Joseph Doherty
17faf76ea7 Auto: s7-b2 — block-read coalescing for contiguous DBs
Closes #293
2026-04-25 21:23:06 -04:00
Joseph Doherty
7ba783de77 Tasks #211 #212 #213 — AbCip / S7 / AbLegacy server-side factories + seed SQL
Parent: #209. Follow-up to #210 (Modbus). Registers the remaining three
non-Galaxy driver factories so a Config DB `DriverType` in
{`AbCip`, `S7`, `AbLegacy`} actually boots a live driver instead of
being silently skipped by DriverInstanceBootstrapper.

Each factory follows the same shape as ModbusDriverFactoryExtensions +
the existing Galaxy + FOCAS patterns:
 - Static `Register(DriverFactoryRegistry)` entry point.
 - Internal `CreateInstance(driverInstanceId, driverConfigJson)` —
   deserialises a DTO, strict-parses enum fields (fail-fast with an
   explicit "expected one of" list), composes the driver's options object,
   returns a new driver.
 - DriverType keys: `"AbCip"`, `"S7"`, `"AbLegacy"` (case-insensitive at
   the registry layer).

DTO surfaces cover every option the respective driver's Options class
exposes — devices, tags, probe, timeouts, per-driver quirks
(AbCip `EnableControllerBrowse` / `EnableAlarmProjection`, S7 Rack/Slot/
CpuType, AbLegacy PlcFamily).

Seed SQL (mirrors `seed-modbus-smoke.sql` shape):
 - `seed-abcip-smoke.sql` — `abcip-smoke` cluster + ControlLogix device +
   `TestDINT:DInt` tag, pointing at the ab_server compose fixture
   (`ab://127.0.0.1:44818/1,0`).
 - `seed-s7-smoke.sql` — `s7-smoke` cluster + S71500 CPU + `DB1.DBW0:Int16`
   tag at the python-snap7 fixture (`127.0.0.1:1102`, non-priv port).
 - `seed-ablegacy-smoke.sql` — `ablegacy-smoke` cluster + SLC 500 + `N7:5`
   tag. Hardware-gated per #222; placeholder gateway to be replaced with
   real SLC/MicroLogix/PLC-5/RSEmulate before running.

Build plumbing:
 - Each driver project now ProjectReferences `Core` (was
   `Core.Abstractions`-only). `DriverFactoryRegistry` lives in `Core.Hosting`
   so the factory extensions can't compile without it. Matches the FOCAS +
   Galaxy.Proxy reference shape.
 - `Server.csproj` adds the three new driver ProjectReferences so Program.cs
   resolves the symbols at compile-time + ships the assemblies at runtime.

Full-solution build: 0 errors, 334 pre-existing xUnit1051 warnings only.

Live boot verification of all four (Modbus + these three) happens in the
exit-gate PR — factories + seeds are pre-conditions and are being
shipped first so the exit-gate PR can scope to "does the server publish
the expected NodeIds + does the e2e script pass."

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 11:15:38 -04:00
Joseph Doherty
0575280a3b Phase 3 PR 62 -- Siemens S7 native driver project scaffold (S7comm via S7netplus). First non-Modbus in-process driver. Creates src/ZB.MOM.WW.OtOpcUa.Driver.S7 (.NET 10, x64 -- S7netplus is managed, no bitness constraint like MXAccess) + tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests + slnx entries. Depends on S7netplus 0.20.0 which is the latest version on NuGet resolvable in this cache (0.21.0 per driver-specs.md is not yet published; 0.20.0 covers the same Plc+CpuType+ReadAsync surface). S7DriverOptions captures the connection settings documented in driver-specs.md \u00A75: Host, Port (default 102 ISO-on-TCP), CpuType (default S71500 per most-common deployment), Rack=0, Slot=0 (S7-1200/1500 onboard PN convention; S7-300/400 operators must override to slot 2 or 3), Timeout=5s, Tags list + Probe settings with default MW0 probe address. S7TagDefinition uses S7.Net-style address strings (DB1.DBW0, M0.0, I0.0, QD4) with an S7DataType enum (Bool, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float32, Float64, String, DateTime -- the full type matrix from the spec); StringLength defaults to 254 (S7 STRING max). S7Driver implements the IDriver-only subset per the PR plan: InitializeAsync opens a managed Plc with the configured CpuType + Host + Rack + Slot, pins WriteTimeout / ReadTimeout on the underlying TcpClient, awaits Plc.OpenAsync with a linked CTS bounded by Options.Timeout so the ISO handshake itself respects the configured bound; health transitions Unknown -> Initializing -> Healthy on success or Unknown -> Initializing -> Faulted on handshake failure, with a best-effort Plc.Close() on the faulted path so retries don't leak the TcpClient. ShutdownAsync closes the Plc and flips health back to Unknown. DisposeAsync routes through ShutdownAsync + disposes the SemaphoreSlim. Internal Gate + Plc accessors are exposed to the test project (InternalsVisibleTo) so PRs 63-65 can stack read/write/subscribe on the same serialization semaphore per the S7netplus documented 'one Plc per PLC, SemaphoreSlim-serialized' pattern. ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe are all deliberately omitted from this PR -- they depend on the S7AddressParser (PR 63) and land sequenced in PRs 64-65. Unit tests (S7DriverScaffoldTests, 5 facts): default options target S7-1500 / port 102 / slot 0, default probe interval 5s, tag defaults to writable with StringLength 254, driver reports DriverType=S7 + Unknown health pre-init, Initialize against RFC-5737 reserved IP 192.0.2.1 with 250ms timeout transitions to Faulted and throws (tests the connect-failure path doesn't leave the driver in an ambiguous state). 5/5 pass. dotnet build ZB.MOM.WW.OtOpcUa.slnx: 0 errors. No regression in Modbus / Galaxy suites. PR 63 ships S7AddressParser next, PR 64 wires IReadable/IWritable over S7netplus, PR 65 adds discovery + polling-overlay subscribe + probe. 2026-04-19 00:03:09 -04:00