c8edd65f3e24c844fedec3da1bd0cc1a90a2df02
10 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
c9640f5ced |
fix(galaxy): picker-form alarm ack waits for the feed snapshot instead of dialling bare tag.Attr (#904)
v2-ci / unit-tests (push) Has been cancelled
A picker-form native alarm (attributeRef tag.Attr) only learns the provider-qualified reference Galaxy!<Area>.tag.Attr from the alarm feed. After a host restart the condition can be restored from LocalDb before the feed's first snapshot reached the new driver, and an ack in that window dialled the bare tag.Attr, which the gateway's AcknowledgeAlarm refuses. The feed now exposes InitialSnapshotCompleted (set on snapshot_complete, after every snapshot entry has been raised). AcknowledgeAsync resolves the reference through ResolveAlarmAckReferenceAsync: when a picker-form tag has learned nothing yet and the feed is running, it waits for that snapshot (2 s, and the caller's token) and dials the reference the snapshot names, so the area always comes from the feed and a re-areaed object acks under its current area. No reference is guessed: if the snapshot does not name the alarm, or does not arrive in time, the authored reference is dialled as before and refused visibly. Chosen over the alternatives in the issue: a GR-browse area lookup can be stale against the runtime area and is not loaded for authored tags, and a gateway-side tag.Attr resolution needs a cross-repo deploy and would resolve from the same monitor cache the snapshot already carries. Tests: 5 driver cases + 1 feed case (fail with the call site / sentinel reverted), and a skip-gated live gate GalaxyPickerAckBeforeSnapshotLiveTests, run against windev's TEST Galaxy (TestMachine_015.TestAlarm003): an ack issued before the snapshot dials Galaxy!TestArea.TestMachine_015.TestAlarm003 and is confirmed; with the call site reverted it fails with the gateway's InvalidRequest refusal. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi |
||
|
|
b61f3e0560 |
fix(galaxy): AVEVA priority 1 is the most urgent: Galaxy alarm Severity follows AVEVA's priority bands, live and history alike (#887)
v2-ci / unit-tests (push) Has been cancelled
GalaxyAlarmPriority, the one table live Galaxy alarms (MxAccessSeverityMapper) and AVEVA A&E history (EventMapper, #886) map the AVEVA priority through, ranked a higher number as more severe. AVEVA ranks priority 1 as the most urgent, so a priority-1 alarm read 250 and a priority-999 system event 1000. It now uses AVEVA's default priority ranges, most urgent first: AVEVA priority AVEVA severity bucket OPC UA Severity 1-250 1 Critical Critical 1000 251-500 2 High High 750 501-750 3 Medium Medium 500 751-999 4 Low Low 250 (history only) 0 not an alarm - 1 Out-of-range priorities clamp (<= 0 Critical, > 999 Low). Evidence, vd03 Runtime.dbo.Events read-only: priority 1/100 alarms carry AVEVA severity 1, 400/500 severity 2, 600/700 severity 3, and every priority-999 System.* / User.* row severity 0 with IsAlarm 0. - Live and history now use the same number. GalaxyDriver passes the table's exact value as AlarmEventArgs.OpcUaSeverity. Before, it passed only the bucket, which NativeAlarmProjector re-mapped through its generic 200/500/700/900 ladder, so live and history disagreed even before the direction fix. - History: a row whose AVEVA severity is 0 (System.Start/Stop/Deploy, User.Write...) is not an alarm and reads Severity 1, below every alarm band. For alarms AVEVA's 1-4 severity is still never the value: the live feed carries only the priority, so it cannot use it, and history must agree. - Docs: docs/Historian.md gains "Galaxy alarm priority -> Severity (lmxopcua#887)"; docs/AlarmTracking.md updated. - Live re-run of the #801/#886 harness against vd03 HistorianGateway ea9f21c (read-only, network-only): 224 of 233 cases identical to the #886 run, the 9 others differ only in Severity (priority-700 alarm rows 750 -> 500, 19 system/user events 1000 -> 1). Record: aveva-history-801.md "#887 re-run", report aveva-gate-sdk2-887.json.gz. Client-visible: every OPC UA client that ranks or filters Galaxy alarms by Severity sees the order reversed (live and HistoryReadEvents). ScadaBridge has no code that depends on the old values; its own mixed severity directions are ScadaBridge#129. Tests updated because they pinned the inverted table: - Driver.Galaxy.Tests MxAccessSeverityMapperTests (rewritten: edges 1/250/251/ 500/501/750/751/999, 0/-100/int.MinValue/1000/int.MaxValue clamps, monotonic-decreasing sweep, equals GalaxyAlarmPriority for -2..1001) - Driver.Galaxy.Tests GatewayGalaxyAlarmFeedTests (750 and 600 -> Medium) - Driver.Historian.Gateway.Tests EventMapperTests (band table, priority 999 -> 250, 1 -> 1000; system events -> 1) - OpcUaServer.IntegrationTests GalaxyEquipmentEventHistoryWireTests (700 -> 500, 100 -> 1000, System.Stop -> 1; the fake now stores AVEVA's real 0-4 severity) New tests: - Runtime.Tests NativeAlarmRestatementEndToEndTests .Galaxy_live_condition_severity_is_the_AVEVA_priority_band (8 rows: the real feed -> real GalaxyDriver -> host -> projector; the same rows EventMapperTests pins on the history path) - EventMapperTests.Aveva_severity_zero_marks_an_event_that_is_not_an_alarm (5 rows, incl. the priority-999 alarm positive control) - GalaxyDriverAlarmSourceTests: OpcUaSeverity passes through Mutation check, 8 mutants, all killed: the pre-#887 inverted table; the driver dropping OpcUaSeverity; no not-an-alarm rule; each of the three band edges off by one; history ignoring priority; a missing AVEVA severity read as 0. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi |
||
|
|
4fdc3708f4 |
test(galaxy): presence waits survive a starved/loaded runner; absence asserted behind positive controls (#858)
Under heavy parallel load (14 concurrent test processes + 14 CPU burners, with DOTNET_ThreadPool_ForceMinWorkerThreads=1 as the reproducer) the Galaxy tests with 1-3 s fixed waits failed 16/70 runs. Every failure was a background loop started with Task.Run (alarm feed, DeployWatcher, EventPump, ReconnectSupervisor) not being SCHEDULED within the ceiling - e.g. DeployWatcher's stream had not even been opened after 2 s. No production race: the code under test was checked for each (alarm feed dispatch is synchronous in-order, DeployWatcher/ReconnectSupervisor state is lock- or loop-local, subscribe registers before returning). - New shared TestWait (UntilAsync / ForAsync / HealthyAsync): 30 s presence ceiling, failure reports elapsed ms + an observed-state snapshot (#856 shape; GalaxyDriverFixRound1Tests.WaitUntilAsync now delegates to it). - Converted the short waits in GatewayGalaxyAlarmFeedTests, DeployWatcherTests, GalaxyDriverSubscribeTests, GalaxyDriverRawPathKeyingTests (its WaitForAsync never threw on timeout), EventPumpStreamFaultTests, EventPumpReplayGapTests, ReconnectSupervisorTests; FixRound2 InitBudget 2 s -> 10 s (the parked fetch never completes, so any finite bound keeps the verdict). - Absence by short sleep replaced with positive controls: DeployWatcher bootstrap and same-deploy-time (follow with a real change, assert exactly that one raise - verified red when suppression is removed), subscribe failed-tag / unsubscribed handle (follow with a live handle's event), faulted pump (wait for its onStreamFault instead of 100 ms). - Fixed sleeps that raced scheduling: subscribe-once read tests wait for the read's registration (TrackedSubscriptionCountForTests) instead of 50 ms; supervisor Dispose test waits for reopen entry instead of 50 ms; the already-Healthy WaitForHealthy test asserts synchronous completion instead of a wall-clock bound. FakeSubscriber.Map is now a ConcurrentDictionary. Loaded run (14 parallel x 5, 14 burners, ForceMinWorkerThreads=1): before 16/70 failed runs; after 0/350 (70 + 210 + 70). Without the thread-pool override: 0/70 before and after on this host. Serial: 472 passed, 8 skipped. Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk |
||
|
|
b8202e1147 |
test: remaining xUnit1051/1031/1030, CS8602/8604, CS0618, CS0219, CS0649, NU1510 fixes (lmxopcua#725)
v2-ci / unit-tests (push) Has been cancelled
Awaited deadline oracles get the runner token; sync-over-async tests made async; nullable child models asserted via ShouldNotBeNull() return values; obsolete SDK ctors replaced with the telemetry overloads; dead locals/fixture and the redundant DI PackageReference removed. No suppressions. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV |
||
|
|
b39bb6794d |
fix(alarms): native-alarm re-statements no longer duplicate history or hide acked alarms (#656)
- AlarmTransitionKind.ActiveAcknowledged (appended): active AND acked applied as ONE projection. Galaxy ActiveAcked snapshot entries and OpcUaClient inactive->(active,acked) use it; the projector writes 'Activated' only if not already active, 'Acknowledged' only if not acked. - AlarmEventArgs.IsRestatement (optional, default false): set only by Galaxy snapshot entries and OpcUaClient first sight. A flagged Retrigger on an Active+unacked condition with the same message and severity, or a flagged Clear on an inactive condition, writes no /alerts row. - NativeAlarmProjector reports the history rows per transition; ForwardNativeAlarm writes one row per entry. Unflagged sources (FOCAS/MTConnect/AbCip, live Galaxy) are unchanged. - Tests: projector rules each with a must-write control; OpcUaClient transition table; Galaxy feed/driver mapping; Galaxy + OpcUaClient end-to-end through DriverHostActor. Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe |
||
|
|
89961af6e6 |
fix(alarms): #647 review — Raise on an active condition is a re-statement; FOCAS outage quality + health
MAJOR-1: a deploy that changes a driver's config respawns it, and the fresh instance's empty told record re-sent Raise for every still-active alarm, un-acking acknowledged conditions and writing a duplicate "Activated" alerts row. NativeAlarmProjector now treats Raise on an already-active condition as a re-statement (keeps Acked; ForwardNativeAlarm skips the alerts row); only Retrigger (or inactive->active) un-acks. Sources whose upstream ack state is authoritative send Retrigger for an unacked re-statement: OpcUaClient on first sight (no prior told), Galaxy for an unacked active snapshot entry. Runtime E2E drives a FRESH FOCAS driver after a redeploy and asserts the ack survives. MAJOR-2: a failed FOCAS alarm read annotates each subscribed condition BadNoCommunication once per outage (#626 quality-only path) with one Warning (MINOR-6), lifted to Good on recovery; failed alarm reads degrade driver health with LastSuccessfulRead frozen (successful ones advance it), so an alarm-only driver trips the #527 comms-loss watchdog. MINOR-3 CLAUDE.md #630 bullet; MINOR-4 split line; MINOR-5 a non-empty cnc_rdalmmsg2 payload that fits neither stride throws; MINOR-7 value-tag + parsed-address tables are built and swapped, never cleared in place under the retained poll engine. Docs corrected (FOCAS.md, AlarmTracking.md, CLAUDE.md). Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe |
||
|
|
f44d8d1e6b | feat(alarms): carry transition Kind on AlarmEventArgs; Galaxy populates it (Phase B WS-1) | ||
|
|
560b327ee1 |
refactor(galaxy): migrate to ZB.MOM.WW.MxGateway.* nupkg packages
v2-ci / build (push) Failing after 33s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Imports the freshly-rebuilt ZB.MOM.WW.MxGateway.Client + ZB.MOM.WW.MxGateway.Contracts nupkgs (0.1.0) from /tmp/mxgw-dist. Replaces the vendored libs/ DLLs and the pre-restructure MxGateway.* namespaces across the runtime Galaxy driver, Galaxy.Browser, and their tests. Key changes: - nuget-packages/ added as a local feed via NuGet.config; .gitignore exempts it from the *.nupkg rule so the packages are tracked - Directory.Packages.props pins both packages at 0.1.0 - 4 csprojs swap <Reference HintPath="libs/...dll"/> for <PackageReference/> - 36 .cs files renamed `using MxGateway.*` -> `using ZB.MOM.WW.MxGateway.*` - libs/ removed (vendored DLLs + README.md) GalaxyBrowseSession rewritten around the new lazy API: - RootAsync calls GalaxyRepositoryClient.BrowseAsync (returns LazyBrowseNodes) and caches them by TagName instead of bulk-fetching the whole hierarchy - ExpandAsync looks up the cached LazyBrowseNode and calls its ExpandAsync, giving true one-wire-call-per-click instead of in-memory parent/child scan - _byGobjectId + _hasChildrenSet dropped (LazyBrowseNode carries HasChildrenHint) - AttributesAsync unchanged (already uses DiscoverHierarchyAsync MaxDepth=0) Tests: Galaxy.Tests 245/245, Galaxy.Browser.Tests 10/10, AdminUI.Tests 66/66. Pre-existing 12 solution errors unchanged (test sinks + Cli XML comments). |
||
|
|
64e3fbe035 |
docs: backfill XML documentation across 756 files
v2-ci / build (push) Failing after 1m43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public members surfaced by commentchecker — resolves 5,847 of 5,869 issues (99.6%) across three /fixdocs passes. |
||
|
|
27a8d05b7c |
feat(driver-galaxy): consume the gateway's session-less alarm model
The mxaccessgw updated alarms to a session-less central monitor: AcknowledgeAlarm dropped SessionId and alarm transitions now come from the session-less StreamAlarms feed instead of the per-session worker StreamEvents stream. The GalaxyDriver no longer compiled against the updated client. - GatewayGalaxyAlarmAcknowledger: session-less rewrite — no GalaxyMxSession; outcome read from ProtocolStatus (throw) and Hresult (warn). - New IGalaxyAlarmFeed seam + GatewayGalaxyAlarmFeed: background consumer of StreamAlarms that decodes the active-alarm snapshot plus live transitions into GalaxyAlarmTransition and reopens the stream on transport faults. - EventPump: drop the dead per-session OnAlarmTransition path; the per-session stream no longer carries alarms. - GalaxyDriver: bridge the feed onto IAlarmSource.OnAlarmEvent; the feed starts on SubscribeAlarmsAsync, independent of data subscriptions. - Tests: replace EventPumpAlarmTests with GatewayGalaxyAlarmFeedTests; move the driver alarm-source tests onto the IGalaxyAlarmFeed seam. Browse needed no change — GatewayGalaxyHierarchySource consumes the unchanged DiscoverHierarchy contract. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |