Commit Graph

15 Commits

Author SHA1 Message Date
Joseph Doherty 4620e542e8 fix(acl): require the live scripted-alarm owner to match the generation's deployed owner (#797)
Review of 3d1b86b4: OpcUaPublishActor installs a new authority generation
before applying its address space, and an apply that throws keeps the old one.
A scripted alarm moved from equipment A to B therefore stayed commandable with
A's grant under B's generation (briefly before the rebuild, or indefinitely
after a failed apply).

The generation now carries ScriptedAlarmOwners (ScriptedAlarmId -> EquipmentId,
decoded by ParseDataPlaneAuthority from the artifact's ScriptedAlarms rows, the
same rows the composition materialises from). AuthorizeScriptedCondition denies
unless the node manager's live binding names the same owner as the generation:
a moved alarm is denied under the old owner's, the new owner's and a Cluster
grant until the address space re-binds it; an alarm the generation no longer
deploys is denied. Install/apply order unchanged.

Tests: window (a) generation moved / binding stale => both owners and Cluster
denied, then rebuild under the new owner => new owner allowed, old denied;
window (b) apply failed after install => denied across clock and further
generations, then a successful rebuild restores the new owner only; undeployed
alarm denied; artifact decode of the owner map.
2026-11-10 21:42:03 -05:00
Joseph Doherty 3d1b86b451 fix(acl): authorize scripted alarm commands at their owning equipment's scope (#797)
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.

- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
  EquipmentId it was materialised under (only when it hangs under that folder);
  dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
  same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
  [uns, Area, Line, Equipment]) decoded from the artifact by the same
  AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
  generation per call (uncached) and evaluates at the owner path; unbound,
  replaced or unplaceable owners deny under every grant. No id-split or
  realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
  NodeIds and AlarmCommand.AlarmId are unchanged.

Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808
(folder ids + Server-object event visibility for narrow UNS grants).
2026-11-10 21:23:57 -05:00
Joseph Doherty dc9e777bff test: prove trusted channels PKI and scoped audit compatibility 2026-11-10 11:43:59 -05:00
Joseph Doherty aac7c88417 test: migrate SDK 2.0 wire contracts and pin baseline aggregate vectors 2026-11-10 10:44:23 -05:00
Joseph Doherty 7fafeb433c test(opcua): flag-OFF HistoryUpdate over the wire - Cluster HistoryUpdate grant allowed, WriteOperate alone denied
The rig's key roles are now settable; the test derives them with the
production ApiKeyInterimRoleMapper from the same grants it installs.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 14:31:01 -04:00
Joseph Doherty f02067d295 test: retry OPC UA host start on a port bind race (TOCTOU in AllocateFreePort)
The tests probe a free port (bind 0, release) and start the SDK server later; under a
highly parallel run another test can take the port in between and the SDK fails with
'Failed to establish tcp listener sockets for Ipv4 and IPv6.'. OpcUaHostStart.StartAsync
builds a fresh host + server on a fresh port per attempt (up to 5) when the failure is a
bind failure; all 45 start sites in OpcUaServer.Tests, OpcUaServer.IntegrationTests and
Runtime.Tests use it. Per-attempt GUID ApplicationUris are hoisted out of the host factory
because a changed URI against a reused PKI store fails with 'Cannot access private key'.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 22:30:55 -04:00
Joseph Doherty dcc8adcf48 test(opcuaclient): HistoryRead Raw/AtTime/Processed wire tests against in-process server (#622)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:52:59 -04:00
Joseph Doherty 49a470a080 fix(client): alarm filter selected ActiveState/Id as ONE QualifiedName — every event read inactive
EventFilter.AddSelectClause(type, "ActiveState/Id") does not split the string;
it selects a single QualifiedName named "ActiveState/Id", which no event carries.
AckedState/Id, ActiveState/Id and EnabledState/Id therefore always arrived null
and Client.CLI 'alarms' (and Client.UI) reported every alarm inactive and
unacknowledged while a direct Read said Active. Pre-existing since a2883b82;
server-side event delivery was correct (proven with two-element select clauses,
incl. after #629). Select them with explicit two-element browse paths.

Over-the-wire test drives OpcUaClientService.SubscribeAlarmsAsync against the
in-process server (native + scripted); ServerEventRig now also selects
ActiveState/Id, Severity and Retain.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:19:27 -04:00
Joseph Doherty d0052d9fed fix(opcua): Part 9 condition children get instance-scoped NodeIds (#629)
Create(assignNodeIds: true) asked CustomNodeManager2.New, whose default returns the
node's current id, so every condition child kept the type's ns=0 instance-declaration id
(or an SDK-generated ns=0 number): translate of a child path returned BadNoMatch and a
Read of a browsed child id was BadNodeIdUnknown or served from the TYPE (UnshelveTime 0
on a condition timed-shelved for a minute), bypassing the data-plane ACL.

OtOpcUaNodeManager.New now derives {conditionId}/{browsePath} in the condition's
namespace, so the ACL scope of a child is its condition's scope plus the path. The
ShelvingState methods adopt their original AlarmConditionType_ShelvingState_* id as
MethodDeclarationId so clients calling them by that id still resolve. Condition removal
and rebuild forget the whole PredefinedNodes subtree so a removed condition's children
stop answering.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:45:46 -04:00
Joseph Doherty 8d5e456ce1 refactor(opcua): node manager logs through injected ILogger, drop CS0618 suppressions (#621)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 07:19:47 -04:00
Joseph Doherty ca0f1e7735 Merge #597/#599: real UnshelveTime, commented re-ack reports, native ack refused off-Primary, /alerts ack-path test; surgically-added raw nodes announced, equipment-with-references removal keeps references severed; Backing* parity guard
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 07:12:59 -04:00
Joseph Doherty bd63810645 fix(alarms): native ack refused off-Primary, commented re-ack reported, real UnshelveTime (#597)
- Native-condition Acknowledge on a non-Primary node returns BadInvalidState (nothing
  routed/applied/reported) via NativeAlarmAckPrimaryGate, fed from
  IDriverPrimaryRoleSource by OtOpcUaServerHostedService.
- A re-ack carrying a comment reports one comment event (Acked/Confirmed unchanged).
- TimedShelve applies its requested duration and the scripted projection carries
  UnshelveAtUtc, so ShelvingState/UnshelveTime counts down instead of ~24.8 days.
- Native re-ack still routed to the driver (deliberate: documented retry path), pinned.
- AdminUI /alerts client ack/shelve path test; docs/AlarmTracking.md decisions incl.
  accepted SDK EventsMonitored residual (item 6).
- Also #599/03/S20: RemoveEquipmentSubtree severs inverse Organizes edges.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 07:12:29 -04:00
Joseph Doherty 2b8b5fbdb2 test(opcua-client): wire-level driver tests against the in-process server; retire scaffold headers (#622)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 07:07:55 -04:00
Joseph Doherty d66269a99b test(client): over-the-wire alarm method calls against the in-process server
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 01:49:32 -04:00
Joseph Doherty 167a48bffa fix(alarms,acl): one condition event per Part 9 method call; gate Server-object model-change/audit events (#587, #588)
#587 — a client Acknowledge/Confirm/AddComment/Shelve/Enable/Disable emitted no condition event: the SDK's
ReportStateChange is gated on AutoReportStateChanges (never set), and the engine re-projection found the node
already in the new state and was suppressed by the delta-gate. WireMethodTransitionReporting now wraps each
method's SDK handler and, on Good, reports exactly once via ReportConditionEvent, under Lock so the routed
re-projection cannot race in ahead of the SDK applying the state. Independent of the SDK's imprecise
AreEventsMonitored bookkeeping. The shelve methods' state is applied by the wrapper (the SDK never applies
it). Native conditions' Confirmed/Shelving are method-owned (NativeAlarmProjector's constants would re-report
every ack and undo every shelve). MaxTimeShelved set to int.MaxValue ms at materialise — Create() left it 0
and every TimedShelve failed BadShelvingTimeOutOfRange. Wrong "SDK auto-fires (E2)" comments fixed.

#588 — with ACL on, GeneralModelChange and AuditWriteUpdate events no longer go to Server.ReportEvent
(ungated to every i=2253 item): ReportToServerObject delivers them per item, a model change narrowed to the
Affected nodes the session may Browse (dropped when none), an audit write only with Read on its source plus
the SDK audit/encryption guard. Flag off: unchanged.

#586 review: materialise raises only the new condition's monitored unit (was a full O(N) reconcile per
condition ⇒ O(N²) deploys under Lock).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 00:54:08 -04:00