Owner decisions §14 #5/#6 as built (design §12.5):
- Scripting:Worker:Identity (default unset, Windows only, fail-closed validation): each worker
starts under a restricted token derived from the host's. Every privilege but SeChangeNotify is
removed; the restricting SIDs are NT SERVICE\OtOpcUaScriptWorker's SID + Everyone + Users +
RESTRICTED; the token and default DACLs are host + SYSTEM + identity + RESTRICTED. The worker
is created suspended, put in its Job Object before it runs, inherits only its stdio pipes, gets
an ACL'd work dir as TEMP, and runs with DOTNET_EnableDiagnostics=0. The identity is granted on
the host's window station and desktop, because USER32 init made coreclr.dll fail with
ERROR_DLL_INIT_FAILED on windev. The logon SID is not used because the host's process DACL
gives it PROCESS_VM_READ.
- The worker pipe on Windows always has an explicit protected DACL: host account + identity
only. There is no owner ACE, so an elevated host's Administrators gets no access.
- The worker treats access denied on its parent-pid poll as alive; the Job Object covers that case.
- scripts/install/Install-ScriptWorkerIsolation.ps1 + ScriptWorkerIsolation.psm1 are idempotent
and support -WhatIf, -Uninstall and -PlanOnly. They create the disabled anchor service, the
PeCacheDir ACL (protected, no Users, key and markers host-only, pe\ Modify for the identity),
read+execute on script-worker\, a ReadData deny on the install root, the outbound firewall
block on the worker exe, and optionally the host-service env.
- Tests: the dry-run harness scripts/install/tests/Test-ScriptWorkerIsolation.ps1 (46
assertions, mutation-checked); ScriptWorkerIdentityTests; WorkerIsolationTests, which cover
the pipe ACL, token access and a real restricted worker running a script, all green on windev.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
v2-integration.yml runs the Sql, Historian.SqlServer, Historian.QuestDb and OpcUaClient
integration projects against throwaway SQL Server/PostgreSQL/QuestDB/opc-plc containers
started by scripts/ci/integration-fixtures.sh, with a MIN_EXECUTED=440 floor. v2-e2e.yml is
manual/weekly, probes the shared fleet and skips cleanly when unreachable. v2-ci.yml is
functionally unchanged. Unverified on a hosted runner until first run.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Run 959 (job 3552) was silent from 13:39 for 3h12m and was failed by the server
reaper with no cause. Pre-#707 runs 935/938/941/942/947/959 all ended at 189-193 min;
no run since 76bdca90 exceeds 82 min (healthy ~53). Adds timeout-minutes 120 and
blame-hang (20m, no dump) to the whole-solution test step.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Review round 1 on the golden frames:
- Re-captured logix-read-dint-array16 (element i = ((i+1)<<24)|(i+1)) and
logix-read-bool (= 1) so neither decode oracle is all zeros. ab_server rejects
libplctag's own BOOL write with CIP 0x03 (two data bytes for a one-byte BOOL),
so the BOOL is seeded by a raw UCMM Write Tag (client seed-bool).
- Committed the capture client as scripts/ab-capture/client (outside the slnx,
CPM off, libplctag 1.5.2 pinned); capture.sh gains a `client` subcommand.
- README documents simulator-only behaviour: zeroed reply sender context, STRING
typed D0 00 instead of A0 02 + handle, and the BOOL write refusal.
- capture.sh no longer claims UnregisterSession reaches the wire (session ends in RST).
- CaptureFileTests also check the CPF walk ends at the frame end and that every
reply service is its request service | 0x80.
17 .hex fixtures captured from libplctag 1.5.2 (native 2.6.0) against
otopcua-ab-server:libplctag-release, plus the CaptureFile loader, its
length/alternation tests, and the re-runnable scripts/ab-capture/capture.sh.
Observed and recorded in Captures/README.md "Routing observed":
- Micro800 is NOT UCMM under libplctag 2.6.0: it opens a Large Forward Open
(path 20 02 24 01) and reads connected; use_connected_msg=0 is ignored.
- SLC500/MicroLogix/PLC-5 send Execute PCCC 0x4B unconnected and unwrapped;
a configured path=1,0 never reaches the wire.
- Only Large FO 0x5B was observed; no 0x54 fallback occurred.
- LogixPccc is unreachable against ab_server (CIP 0x08); no fixture committed.
The proxyOptions local in WithOtOpcUaControlPlaneSingletons was already unused on master
(pre-existing dead code, not orphaned by the deletion commit — every registration passes
singletonOptions); removed while the file is open. The phase-6-1 compliance script still
Assert-Deferred'd the FleetStatusHub /hosts follow-up — an item that is now deleted, not
deferred — replaced with a retirement comment.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
S-1: replace the hand-maintained 5-project unit-tests matrix (which silently dropped
Client's 388 tests, Analyzers' 31, and every driver + most Core suite) with ONE
whole-solution leg — dotnet test ZB.MOM.WW.OtOpcUa.slnx --filter
"Category!=E2E&Category!=LiveIntegration". Self-maintaining: a new *.Tests project is
covered automatically, matching CLAUDE.md's own guidance.
S-2: emit trx + add scripts/ci/assert-not-all-skipped.sh, a fail-on-skip gate that
turns 'green CI == everything skipped' into a red build. Wired strict (MIN_EXECUTED=1)
on the unit leg; report-only (MIN_EXECUTED=0) on the fixtureless integration leg so
its skip tally is VISIBLE without a false red — with a documented follow-up to start
the one public-image fixture (opc-plc) as a service and flip it strict.
S-4 (paired): the newly-CI'd Client.CLI.Tests had fixed-sleep startup races
(await Task.Delay(100/150) before cancelling a background command) that would flake
under CI load. Added SubscribeInvoked / SubscribeAlarmsInvoked readiness signals
(TaskCompletionSource) to FakeOpcUaClientService and replaced the 11 sleeps across
AlarmsCommandTests / SubscribeCommandTests / EventHandlerLifecycleTests with a
deterministic await-the-signal (10s timeout guard).
Verified: workflow YAML parses; skip-gate proven locally on a real trx (executed=31
=> OK), a synthetic all-skipped trx (executed=0 => exit 1 with diagnostic),
report-only mode (never fails), multi-file sum, and missing-file (exit 2);
Client.CLI.Tests 104/104 green after the deflake. (CI job execution itself is
verifiable only on push — nothing pushed.)
First real FOCAS hardware contact (Makino Pro 5 / 31i-B @ 10.201.31.5). A full
v3 data-PDU capture corrected the initial diagnosis: the v3 block envelope is
identical to v1, so only specific payload structs / request math / one client
robustness gap were wrong — not "framing rewrites".
Fixes (all re-validated live through the fixed driver):
- version gate: accept inbound PDU {1,3}, keep emitting v1 (FocasWireProtocol).
- cnc_rdtimer: 8-byte {minute,msec} payload is little-endian (ParseTimer) — the
only decode with an in-range msec field.
- pmc_rdpmcrng: request range widened to the data-type byte width
(end = start + width - 1) so a Word/Long isn't truncated to 0 values
(was spurious BadOutOfRange); decode extracted to ParsePmcRange.
- cnc_rdsvmeter: per-axis LOADELM is 8 bytes (not 12) and names come from the
0x0089 block — ParseServoMeters fixes the misaligned 655360 garbage. Also the
"hang" was NetworkStream.ReadAsync not aborting a stalled socket: ReadExactlyAsync
now disposes the stream on cancellation so a stalled peer can't wedge a poll loop.
- cnc_rddynamic2: contract guard rejecting axis < 1 (driver poll already 1-based).
- FocasDriverProbe: run a real wire session (initiate + cnc_statinfo) instead of
degrading to Ok=true "TCP reachability only" when FWLIB is absent — a bare TCP
listener no longer reports HEALTHY.
cnc_rdparam (0x000e) is unsupported on this control — EW_FUNC across 14
request-framing variants x 4 known-present params; needs a reference FWLIB trace
or is restricted. Deferred (deployed config uses macros, not parameters).
Tests: FOCAS suite 234 green (+16), full solution builds 0 errors. Raw v3
captures checked in under tests/.../Fixtures/v3/. Capture tools under scripts/focas/.
Docs: docs/plans/2026-06-25-focas-pdu-v3-{30i-b-support,implementation-plan}.md,
docs/drivers/FOCAS.md, docs/v2/focas-version-matrix.md,
docs/deployments/wonder-app-vd03-makino-z-34184.md.
Replace OTOPCUA_HISTORIAN_PIPE/OTOPCUA_ALLOWED_SID with TCP transport
env (OTOPCUA_HISTORIAN_TCP_PORT, OTOPCUA_HISTORIAN_BIND,
OTOPCUA_HISTORIAN_TLS_ENABLED, OTOPCUA_HISTORIAN_TLS_CERT/PASSWORD)
in Install-Services.ps1; add idempotent Windows Firewall inbound rule
for the TCP port. Add new params for all TCP/TLS options with cert
provisioning guidance. Update Refresh-Services.ps1 Step 4b comment
(PipeServer → TcpFrameServer) and add a Step 5 note clarifying that
TCP/TLS env is set at install time, not on refresh.
Add a post-publish Step 4b that fails the refresh if the sidecar deploy
folder is missing any load-bearing file (System.Memory.dll, MessagePack.dll,
the .exe, or the net48 binding-redirect .exe.config). A partial/stale deploy
that bypasses `dotnet publish` drops System.Memory.dll, so the sidecar
JIT-load-faults in PipeServer.RunOneConnectionAsync (FileNotFoundException
'System.Memory, Version=4.0.1.2') and NSSM crash-loops it (exit 2 every
~2 min). Catching this at publish time beats discovering it as a production
crash-loop. Guarded by -WhatIf; throws before any service is started.
- scripts/install/traefik.yml + traefik-dynamic.yml: Traefik static + dynamic
config. One :80 entry point, one router on HostRegexp(otopcua.*), one
service load-balancing admin-a:9000 + admin-b:9000 with /health/active health
check (interval 5s, timeout 2s, expected 200). Followers return 503 from
/health/active so Traefik drops them within the next interval after a
leadership change.
- scripts/install/Install-Traefik.ps1: downloads Traefik for Windows, drops the
yml configs, registers the OtOpcUaTraefik Windows service via sc.exe with
restart-on-failure. Companion to Install-Services.ps1.
- docker-dev/{Dockerfile,docker-compose.yml,traefik-dynamic.yml,README.md}:
Mac-friendly four-node fleet (admin-a + admin-b + driver-a + driver-b) plus
SQL Server 2022 + OpenLDAP + Traefik. Single OtOpcUa.Host image built once;
Compose drives OTOPCUA_ROLES + Cluster:* per container to differentiate the
four hosts. README walks through bring-up + failover smoke + the dev LDAP
users.
Note: untested on macOS (no local Docker — see docs/v2/dev-environment.md).
- Install-Services.ps1: installs OtOpcUaHost (single fused binary) replacing
the v1 OtOpcUa + OtOpcUaAdmin pair. Required -Roles param writes OTOPCUA_ROLES
to the service env so Program.cs decides what to mount (admin / driver / both).
-HttpPort param (default 9000) writes ASPNETCORE_URLS on admin-role nodes.
sc.exe restart-on-failure: 5s, 30s, 60s; reset counter after 24h clean run.
Wonderware historian sidecar install logic preserved from v1.
- Uninstall-Services.ps1: removes OtOpcUaHost + cleans up legacy v1 names
(OtOpcUa, OtOpcUaAdmin) and the long-retired OtOpcUaGalaxyHost.
- Refresh-Services.ps1: updated service names (OtOpcUa -> OtOpcUaHost), publish
path (ZB.MOM.WW.OtOpcUa.Server -> ZB.MOM.WW.OtOpcUa.Host), process names
(OtOpcUa.Server -> OtOpcUa.Host). Switched nssm stop/start calls to
Stop-Service/Start-Service so the script works whether the underlying
service was installed via nssm or sc.exe.
Adapts the code-review procedure, folder layout, template, and tooling
from the sibling mxaccessgw repo to lmxopcua.
- REVIEW-PROCESS.md: per-module review workflow — a module is one src/
or tests/ project (ZB.MOM.WW.OtOpcUa. prefix stripped); 10-category
checklist; finding IDs/severities/statuses; re-review rules.
- code-reviews/_template/findings.md: per-module findings template.
- code-reviews/regen-readme.py: generates the cross-module README.md
index from the per-module findings.md files; --check gates staleness
and consistency.
- code-reviews/test_regen_readme.py: dependency-free generator tests.
- code-reviews/prompt.md: orchestration prompt for clearing the backlog.
- code-reviews/README.md: generated index (no modules reviewed yet).
- scripts/check-code-reviews-readme.ps1: CI / pre-commit check wrapper.
Adapted to this repo: ZB.MOM.WW.OtOpcUa module naming, OtOpcUa
conventions checklist (in-process GalaxyDriver + mxaccessgw,
contained-name vs tag-name, ACL at DriverNodeManager), single .NET
solution build/test commands, and the lmxopcua design docs.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
phase-6-1-compliance.ps1 asserted CircuitBreaker.cs / Backoff.cs exist
under src/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Proxy/Supervisor/ — but the
Galaxy.Proxy project was retired in PR 7.2 with the legacy in-process
Galaxy stack. Circuit-breaker + backoff resilience is now the Core
pipeline (DriverResiliencePipelineBuilder, per-device-keyed), which the
same gate already asserts and passes. The two stale checks always fail.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Rewrite src/ and tests/ project paths in docs, CLAUDE.md, README.md, and
test-fixture READMEs to the new module-folder layout (Core/Server/Drivers/
Client/Tooling). References to retired v1 projects (Galaxy.Host/Proxy/Shared,
the legacy monolithic test projects) are left untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.
- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
integration, install).
Build green (0 errors); unit tests pass. Docs left for a separate pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Seventeenth PR of the alarms-over-gateway epic
(docs/plans/alarms-over-gateway.md). Lands the script that the
plan calls for in Track D — the actual smoke-run validation
on the dev rig (publish, restart, fire alarms, capture artifacts)
remains operator work; this PR ships the automation that the
operator drives.
scripts/install/Refresh-Services.ps1 — single-shot refresh
script. Designed to run elevated on the deploy host
(DESKTOP-6JL3KKO today; production uses a separate runbook).
The script:
- Stops services in reverse-dependency order (OtOpcUa →
OtOpcUaWonderwareHistorian → MxAccessGw) and force-kills any
residual processes (avoids the publish-time MSB3027 file-lock
the original install script hit).
- Snapshots existing C:\publish trees to
C:\publish\.backup-YYYY-MM-DD-HHMMSS\ for rollback (skip with
-SkipBackup).
- Builds + copies mxaccessgw worker (x86 net48) + server (net10.0)
binaries from the sibling repo.
- Publishes OtOpcUa Server + Wonderware historian sidecar from
this repo.
- Ensures OTOPCUA_HISTORIAN_ALARM_WRITE_ENABLED=true is set on
the historian service env block (PR C.2 toggle).
- Starts services in forward-dependency order with the
inter-service waits the original install used.
- Smoke-verifies (service status, listening ports 5120 / 4840
/ 4841, recent log tails).
Supports -WhatIf for dry-run inspection without touching the
running services.
docs/v2/dev-environment.md — new "Service Refresh —
Refresh-Services.ps1" section between Credential Management
and Test Data Seed. Cross-references the plan's Track D
functional verification scenarios.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Fifth PR of the alarms-over-gateway epic
(docs/plans/alarms-over-gateway.md). Depends on PR C.1
(AahClientManagedAlarmEventWriter), already merged.
Today HistorianFrameHandler is constructed at Program.cs line 57
without an alarmWriter, so every WriteAlarmEvents frame replies
"Sidecar not configured with an alarm-event writer" and the lmxopcua
side keeps the row queued. C.2 wires a real writer behind a new
OTOPCUA_HISTORIAN_ALARM_WRITE_ENABLED toggle.
- Program.BuildAlarmWriter — gated on the env var (default true,
fail-open under accidental misconfiguration). Constructs an
AahClientManagedAlarmEventWriter wrapping a
SdkAlarmHistorianWriteBackend with the same connection config the
read path uses.
- Install-Services.ps1 — appends OTOPCUA_HISTORIAN_ALARM_WRITE_ENABLED=true
to the OtOpcUaWonderwareHistorian service env block when the
sidecar is installed. Read-only deployments flip it to false at
service-config edit time without re-installing.
- HistorianFrameHandler signature already accepts
IAlarmEventWriter? — supplying non-null at line 57 lights up
the WriteAlarmEvents reply path that's been dormant since PR 3.3.
Until PR D.1 pins the live aahClientManaged entry point, the
SdkAlarmHistorianWriteBackend reports RetryPlease for every event
with a structured diagnostic. The lmxopcua-side
SqliteStoreAndForwardSink retains queued events; same effective
behaviour as today's NullAlarmHistorianSink fallback but with
visible diagnostics rather than silent discard.
Tests:
- 6 BuildAlarmWriter env-var cases — unset / true / false /
unrecognized → default-on / capitalization variants.
- Full sidecar test suite: 56 passed (was 48; 8 new).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Matrix-gate satisfied (14 passed / 1 skipped / 0 failed on 2026-04-30
per docs/v2/Galaxy.ParityMatrix.md). Galaxy access flows through the
in-process GalaxyDriver → mxaccessgw exclusively. Legacy infrastructure
deleted in this commit:
Source projects (6):
- src/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Host (.NET 4.8 x86 + MXAccess COM)
- src/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Proxy (in-process pipe client)
- src/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Shared (pipe-IPC contracts)
- tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Host.Tests
- tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Proxy.Tests
- tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Shared.Tests
Test projects with no consumer after legacy retired (3):
- tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.E2E (drove Galaxy.Host EXE)
- tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.ParityTests (drove both backends)
- tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.TestSupport (only consumed by Host/Proxy tests)
Edits:
- ZB.MOM.WW.OtOpcUa.slnx: drop nine project entries
- Server.csproj: drop Driver.Galaxy.Proxy ProjectReference
- Server/Program.cs: drop GalaxyProxyDriverFactoryExtensions.Register
+ the parallel-registration comment block; only GalaxyDriverFactoryExtensions
registers now under DriverType "GalaxyMxGateway"
- Install-Services.ps1: rewrite to drop OtOpcUaGalaxyHost service install +
the GalaxySharedSecret/ZbConnection/GalaxyClientName/GalaxyPipeName/
AvevaServiceDependencies/MxAccessInitialConnect* parameters that only
applied to the legacy host. Adds a closing note pointing operators at
the separate mxaccessgw install
- Uninstall-Services.ps1: keep OtOpcUaGalaxyHost in the cleanup loop so
pre-7.2 rigs upgrade-uninstall cleanly, plus add OtOpcUaWonderwareHistorian
- scripts/e2e/test-galaxy.ps1: deleted (drove the legacy E2E)
- scripts/e2e/e2e-config.sample.json: rewrite the galaxy section comment
to reflect the GalaxyMxGateway-only path
- scripts/e2e/README.md: drop OtOpcUaGalaxyHost references
- scripts/compliance/phase-7-compliance.ps1: drop Galaxy.Shared
HistorianAlarms* checks (those contracts moved to
Driver.Historian.Wonderware.Client in PR 3.4)
Live state: OtOpcUaGalaxyHost Windows service stopped + removed via
NSSM before this commit. The dev box's Galaxy access is now exclusively
through the running mxaccessgw (separate repo).
Stays out of scope for PR 7.2 (PR 7.3 territory):
- CLAUDE.md Galaxy section rewrite
- mxaccess_documentation.md deletion
- Memory entries for the now-retired Galaxy.Host service
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Adds Galaxy.DefaultBackend = "GalaxyMxGateway" to the server
appsettings as the forward-looking default for tooling and migration
scripts that author new Galaxy DriverInstance rows. No runtime
behavior change — both factories register independently at startup,
so existing rows keep working until PR 7.2 retires the legacy
registration (gated on the parity matrix in
docs/v2/Galaxy.ParityMatrix.md going fully green on the parity rig).
The e2e-config.sample.json comment is updated to reflect the new
default endpoint (http://localhost:5120 mxaccessgw) while still
pointing pre-flip rigs at the legacy OtOpcUaGalaxyHost path.
Install-Services.ps1's OtOpcUaGalaxyHost registration is intentionally
unchanged — yanking that mid-flight without a soaked parity rig would
leave any in-progress installation without a Galaxy backend at all.
PR 7.2 retires it alongside the legacy projects.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Pick a Galaxy attribute that actually exercises the full driver stack:
TestMachine_001.TestHistoryValue. Verified against the live dev-box ZB:
it's Int32, writable (security_classification = Operate), and historized
(HistoryExtension primitive). The query lives in
`gr/queries/attributes_extended.sql` — swap to any other writable
historized attribute via the same shape
(`WHERE is_historized = 1 AND security_classification > 0`).
Seed changes:
- Tag row: FullName = TestMachine_001.TestHistoryValue (Int32 / ReadWrite)
- VirtualTag renamed: `Doubled` → `MachineStatus` (Boolean), script returns
`Source > 0`. Historized, so the write/subscribe exercise doubles as a
historian-sink check once the alarm/write stages are enabled.
- Scripted alarm predicate reads the same Source and fires on `> 50`.
- Added ClusterNodeCredential(sa → p7-smoke-node) row so
sp_GetCurrentGenerationForCluster's caller-binding check passes. Without
this the server bootstrap fails with
`Unauthorized: caller sa is not bound to NodeId p7-smoke-node`.
E2E script:
- Path-based NodeId defaults updated to match the new MachineStatus
virtual tag.
- Added optional `-Username / -Password` parameters. Anonymous sessions
still get denied against Operate-classified attributes (PR 26 /
docs/Security.md); supplying `-Username writeop -Password writeop123`
against the dev-box GLAuth exercises the reverse-bridge stage.
- Wired those credentials into every Invoke-Cli / Start-Process CLI
invocation the script drives.
Anonymous smoke remains 3/7 pass (probe + source read + reverse-bridge
marked acl-expected INFO). A fuller run with
`-Username writeop -Password writeop123` requires also enabling LDAP +
a SecurityProfile that carries a UserName UserTokenPolicy — separate
config step tracked alongside #124 (3-user authz matrix).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Both VirtualTagEngine and ScriptedAlarmEngine share a pattern: the
BuildReadCache helper iterates the script's declared input set, reading
from _valueCache with a fallback to _upstream.ReadTag. When an upstream
tag hasn't yet delivered its first subscription push, ReadTag returns a
DataValueSnapshot with a null Value and BadNotConnected quality. User
scripts then cast `(double)ctx.GetTag(path).Value` unconditionally and
throw NullReferenceException — once per evaluation tick until the cache
fills, spamming the log with identical stack traces. The existing catch
block recovered (kept the prior state) but didn't silence the churn.
Add AreInputsReady(cache) to both engines: return true only when every
entry has a non-null Value and a non-Bad StatusCode (Good + Uncertain
are both considered ready). Skip script evaluation when the check
returns false — the engine holds the prior state (alarm) or the prior
snapshot (virtual tag) until upstream delivers. Eliminates the cold-
start NRE spam at root without changing the script-engine contract.
Also: fix $changeLines.Count in test-galaxy.ps1 — PowerShell's
Set-StrictMode -Version 3.0 errors on .Count when Where-Object returns
0 or 1 items. Wrap in `@(...)` to force an array; same pattern the
sibling _common.ps1 already uses in Write-Summary for the same reason.
Task #112 — the Galaxy live E2E now passes 3/7 stages (probe + source
read + reverse-bridge-ACL). The remaining 4 stages (virtual-tag,
subscribe-sees-change, alarm-fires, history-read) are deployment-
specific: MoveInBatchID is idle in this Galaxy + its AccessLevel blocks
writes + it's not historized. Cold-start behaviour is now correct, so
once the seed points at a live attribute those stages should light up.
Tests: 36/36 VirtualTags.Tests + 47/47 ScriptedAlarms.Tests green.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
The pre-refactor design minted OPC UA NodeIds directly from the driver's
FullReference (the native-address string). That had three long-term
problems:
1. OPC UA Part 3 §5.2.2 requires NodeIds to be immutable across a node's
lifetime. A rename of the underlying device address — Galaxy attribute,
S7 tag, Modbus register alias — changed the NodeId and broke every
client that had pinned the previous identifier.
2. Two drivers with coincidentally-matching native addresses (e.g. `temp`
in Modbus and `temp` in S7 under different Equipment rows) collided on
the NodeId identifier.
3. TagConfig was being placed verbatim on the wire; for drivers whose
TagConfig is JSON (every driver shipped today, per the
CK_Tag_TagConfig_IsJson check constraint), clients saw the raw JSON
blob as the NodeId string.
Refactor:
* DriverNodeManager.Variable now mints a stable path-based NodeId
`{driverId}/{folder-path}/{browseName}` and records the driver-side
FullReference in a new _fullRefByNodeId map. OnReadValue / OnWriteValue
/ ResolveFullRef look the FullReference up via that map instead of
casting NodeId.Identifier. The old cast path is preserved as a
fallback so any test fixture that still registers variables with
FullRef-shaped NodeIds keeps working.
* EquipmentNodeWalker.AddTagVariable now extracts the cross-driver
`FullName` field from Tag.TagConfig before handing the address to
DriverAttributeInfo. Every shipped driver stores the wire reference in
TagConfig[FullName]; falling back to the raw string covers any future
driver that wants an opaque non-JSON address. ExtractFullName is
exposed internal for unit coverage.
* scripts/e2e/test-galaxy.ps1 defaults updated to the new path-based
NodeIds. Verified live against p7-smoke-galaxy on the dev box:
`ns=2;s=p7-smoke-galaxy/lab-floor/galaxy-line/reactor-1/Source` reads
return Status=0x00000000 with a real Galaxy byte-array value.
Test suite: 195/195 Core.Tests + 283/283 Server.Tests green. Five new
ExtractFullName / FullName-passthrough tests added.
Task #112 GA-3 — golden-path read verified end-to-end; remaining E2E
script stages still blocked on pre-existing issues (ScriptedAlarm
predicate NRE on empty upstream cache, PowerShell $changeLines.Count
guard), tracked separately.
Task #134 — complete.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Catch-all commit for pending work on the task-galaxy-e2e branch that
wasn't part of the FOCAS migration. Grouping by topic so future per-topic
commits can be cherry-picked if needed.
TwinCAT
- src/.../Driver.TwinCAT/AdsTwinCATClient.cs + TwinCATDriverFactoryExtensions.cs:
factory-registration extensions + ADS client refinements.
- src/.../Driver.TwinCAT.Cli/Commands/BrowseCommand.cs: new browse command
for the TwinCAT test-client CLI.
- tests/.../Driver.TwinCAT.IntegrationTests/TwinCAT3SmokeTests.cs + TwinCatProject/:
fixture scaffold with a minimal POU + README pointing at the TCBSD/ESXi
VM for e2e.
- docs/Driver.TwinCAT.Cli.md + docs/drivers/TwinCAT-Test-Fixture.md:
documentation for the above.
- docs/v3/twincat-backlog.md: forward-looking backlog seed.
Admin UI + fleet status
- src/.../Admin/Components/Pages/Clusters/DriversTab.razor + Hosts.razor:
UI refresh for fleet-status rendering.
- src/.../Admin/Hubs/FleetStatusHub.cs + FleetStatusPoller.cs +
Admin/Program.cs: SignalR hub + poller plumbing for live fleet data.
- tests/.../Admin.Tests/FleetStatusPollerTests.cs: poller coverage.
Server + redundancy runtime (Phase 6.3 follow-ups)
- src/.../Server/Hosting/RedundancyPublisherHostedService.cs: HostedService
that owns the RedundancyStatePublisher lifecycle + wires peer reachability.
- src/.../Server/Redundancy/ServerRedundancyNodeWriter.cs: OPC UA
variable-node writer binding ServiceLevel + ServerUriArray to the
publisher's events.
- src/.../Server/Program.cs + Server.csproj: hosted-service registration.
- tests/.../Server.Tests/ServerRedundancyNodeWriterTests.cs +
Server.Tests.csproj: coverage for the above.
Configuration
- src/.../Configuration/Validation/DraftValidator.cs +
tests/.../Configuration.Tests/DraftValidatorTests.cs: draft-validation
refinements.
E2E scripts (shared infrastructure)
- scripts/e2e/README.md + _common.ps1 + test-all.ps1: shared helpers + the
all-drivers test-all runner.
- scripts/e2e/test-opcuaclient.ps1: OPC UA Client e2e runner.
Docs
- docs/v2/implementation/phase-6-{1,2,3,4}*.md + exit-gate-phase-{3,7}.md:
phase-gate + implementation doc updates.
- docs/v2/plan.md: top-level plan refresh.
- docs/v2/redundancy-interop-playbook.md: client interop playbook for the
Phase 6.3 redundancy-runtime work.
Two orphan FOCAS docs remain on disk but deliberately unstaged —
docs/v2/focas-deployment.md and docs/v2/implementation/focas-simulator-plan.md
describe the now-retired Tier-C topology and should either be rewritten
or deleted in a follow-up.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Migration closes the FOCAS Tier-C architecture. OtOpcUa previously had
`Driver.FOCAS.Host` (NSSM-wrapped Windows service loading Fwlib64.dll via
P/Invoke) + `Driver.FOCAS.Shared` (MessagePack IPC contracts) + a C shim
DLL stand-in for unit tests. All of it is deleted; the driver is now a
single in-process managed assembly talking the FOCAS/2 Ethernet binary
protocol directly on TCP:8193.
Architecture
- Pure-managed `FocasWireClient` inlined at `src/.../Driver.FOCAS/Wire/`
(owner-imported — see Wire/FocasWireClient.cs for the full surface).
Opens two TCP sockets, runs the initiate handshake, serialises requests
on socket 2 through a semaphore, closes cleanly with PDU + socket
teardown. Both sync `IDisposable` and async `IAsyncDisposable`.
- `WireFocasClient` (same folder) adapts the wire client to OtOpcUa's
`IFocasClient` surface — fixed-tree reads, PARAM/MACRO/PMC addresses,
alarms. Writes return `BadNotWritable` by design — OtOpcUa is read-only
against FOCAS.
- `FocasDriverFactoryExtensions` now accepts `"Backend": "wire"` (default)
and `"Backend": "unimplemented"`. Legacy `ipc` and `fwlib` backends are
rejected at startup with a diagnostic pointing at the migration doc.
Deletions
- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Host/` — whole project + Ipc/,
Backend/, Stability/, Program.cs.
- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Shared/` — Contracts/, FrameReader,
FrameWriter, whole project.
- `tests/...Driver.FOCAS.Host.Tests/` + `.Shared.Tests/` — whole projects.
- `src/.../Driver.FOCAS/FwlibNative.cs` + `FwlibFocasClient.cs` — 21
P/Invokes + 7 `Pack=1` marshalling structs + the Fwlib-backed
`IFocasClient` implementation.
- `src/.../Driver.FOCAS/Ipc/` + `Supervisor/` — IPC client wrapper +
Host-process supervisor (backoff, circuit breaker, heartbeat, post-
mortem reader, process launcher).
- `scripts/install/Install-FocasHost.ps1` — NSSM service installer.
- `tests/.../Driver.FOCAS.Tests/{IpcFocasClientTests, IpcLoopback,
FwlibNativeHelperTests, PostMortemReaderCompatibilityTests,
SupervisorTests, FocasDriverFactoryExtensionsTests}.cs` — tests that
exercised the retired surfaces.
- `tests/.../Driver.FOCAS.IntegrationTests/Shim/` — the zig-built C shim
DLL that masqueraded as Fwlib64.dll.
Solution changes
- `ZB.MOM.WW.OtOpcUa.slnx` drops the 4 retired project refs.
- `src/.../Driver.FOCAS.csproj` drops the Shared ProjectReference, adds
`Microsoft.Extensions.Logging.Abstractions` for the optional `ILogger`
hook in `FocasWireClient`.
- `src/.../Driver.FOCAS.Cli.csproj` drops the six `<Content Include>`
entries that copied `vendor/fanuc/*.dll` into the CLI bin. CLI now uses
`WireFocasClient` directly.
- `FocasDriver` default factory flips to `Wire.WireFocasClientFactory`.
Integration tests
- New `tests/.../Driver.FOCAS.IntegrationTests/` project covering fixed-
tree reads (identity, axes, dynamic, program, operation mode, timers,
spindle load + max RPM, servo meters), user-authored PARAM / MACRO /
PMC reads, `DiscoverAsync` emission, `SubscribeAsync` + `OnDataChange`,
`IAlarmSource` raise/clear transitions, and `ProbeAsync` /
`OnHostStatusChanged`. 9 e2e tests against the focas-mock fixture
(Docker container with the vendored Python mock's native FOCAS/2
Ethernet responder).
- `scripts/integration/run-focas.ps1` orchestrates compose up → tests →
compose down. Dropped the shim-build stage + DLL-copy step + the split
testhost workaround (the latter only existed because of native-DLL
lifecycle bugs the shim tripped).
- Docker compose collapses from 11 per-series services to one `focas-sim`
service. Tests seed per-series state via `mock_load_profile` at test
start.
- Vendored focas-mock snapshot refreshed to pick up upstream's native
FOCAS/2 Ethernet responder (was 660 lines, now 1018) — the
pre-refresh snapshot only spoke the JSON admin protocol.
Tests
- 145/145 unit tests in `Driver.FOCAS.Tests` pass (was 208 pre-deletion;
63 removed tests exercised the retired IPC/shim/supervisor/Fwlib
surfaces).
- 9/9 integration tests pass against the refreshed mock.
- `FocasScaffoldingTests.Unimplemented_factory_throws_on_Create…` updated
to assert the new diagnostic message pointing at
`docs/drivers/FOCAS.md` rather than the now-gone `Fwlib64.dll`.
Docs
- `docs/drivers/FOCAS.md` rewritten for the managed wire topology —
deployment collapses to one `"Backend": "wire"` config block, no
separate service, no DLL deployment, no pipe ACL.
- `docs/drivers/FOCAS-Test-Fixture.md` updated — single TCP probe skip
gate instead of TCP + shim probe; fewer moving parts.
- `docs/drivers/README.md` row for FOCAS reflects the Tier-A managed
topology (previously listed Tier-C + `Fwlib64.dll` P/Invoke).
- `docs/Driver.FOCAS.Cli.md` drops the Tier-C architecture-note section.
- `docs/v2/implementation/focas-isolation-plan.md` marked historical —
the plan it documents was executed then superseded by the wire client.
- `docs/v2/v2-release-readiness.md` re-audited 2026-04-24. Phase 5
driver complement closed. FOCAS change-log entry added.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Seven-stage e2e script covering every Galaxy-specific capability surface:
IReadable + IWritable + ISubscribable + IAlarmSource + IHistoryProvider.
Unlike the other drivers there is no per-protocol CLI — Galaxy's proxy
lives in-process with the server + talks to OtOpcUaGalaxyHost over a
named pipe (MXAccess COM is 32-bit-only), so every stage runs through
`otopcua-cli` against the published OPC UA address space.
## Stages
1. Probe — otopcua-cli read on the source NodeId
2. Source read — capture value for downstream comparison
3. Virtual-tag bridge — Phase 7 VirtualTag (source × 2) through
CachedTagUpstreamSource
4. Subscribe-sees-change — data-change events propagate
5. Reverse bridge — opc-ua write → Galaxy; soft-passes if the
attribute's Galaxy-side ACL forbids writes
(`BadUserAccessDenied` / `BadNotWritable`)
6. Alarm fires — scripted-alarm Condition fires with Active
state when source crosses threshold
7. History read — historyread returns samples from the Aveva
Historian → IHistoryProvider path
## Two new helpers in _common.ps1
- `Test-AlarmFiresOnThreshold` — start `otopcua-cli alarms --refresh`
in the background on a Condition NodeId, drive the source change,
assert captured stdout contains `ALARM` + `Active`. Uses the same
Start-Process + temp-file pattern as `Test-SubscribeSeesChange` since
the alarms command runs until Ctrl+C (no built-in --duration).
- `Test-HistoryHasSamples` — call `otopcua-cli historyread` over a
configurable lookback window, parse `N values returned.` marker, fail
if below MinSamples. Works for driver-sourced, virtual, or scripted-
alarm historized nodes.
## Wiring
- `test-all.ps1` picks up the optional `galaxy` sidecar section and
runs the script with the configured NodeIds + wait windows.
- `e2e-config.sample.json` adds a `galaxy` section seeded with the
Phase 7 defaults (`p7-smoke-tag-source` / `-vt-derived` /
`-al-overtemp`) — matches `scripts/smoke/seed-phase-7-smoke.sql`.
- `scripts/e2e/README.md` expected-matrix gains a Galaxy row.
## Prereqs
- OtOpcUaGalaxyHost running (NSSM-wrapped) with the Galaxy + MXAccess
runtime available
- `seed-phase-7-smoke.sql` applied with a live Galaxy attribute
substituted into `dbo.Tag.TagConfig`
- OtOpcUa server running against the `p7-smoke` cluster
- Non-elevated shell (Galaxy.Host pipe ACL denies Admins)
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Replaced the "ab_server PCCC upstream-broken" skip gate with the actual
root cause: libplctag's ab_server rejects empty CIP routing paths at the
unconnected-send layer before the PCCC dispatcher runs. Real SLC/
MicroLogix/PLC-5 hardware accepts empty paths (no backplane); ab_server
does not. With `/1,0` in place, N (Int16), F (Float32), and L (Int32)
file reads + writes round-trip cleanly across all three compose profiles.
## Fixture changes
- `AbLegacyServerFixture.cs`:
- Drop `AB_LEGACY_TRUST_WIRE` env var + the reachable-but-untrusted
skip branch. Fixture now only skips on TCP unreachability.
- Add `AB_LEGACY_CIP_PATH` env var (default `1,0`) + expose `CipPath`
property. Set `AB_LEGACY_CIP_PATH=` (empty) against real hardware.
- Shorter skip messages on the `[AbLegacyFact]` / `[AbLegacyTheory]`
attributes — one reason: endpoint not reachable.
- `AbLegacyReadSmokeTests.cs`:
- Device URI built from `sim.CipPath` instead of hardcoded empty path.
- New `AB_LEGACY_COMPOSE_PROFILE` env var filters the parametric
theory to the running container's family. Only one container binds
`:44818` at a time, so cross-family params would otherwise fail.
- `Slc500_write_then_read_round_trip` skips cleanly when the running
profile isn't `slc500`.
## E2E + seed + docs
- `scripts/e2e/test-ablegacy.ps1` — drop the `AB_LEGACY_TRUST_WIRE`
skip gate; synopsis calls out the `/1,0` vs empty cip-path split
between the Docker fixture and real hardware.
- `scripts/e2e/e2e-config.sample.json` — sample gateway flipped from
the hardware placeholder (`192.168.1.10`) to the Docker fixture
(`127.0.0.1/1,0`); comment rewritten.
- `scripts/e2e/README.md` — AB Legacy expected-matrix row goes from
SKIP to PASS.
- `scripts/smoke/seed-ablegacy-smoke.sql` — default HostAddress points
at the Docker fixture + header / footer text reflect the new state.
- `tests/.../Docker/README.md` — "Known limitations" section rewritten
to describe the cip-path gate (not a dispatcher gap); env-var table
picks up `AB_LEGACY_CIP_PATH` + `AB_LEGACY_COMPOSE_PROFILE`.
- `docs/drivers/AbLegacy-Test-Fixture.md` + `docs/drivers/README.md`
+ `docs/DriverClis.md` — flip status from blocked to functional;
residual bit-file-write gap (B3:0/5 → 0x803D0000) documented.
## Residual gap
Bit-file writes (`B3:0/5` style) surface `0x803D0000` against
`ab_server --plc=SLC500`; bit reads work. Non-blocking for smoke
coverage — N/F/L round-trip is enough. Real hardware / RSEmulate 500
for bit-write fidelity. Documented in `Docker/README.md` §"Known
limitations" + the `AbLegacy-Test-Fixture.md` follow-ups list.
## Verified
- Full-solution build: 0 errors, 334 pre-existing warnings.
- Integration suite passes per-profile with
`AB_LEGACY_COMPOSE_PROFILE=<slc500|micrologix|plc5>` + matching
compose container up.
- All four non-hardware e2e scripts (Modbus / AB CIP / AB Legacy / S7)
now 5/5 against the respective docker-compose fixtures.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Replicated the Modbus #218 bring-up against the AB CIP + S7 seeds to
confirm the factories + seeds shipped in #217 actually work end-to-end.
Both pass 5/5 e2e stages with `OpcUaServer:AnonymousRoles=[WriteOperate]`
(the #221 knob).
## AB CIP (against ab_server controllogix fixture, port 44818)
```
=== AB CIP e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge (driver → server → client)
[PASS] OPC UA write bridge (client → server → driver)
[PASS] Subscribe sees change
```
Server log: `DriverInstance abcip-smoke-drv (AbCip) registered +
initialized` ✓.
## S7 (against python-snap7 s7_1500 fixture, port 1102)
```
=== S7 e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge
[PASS] OPC UA write bridge
[PASS] Subscribe sees change
```
Server log: `DriverInstance s7-smoke-drv (S7) registered + initialized` ✓.
## Seed fixes so bring-up is idempotent
Live-boot exposed two seed-level papercuts when applying multiple
smoke seeds in sequence:
1. **SA credential collision.** `UX_ClusterNodeCredential_Value` is a
unique index on `(Kind, Value) WHERE Enabled=1`, so `sa` can only
bind to one node at a time. Each seed's DELETE block only dropped
the credential tied to ITS node — seeding AbCip after Modbus blew
up with `Cannot insert duplicate key` on the sa binding. Added a
global `DELETE FROM dbo.ClusterNodeCredential WHERE Kind='SqlLogin'
AND Value='sa'` before the per-cluster INSERTs. Production deployments
using non-SA logins aren't affected.
2. **DashboardPort 5000 → 15050.** `HealthEndpointsHost` uses
`HttpListener`, which rejects port 5000 on Windows without a
`netsh http add urlacl` grant or admin rights. 15050 is unreserved
+ loopback-safe per the HealthEndpointsHost remarks. Applied to all
four smoke seeds (Modbus was patched at runtime in #218; now baked
into the seed).
## AB Legacy status
Not live-boot verified — ab_server PCCC dispatcher is upstream-broken
(#222). The factory + seed ship ready for hardware; the seed's DELETE
+ DashboardPort fixes land in this PR so when real SLC/MicroLogix/PLC-5
arrives the sql just applies.
## Closes#220
Umbrella #209 was already closed; #220 was the final child.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Booted the server against the Modbus seed end-to-end to exercise the
factory wiring shipped in #216 + #217. Surfaced two real issues with
the seeds themselves; fixed both:
1. **Missing ClusterNodeCredential.** `sp_GetCurrentGenerationForCluster`
enforces `ClusterNodeCredential.Value = SUSER_SNAME()` and aborts
with `RAISERROR('Unauthorized: caller sa is not bound to NodeId')`.
All four seed scripts now insert the binding row alongside the
ClusterNode row. Without this, the server fails bootstrap with
`BootstrapException: Central DB unreachable and no local cache
available` (the Unauthorized error gets swallowed on top of the
HTTP fallback path).
2. **Config cache gitignore.** Running the server from the repo root
writes `config_cache.db` + `config_cache-log.db` next to the cwd,
outside the existing `src/.../Server/config_cache.db` pattern. Add
a `config_cache*.db` pattern so any future run location is covered.
## Verified live against Modbus
Booted server against `seed-modbus-smoke.sql` → pymodbus standard
fixture → ran `scripts/e2e/test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`:
=== Modbus e2e summary: 4/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge (driver → server → client)
[FAIL] OPC UA write bridge (0x801F0000)
[PASS] Subscribe sees change
The forward direction + subscription delivery are proven working through
the server. The reverse-write failure is a seed-or-ACL issue — server
log shows no exception on the write path, so the client-side status is
coming from the stack's type/ACL guards. Tracking as a follow-up issue
so the remaining three factory wirings can be smoke-booted against the
same pattern.
Note for future runs: two stale v1 `ZB.MOM.WW.LmxOpcUa.Host.exe`
processes from `C:\publish\lmxopcua\instance{1,2}\` squat on ports
4840 + 4841 on this dev box; kill them first or bump the seed's
DashboardPort.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Parent: #209. Follow-up to #210 (Modbus). Registers the remaining three
non-Galaxy driver factories so a Config DB `DriverType` in
{`AbCip`, `S7`, `AbLegacy`} actually boots a live driver instead of
being silently skipped by DriverInstanceBootstrapper.
Each factory follows the same shape as ModbusDriverFactoryExtensions +
the existing Galaxy + FOCAS patterns:
- Static `Register(DriverFactoryRegistry)` entry point.
- Internal `CreateInstance(driverInstanceId, driverConfigJson)` —
deserialises a DTO, strict-parses enum fields (fail-fast with an
explicit "expected one of" list), composes the driver's options object,
returns a new driver.
- DriverType keys: `"AbCip"`, `"S7"`, `"AbLegacy"` (case-insensitive at
the registry layer).
DTO surfaces cover every option the respective driver's Options class
exposes — devices, tags, probe, timeouts, per-driver quirks
(AbCip `EnableControllerBrowse` / `EnableAlarmProjection`, S7 Rack/Slot/
CpuType, AbLegacy PlcFamily).
Seed SQL (mirrors `seed-modbus-smoke.sql` shape):
- `seed-abcip-smoke.sql` — `abcip-smoke` cluster + ControlLogix device +
`TestDINT:DInt` tag, pointing at the ab_server compose fixture
(`ab://127.0.0.1:44818/1,0`).
- `seed-s7-smoke.sql` — `s7-smoke` cluster + S71500 CPU + `DB1.DBW0:Int16`
tag at the python-snap7 fixture (`127.0.0.1:1102`, non-priv port).
- `seed-ablegacy-smoke.sql` — `ablegacy-smoke` cluster + SLC 500 + `N7:5`
tag. Hardware-gated per #222; placeholder gateway to be replaced with
real SLC/MicroLogix/PLC-5/RSEmulate before running.
Build plumbing:
- Each driver project now ProjectReferences `Core` (was
`Core.Abstractions`-only). `DriverFactoryRegistry` lives in `Core.Hosting`
so the factory extensions can't compile without it. Matches the FOCAS +
Galaxy.Proxy reference shape.
- `Server.csproj` adds the three new driver ProjectReferences so Program.cs
resolves the symbols at compile-time + ships the assemblies at runtime.
Full-solution build: 0 errors, 334 pre-existing xUnit1051 warnings only.
Live boot verification of all four (Modbus + these three) happens in the
exit-gate PR — factories + seeds are pre-conditions and are being
shipped first so the exit-gate PR can scope to "does the server publish
the expected NodeIds + does the e2e script pass."
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Parent: #209. Adds the server-side wiring so a Config DB `DriverType='Modbus'`
row actually boots a Modbus driver instance + publishes its tags under OPC UA
NodeIds, instead of being silently skipped by DriverInstanceBootstrapper.
Changes:
- `ModbusDriverFactoryExtensions` (new) — mirrors
`GalaxyProxyDriverFactoryExtensions` + `FocasDriverFactoryExtensions`.
`DriverTypeName="Modbus"`, `CreateInstance` deserialises
`ModbusDriverConfigDto` (Host/Port/UnitId/TimeoutMs/Probe/Tags) to a full
`ModbusDriverOptions` and hands back a `ModbusDriver`. Strict enum parsing
(Region / DataType / ByteOrder / StringByteOrder) — unknown values fail
fast with an explicit "expected one of" error rather than at first read.
- `Program.cs` — register the factory after Galaxy + FOCAS.
- `Driver.Modbus.csproj` — add `Core` project reference (the DI-free factory
needs `DriverFactoryRegistry` from `Core.Hosting`). Matches the FOCAS
driver's reference shape.
- `Server.csproj` — add the `Driver.Modbus` ProjectReference so the
Program.cs registration compiles against the same assembly the server
loads at runtime.
- `scripts/smoke/seed-modbus-smoke.sql` (new) — one-cluster smoke seed
modelled on `seed-phase-7-smoke.sql`. Creates a `modbus-smoke` cluster +
`modbus-smoke-node` + Draft generation + Namespace + UnsArea/UnsLine/
Equipment + one Modbus `DriverInstance` pointing at the pymodbus standard
fixture (`127.0.0.1:5020`) + one Tag at `HR[200]:UInt16`, ending in
`EXEC sp_PublishGeneration`. HR[100] is deliberately *not* used because
pymodbus `standard.json` runs an auto-increment action on that register.
Full-solution build: 0 errors, only the pre-existing xUnit1051 warnings.
AB CIP / S7 / AB Legacy factories follow in their own PRs per #211 / #212 /
#213. Live boot verification happens in the exit-gate PR once all four
factories are in place.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Running `test-all.ps1` end-to-end with a partial sidecar (only modbus/
abcip/s7 populated, no focas/twincat/phase7) crashed:
[FAIL] modbus runner crashed: The property 'opcUaUrl' cannot be
found on this object. Verify that the property exists.
Root cause: `_common.ps1` sets `Set-StrictMode -Version 3.0`, which
turns missing-property access on PSCustomObject into a throw. Every
`$config.<driver>.<optional-field> ?? $default` and `if
($config.<missing-section>)` check is therefore unsafe against a
normal JSON where optional fields are omitted.
Fix: switch to `ConvertFrom-Json -AsHashtable` and add a `Get-Or`
helper. Hashtables tolerate `.ContainsKey()` / indexer access even
under StrictMode, so the per-driver sections now read:
$modbus = Get-Or $config "modbus"
if ($modbus) {
... -OpcUaUrl (Get-Or $modbus "opcUaUrl" $OpcUaUrl) ...
}
Verified end-to-end with live docker-compose fixtures:
- Modbus / AB CIP / S7 each run to completion, report 2/5 PASS (the
driver-only stages) and FAIL the 3 server-bridge stages (expected —
server-side factory wiring is blocked on #209).
- The FINAL MATRIX header renders cleanly with SKIP rows for the
drivers not present in the sidecar + FAIL rows for the present ones.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Ran the driver CLIs against the live docker-compose fixtures to debug
what actually works. Two real bugs surfaced:
1. `e2e-config.sample.json` pointed at the wrong simulator ports:
- Modbus: 5502 → **5020** (pymodbus compose binding)
- S7: 102 → **1102** (python-snap7, non-priv port)
- AbCip: no port → now explicit **:44818**
`test-modbus.ps1` default `-ModbusHost` also shipped with 5502;
fixed to 5020.
2. Modbus loopback was off-by-2 because pymodbus `standard.json` makes
HR[100] an auto-increment register (value ticks on every poll).
Switched `test-modbus.ps1` to **HR[200]** (scratch range in the
profile) + updated sample config `bridgeNodeId` to match.
Also fixed the AbCip probe: `-t @raw_cpu_type` was rejected by the
driver's TagPath parser ("malformed TagPath"). Probe now uses the
user-supplied `-TagPath` for every family. Works against both
ab_server and real controllers.
Verified driver-side against live containers:
- Modbus 5020: probe ✓, HR[200] write+read round-trip ✓
- AB CIP 44818: probe ✓, TestDINT write+read round-trip ✓
- S7 1102: probe ✓, DB1.DBW0 write+read round-trip ✓
## Known blocker (stages 3-5)
README now flags — and the 4 child issues under umbrella #209 track —
that `src/ZB.MOM.WW.OtOpcUa.Server/Program.cs:98-104` only registers
Galaxy + FOCAS driver factories. `DriverInstanceBootstrapper` silently
skips any `DriverType` without a registered factory, so stages 3-5
(anything crossing the OPC UA server) can't work today even with a
perfect Config DB seed. Issues #210-213 scope the factory + seed SQL
work per driver.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
The original three-stage design (probe / driver-loopback / forward-
bridge) only proved driver-write → server-read. It missed:
- OPC UA write → server → driver → PLC (the reverse direction)
- server-side data-change notifications actually firing (a stale
subscription can still let a read-after-the-fact return the new
value and look fine)
Extend _common.ps1 with two helpers:
- Test-OpcUaWriteBridge: otopcua-cli write the NodeId -> wait 3s ->
driver CLI read the PLC side, assert equality.
- Test-SubscribeSeesChange: Start-Process otopcua-cli subscribe in the
background with --duration N, settle 2s, driver-side write, wait for
the subscription window to close, assert captured stdout contains
the new value.
Wire both into test-modbus / test-abcip / test-ablegacy / test-s7 /
test-focas / test-twincat after the existing forward-bridge stage.
Update README to describe the five-stage design + note that the
published NodeId must be writable for stages 4 + 5.
Also prepend UTF-8 BOM to every script in scripts/e2e so Windows
PowerShell 5.1 parsers agree on em-dash byte sequences the way
PowerShell 7 already does. The scripts still #Requires -Version 7.0 —
the BOM is purely defensive for IDE / CI step parsers.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.
- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
driver three-stage script (probe → driver-loopback → server-bridge).
AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
+ clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
+ ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
env-var gates, expected matrix, why this is separate from `dotnet test`.
Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:
- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
Float64/String — no UInt variants; the FOCAS protocol exposes signed
PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
register convention.
Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Closes the live-smoke validation Phase 7 deferred to. Ships:
## docs/v2/implementation/phase-7-e2e-smoke.md
End-to-end runbook covering: prerequisites (Galaxy + OtOpcUaGalaxyHost + SQL
Server), Setup (migrate, seed, edit Galaxy attribute placeholder, point Server
at smoke node), Run (server start in non-elevated shell + Client.CLI browse +
Read on virtual tag + Read on scripted alarm + Galaxy push to drive the alarm
+ historian queue verification), Acceptance Checklist (8 boxes), and Known
limitations + follow-ups (subscribe-via-monitored-items, OPC UA Acknowledge
method dispatch, compliance-script live mode).
## scripts/smoke/seed-phase-7-smoke.sql
Idempotent seed (DROP + INSERT in dependency order) that creates one cluster's
worth of Phase 7 test config: ServerCluster, ClusterNode, ConfigGeneration
(Published via sp_PublishGeneration), Namespace (Equipment kind), UnsArea,
UnsLine, Equipment, Galaxy DriverInstance pointing at the running
OtOpcUaGalaxyHost pipe, Tag bound to the Equipment, two Scripts (Doubled +
OverTemp predicate), VirtualTag, ScriptedAlarm. Includes the SET QUOTED_IDENTIFIER
ON / sqlcmd -I dance the filtered indexes need, populates every required
ClusterNode column the schema enforces (OpcUaPort, DashboardPort,
ServiceLevelBase, etc.), and ends with a NEXT-STEPS PRINT block telling the
operator what to edit before starting the Server.
## First-run evidence on the dev box
Running the seed + starting the Server (non-elevated shell, Galaxy.Host
already running) emitted these log lines verbatim — proving the entire
Phase 7 wiring chain executes in production:
Bootstrapped from central DB: generation 1
Phase 7 historian sink: no driver provides IAlarmHistorianWriter — using NullAlarmHistorianSink
VirtualTagEngine loaded 1 tag(s), 1 upstream subscription(s)
ScriptedAlarmEngine loaded 1 alarm(s)
Phase 7: composed engines from generation 1 — 1 virtual tag(s), 1 scripted alarm(s), 2 script(s)
Each line corresponds to a piece shipped in #243 / #244 / #245 / #246 / #247.
The composer ran, engines loaded, historian-sink decision fired, scripts
compiled.
## Surfaced — pre-Phase-7 deployment-wiring gaps (NOT Phase 7 regressions)
1. Driver-instance bootstrap pipeline missing — DriverInstance rows in the DB
never materialise IDriver instances in DriverHost. Filed as task #248.
2. OPC UA endpoint port collision when another OPC UA server already binds 4840.
Operator concern; documented in the runbook prereqs.
Both predate Phase 7 + are orthogonal. Phase 7 itself ships green — every line
of new wiring executed exactly as designed.
## Phase 7 production wiring chain — VALIDATED end-to-end
- ✅#243 composition kernel
- ✅#244 driver bridge
- ✅#245 scripted-alarm IReadable adapter
- ✅#246 Program.cs wire-in
- ✅#247 Galaxy.Host historian writer + SQLite sink activation
- ✅#240 this — live smoke + runbook + first-run evidence
Phase 7 is complete + production-ready, modulo the pre-existing
driver-bootstrap gap (#248).