Joseph Doherty 69e0a622f3 fix(focas): scale positions from each cnc_rddynamic2 block; delete the fabricated cnc_getfigure
Every 0x0026 position block is self-describing: [i32 raw][u16 base][u16 exponent],
value = raw / base^exponent. The live 31i-B capture (ref-dynamic2-axis1.bin)
reports base 10 / exponent 4 on every block, so axis 1 is 280.1574 mm, not
2801574. The driver ignored the envelope and instead sent 'cnc_getfigure'
(0x00D3) -- a command that does not exist in the FOCAS wire protocol, served only
by the in-tree mock; the real control refuses it with rc=1, so on hardware every
position fell back to PositionDecimalPlaces (default 0) and published raw counts.

- ParsePositionBlock decodes the envelope into FocasPosition; the driver applies
  raw / base^exponent at publish. PositionDecimalPlaces is now only the fallback
  for a scale-less (4-byte) block.
- A block describing no position (0xFFFF vacant marker, base not 2/10, exponent
  > 18 -- raw / 10^400 would read as a Good 0.0) publishes BadNoData on that node
  alone; siblings are untouched.
- ReadPositionFiguresAsync / IFocasClient.GetPositionFiguresAsync and the
  per-axis figure cache are deleted.

Ported from the sister ignitionoee FOCAS driver v0.17.0 (+ Focas.Wire-014);
live axis-scoped captures live-dynamic2-axis{1,2}-0x0026.bin (Z-34184 X 0.0374,
Y 370.177) added as fixtures.
2026-10-07 14:03:08 -04:00
Joseph Doherty f5475868f7 fix(inspect): trim before the framing check; stop advisories swallowing the backstop (#556); pin the MQTT payloadFormat mode contract (#557 item 2)
#556 item 1 — leading whitespace defeated every Inspect's pre-filter. Seven
factories (Modbus/S7/AbCip/AbLegacy/TwinCAT/FOCAS/Mqtt) tested
`reference[0] != '{'`, so a padded blob returned EMPTY and a tag the driver
refuses deployed clean. The check now trims first, matching the idiom
Sql/Calculation/MTConnect/OpcUaClient already used. The raw reference is still
what is handed to the mapper — the driver reads the stored blob, not a trimmed
copy — so the gate keeps mirroring the runtime rather than becoming lenient.
Both directions are pinned: a padded blob the mapper accepts still draws
nothing, and one that is not object-framed AFTER trimming still draws nothing
(it is not an equipment-tag TagConfig at all).

Six of the seven mappers hand the blob to a whitespace-tolerant
JsonDocument.Parse, so their verdict is unchanged by padding. MQTT is the
exception: both its readers carry the same framing gate, so a padded blob is
genuinely refused — which is why the untrimmed pre-filter was a real defect
there and not a cosmetic mismatch.

#556 item 2 — FOCAS and MQTT appended advisories unconditionally and then gated
the catch-all rejection message on `warnings.Count == 0`, so an advisory (which
fires on ACCEPTED blobs too, and says nothing about a refusal) silently
swallowed the only message naming a refusal nothing else can. The two classes
now accumulate in SEPARATE lists and the backstop gates on the rejection count
alone — structural, not string matching. MQTT's swallow was reachable in
production (a padded blob its readers refuse while every describe branch finds
the parsed document well-formed); FOCAS's backstop is currently unreachable by
audit, so its guard is protective.

#557 item 2 — decided and pinned: KEEP the union verdict. Evidence:
FromSparkplugTagConfig hard-codes PayloadFormat=Json and never consults the key;
only MqttSubscriptionManager (the Plain ingest path) decodes by it; and
MqttTagConfigModel.ToJson deliberately omits the key entirely in Sparkplug mode
(#513). So a Sparkplug driver genuinely serves the tag and rejecting it would be
stricter than the runtime. The cost — served behaviour depends on the driver's
MqttMode, which no tag row records — is paid by an ADVISORY naming the key and
the mode dependency, not by changing the verdict, so both gates keep agreeing.
The same invalid value on a blob the union REFUSES stays a rejection; the class
is decided by the accept gate, never by the key.

Falsified: reverting Modbus's trim reddens the padded-rejection theory;
neutering MQTT's backstop guard to the pre-#556 shape reddens the
advisory-plus-unnameable-rejection test; disabling the #557 advisory reddens the
contract pin; and for FOCAS, removing a describe branch alone stays green (the
backstop covers it) while additionally neutering the guard goes red.
2026-08-10 03:07:18 -04:00
Joseph Doherty 05b424788f fix(tagconfig): close the four #551 residuals — accept-gate-first Inspect, three authoring rules, CSV/service gate, doc sweep
Gitea #551.

1. CSV import ran no driver-typed config gate. Its typed columns were always
   strictly parsed, but the free-form TagConfigJson column reached the database
   unread, so a CSV could author a tag the driver rejects — one that deploys
   green and reads BadNodeIdUnknown forever. RawTagCsvMapper.Parse now names the
   offending row in the staged review grid, and RawTreeService enforces the same
   gate on CreateTag/UpdateTag/ImportTags: a form cannot be the guarantee (the
   API and any future caller reach none of them, and this repo has no bUnit).
   A rejected import row is an ERROR — the batch inserts nothing and the row is
   named — never a skip.

   Note the brief's premise that manual entry rides ImportTagsAsync is wrong:
   RawManualTagEntryModal commits row-by-row via CreateTagAsync, which is why
   the gate had to land on all three write paths.

2/3. The seven pre-#549 Inspect methods ran a hand-list of DescribeInvalidEnum
   checks, so every rejection cause not on the list was invisible. They are now
   ACCEPT-GATE-FIRST (the MTConnect/Sql/OpcUaClient/Calculation shape): ask the
   driver's own reader for the verdict, then explain the refusal, with a
   catch-all so "the parse rejects but Inspect said nothing" is unreachable.
   That closes S7's absent dataType, AbCip members[], Modbus stringByteOrder and
   the type-dependent guards, plus causes the issue did not name (absent
   region/address/tagPath/symbolPath/topic, TwinCAT Structure, MQTT's Sparkplug
   tuple). FOCAS and MQTT keep advisories about ACCEPTED blobs, so they
   diagnose rather than return empty.

   Authoring half: ModbusTagConfigModel gains stringByteOrder;
   AbCipTagConfigModel asks the new AbCipTagDefinitionFactory.DescribeInvalidMember;
   S7TagConfigModel captures whether the SOURCE blob declared dataType and asks
   S7TagDefinitionFactory.DataTypeKey/DeclaresDataType. One authority per rule.

4. Doc sweep: the six factory Inspect summaries, EquipmentTagConfigInspector's
   class remarks and AdminOperationsActor's comment all claimed invalid enums are
   "silently defaulted by the lenient runtime" — false since R2-11 Phase C made
   the runtime reads strict. They describe rejections now.
2026-08-10 00:08:06 -04:00
Joseph Doherty b61fe38823 fix(focas): browse-committed fixed-tree tags are readable (Gitea #540)
Authoring FOCAS tags through /raw -> Browse device... produced tags the driver
could never read. Every committed tag read BadNodeIdUnknown forever, and the
failure was silent end to end: the AdminUI accepted it, the deploy gate sealed
green, and the driver reported Healthy with 0 errors while ignoring the tags.
Net effect: the whole fixed-tree surface could not be published through any v3
authoring path. Found cutting wonder-app-vd03 over to v3 against a real Makino
Pro 5 / Fanuc 30i, where 0 of 20 committed tags read while two hand-authored
MACRO: tags on the same device read Good.

A captured browse leaf's id IS its DriverAttributeInfo.FullName, and the fixed
tree emitted "{deviceHost}/{path}" there -- an internal cache key, not an
address. Both authoring paths wrote it verbatim into TagConfig.address, and
FocasAddress.TryParse accepts no such form, so the driver skipped the tags at
init.

Fixed at the emitter rather than by stripping the host at commit, which fixes
the browse-commit flow and the manual picker's tree-select together and leaves
one canonical address form:

- FocasAddress gains a fourth kind, FIXED:<path>, and moves to Contracts so the
  AdminUI and ControlPlane can parse without referencing the runtime driver
  (#526). A FIXED: read is served from the fixed-tree snapshot the poll loop
  already maintains -- no area read, no connection. Writes refuse: nothing in
  that tree is a writable location on the CNC.
- The address carries no device. A tag's device comes from its Device row, and
  a second routing channel for one fact is what created this defect.
- An authored FIXED: tag arms the fixed-tree poll loop by itself. Enabled
  defaults false and the browser force-enables it only for a browse, so the
  operator would otherwise browse, commit, deploy, and land on a driver whose
  loop never starts -- every tag Bad with a correct address.
- Fixed-tree values are now dated from the last answered poll and go
  BadCommunicationError once it is stale (8 cadences, floored at 30s). The poll
  loop swallows a failed tick by design, so a dead CNC would otherwise serve its
  last snapshot as Good indefinitely -- harmless while nothing could bind to the
  tree, not harmless now.

Guardrails, so this class cannot recur silently:

- FocasTagConfigModel.Validate() runs the real parser instead of a non-empty
  check, and FocasTagDefinitionFactory.Inspect() warns at the deploy gate, which
  covers CSV/API config that never touches the modal.
- The manual picker offered axis/spindle/program/status "parameter groups" --
  none of which is a FOCAS addressing space -- and its own default value,
  axis:5, was unusable. It now composes PMC / PARAM: / MACRO: through
  FocasAddress, so what it emits is parseable by construction.

Tests assert addresses ROUND-TRIP through the parser rather than matching an
expected string: the previous FocasAddressBuilderTests pinned "axis:5" exactly,
which is how a green suite coexisted with a picker nobody could use. Verified
red-first against the old emitter. FOCAS 308, AdminUI 1095, ControlPlane 169,
Core 581 -- all pass, 0 warnings.

The remaining half of #540 -- a driver reporting Healthy/0 errors while
skipping tags at init -- is fleet-wide (eight drivers do this) and is filed
separately rather than patched per-driver.
2026-08-05 17:32:18 -04:00
Joseph Doherty 8b2c3fa04c v3(focas): adopt Modbus RawTagEntry exemplar (multi-device)
- Rename FocasEquipmentTagParser -> FocasTagDefinitionFactory; TryParse ->
  FromTagConfig(tagConfig, rawPath, out def). Drop leading-{ heuristic + the
  deviceHostAddress blob key; def.Name = rawPath. Add inverse ToTagConfig.
  writable: absent -> read-only, explicit true honoured (note preserved).
- FocasDriverOptions.Tags -> RawTags (IReadOnlyList<RawTagEntry>).
- FocasDriver: _tagsByRawPath (Ordinal); byName-only resolver; build table from
  RawTags via FromTagConfig; multi-device routing threads RawTagEntry.DeviceName
  -> ResolveDeviceHost match against options.Devices -> def.DeviceHostAddress
  (TODO v3 WaveC: live host from Device row DeviceConfig). Tolerant per-tag
  skip+log (mapper/address/matrix miss -> BadNodeIdUnknown); unknown device
  fails init fast.
- Factory: bind List<RawTagEntry> RawTags; retire FocasTagDto/ParseDataType.
- CLI FocasCommandBase.BuildOptions -> RawTags via ToTagConfig + DeviceName.
- Tests: FocasRawTags helper; migrate Tags= -> RawTags=; rename parser tests to
  FromTagConfig; rewrite retired blob-ref tests (equipment-tag/capability-gate/
  resolve-host) onto authored RawPath. 272 driver + 52 CLI green.
2026-07-15 20:19:55 -04:00
Joseph Doherty e8db0a683f fix(drivers): flip runtime tag parsers to strict enum parsing (#457)
v2-ci / build (pull_request) Successful in 4m12s
v2-ci / unit-tests (pull_request) Failing after 10m15s
R2-11 Phase C. All six equipment-tag parsers (Modbus/S7/AbCip/AbLegacy/
TwinCAT/Focas) now read enum fields via the new TagConfigJson.TryReadEnumStrict:
absent -> fallback, valid -> parsed, present-but-invalid (typo) -> TryParse
returns false -> EquipmentTagRefResolver.TryResolve false -> driver surfaces
BadNodeIdUnknown, instead of the old lenient path that silently defaulted a
typo to a wrong-width Good.

Modbus flips all three enum fields (region/dataType/byteOrder); the other five
flip dataType. The deploy-time Deployment:TagConfigValidationMode=Error gate is
unchanged and remains the operator pre-flight.

Coverage:
- Six *EquipmentTagParserStrictnessTests inverted from Freeze_typo_* (lenient)
  to Typo_*_rejects_the_tag + Valid_*_still_parses.
- TagConfigJsonTests.TryReadEnumStrict_rejects_only_invalid matrix.
- Driver-level end-to-end proof:
  AbCipEquipmentTagTests.Driver_read_of_a_typod_dataType_ref_surfaces_BadNodeIdUnknown
  drives the real AbCipDriver.ReadAsync through resolve->status.

Golden parity corpus has no typo'd enums, so the flip is a no-op there.
Full solution builds clean; all six driver suites + core + parity + gate green.
2026-07-15 11:28:34 -04:00
Joseph Doherty e294416087 fix(driver-focas): equipment tags forced read-only until PMC writes exist; shared readers + Inspect (R2-11, 05/UNDER-1) 2026-07-13 11:01:55 -04:00
Joseph Doherty 07eec11d31 docs+test(r2-02): bulkhead doc sweep + parsed-knob-must-be-wired guard (01/U-6, OVERALL theme 1) 2026-07-13 10:15:32 -04:00
Joseph Doherty 9cad9ed0fc docs(xmldoc): fill missing XML docs + strip tracking-ID comments across src
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
2026-07-07 12:38:39 -04:00
Joseph Doherty ab57e53b92 fix(code-review): resolve Batch 2 open findings (AbCip, AbLegacy, Galaxy, FOCAS)
- Driver.AbCip.Contracts-001: parse 'writable' from TagConfig JSON (default true) instead of hardcoding
- Driver.AbCip.Contracts-002/-003: Dt type comment; drop dead [Display]/[Range] annotations
- Driver.AbCip.Contracts-004: dedicated AbCipEquipmentTagParser test class (+15)
- Driver.AbCip-017: document Tick severity Low-fallback on Bad severity read
- Driver.AbLegacy.Contracts-002/-003/-004: isArray-scalar remarks (+tests), MaxTagBytes/ForFamily docs
- Driver.Galaxy.Browser-003 + Driver.Galaxy.Contracts-003: extract ResolveApiKey -> GalaxySecretRef (dedup)
- Driver.Galaxy-019: cache buffered-interval only on Ok + ILogger warnings + ClassifyIntervalReply (+tests)
- Driver.FOCAS.Contracts-002: thread WriteIdempotent through DiscoverAsync (+test)
2026-06-20 22:43:36 -04:00
Joseph Doherty 97020d0527 review(Driver.FOCAS.Contracts): first review; keep Writable=true default (re-triaged)
First review at 7286d320. -001 re-triaged Won't-Fix: the 'FOCAS is read-only' premise was
WRONG (FOCAS supports PMC/data writes); flipping Writable default to false broke 6 consuming
write tests -> reverted to true, doc corrected. -003/-004 doc fixes resolved. -002
(WriteIdempotent not threaded, Driver.FOCAS) Open.
2026-06-19 12:22:53 -04:00
Joseph Doherty 4973075291 feat(focas): scale axis positions by 10^PositionDecimalPlaces (config-supplied) 2026-06-16 05:32:36 -04:00
Joseph Doherty 34a42486dc feat(focas): resolve equipment-tag refs (read + write) via EquipmentTagRefResolver 2026-06-13 11:24:45 -04:00
Joseph Doherty f2f6eeb74e feat(drivers): expose ProbeTimeoutSeconds on every driver Options class
Adds a uniform [Range(1, 60)] ProbeTimeoutSeconds property to all 9
driver Options classes (Modbus 5s, AbCip 5s, AbLegacy 5s, S7 5s,
TwinCAT 10s, FOCAS 10s, OpcUaClient 15s, Galaxy 30s, Historian 15s).
Powers the AdminUI Test Connect button (Phase 7 of the plan).
2026-05-28 09:21:50 -04:00
Joseph Doherty d892ab9e12 refactor(driver-focas): extract FocasDriverOptions to .Contracts
Move FocasDriverOptions (and companion option types), FocasCncSeries,
and the FocasDataType enum to a new Driver.FOCAS.Contracts sibling
project. FocasDataTypeExtensions (which uses DriverDataType from
Core.Abstractions) stays in the runtime driver as FocasDataTypeExtensions.cs.

Convert two doc-comment references:
  <see cref="FocasDriver.InitializeAsync"/> → <c>FocasDriver.InitializeAsync</c>
  <see cref="FocasAddress.TryParse"/> → <c>FocasAddress.TryParse</c>
per the approved decision — no compilable usings were present in the
moved files.

The runtime Driver.FOCAS project gains a ProjectReference to .Contracts;
the .slnx is updated accordingly.
2026-05-28 09:13:10 -04:00