div>
|
||||
</div>
|
||||
|
||||
@if (_showPicker)
|
||||
|
||||
+8
@@ -17,6 +17,14 @@
|
||||
<select class="form-select form-select-sm" value="@_m.DataType" @onchange="@(e => Update(() => _m.DataType = ParseEnum(e.Value, AbLegacyDataType.Int)))">
|
||||
@foreach (var v in Enum.GetValues<AbLegacyDataType>()) { <option value="@v">@v</option> }
|
||||
</select></div>
|
||||
<div class="col-12">
|
||||
<div class="form-check">
|
||||
<input type="checkbox" class="form-check-input" id="ablegacy-writable"
|
||||
checked="@(_m.Writable ?? true)"
|
||||
@onchange="@(e => Update(() => _m.Writable = e.Value is bool b && b))" />
|
||||
<label class="form-check-label small" for="ablegacy-writable">Writable (uncheck for a read-only tag)</label>
|
||||
</div>
|
||||
</div>
|
||||
</div>
|
||||
|
||||
@if (_showPicker)
|
||||
|
||||
+6
@@ -17,6 +17,12 @@
|
||||
<select class="form-select form-select-sm" value="@_m.DataType" @onchange="@(e => Update(() => _m.DataType = ParseEnum(e.Value, FocasDataType.Int32)))">
|
||||
@foreach (var v in Enum.GetValues<FocasDataType>()) { <option value="@v">@v</option> }
|
||||
</select></div>
|
||||
<div class="col-12">
|
||||
<div class="form-check">
|
||||
<input type="checkbox" class="form-check-input" id="focas-writable" disabled checked="false" />
|
||||
<label class="form-check-label small text-muted" for="focas-writable">Writable — FOCAS writes are unsupported; tags are read-only.</label>
|
||||
</div>
|
||||
</div>
|
||||
</div>
|
||||
|
||||
@if (_showPicker)
|
||||
|
||||
+8
@@ -25,6 +25,14 @@
|
||||
<div class="col-12 mt-1">
|
||||
<button type="button" class="btn btn-sm btn-outline-secondary" @onclick="@(() => _showPicker = true)">Build address</button>
|
||||
</div>
|
||||
<div class="col-12">
|
||||
<div class="form-check">
|
||||
<input type="checkbox" class="form-check-input" id="modbus-writable"
|
||||
checked="@(_m.Writable ?? true)"
|
||||
@onchange="@(e => Update(() => _m.Writable = e.Value is bool b && b))" />
|
||||
<label class="form-check-label small" for="modbus-writable">Writable (uncheck for a read-only tag)</label>
|
||||
</div>
|
||||
</div>
|
||||
</div>
|
||||
|
||||
@if (_showPicker)
|
||||
|
||||
+8
@@ -17,6 +17,14 @@
|
||||
</select></div>
|
||||
<div class="col-md-3"><label class="form-label">String len</label>
|
||||
<input type="number" class="form-control form-control-sm" value="@_m.StringLength" @onchange="@(e => Update(() => _m.StringLength = ParseInt(e.Value)))" /></div>
|
||||
<div class="col-12">
|
||||
<div class="form-check">
|
||||
<input type="checkbox" class="form-check-input" id="s7-writable"
|
||||
checked="@(_m.Writable ?? true)"
|
||||
@onchange="@(e => Update(() => _m.Writable = e.Value is bool b && b))" />
|
||||
<label class="form-check-label small" for="s7-writable">Writable (uncheck for a read-only tag)</label>
|
||||
</div>
|
||||
</div>
|
||||
</div>
|
||||
|
||||
@if (_showPicker)
|
||||
|
||||
+8
@@ -17,6 +17,14 @@
|
||||
<select class="form-select form-select-sm" value="@_m.DataType" @onchange="@(e => Update(() => _m.DataType = ParseEnum(e.Value, TwinCATDataType.DInt)))">
|
||||
@foreach (var v in Enum.GetValues<TwinCATDataType>()) { <option value="@v">@v</option> }
|
||||
</select></div>
|
||||
<div class="col-12">
|
||||
<div class="form-check">
|
||||
<input type="checkbox" class="form-check-input" id="twincat-writable"
|
||||
checked="@(_m.Writable ?? true)"
|
||||
@onchange="@(e => Update(() => _m.Writable = e.Value is bool b && b))" />
|
||||
<label class="form-check-label small" for="twincat-writable">Writable (uncheck for a read-only tag)</label>
|
||||
</div>
|
||||
</div>
|
||||
</div>
|
||||
|
||||
@if (_showPicker)
|
||||
|
||||
@@ -16,6 +16,10 @@ public sealed class AbCipTagConfigModel
|
||||
/// <summary>Logix atomic type, or <c>AbCipDataType.Structure</c> for UDT-typed tags.</summary>
|
||||
public AbCipDataType DataType { get; set; } = AbCipDataType.DInt;
|
||||
|
||||
/// <summary>Optional writable flag (R2-11); <c>null</c> ⇒ omitted (driver default true), explicit
|
||||
/// <c>false</c> ⇒ read-only. Preserved across load→save.</summary>
|
||||
public bool? Writable { get; set; }
|
||||
|
||||
private JsonObject _bag = new();
|
||||
|
||||
/// <summary>Loads a model from a TagConfig JSON string, defaulting any absent field and retaining
|
||||
@@ -30,6 +34,7 @@ public sealed class AbCipTagConfigModel
|
||||
DeviceHostAddress = TagConfigJson.GetString(o, "deviceHostAddress") ?? "",
|
||||
TagPath = TagConfigJson.GetString(o, "tagPath") ?? "",
|
||||
DataType = TagConfigJson.GetEnum(o, "dataType", AbCipDataType.DInt),
|
||||
Writable = TagConfigJson.GetBoolNullable(o, "writable"),
|
||||
_bag = o,
|
||||
};
|
||||
}
|
||||
@@ -42,6 +47,7 @@ public sealed class AbCipTagConfigModel
|
||||
TagConfigJson.Set(_bag, "deviceHostAddress", string.IsNullOrWhiteSpace(DeviceHostAddress) ? null : DeviceHostAddress.Trim());
|
||||
TagConfigJson.Set(_bag, "tagPath", TagPath.Trim());
|
||||
TagConfigJson.Set(_bag, "dataType", DataType);
|
||||
TagConfigJson.Set(_bag, "writable", Writable);
|
||||
return TagConfigJson.Serialize(_bag);
|
||||
}
|
||||
|
||||
|
||||
@@ -16,6 +16,10 @@ public sealed class AbLegacyTagConfigModel
|
||||
/// <summary>PCCC data type that maps onto SLC / MicroLogix / PLC-5 files.</summary>
|
||||
public AbLegacyDataType DataType { get; set; } = AbLegacyDataType.Int;
|
||||
|
||||
/// <summary>Optional writable flag (R2-11); <c>null</c> ⇒ omitted (driver default true), explicit
|
||||
/// <c>false</c> ⇒ read-only. Preserved across load→save.</summary>
|
||||
public bool? Writable { get; set; }
|
||||
|
||||
private JsonObject _bag = new();
|
||||
|
||||
/// <summary>Loads a model from a TagConfig JSON string, defaulting any absent field and retaining
|
||||
@@ -30,6 +34,7 @@ public sealed class AbLegacyTagConfigModel
|
||||
DeviceHostAddress = TagConfigJson.GetString(o, "deviceHostAddress") ?? "",
|
||||
Address = TagConfigJson.GetString(o, "address") ?? "",
|
||||
DataType = TagConfigJson.GetEnum(o, "dataType", AbLegacyDataType.Int),
|
||||
Writable = TagConfigJson.GetBoolNullable(o, "writable"),
|
||||
_bag = o,
|
||||
};
|
||||
}
|
||||
@@ -42,6 +47,7 @@ public sealed class AbLegacyTagConfigModel
|
||||
TagConfigJson.Set(_bag, "deviceHostAddress", string.IsNullOrWhiteSpace(DeviceHostAddress) ? null : DeviceHostAddress.Trim());
|
||||
TagConfigJson.Set(_bag, "address", Address.Trim());
|
||||
TagConfigJson.Set(_bag, "dataType", DataType);
|
||||
TagConfigJson.Set(_bag, "writable", Writable);
|
||||
return TagConfigJson.Serialize(_bag);
|
||||
}
|
||||
|
||||
|
||||
@@ -25,6 +25,11 @@ public sealed class ModbusTagConfigModel
|
||||
/// <summary>String length in characters for String tags.</summary>
|
||||
public int StringLength { get; set; }
|
||||
|
||||
/// <summary>Optional writable flag (R2-11). <c>null</c> ⇒ the key is omitted (driver default true);
|
||||
/// an explicit <c>false</c> makes the equipment tag read-only. Preserved across load→save so an absent
|
||||
/// key stays absent.</summary>
|
||||
public bool? Writable { get; set; }
|
||||
|
||||
private JsonObject _bag = new();
|
||||
|
||||
/// <summary>Loads a model from a TagConfig JSON string, defaulting any absent field and retaining
|
||||
@@ -42,6 +47,7 @@ public sealed class ModbusTagConfigModel
|
||||
ByteOrder = TagConfigJson.GetEnum(o, "byteOrder", ModbusByteOrder.BigEndian),
|
||||
BitIndex = TagConfigJson.GetInt(o, "bitIndex"),
|
||||
StringLength = TagConfigJson.GetInt(o, "stringLength"),
|
||||
Writable = TagConfigJson.GetBoolNullable(o, "writable"),
|
||||
_bag = o,
|
||||
};
|
||||
}
|
||||
@@ -57,6 +63,7 @@ public sealed class ModbusTagConfigModel
|
||||
TagConfigJson.Set(_bag, "byteOrder", ByteOrder);
|
||||
TagConfigJson.Set(_bag, "bitIndex", BitIndex);
|
||||
TagConfigJson.Set(_bag, "stringLength", StringLength);
|
||||
TagConfigJson.Set(_bag, "writable", Writable);
|
||||
return TagConfigJson.Serialize(_bag);
|
||||
}
|
||||
|
||||
|
||||
@@ -16,6 +16,10 @@ public sealed class S7TagConfigModel
|
||||
/// <summary>For <c>DataType = String</c>: S7-string max length (max 254).</summary>
|
||||
public int StringLength { get; set; }
|
||||
|
||||
/// <summary>Optional writable flag (R2-11); <c>null</c> ⇒ omitted (driver default true), explicit
|
||||
/// <c>false</c> ⇒ read-only. Preserved across load→save.</summary>
|
||||
public bool? Writable { get; set; }
|
||||
|
||||
private JsonObject _bag = new();
|
||||
|
||||
/// <summary>Loads a model from a TagConfig JSON string, defaulting any absent field and retaining
|
||||
@@ -30,6 +34,7 @@ public sealed class S7TagConfigModel
|
||||
Address = TagConfigJson.GetString(o, "address") ?? "",
|
||||
DataType = TagConfigJson.GetEnum(o, "dataType", S7DataType.Int16),
|
||||
StringLength = TagConfigJson.GetInt(o, "stringLength"),
|
||||
Writable = TagConfigJson.GetBoolNullable(o, "writable"),
|
||||
_bag = o,
|
||||
};
|
||||
}
|
||||
@@ -42,6 +47,7 @@ public sealed class S7TagConfigModel
|
||||
TagConfigJson.Set(_bag, "address", Address.Trim());
|
||||
TagConfigJson.Set(_bag, "dataType", DataType);
|
||||
TagConfigJson.Set(_bag, "stringLength", StringLength);
|
||||
TagConfigJson.Set(_bag, "writable", Writable);
|
||||
return TagConfigJson.Serialize(_bag);
|
||||
}
|
||||
|
||||
|
||||
@@ -48,6 +48,14 @@ public static class TagConfigJson
|
||||
public static bool GetBool(JsonObject o, string name, bool fallback = false)
|
||||
=> o.TryGetPropertyValue(name, out var n) && n is JsonValue v && v.TryGetValue<bool>(out var b) ? b : fallback;
|
||||
|
||||
/// <summary>Reads a bool value, or <c>null</c> when the property is absent/null/non-boolean — so an
|
||||
/// absent key stays absent through a load→save (distinguishes "not set" from an explicit false).</summary>
|
||||
/// <param name="o">The JSON object to read from.</param>
|
||||
/// <param name="name">The property name to read.</param>
|
||||
/// <returns>The bool value, or <c>null</c> when absent/null/non-boolean.</returns>
|
||||
public static bool? GetBoolNullable(JsonObject o, string name)
|
||||
=> o.TryGetPropertyValue(name, out var n) && n is JsonValue v && v.TryGetValue<bool>(out var b) ? b : null;
|
||||
|
||||
/// <summary>Reads an enum by its serialised name, or <paramref name="fallback"/> if absent/unparseable.</summary>
|
||||
/// <typeparam name="TEnum">The enum type to parse.</typeparam>
|
||||
/// <param name="o">The JSON object to read from.</param>
|
||||
|
||||
@@ -16,6 +16,10 @@ public sealed class TwinCATTagConfigModel
|
||||
/// <summary>TwinCAT / IEC 61131-3 atomic data type.</summary>
|
||||
public TwinCATDataType DataType { get; set; } = TwinCATDataType.DInt;
|
||||
|
||||
/// <summary>Optional writable flag (R2-11); <c>null</c> ⇒ omitted (driver default true), explicit
|
||||
/// <c>false</c> ⇒ read-only. Preserved across load→save.</summary>
|
||||
public bool? Writable { get; set; }
|
||||
|
||||
private JsonObject _bag = new();
|
||||
|
||||
/// <summary>Loads a model from a TagConfig JSON string, defaulting any absent field and retaining
|
||||
@@ -30,6 +34,7 @@ public sealed class TwinCATTagConfigModel
|
||||
DeviceHostAddress = TagConfigJson.GetString(o, "deviceHostAddress") ?? "",
|
||||
SymbolPath = TagConfigJson.GetString(o, "symbolPath") ?? "",
|
||||
DataType = TagConfigJson.GetEnum(o, "dataType", TwinCATDataType.DInt),
|
||||
Writable = TagConfigJson.GetBoolNullable(o, "writable"),
|
||||
_bag = o,
|
||||
};
|
||||
}
|
||||
@@ -42,6 +47,7 @@ public sealed class TwinCATTagConfigModel
|
||||
TagConfigJson.Set(_bag, "deviceHostAddress", string.IsNullOrWhiteSpace(DeviceHostAddress) ? null : DeviceHostAddress.Trim());
|
||||
TagConfigJson.Set(_bag, "symbolPath", SymbolPath.Trim());
|
||||
TagConfigJson.Set(_bag, "dataType", DataType);
|
||||
TagConfigJson.Set(_bag, "writable", Writable);
|
||||
return TagConfigJson.Serialize(_bag);
|
||||
}
|
||||
|
||||
|
||||
@@ -25,31 +25,37 @@ public sealed class AdminOperationsActor : ReceiveActor
|
||||
private readonly IDbContextFactory<OtOpcUaConfigDbContext> _dbFactory;
|
||||
private readonly IActorRef _coordinator;
|
||||
private readonly IReadOnlyDictionary<string, IDriverProbe> _probesByType;
|
||||
private readonly TagConfigValidationMode _tagConfigValidationMode;
|
||||
private readonly ILoggingAdapter _log = Context.GetLogger();
|
||||
|
||||
/// <summary>Creates actor props for the admin operations actor.</summary>
|
||||
/// <param name="dbFactory">Factory for creating config database contexts.</param>
|
||||
/// <param name="coordinator">Reference to the deployment coordinator actor.</param>
|
||||
/// <param name="probes">Driver probes registered in DI; keyed by DriverType (case-insensitive).</param>
|
||||
/// <param name="tagConfigValidationMode">Deploy-gate TagConfig strictness mode (Warn default | Error opt-in).</param>
|
||||
/// <returns>Props configured to create an AdminOperationsActor.</returns>
|
||||
public static Props Props(
|
||||
IDbContextFactory<OtOpcUaConfigDbContext> dbFactory,
|
||||
IActorRef coordinator,
|
||||
IEnumerable<IDriverProbe> probes) =>
|
||||
Akka.Actor.Props.Create(() => new AdminOperationsActor(dbFactory, coordinator, probes));
|
||||
IEnumerable<IDriverProbe> probes,
|
||||
TagConfigValidationMode tagConfigValidationMode = TagConfigValidationMode.Warn) =>
|
||||
Akka.Actor.Props.Create(() => new AdminOperationsActor(dbFactory, coordinator, probes, tagConfigValidationMode));
|
||||
|
||||
/// <summary>Initializes a new instance of the AdminOperationsActor.</summary>
|
||||
/// <param name="dbFactory">Factory for creating config database contexts.</param>
|
||||
/// <param name="coordinator">Reference to the deployment coordinator actor.</param>
|
||||
/// <param name="probes">Driver probes registered in DI; keyed by DriverType (case-insensitive).</param>
|
||||
/// <param name="tagConfigValidationMode">Deploy-gate TagConfig strictness mode (Warn default | Error opt-in).</param>
|
||||
public AdminOperationsActor(
|
||||
IDbContextFactory<OtOpcUaConfigDbContext> dbFactory,
|
||||
IActorRef coordinator,
|
||||
IEnumerable<IDriverProbe> probes)
|
||||
IEnumerable<IDriverProbe> probes,
|
||||
TagConfigValidationMode tagConfigValidationMode = TagConfigValidationMode.Warn)
|
||||
{
|
||||
_dbFactory = dbFactory;
|
||||
_coordinator = coordinator;
|
||||
_probesByType = probes.ToDictionary(p => p.DriverType, StringComparer.OrdinalIgnoreCase);
|
||||
_tagConfigValidationMode = tagConfigValidationMode;
|
||||
|
||||
ReceiveAsync<StartDeployment>(HandleStartDeploymentAsync);
|
||||
ReceiveAsync<TestDriverConnect>(HandleTestDriverConnectAsync);
|
||||
@@ -202,6 +208,31 @@ public sealed class AdminOperationsActor : ReceiveActor
|
||||
errors.AddRange(DraftValidator.ValidateClusterTopology(cluster, nodes));
|
||||
}
|
||||
|
||||
// R2-11 (05/CONV-2): deploy-time TagConfig strictness inspection over equipment tags. The
|
||||
// driver-typed EquipmentTagConfigInspector surfaces present-but-invalid enum values (which the
|
||||
// lenient runtime silently defaults) + structurally-unparseable TagConfig. In Warn mode
|
||||
// (default) these are non-blocking (logged + appended to the accepted result Message); in Error
|
||||
// mode they fold into the reject list so a typo'd config cannot be re-deployed until fixed.
|
||||
// Running servers are untouched either way — the gate only sees re-deploys.
|
||||
var driverTypeById = draft.DriverInstances
|
||||
.GroupBy(d => d.DriverInstanceId, StringComparer.Ordinal)
|
||||
.ToDictionary(g => g.Key, g => g.First().DriverType, StringComparer.Ordinal);
|
||||
var tagConfigWarnings = new List<(string TagId, string Text)>();
|
||||
foreach (var t in draft.Tags.Where(t => t.EquipmentId is not null))
|
||||
{
|
||||
if (!driverTypeById.TryGetValue(t.DriverInstanceId, out var driverType)) continue;
|
||||
foreach (var w in EquipmentTagConfigInspector.Inspect(driverType, t.TagConfig))
|
||||
tagConfigWarnings.Add((t.TagId, $"tag '{t.TagId}' (equipment '{t.EquipmentId}'): {w}"));
|
||||
}
|
||||
if (tagConfigWarnings.Count > 0)
|
||||
{
|
||||
if (_tagConfigValidationMode == TagConfigValidationMode.Error)
|
||||
errors.AddRange(tagConfigWarnings.Select(x => new ValidationError("TagConfigInvalid", x.Text, x.TagId)));
|
||||
else
|
||||
foreach (var x in tagConfigWarnings)
|
||||
_log.Warning("StartDeployment: TagConfig warning (Warn mode, non-blocking): {Warning}", x.Text);
|
||||
}
|
||||
|
||||
if (errors.Count > 0)
|
||||
{
|
||||
var summary = string.Join("; ", errors.Select(e => $"[{e.Code}] {e.Message}"));
|
||||
@@ -277,11 +308,18 @@ public sealed class AdminOperationsActor : ReceiveActor
|
||||
|
||||
_coordinator.Tell(new DispatchDeployment(deploymentId, revHash, msg.CorrelationId));
|
||||
|
||||
// Accepted message = the compile-cost advisory (if any) + any Warn-mode TagConfig warnings, so
|
||||
// the operator sees the non-blocking strictness findings on a successful deploy.
|
||||
var messageParts = new List<string>();
|
||||
if (advisory is not null) messageParts.Add(advisory);
|
||||
messageParts.AddRange(tagConfigWarnings.Select(x => x.Text));
|
||||
var acceptedMessage = messageParts.Count > 0 ? string.Join("; ", messageParts) : null;
|
||||
|
||||
replyTo.Tell(new StartDeploymentResult(
|
||||
StartDeploymentOutcome.Accepted,
|
||||
deploymentId,
|
||||
revHash,
|
||||
Message: advisory,
|
||||
Message: acceptedMessage,
|
||||
msg.CorrelationId));
|
||||
}
|
||||
catch (Exception ex)
|
||||
|
||||
+47
@@ -0,0 +1,47 @@
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.AbCip;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.S7;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.TwinCAT;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.ControlPlane.AdminOperations;
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time TagConfig inspection dispatched by <c>DriverType</c> (R2-11, 05/CONV-2). Mirrors the
|
||||
/// AdminUI <c>TagConfigValidator</c> shape: a case-insensitive map from the canonical driver-type string
|
||||
/// to that driver's lightweight <c>Contracts</c> parser <c>Inspect()</c>, returning human-readable
|
||||
/// warnings (present-but-invalid enum values that the lenient runtime silently defaults, plus
|
||||
/// structurally-unparseable TagConfig). Unmapped drivers (Galaxy, OpcUaClient) are skipped exactly as in
|
||||
/// the AdminUI validator. Never throws.
|
||||
/// </summary>
|
||||
public static class EquipmentTagConfigInspector
|
||||
{
|
||||
private static readonly IReadOnlyDictionary<string, Func<string, IReadOnlyList<string>>> Inspectors =
|
||||
new Dictionary<string, Func<string, IReadOnlyList<string>>>(StringComparer.OrdinalIgnoreCase)
|
||||
{
|
||||
["Modbus"] = ModbusEquipmentTagParser.Inspect,
|
||||
["S7"] = S7EquipmentTagParser.Inspect,
|
||||
["AbCip"] = AbCipEquipmentTagParser.Inspect,
|
||||
["AbLegacy"] = AbLegacyEquipmentTagParser.Inspect,
|
||||
["TwinCat"] = TwinCATEquipmentTagParser.Inspect,
|
||||
["Focas"] = FocasEquipmentTagParser.Inspect,
|
||||
};
|
||||
|
||||
/// <summary>Inspects a tag's <c>TagConfig</c> for the given driver type. Returns the driver's warnings,
|
||||
/// or an empty list when the driver type is unmapped (Galaxy/OpcUaClient) or the inputs are null.</summary>
|
||||
/// <param name="driverType">The bound driver's <c>DriverType</c> (canonical string, case-insensitive).</param>
|
||||
/// <param name="tagConfig">The equipment tag's <c>TagConfig</c> JSON.</param>
|
||||
/// <returns>The warnings; empty when the driver is unmapped or clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string? driverType, string? tagConfig)
|
||||
{
|
||||
if (string.IsNullOrEmpty(driverType) || tagConfig is null) return Array.Empty<string>();
|
||||
return Inspectors.TryGetValue(driverType, out var inspect) ? inspect(tagConfig) : Array.Empty<string>();
|
||||
}
|
||||
|
||||
/// <summary>Whether the given driver type has a mapped inspector (equipment-tag protocol drivers only).</summary>
|
||||
/// <param name="driverType">The bound driver's <c>DriverType</c>.</param>
|
||||
/// <returns><see langword="true"/> when an inspector is registered for the driver type.</returns>
|
||||
public static bool IsMapped(string? driverType) =>
|
||||
!string.IsNullOrEmpty(driverType) && Inspectors.ContainsKey(driverType);
|
||||
}
|
||||
@@ -0,0 +1,18 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.ControlPlane.AdminOperations;
|
||||
|
||||
/// <summary>
|
||||
/// How the deploy gate treats TagConfig strictness inspection results (R2-11, 05/CONV-2). Sourced from
|
||||
/// <c>Deployment:TagConfigValidationMode</c> in appsettings; defaults to <see cref="Warn"/> so existing
|
||||
/// deployments are never blocked by a previously-tolerated typo.
|
||||
/// </summary>
|
||||
public enum TagConfigValidationMode
|
||||
{
|
||||
/// <summary>Non-blocking: inspection warnings are logged and appended to the accepted
|
||||
/// <c>StartDeploymentResult.Message</c>, but the deploy still succeeds. The default.</summary>
|
||||
Warn,
|
||||
|
||||
/// <summary>Blocking: inspection warnings fold into the draft-gate reject list, so a config with a
|
||||
/// typo'd enum (or unparseable TagConfig) cannot be re-deployed until fixed. Opt-in per environment
|
||||
/// once the fleet deploys warning-clean.</summary>
|
||||
Error,
|
||||
}
|
||||
@@ -2,6 +2,7 @@ using Akka.Actor;
|
||||
using Akka.Cluster.Hosting;
|
||||
using Akka.Hosting;
|
||||
using Microsoft.EntityFrameworkCore;
|
||||
using Microsoft.Extensions.Configuration;
|
||||
using Microsoft.Extensions.DependencyInjection;
|
||||
using ZB.MOM.WW.OtOpcUa.Configuration;
|
||||
using ZB.MOM.WW.OtOpcUa.ControlPlane.AdminOperations;
|
||||
@@ -61,7 +62,12 @@ public static class ServiceCollectionExtensions
|
||||
var dbFactory = resolver.GetService<IDbContextFactory<OtOpcUaConfigDbContext>>();
|
||||
var coordinator = registry.Get<ConfigPublishCoordinatorKey>();
|
||||
var probes = resolver.GetService<IEnumerable<IDriverProbe>>() ?? Enumerable.Empty<IDriverProbe>();
|
||||
return AdminOperationsActor.Props(dbFactory, coordinator, probes);
|
||||
// R2-11 (05/CONV-2): deploy-gate TagConfig strictness mode from appsettings
|
||||
// (Deployment:TagConfigValidationMode = Warn default | Error opt-in).
|
||||
var mode = Enum.TryParse<TagConfigValidationMode>(
|
||||
resolver.GetService<IConfiguration>()?["Deployment:TagConfigValidationMode"],
|
||||
ignoreCase: true, out var m) ? m : TagConfigValidationMode.Warn;
|
||||
return AdminOperationsActor.Props(dbFactory, coordinator, probes, mode);
|
||||
},
|
||||
singletonOptions);
|
||||
|
||||
|
||||
@@ -26,6 +26,14 @@
|
||||
<!-- Roslyn-free; gives HandleStartDeploymentAsync PassthroughScript.TryMatch to exclude
|
||||
mirror scripts (which compile to ~nothing) from the deploy compile-cost advisory. -->
|
||||
<ProjectReference Include="..\..\Core\ZB.MOM.WW.OtOpcUa.Core.Scripting.Abstractions\ZB.MOM.WW.OtOpcUa.Core.Scripting.Abstractions.csproj"/>
|
||||
<!-- R2-11 (05/CONV-2): the driver-typed EquipmentTagConfigInspector dispatches to each driver's
|
||||
lightweight Contracts parser Inspect(), the same dependency-light consumption AdminUI does. -->
|
||||
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.Modbus.Contracts\ZB.MOM.WW.OtOpcUa.Driver.Modbus.Contracts.csproj"/>
|
||||
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.S7.Contracts\ZB.MOM.WW.OtOpcUa.Driver.S7.Contracts.csproj"/>
|
||||
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.AbCip.Contracts\ZB.MOM.WW.OtOpcUa.Driver.AbCip.Contracts.csproj"/>
|
||||
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Contracts\ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Contracts.csproj"/>
|
||||
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Contracts\ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Contracts.csproj"/>
|
||||
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Contracts\ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Contracts.csproj"/>
|
||||
</ItemGroup>
|
||||
|
||||
</Project>
|
||||
|
||||
@@ -43,5 +43,9 @@
|
||||
"DrainIntervalSeconds": 5,
|
||||
"Capacity": 1000000,
|
||||
"DeadLetterRetentionDays": 30
|
||||
},
|
||||
"Deployment": {
|
||||
"_comment": "R2-11 (05/CONV-2): deploy-gate TagConfig strictness. Warn (default) = non-blocking warnings logged + appended to the deployment result message; Error = a config with a typo'd enum or unparseable TagConfig is rejected at the draft gate. Running servers are untouched; the gate only sees re-deploys.",
|
||||
"TagConfigValidationMode": "Warn"
|
||||
}
|
||||
}
|
||||
|
||||
+49
@@ -0,0 +1,49 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Tests;
|
||||
|
||||
/// <summary>R2-11 (05/CONV-2) strictness surface for the AbLegacy equipment-tag parser: lenient runtime
|
||||
/// freeze, <c>Inspect</c> reports the typo, and the <c>writable</c> key is honoured (default true).</summary>
|
||||
public sealed class AbLegacyEquipmentTagParserStrictnessTests
|
||||
{
|
||||
[Fact]
|
||||
public void Freeze_typo_dataType_still_defaults_to_Int()
|
||||
{
|
||||
AbLegacyEquipmentTagParser.TryParse("{\"address\":\"N7:0\",\"dataType\":\"Intt\"}", out var def)
|
||||
.ShouldBeTrue();
|
||||
def.DataType.ShouldBe(AbLegacyDataType.Int);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Inspect_reports_typo_dataType()
|
||||
{
|
||||
var warnings = AbLegacyEquipmentTagParser.Inspect("{\"address\":\"N7:0\",\"dataType\":\"Intt\"}");
|
||||
warnings.ShouldHaveSingleItem();
|
||||
warnings[0].ShouldContain("Intt");
|
||||
warnings[0].ShouldContain("dataType");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Inspect_clean_config_has_no_warnings()
|
||||
{
|
||||
AbLegacyEquipmentTagParser.Inspect("{\"address\":\"N7:0\",\"dataType\":\"Int\"}").ShouldBeEmpty();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Writable_false_is_honoured()
|
||||
{
|
||||
AbLegacyEquipmentTagParser.TryParse("{\"address\":\"N7:0\",\"dataType\":\"Int\",\"writable\":false}", out var def)
|
||||
.ShouldBeTrue();
|
||||
def.Writable.ShouldBeFalse();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Writable_absent_defaults_to_true()
|
||||
{
|
||||
AbLegacyEquipmentTagParser.TryParse("{\"address\":\"N7:0\",\"dataType\":\"Int\"}", out var def)
|
||||
.ShouldBeTrue();
|
||||
def.Writable.ShouldBeTrue();
|
||||
}
|
||||
}
|
||||
+61
@@ -0,0 +1,61 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// R2-11 (05/UNDER-6): an equipment-tag reference whose address violates the device series'
|
||||
/// capability matrix must fail to RESOLVE (surfacing <c>BadNodeIdUnknown</c>) — the same pre-flight
|
||||
/// authored tags get at <c>InitializeAsync</c> — instead of reaching the wire and failing later with a
|
||||
/// wire error. A capability-valid equipment tag still resolves + reads.
|
||||
/// </summary>
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class FocasEquipmentTagCapabilityGateTests
|
||||
{
|
||||
private const string Host = "focas://10.0.0.5:8193";
|
||||
|
||||
private static FocasDriver NewDriver() => new(new FocasDriverOptions
|
||||
{
|
||||
// Series 16i: macro range 0..999 — MACRO:9500 is out of range.
|
||||
Devices = [new FocasDeviceOptions(Host, Series: FocasCncSeries.Sixteen_i)],
|
||||
Probe = new FocasProbeOptions { Enabled = false },
|
||||
}, "drv-1", new FakeFocasClientFactory());
|
||||
|
||||
private static string EquipTag(string address) =>
|
||||
$"{{\"address\":\"{address}\",\"dataType\":\"Int32\",\"deviceHostAddress\":\"{Host}\"}}";
|
||||
|
||||
[Fact]
|
||||
public async Task Capability_violating_equipment_tag_does_not_resolve()
|
||||
{
|
||||
var drv = NewDriver();
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var results = await drv.ReadAsync([EquipTag("MACRO:9500")], CancellationToken.None);
|
||||
|
||||
results.Single().StatusCode.ShouldBe(FocasStatusMapper.BadNodeIdUnknown);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Capability_valid_equipment_tag_resolves_and_reads()
|
||||
{
|
||||
var drv = NewDriver();
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var results = await drv.ReadAsync([EquipTag("MACRO:100")], CancellationToken.None);
|
||||
|
||||
results.Single().StatusCode.ShouldNotBe(FocasStatusMapper.BadNodeIdUnknown);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Equipment_tag_for_unknown_device_does_not_resolve()
|
||||
{
|
||||
var drv = NewDriver();
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var badDevice = "{\"address\":\"MACRO:100\",\"dataType\":\"Int32\",\"deviceHostAddress\":\"focas://10.9.9.9:8193\"}";
|
||||
var results = await drv.ReadAsync([badDevice], CancellationToken.None);
|
||||
|
||||
results.Single().StatusCode.ShouldBe(FocasStatusMapper.BadNodeIdUnknown);
|
||||
}
|
||||
}
|
||||
+57
@@ -0,0 +1,57 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// R2-11 (05/CONV-2 + 05/UNDER-1) strictness surface for the FOCAS equipment-tag parser: lenient
|
||||
/// runtime freeze on <c>dataType</c>, forced read-only (<c>Writable == false</c> regardless of any
|
||||
/// authored <c>writable:true</c>), and <c>Inspect</c> reporting the typo + the write-request.
|
||||
/// </summary>
|
||||
public sealed class FocasEquipmentTagParserStrictnessTests
|
||||
{
|
||||
[Fact]
|
||||
public void Freeze_typo_dataType_still_defaults_to_Int32()
|
||||
{
|
||||
FocasEquipmentTagParser.TryParse("{\"address\":\"D0100\",\"dataType\":\"Int322\"}", out var def)
|
||||
.ShouldBeTrue();
|
||||
def.DataType.ShouldBe(FocasDataType.Int32);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Writable_is_always_false_even_when_requested_true()
|
||||
{
|
||||
FocasEquipmentTagParser.TryParse("{\"address\":\"D0100\",\"dataType\":\"Int32\",\"writable\":true}", out var def)
|
||||
.ShouldBeTrue();
|
||||
def.Writable.ShouldBeFalse();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Writable_is_false_when_absent()
|
||||
{
|
||||
FocasEquipmentTagParser.TryParse("{\"address\":\"D0100\",\"dataType\":\"Int32\"}", out var def)
|
||||
.ShouldBeTrue();
|
||||
def.Writable.ShouldBeFalse();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Inspect_warns_on_writable_true_request()
|
||||
{
|
||||
var warnings = FocasEquipmentTagParser.Inspect("{\"address\":\"D0100\",\"dataType\":\"Int32\",\"writable\":true}");
|
||||
warnings.ShouldContain(w => w.Contains("read-only") && w.Contains("writable"));
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Inspect_reports_typo_dataType()
|
||||
{
|
||||
var warnings = FocasEquipmentTagParser.Inspect("{\"address\":\"D0100\",\"dataType\":\"Int322\"}");
|
||||
warnings.ShouldContain(w => w.Contains("Int322") && w.Contains("dataType"));
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Inspect_clean_read_only_config_has_no_warnings()
|
||||
{
|
||||
FocasEquipmentTagParser.Inspect("{\"address\":\"D0100\",\"dataType\":\"Int32\"}").ShouldBeEmpty();
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,56 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// R2-11 (05/CONV-2): the Modbus probe parses the SAME factory DTO shape the driver factory parses, so
|
||||
/// <c>timeoutMs</c> binds identically instead of being silently dropped (it never bound to the runtime
|
||||
/// <c>ModbusDriverOptions.Timeout</c> TimeSpan). The OpcUaClient probe/factory parse-parity rule.
|
||||
/// </summary>
|
||||
public sealed class ModbusDriverProbeParityTests
|
||||
{
|
||||
[Fact]
|
||||
public void Config_timeoutMs_binds_as_the_effective_probe_timeout()
|
||||
{
|
||||
var (target, error) = ModbusDriverProbe.TryParseProbeTarget(
|
||||
"{\"host\":\"10.0.0.5\",\"port\":502,\"unitId\":3,\"timeoutMs\":250}",
|
||||
fallbackTimeout: TimeSpan.FromSeconds(5));
|
||||
|
||||
error.ShouldBeNull();
|
||||
target.ShouldNotBeNull();
|
||||
target!.Value.Host.ShouldBe("10.0.0.5");
|
||||
target.Value.Port.ShouldBe(502);
|
||||
target.Value.UnitId.ShouldBe((byte)3);
|
||||
target.Value.Timeout.ShouldBe(TimeSpan.FromMilliseconds(250));
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Absent_timeoutMs_falls_back_to_the_caller_timeout()
|
||||
{
|
||||
var (target, _) = ModbusDriverProbe.TryParseProbeTarget(
|
||||
"{\"host\":\"10.0.0.5\",\"port\":502}", fallbackTimeout: TimeSpan.FromSeconds(5));
|
||||
|
||||
target!.Value.Timeout.ShouldBe(TimeSpan.FromSeconds(5));
|
||||
target.Value.UnitId.ShouldBe((byte)1); // DTO default
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Missing_host_is_an_error()
|
||||
{
|
||||
var (target, error) = ModbusDriverProbe.TryParseProbeTarget(
|
||||
"{\"port\":0}", fallbackTimeout: TimeSpan.FromSeconds(5));
|
||||
target.ShouldBeNull();
|
||||
error.ShouldNotBeNull();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Invalid_json_is_an_error()
|
||||
{
|
||||
var (target, error) = ModbusDriverProbe.TryParseProbeTarget(
|
||||
"not valid json {{", fallbackTimeout: TimeSpan.FromSeconds(5));
|
||||
target.ShouldBeNull();
|
||||
error.ShouldContain("invalid");
|
||||
}
|
||||
}
|
||||
+49
@@ -0,0 +1,49 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.TwinCAT;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Tests;
|
||||
|
||||
/// <summary>R2-11 (05/CONV-2) strictness surface for the TwinCAT equipment-tag parser: lenient runtime
|
||||
/// freeze, <c>Inspect</c> reports the typo, and the <c>writable</c> key is honoured (default true).</summary>
|
||||
public sealed class TwinCATEquipmentTagParserStrictnessTests
|
||||
{
|
||||
[Fact]
|
||||
public void Freeze_typo_dataType_still_defaults_to_DInt()
|
||||
{
|
||||
TwinCATEquipmentTagParser.TryParse("{\"symbolPath\":\"MAIN.x\",\"dataType\":\"DIntt\"}", out var def)
|
||||
.ShouldBeTrue();
|
||||
def.DataType.ShouldBe(TwinCATDataType.DInt);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Inspect_reports_typo_dataType()
|
||||
{
|
||||
var warnings = TwinCATEquipmentTagParser.Inspect("{\"symbolPath\":\"MAIN.x\",\"dataType\":\"DIntt\"}");
|
||||
warnings.ShouldHaveSingleItem();
|
||||
warnings[0].ShouldContain("DIntt");
|
||||
warnings[0].ShouldContain("dataType");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Inspect_clean_config_has_no_warnings()
|
||||
{
|
||||
TwinCATEquipmentTagParser.Inspect("{\"symbolPath\":\"MAIN.x\",\"dataType\":\"DInt\"}").ShouldBeEmpty();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Writable_false_is_honoured()
|
||||
{
|
||||
TwinCATEquipmentTagParser.TryParse("{\"symbolPath\":\"MAIN.x\",\"dataType\":\"DInt\",\"writable\":false}", out var def)
|
||||
.ShouldBeTrue();
|
||||
def.Writable.ShouldBeFalse();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Writable_absent_defaults_to_true()
|
||||
{
|
||||
TwinCATEquipmentTagParser.TryParse("{\"symbolPath\":\"MAIN.x\",\"dataType\":\"DInt\"}", out var def)
|
||||
.ShouldBeTrue();
|
||||
def.Writable.ShouldBeTrue();
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,88 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.AdminUI.Uns.TagEditors;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.AdminUI.Tests.Uns;
|
||||
|
||||
/// <summary>
|
||||
/// R2-11 (05/UNDER-6): the new optional <c>writable</c> key round-trips through the driver-typed tag
|
||||
/// config models — a value the editors' new checkbox authors. Absent stays absent (so existing configs
|
||||
/// are untouched); an explicit <c>false</c> round-trips; unknown keys are preserved.
|
||||
/// </summary>
|
||||
public sealed class TagConfigModelWritableTests
|
||||
{
|
||||
[Fact]
|
||||
public void Modbus_absent_writable_stays_omitted()
|
||||
{
|
||||
var m = ModbusTagConfigModel.FromJson("{\"region\":\"HoldingRegisters\",\"address\":1,\"dataType\":\"Int16\"}");
|
||||
m.Writable.ShouldBeNull();
|
||||
m.ToJson().ShouldNotContain("writable");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Modbus_explicit_false_round_trips()
|
||||
{
|
||||
var m = ModbusTagConfigModel.FromJson("{\"address\":1,\"writable\":false}");
|
||||
m.Writable.ShouldBe(false);
|
||||
var json = ModbusTagConfigModel.FromJson(m.ToJson());
|
||||
json.Writable.ShouldBe(false);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Modbus_setting_writable_true_writes_the_key()
|
||||
{
|
||||
var m = ModbusTagConfigModel.FromJson("{\"address\":1}");
|
||||
m.Writable = true;
|
||||
ModbusTagConfigModel.FromJson(m.ToJson()).Writable.ShouldBe(true);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Writable_preserves_unknown_keys()
|
||||
{
|
||||
var m = ModbusTagConfigModel.FromJson("{\"address\":1,\"writable\":false,\"foo\":\"bar\"}");
|
||||
m.ToJson().ShouldContain("foo");
|
||||
m.ToJson().ShouldContain("bar");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void S7_writable_round_trips()
|
||||
{
|
||||
var m = S7TagConfigModel.FromJson("{\"address\":\"DB1.DBW0\",\"writable\":false}");
|
||||
m.Writable.ShouldBe(false);
|
||||
S7TagConfigModel.FromJson(m.ToJson()).Writable.ShouldBe(false);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void AbCip_writable_round_trips()
|
||||
{
|
||||
var m = AbCipTagConfigModel.FromJson("{\"tagPath\":\"Motor.Speed\",\"writable\":false}");
|
||||
m.Writable.ShouldBe(false);
|
||||
AbCipTagConfigModel.FromJson(m.ToJson()).Writable.ShouldBe(false);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void AbLegacy_writable_round_trips()
|
||||
{
|
||||
var m = AbLegacyTagConfigModel.FromJson("{\"address\":\"N7:0\",\"writable\":false}");
|
||||
m.Writable.ShouldBe(false);
|
||||
AbLegacyTagConfigModel.FromJson(m.ToJson()).Writable.ShouldBe(false);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void TwinCAT_writable_round_trips()
|
||||
{
|
||||
var m = TwinCATTagConfigModel.FromJson("{\"symbolPath\":\"MAIN.x\",\"writable\":false}");
|
||||
m.Writable.ShouldBe(false);
|
||||
TwinCATTagConfigModel.FromJson(m.ToJson()).Writable.ShouldBe(false);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Absent_writable_omitted_across_models()
|
||||
{
|
||||
ModbusTagConfigModel.FromJson("{\"address\":1}").ToJson().ShouldNotContain("writable");
|
||||
S7TagConfigModel.FromJson("{\"address\":\"DB1.DBW0\"}").ToJson().ShouldNotContain("writable");
|
||||
AbCipTagConfigModel.FromJson("{\"tagPath\":\"M.S\"}").ToJson().ShouldNotContain("writable");
|
||||
AbLegacyTagConfigModel.FromJson("{\"address\":\"N7:0\"}").ToJson().ShouldNotContain("writable");
|
||||
TwinCATTagConfigModel.FromJson("{\"symbolPath\":\"MAIN.x\"}").ToJson().ShouldNotContain("writable");
|
||||
}
|
||||
}
|
||||
+131
@@ -0,0 +1,131 @@
|
||||
using Akka.Actor;
|
||||
using Microsoft.EntityFrameworkCore;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Commons.Messages.Admin;
|
||||
using ZB.MOM.WW.OtOpcUa.Commons.Messages.Deploy;
|
||||
using ZB.MOM.WW.OtOpcUa.Commons.Types;
|
||||
using ZB.MOM.WW.OtOpcUa.Configuration;
|
||||
using ZB.MOM.WW.OtOpcUa.Configuration.Entities;
|
||||
using ZB.MOM.WW.OtOpcUa.Configuration.Enums;
|
||||
using ZB.MOM.WW.OtOpcUa.Configuration.Validation;
|
||||
using ZB.MOM.WW.OtOpcUa.ControlPlane.AdminOperations;
|
||||
using ZB.MOM.WW.OtOpcUa.ControlPlane.Tests.Harness;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.ControlPlane.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// R2-11 (05/CONV-2) — the deploy gate's TagConfig strictness inspection, exercised THROUGH the actor
|
||||
/// (the F10b/PR#423 lesson: an inspector built but never called is inert). Warn mode (default) accepts
|
||||
/// the deploy with the warning surfaced in the result Message; Error mode rejects the same draft; a
|
||||
/// clean config and an unmapped (Galaxy) tag produce no TagConfig noise.
|
||||
/// </summary>
|
||||
public sealed class AdminOperationsActorTagConfigGateTests : ControlPlaneActorTestBase
|
||||
{
|
||||
private static void Seed(IDbContextFactory<OtOpcUaConfigDbContext> dbFactory, string driverType, string tagConfig,
|
||||
string tagName = "flow")
|
||||
{
|
||||
var uuid = Guid.NewGuid();
|
||||
var equipmentId = DraftValidator.DeriveEquipmentId(uuid);
|
||||
using var db = dbFactory.CreateDbContext();
|
||||
db.Namespaces.Add(new Namespace
|
||||
{
|
||||
NamespaceId = "ns-1", ClusterId = "", Kind = NamespaceKind.Equipment, NamespaceUri = "urn:eq",
|
||||
});
|
||||
db.DriverInstances.Add(new DriverInstance
|
||||
{
|
||||
DriverInstanceId = "d-1", ClusterId = "", NamespaceId = "ns-1",
|
||||
Name = "drv", DriverType = driverType, DriverConfig = "{}",
|
||||
});
|
||||
db.Equipment.Add(new Equipment
|
||||
{
|
||||
EquipmentUuid = uuid, EquipmentId = equipmentId, Name = "pump-01",
|
||||
DriverInstanceId = "d-1", UnsLineId = "line-a", MachineCode = "PUMP01",
|
||||
});
|
||||
db.Tags.Add(new Tag
|
||||
{
|
||||
TagId = "tag-1", DriverInstanceId = "d-1", EquipmentId = equipmentId,
|
||||
Name = tagName, DataType = "Int16", AccessLevel = TagAccessLevel.Read, TagConfig = tagConfig,
|
||||
});
|
||||
db.SaveChanges();
|
||||
}
|
||||
|
||||
private const string TypoModbus = "{\"region\":\"HoldingRegisters\",\"address\":1,\"dataType\":\"Intt16\"}";
|
||||
private const string CleanModbus = "{\"region\":\"HoldingRegisters\",\"address\":1,\"dataType\":\"Int16\"}";
|
||||
|
||||
[Fact]
|
||||
public void Warn_mode_accepts_and_surfaces_the_warning_in_the_message()
|
||||
{
|
||||
var dbFactory = NewInMemoryDbFactory();
|
||||
Seed(dbFactory, "Modbus", TypoModbus);
|
||||
var coordinator = CreateTestProbe("coord");
|
||||
var actor = Sys.ActorOf(AdminOperationsActor.Props(
|
||||
dbFactory, coordinator.Ref, Enumerable.Empty<IDriverProbe>(), TagConfigValidationMode.Warn));
|
||||
|
||||
actor.Tell(new StartDeployment("joe", CorrelationId.NewId()));
|
||||
|
||||
coordinator.ExpectMsg<DispatchDeployment>(TimeSpan.FromSeconds(3));
|
||||
var reply = ExpectMsg<StartDeploymentResult>(TimeSpan.FromSeconds(3));
|
||||
reply.Outcome.ShouldBe(StartDeploymentOutcome.Accepted);
|
||||
reply.Message.ShouldNotBeNull();
|
||||
reply.Message.ShouldContain("Intt16");
|
||||
reply.Message.ShouldContain("tag-1");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Error_mode_rejects_the_same_draft()
|
||||
{
|
||||
var dbFactory = NewInMemoryDbFactory();
|
||||
Seed(dbFactory, "Modbus", TypoModbus);
|
||||
var coordinator = CreateTestProbe("coord");
|
||||
var actor = Sys.ActorOf(AdminOperationsActor.Props(
|
||||
dbFactory, coordinator.Ref, Enumerable.Empty<IDriverProbe>(), TagConfigValidationMode.Error));
|
||||
|
||||
actor.Tell(new StartDeployment("joe", CorrelationId.NewId()));
|
||||
|
||||
coordinator.ExpectNoMsg(TimeSpan.FromMilliseconds(500));
|
||||
var reply = ExpectMsg<StartDeploymentResult>(TimeSpan.FromSeconds(3));
|
||||
reply.Outcome.ShouldBe(StartDeploymentOutcome.Rejected);
|
||||
reply.Message.ShouldNotBeNull();
|
||||
reply.Message.ShouldContain("TagConfigInvalid");
|
||||
reply.Message.ShouldContain("Intt16");
|
||||
|
||||
using var verify = dbFactory.CreateDbContext();
|
||||
verify.Deployments.Count().ShouldBe(0);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Clean_config_accepts_with_no_tagconfig_noise()
|
||||
{
|
||||
var dbFactory = NewInMemoryDbFactory();
|
||||
Seed(dbFactory, "Modbus", CleanModbus);
|
||||
var coordinator = CreateTestProbe("coord");
|
||||
var actor = Sys.ActorOf(AdminOperationsActor.Props(
|
||||
dbFactory, coordinator.Ref, Enumerable.Empty<IDriverProbe>(), TagConfigValidationMode.Warn));
|
||||
|
||||
actor.Tell(new StartDeployment("joe", CorrelationId.NewId()));
|
||||
|
||||
coordinator.ExpectMsg<DispatchDeployment>(TimeSpan.FromSeconds(3));
|
||||
var reply = ExpectMsg<StartDeploymentResult>(TimeSpan.FromSeconds(3));
|
||||
reply.Outcome.ShouldBe(StartDeploymentOutcome.Accepted);
|
||||
(reply.Message is null || !reply.Message.Contains("Intt16")).ShouldBeTrue();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Unmapped_galaxy_tag_is_skipped_even_in_error_mode()
|
||||
{
|
||||
var dbFactory = NewInMemoryDbFactory();
|
||||
// Galaxy tag carrying a FullName (passes the DraftValidator Galaxy rule); the inspector has no
|
||||
// Galaxy mapping, so it is skipped regardless of mode.
|
||||
Seed(dbFactory, "GalaxyMxGateway", "{\"FullName\":\"Obj.Attr\",\"dataType\":\"nonsense\"}");
|
||||
var coordinator = CreateTestProbe("coord");
|
||||
var actor = Sys.ActorOf(AdminOperationsActor.Props(
|
||||
dbFactory, coordinator.Ref, Enumerable.Empty<IDriverProbe>(), TagConfigValidationMode.Error));
|
||||
|
||||
actor.Tell(new StartDeployment("joe", CorrelationId.NewId()));
|
||||
|
||||
coordinator.ExpectMsg<DispatchDeployment>(TimeSpan.FromSeconds(3));
|
||||
ExpectMsg<StartDeploymentResult>(TimeSpan.FromSeconds(3)).Outcome.ShouldBe(StartDeploymentOutcome.Accepted);
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,62 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.ControlPlane.AdminOperations;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.ControlPlane.Tests;
|
||||
|
||||
/// <summary>R2-11 (05/CONV-2): the DriverType-dispatched deploy-time TagConfig inspector — known drivers
|
||||
/// route to their parser's Inspect; unmapped drivers (Galaxy/OpcUaClient) skip; keys are case-insensitive.</summary>
|
||||
public sealed class EquipmentTagConfigInspectorTests
|
||||
{
|
||||
[Fact]
|
||||
public void Modbus_typo_dispatches_to_one_warning()
|
||||
{
|
||||
var warnings = EquipmentTagConfigInspector.Inspect(
|
||||
"Modbus", "{\"region\":\"HoldingRegisters\",\"address\":1,\"dataType\":\"Intt16\"}");
|
||||
warnings.ShouldHaveSingleItem();
|
||||
warnings[0].ShouldContain("Intt16");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Clean_modbus_config_has_no_warnings()
|
||||
{
|
||||
EquipmentTagConfigInspector.Inspect(
|
||||
"Modbus", "{\"region\":\"HoldingRegisters\",\"address\":1,\"dataType\":\"Int16\"}")
|
||||
.ShouldBeEmpty();
|
||||
}
|
||||
|
||||
[Theory]
|
||||
[InlineData("GalaxyMxGateway")]
|
||||
[InlineData("OpcUaClient")]
|
||||
[InlineData("Unknown")]
|
||||
public void Unmapped_driver_types_are_skipped(string driverType)
|
||||
{
|
||||
EquipmentTagConfigInspector.Inspect(driverType, "{\"dataType\":\"whatever\"}").ShouldBeEmpty();
|
||||
EquipmentTagConfigInspector.IsMapped(driverType).ShouldBeFalse();
|
||||
}
|
||||
|
||||
[Theory]
|
||||
[InlineData("modbus")]
|
||||
[InlineData("FOCAS")]
|
||||
[InlineData("focas")]
|
||||
[InlineData("twincat")]
|
||||
public void Driver_type_matching_is_case_insensitive(string driverType)
|
||||
{
|
||||
EquipmentTagConfigInspector.IsMapped(driverType).ShouldBeTrue();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Focas_writable_true_dispatches_read_only_warning()
|
||||
{
|
||||
var warnings = EquipmentTagConfigInspector.Inspect(
|
||||
"Focas", "{\"address\":\"D0100\",\"dataType\":\"Int32\",\"writable\":true}");
|
||||
warnings.ShouldContain(w => w.Contains("read-only"));
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Null_inputs_are_safe()
|
||||
{
|
||||
EquipmentTagConfigInspector.Inspect(null, "{}").ShouldBeEmpty();
|
||||
EquipmentTagConfigInspector.Inspect("Modbus", null).ShouldBeEmpty();
|
||||
}
|
||||
}
|
||||
Reference in New Issue