I-1: Test Connect / browse configs may carry unsaved edits (the device modal merges
the stored DriverConfig with the typed device config). The server
(DriverInstanceIdentities.EffectiveOwnerAsync, used by AdminOperationsActor and
BrowserSessionService) honours the named owner only when every endpoint value
(new DriverCredentialRules.EndpointFields: Galaxy Endpoint, OpcUaClient
EndpointUrl/EndpointUrls/DiscoveryUrl, Heidenhain Host/Port) is one that driver
stores; otherwise the owner is null and its instance-named secrets are refused.
Every Test Connect / browse whose config carries an in-scope secret:/env: reference
is recorded (CredentialUseAudit: IAuditWriter event category CredentialUse + a
structured Information line: user, driver, endpoint hosts, outcome).
L-1: the UserCertificatePath rule is skipped only in an object that explicitly sets
AuthType to non-Certificate (string or ordinal); the deploy gate also checks the
runtime-merged driver+device config so the switch cannot be split from the path; the
form no longer persists the hidden field.
L-2: a ConfigDb fault in the browse check is a refusal; RawBrowseModal catches open
failures into its error message.
L-4: a relative UserCertificateDirectory resolves against AppContext.BaseDirectory.
Co-Authored-By: Claude <noreply@anthropic.com>
#816 finding: the SDK checks that the server certificate names the host only
when a session is created with checkDomain:true. The driver, the AdminUI
browser and Client.Shared all called the 8-argument
DefaultSessionFactory.CreateAsync, which forwards checkDomain:false — so no
host-name check ever ran (why a trusted NAT cert for *.invalid browsed fine
over an IP in #813). When enabled the SDK (Session.OpenAsync ->
ValidateDomains -> FindDomain) compares ConfiguredEndpoint.EndpointUrl.IdnHost
— the CONFIGURED host, because OpcUaEndpointSelection/EndpointSelector
rewrote the advertised one — against the cert's DNS/IP SANs; secured
sessions only, and the auto-accept handler accepts a mismatch.
Policy: certificateValidation.validateServerHostName, tri-state. Unset =
OpcUaCertificateValidationOptions.DefaultValidateServerHostName = false, the
pre-#816 behaviour, so nothing changes on upgrade; true = validate the
configured host; false = explicit NAT/port-publish opt-out. Threaded into the
driver, the AdminUI browser (same JSON) and the AdminUI form (a select that
keeps "unset" unset), Client.Shared ConnectionSettings.ValidateServerHostName
and the CLI --validate-host-name. A driver refusal names the opt-out.
#818: the NAT fixture's /app/pki is on the opc-plc-nat-pki volume (verified:
same thumbprint across --force-recreate), its PUBLIC cert is committed as
Docker/nat/opc-plc-nat-server.der, and NatPublishedEndpointBrowseTests run
every secure browse on a throwaway PKI (internal browser seam): refusal with
nothing trusted, positive with the cert trusted (unset/false host check), and
a BadCertificateHostNameInvalid refusal with the check on. The trusted cert is
OPCUA_NAT_SERVER_CERT or the committed one (skip on thumbprint mismatch);
OPCUA_NAT_SERVER_CERT_TRUSTED is retired. CI exports its throwaway NAT
container's public cert. ServerHostNameValidationTests pin the driver against
the plain opc-plc. MIN_EXECUTED not raised (needs a hosted run): +6 in
v2-integration (440 -> 446), documented in scripts/ci/README.md.
- Endpoint rewrite: the driver now connects to the configured host AND port (scheme
match, advertised path kept) instead of the server-advertised URL — fixes NAT/port-map
upstreams and lets an in-test proxy carry the session (SDK SelectEndpoint rule).
- TcpStallProxy + OpcUaClientDriverStallWireTests: the in-place blip (#670) is now
wire-tested on loopback — one Bad, frozen read stamp, same session, identical value
republished Good, a post-recovery change arrives, no source-time regression after
the SDK's late backlog flush.
- Defect found by that test, fixed: a change published right after a stall rode a
Publish response the SDK timed out and never republished, leaving the node Good on
the pre-change value indefinitely. New trailing reconcile read (Timeout +
KeepAliveInterval after recovery) publishes any Good value newer than the last
accepted one, through the replay guard's mark.
- IDriverConnectionLossSource (Core.Abstractions): opt-in definitive-loss signal.
DriverInstanceActor attaches in PreStart / detaches in PostStop and turns a raise
into a disconnect only while Connected. OpcUaClient raises once per session on
keep-alive BadSessionIdInvalid/BadSessionClosed/BadSessionNotActivated/
BadServerHalted (measured: the SDK never re-opens a halted channel) or a dropped
subscription; ambiguous codes stay with the #527 watchdog.
- Replay guard: one Information summary per recovery when the window closes
("dropped N late notifications across M refs"), with a timer so quiet
subscriptions log it too.
- ReconnectPeriod deleted (options, AdminUI form, docs, tests); stored configs that
carry reconnectPeriod still parse in the factory, probe and browser.
- Docs: OpcUaClient.md, DriverLifecycle.md, driver-specs.md, CLAUDE.md.
Nothing read the mapping table beyond the startup validator; v3 UNS projection is
explicit via UnsTagReference. Legacy keys in stored DriverConfig are ignored (pinned).
Reverts the docker-dev opc-plc seed workaround from fdee129f.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Part 1 — rewire the three DriverType dispatch maps from hand-authored string
literals to the canonical DriverTypeNames constants (single source of truth):
- TagConfigEditorMap, TagConfigValidator (AdminUI)
- EquipmentTagConfigInspector (ControlPlane)
This FIXES the live drift ("TwinCat"->TwinCAT, "Focas"->FOCAS). The maps are
OrdinalIgnoreCase so behavior is identical; the value is no future drift.
Calculation is not added to the inspector (no CalculationTagDefinitionFactory.Inspect).
Added TagConfigDriverTypeNameGuardTests pinning the maps to the constants.
Part 2 — retire the routed /clusters/{id}/drivers driver-authoring flow (/raw
Waves A-C now cover driver/device/tag authoring end-to-end):
- Deleted DriverTypePicker, DriverEditRouter, the 8 *DriverPage shells, and the
ClusterDrivers list page.
- Removed the "Drivers" tab from ClusterNav. Routes /clusters/{id}/drivers* now
simply do not exist -> clean 404.
- The Forms/DeviceForms bodies, shared driver sections, and address pickers used
by the /raw modals are untouched.
Part 3 — updated PageAuthorizationGuardTests census: removed the 10 deleted
ConfigEditor pages + ClusterDrivers, updated group-count comments (ConfigEditor
21->11, AuthenticatedRead 17->16). Removed the now-dead Clusters.Drivers usings
from the 4 *DriverPageFormSerializationTests + the guard test.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Extract the 8 typed driver pages into embeddable <Driver>DriverForm bodies
(channel/protocol config) and add per-driver <Driver>DeviceForm bodies
(connection endpoint -> Device.DeviceConfig, v3 endpoint split). New
DriverConfigModal + DeviceModal dispatch by DriverType (DriverTypeNames) for
the /raw tree; Test-connect inside DeviceModal builds the merged Driver+Device
config transiently via DriverDeviceConfigMerger. Routed pages now host the
form bodies and keep working. Round-trip + enum-serialization guard tests for
the Modbus driver form + Modbus device model; retargeted the existing
page-form serialization tests + the _jsonOpts converter guard to the forms.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
- S7DriverPage.FormModel now preserves Tags through Form ↔ Options
translation (was hard-coding Tags = [] on every save, silently
destroying any tag list that operators had configured).
- Add FormModel_RoundTrip tests for OpcUaClient and Historian
mirror classes — both were translating Options ↔ form-model
entirely untested.
- Surface S7 Tags in the round-trip test so this regression
can't reach merge again.