On a wire the native PCCC path is proven only for N-file reads/writes and
one F8 read (ab_server). An absent transport key now resolves to Libplctag
for every family; explicit Native still wins and still warns once per
instance on PLC-5/LogixPccc. AdminUI dropdown, CLI help, evidence claims
(PcccFileType, AbLegacy.md wire-evidence table, release note) corrected:
S:0 (default probe) and B/T/C/R/S/L/ST/A/O/I are unverified natively.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- I1: the upgrade restart itself moves every no-key AbCip/AbLegacy driver to Native (every process
start constructs drivers, incl. boot-from-cache). Docs + CLAUDE.md now say so and tell operators
to set "transport": "Libplctag" BEFORE upgrading (older builds ignore the unknown key).
- I2: AbLegacy release note leads with the status-bit write refusal (T4:0.DN, C5:0.CU, R6:0.EN, ...)
on defaulted SLC/MicroLogix drivers and the fallback. The real client status is
BadCommunicationError, not BadNotSupported (the driver's write catch-all maps the runtime's
AbTransportException like any transport failure, as #571 does for PLC-5), with handle eviction
and Degraded health; pinned by a driver-level test (no 0xAA write on the wire, with a positive
control). ST string byte order stated as unverified. Also corrects the docs' "T4:0/DN" examples:
the driver's address grammar is "T4:0.DN" ("/DN" is a malformed address).
- I3: DriverProbeHandshakeE2eTests' two AbCip probe tests are a [Theory] over Native and
Libplctag. Run against ab_server controllogix: all 4 rows pass with identical exact messages.
- M1: documented (docs + resolver XML doc): the AdminUI merges only the probed device, so a
mixed-family defaulted AbLegacy driver can probe Native while running Libplctag.
- M2: factory ParseEnum rejects undefined integer strings ("7") via Enum.IsDefined (both drivers).
- M3: AbCip driver-level bad value reads "AB CIP config in '<id>' has unknown Transport ..."; the
named constant is gone (tagName: null now means driver-level).
- M4: the explicit-Native limited-family Warning is once per instance, not per (re)init.
- Nit: EffectiveTransport docs note that injected factories bypass it.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Task 22 (spec section 8 P5), with the controller rulings that exclude PLC-5 and LogixPccc.
- Transport is nullable on both option records; null (key absent) means "use the default" and is
never serialized. Factory DTO parse: absent -> null; a bad value still fails via ParseEnum.
- One resolver per driver (AbCipTransportResolver / AbLegacyTransportResolver), used by the driver
constructor, the Test Connect probe and (through the driver) the CLI.
AbCip: null -> Native. AbLegacy: null -> Native unless any device is Plc5 or LogixPccc, then the
whole driver resolves to Libplctag. Explicit values always win; explicit Native with a
Plc5/LogixPccc device logs one Warning at init.
- Init log shows configured vs effective, e.g. transport=Native (default).
- AdminUI forms: "Default (...)" / "Native (managed)" / "libplctag (fallback)". Default omits the
key on save (reverses Task 19's explicit re-emit, which would have pinned every edited driver).
- CLIs: --transport default|native|libplctag, default "default" via the resolver, so
--plc-type Plc5 with no --transport runs libplctag.
- Tests pinned to Libplctag where a default-path runtime was created: found by instrumenting the
native factories with the current xUnit test name (one unit test, AbLegacyReinitConfigAdoption;
plus the two fixture-gated AbCip probe E2E tests whose exact messages were proven on libplctag).
TransportMatrix and the differential harness already pass explicit transports.
- Switch/resolver/CLI/form tests are falsified by mutating the resolver (default -> Libplctag,
exclusion removed, AbLegacy default -> Libplctag): each mutation turns them red.
- Replaces the inline role-name literal in AbCipDriverFactoryExtensions' ParseEnum call with a named
constant; RoleAuthorityGuardTests was already red on the base commit for that line.
- Docs: AbCip.md / AbLegacy.md default + release note; CLAUDE.md AB section.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Five drivers ignored the config handed to them on reinitialize, serving the
options their constructor captured — and the deployment sealed green anyway.
Fixed on both halves, as chosen.
Seam (load-bearing): DriverSpawnPlanner routes a changed DriverConfig to
ToStop + ToSpawn instead of an in-place delta, making the factory the single
parse authority. This REVERSES the deliberate decision documented at
DriverSpawnPlan.cs:49-50 ("a pure DriverConfig change stays an in-place delta
— no reconnect"). That reasoning was correct about the resilience pipeline and
wrong about the driver. The accepted price is a reconnect per config edit.
Per-driver, and this split was not anticipated:
- Re-parse in place — Modbus, AbLegacy, OpcUaClient. ParseOptions extracted
from each factory, called from InitializeAsync behind a HasConfigBody guard
so "{}" still keeps the constructor options.
- Respawn-only, deliberately NOT re-parsed — Sql and FOCAS. Each builds more
than options from config (Sql's dialect + resolved connection string,
FOCAS's client-factory backend, both injected at construction), so adopting
new options alone would run a NEW tag set against an OLD connection. Half a
re-parse is worse than none. SqlDriver's doc-comment asserted the opposite
premise — "config parsing belongs to the factory, which builds a fresh
instance" — which was false when written and is true only now.
Two green seals removed from ApplyChildDelta: it overwrote the cached Spec
synchronously BEFORE the child dequeued the message, so the host believed the
new config was live and the next reconcile computed no delta, sealing the
drift permanently; and it Tell'd with no Receive<ApplyResult> registered, so a
failed reinit — including Galaxy's deliberate NotSupportedException —
dead-lettered.
Exposed (not created) by the change: a factory throw is a CONFIG error, and
SpawnChild catches it and silently substitutes a stub. Only a brand-new driver
could reach that before; an ordinary config edit can now. Raised Warning ->
Error with an actionable message. It still does not fail the deployment —
doing so would let one malformed driver block a fleet deploy, so that is a
follow-up rather than a drive-by.
Tests: every pre-existing reinit test in these suites passes "{}", the exact
input a guarded re-parser treats as "keep constructor options" — blind to this
defect by construction. New tests pass CHANGED json; the Modbus one was
verified falsifiable by deleting the re-parse (goes red). Two tests asserted
the old behaviour and were rewritten, including the positive control in
DriverHostActorUnreadableArtifactTests, whose observable moved from
UnsubscribeAsync to ShutdownAsync now that teardown happens by stopping the
child rather than emptying its desired set.
Remaining full-suite failures are pre-existing and environmental, verified
identical on the pre-change tree: Host.IntegrationTests (3) and
Driver.AbLegacy.IntegrationTests (4, docker fixture-gated).
Follow-ups from the fleet-wide read-timeout audit that the S7 R2-01 read-leg
fix (PR #453) prompted. The audit confirmed S7 was the ONLY driver with the
async-read-ignores-socket-timeout hang; these are the two adjacent (non-hang)
findings it surfaced.
1. FOCAS TimeoutMs:0 footgun (the risky one): a non-positive Timeout made
SynchronizedFocasClient DISABLE its per-call wall-clock ceiling, reverting to
the caller's long-lived poll token — reintroducing exactly the frozen-peer
wedge S7 just eliminated, under misconfig. Clamp non-positive TimeoutMs to the
2s default at the config boundary so the deadline can never be authored away.
2. TimeoutMs validation symmetry: apply the same clamp in the AbCip + AbLegacy
factories. libplctag's Tag.Timeout setter throws on <=0, faulting tag creation
on every read/write; clamping keeps a misconfigured TimeoutMs:0 running on the
default bound instead. (Shared PositiveTimeoutOrDefault helper per factory.)
3. AbLegacy reconnect parity with AbCip: AbLegacy evicted the cached libplctag
runtime on neither the non-zero-status nor transport-exception read/write path
(AbCip evicts on both), so a data-path fault recovered only via the probe loop
/ libplctag internals. Added EvictRuntime + wired it into both read and write
failure paths so a fresh handle is created on the next call.
Tests: FOCAS 265->269 (clamp theory + positive), AbCip 336->339 (clamp theory +
positive), AbLegacy 209->212 (read-nonzero / read-exception / write-nonzero evict).
No production regressions; all three driver suites green.
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
- Driver.AbLegacy-005: optional ILogger<AbLegacyDriver> ctor parameter,
logged init failure / probe transitions / first non-zero libplctag
status per device.
- Driver.AbLegacy-011: Dispose() runs the synchronous teardown directly
instead of bridging via DisposeAsync().AsTask().GetAwaiter().GetResult()
to remove the documented sync-over-async deadlock pattern.
- Driver.AbLegacy-013: documented the ResolveHost three-tier fallback
chain in XML and pointed DiscoverAsync's IsArray=false comment at the
Modbus ArrayCount pattern for the eventual multi-element follow-up.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.
- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
integration, install).
Build green (0 errors); unit tests pass. Docs left for a separate pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>