- Endpoint rewrite: the driver now connects to the configured host AND port (scheme
match, advertised path kept) instead of the server-advertised URL — fixes NAT/port-map
upstreams and lets an in-test proxy carry the session (SDK SelectEndpoint rule).
- TcpStallProxy + OpcUaClientDriverStallWireTests: the in-place blip (#670) is now
wire-tested on loopback — one Bad, frozen read stamp, same session, identical value
republished Good, a post-recovery change arrives, no source-time regression after
the SDK's late backlog flush.
- Defect found by that test, fixed: a change published right after a stall rode a
Publish response the SDK timed out and never republished, leaving the node Good on
the pre-change value indefinitely. New trailing reconcile read (Timeout +
KeepAliveInterval after recovery) publishes any Good value newer than the last
accepted one, through the replay guard's mark.
- IDriverConnectionLossSource (Core.Abstractions): opt-in definitive-loss signal.
DriverInstanceActor attaches in PreStart / detaches in PostStop and turns a raise
into a disconnect only while Connected. OpcUaClient raises once per session on
keep-alive BadSessionIdInvalid/BadSessionClosed/BadSessionNotActivated/
BadServerHalted (measured: the SDK never re-opens a halted channel) or a dropped
subscription; ambiguous codes stay with the #527 watchdog.
- Replay guard: one Information summary per recovery when the window closes
("dropped N late notifications across M refs"), with a timer so quiet
subscriptions log it too.
- ReconnectPeriod deleted (options, AdminUI form, docs, tests); stored configs that
carry reconnectPeriod still parse in the factory, probe and browser.
- Docs: OpcUaClient.md, DriverLifecycle.md, driver-specs.md, CLAUDE.md.
Nothing read the mapping table beyond the startup validator; v3 UNS projection is
explicit via UnsTagReference. Legacy keys in stored DriverConfig are ignored (pinned).
Reverts the docker-dev opc-plc seed workaround from fdee129f.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Part 1 — rewire the three DriverType dispatch maps from hand-authored string
literals to the canonical DriverTypeNames constants (single source of truth):
- TagConfigEditorMap, TagConfigValidator (AdminUI)
- EquipmentTagConfigInspector (ControlPlane)
This FIXES the live drift ("TwinCat"->TwinCAT, "Focas"->FOCAS). The maps are
OrdinalIgnoreCase so behavior is identical; the value is no future drift.
Calculation is not added to the inspector (no CalculationTagDefinitionFactory.Inspect).
Added TagConfigDriverTypeNameGuardTests pinning the maps to the constants.
Part 2 — retire the routed /clusters/{id}/drivers driver-authoring flow (/raw
Waves A-C now cover driver/device/tag authoring end-to-end):
- Deleted DriverTypePicker, DriverEditRouter, the 8 *DriverPage shells, and the
ClusterDrivers list page.
- Removed the "Drivers" tab from ClusterNav. Routes /clusters/{id}/drivers* now
simply do not exist -> clean 404.
- The Forms/DeviceForms bodies, shared driver sections, and address pickers used
by the /raw modals are untouched.
Part 3 — updated PageAuthorizationGuardTests census: removed the 10 deleted
ConfigEditor pages + ClusterDrivers, updated group-count comments (ConfigEditor
21->11, AuthenticatedRead 17->16). Removed the now-dead Clusters.Drivers usings
from the 4 *DriverPageFormSerializationTests + the guard test.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Extract the 8 typed driver pages into embeddable <Driver>DriverForm bodies
(channel/protocol config) and add per-driver <Driver>DeviceForm bodies
(connection endpoint -> Device.DeviceConfig, v3 endpoint split). New
DriverConfigModal + DeviceModal dispatch by DriverType (DriverTypeNames) for
the /raw tree; Test-connect inside DeviceModal builds the merged Driver+Device
config transiently via DriverDeviceConfigMerger. Routed pages now host the
form bodies and keep working. Round-trip + enum-serialization guard tests for
the Modbus driver form + Modbus device model; retargeted the existing
page-form serialization tests + the _jsonOpts converter guard to the forms.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
- S7DriverPage.FormModel now preserves Tags through Form ↔ Options
translation (was hard-coding Tags = [] on every save, silently
destroying any tag list that operators had configured).
- Add FormModel_RoundTrip tests for OpcUaClient and Historian
mirror classes — both were translating Options ↔ form-model
entirely untested.
- Surface S7 Tags in the round-trip test so this regression
can't reach merge again.