Joseph Doherty 52708bff52 fix(address-space): numeric array writes convert (checked) to the node element type; array-to-scalar refusal only for Modbus/S7 (#610 review R6)
MAJOR-1: R4's exact element-type match refused ScadaBridge's CLR-list
writes (its element types are only Boolean/Int32/Float/Double/String/
DateTime) to every Int16/UInt16/Byte/UInt32/Int64/UInt64 array node and a
Double list to a Float array. EvaluateEquipmentWriteStructure now converts
a numeric array of another numeric element type element-wise, CHECKED, into
the node's element type and hands the converted array back through
OnEquipmentTagWrite's ref value, so the node stores and the driver receives
the node's own type. Any out-of-range, fractional-to-integer, NaN/Inf-to-
integer or Float-overflowing element refuses the whole write BadTypeMismatch
(nothing dispatched) - so the UInt32 -> Int32 bit reinterpretation stays
closed. Non-numeric mismatches stay refused. The wrong 'no client relies on
a looser rule' comment is corrected.

MINOR-1: the array-value-to-scalar-node refusal broke writes back to
browse-committed array tags (committed scalar, isArray never set) on
pass-through drivers. It now applies only when the owning driver's scalar
encoder cannot take an array (DriverArrayWriteSupport.
RefusesArrayValueOnScalarTag: Modbus, S7), carried RawTagPlan.
ScalarRefusesArrayValue / UnsReferenceVariable.BackingScalarRefusesArrayValue
-> EnsureVariable(refuseArrayOnScalar) -> a per-node set in the node
manager. OpcUaClient/Galaxy/others keep pre-#610 dispatch. Not on the
classifier whitelist (driver-type edit rebuilds); a mirror whose flag
changes is recreated, not updated in place.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 08:31:46 -04:00
Joseph Doherty 18f8eb5d2f feat(address-space): server-side array writes gated per driver capability (#610)
Array nodes were forced read-only for every driver. A new single authority,
Core.Abstractions DriverArrayWriteSupport, says which (driver, element type)
pairs encode a whole-array write: Modbus (Coils / numeric HoldingRegisters),
S7 (Byte/Int16/UInt16/Int32/UInt32/Float32), OpcUaClient (pass-through) and
Galaxy (Boolean/Int32/Int64/Float/Double/String/DateTime). Everything else
stays read-only, so the server never advertises a write the driver refuses.

- Composer derives RawTagPlan.ArrayWritable + UnsReferenceVariable
  .BackingArrayWritable at compose time (both seams, byte-parity); the
  applier's one writability rule is Writable && (!IsArray || ArrayWritable)
  for materialise and surgical paths, raw and UNS alike.
- ArrayWritable is on the classifier's surgical raw-tag whitelist and
  mirrored on the UNS record (UnsReferenceBackingParityTests updated).
- Node manager refuses a wrong-length / non-array value on an array node
  (BadTypeMismatch) and any IndexRange write (BadWriteNotSupported) inline,
  before dispatch; WriteOperate/ACL gates and the revert are unchanged.
- Per-driver parity tests pin the table against the real Modbus write path,
  S7 EncodeArrayBlock and Galaxy MxValueEncoder (UInt32/UInt64 excluded:
  array covariance reinterprets their bits).
- Over-the-wire proof in OpcUaServer.IntegrationTests (ArrayWriteWireTests).
- ValueRank > 1 documented as out of scope by decision (docs/Uns.md).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 07:39:05 -04:00
Joseph Doherty bfbdce32e4 perf(opcuaserver): non-rebuild applies materialise the delta, not the composition 2026-08-15 17:26:53 -04:00
Joseph Doherty 875ec9fe47 fix(opcuaserver): UNS reference nodes repair on backing-tag historian/shape edits
Adversarial review of 9f68f272 (classifier: non-alarm raw-tag deltas became
surgical) found stale UNS inheritance after a surgical raw edit. Editing a raw
tag's IsHistorized / HistorianTagname / IsArray / ArrayLength left every
referencing UNS node STALE: none of those fields were on UnsReferenceVariable,
so no coincident UnsReferenceDelta fired; the applier updated the raw node in
place; and EnsureVariable early-returns on an existing node. Consequences:
HistoryRead through the UNS NodeId served a different series than through the
raw NodeId (breaking the documented dual-registration invariant), a
de-historized tag kept serving history via UNS, and a scalar->array flip left
the UNS mirror scalar AND writable (bypassing the array read-only write gate).

UnsReferenceVariable now carries Backing{IsHistorized,HistorianTagname,IsArray,
ArrayLength}, copied from the backing tag's TagConfigIntent at compose time, so
record equality makes the reference Changed in the SAME plan. Both deltas are
non-rebuild kinds, so the existing machinery repairs the mirror surgically:
remove-previous in Apply, recreate in MaterialiseUnsReferences. That pass now
reads the four values from the RECORD (the single truth the planner diffed)
instead of a rawByPath back-lookup, preserving historian resolution exactly
(blank override => BackingRawPath, which is the backing tag's NodeId).

The artifact-decode seam needs no change: DeploymentArtifact.BuildRawAndUnsSubtrees
drives AddressSpaceComposer.Compose verbatim, which is what guarantees byte-parity.
The classifier needs no change either (a UnsReferenceDelta never forces Rebuild);
its comment now records why.

Also from the same review: a three-place-contract comment on RawTagPlan's
hand-written Equals naming its two downstream consumers, plus classifier pins for
the .Any(!eligible) quantifier, an ArrayLength-only delta, and an
alarm-content-only delta.
2026-08-15 17:11:03 -04:00
Joseph Doherty 2d20aeb779 fix(opcua,drivers): carry driver status sub-codes to clients (#519) + health-write ordering (#517)
#519 — a driver's OPC UA status code now reaches a client with its sub-code intact.
DriverInstanceActor projected the driver's uint onto a 3-state Good/Uncertain/Bad enum
and OtOpcUaNodeManager re-expanded Bad to a bare 0x80000000, so BadNoCommunication,
BadTypeMismatch and BadNotSupported were indistinguishable on the wire and every
driver's status constants (incl. the 16 #497 had just corrected) were diagnostic in
logs only. Resolved by option (b): the raw uint rides AttributeValuePublished ->
AttributeValueUpdate -> IOpcUaAddressSpaceSink.WriteValue, OpcUaQuality is deleted, and
severity classification is a helper (OpcUaStatus.IsGood/IsUncertain/IsBad).

The surface was wider than the issue costed (41 files, not "the sink and 3
implementations"): OpcUaQuality had non-driver producers with no uint to carry.
Each got its natural code — BadInternalError for a failed virtual-tag script,
BadNoCommunication for driver comms loss — and ScriptedAlarmHostActor's pair of
mutually-inverse uint<->enum mappers is deleted, having round-tripped a code the
engine already held. AddressSpaceApplier's removal writes deliberately keep the
generic Bad: not losing a code the driver had is this issue; inventing one for the
deploy path is a separate call.

Behaviour change: WriteAlarmQuality fires its Part 9 event on a status-code change
rather than a severity-bucket change. While the annotation was 3-state those were the
same predicate; now a move between two Bad reasons changes what a subscriber reads.

New SDK-free named constants live on Commons.OpcUa.OpcUaStatus, and
StatusCodeParityTests is widened to cover them — that guard is reflection-driven, so
it can only see a named constant, never an inline literal.

#517 — the symptom is real but the issue named the wrong path and its fix was unsafe.
ShutdownAsync cannot race: DriverInstanceActor calls it from PostStop, after the
mailbox drains. (Core/Hosting/DriverHost, the one class with a concurrent GetHealth,
has no production call site.) InitializeAsync can: it runs on a fire-and-forget
Task.Run, and MTConnectDriver writes Healthy then starts loops that can throw into a
catch which disposes the client before writing Faulted.

Moving the write earlier, as suggested, inverts the terminal state — teardown drains
in-flight loops that write health as they unwind, so a late loop could leave Healthy at
rest with every connection closed. The fix is a bracket (conservative before, terminal
after), applied to MTConnect's init-failure path only; shutdown keeps its single
trailing write, and the rule plus the reachability table are documented on
IDriver.ShutdownAsync.

CalculationDriver.GetHealth returned a hard-coded Healthy that consulted nothing —
Healthy before initialize, after shutdown and after dispose. Now derived from _running.
Its test, named Health_is_always_Connected, asserted the defect and is replaced.

Every new guard was falsified by breaking the production code and watching it go red.
The two sub-code tests each assert two different Bad codes, since a single-code
assertion could pass against a hard-coded constant under the old projection.

Pre-existing failures, verified unchanged on a stashed tree and not chased: 4 in
Driver.AbLegacy.IntegrationTests (slc500/micrologix/plc5 fixtures not up) and 3 in
Host.IntegrationTests.

Closes #517
Closes #519

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 05:25:27 -04:00
Joseph Doherty db751d12a5 feat(alarms): condition Quality tracks source connectivity (#477)
v2-ci / build (pull_request) Successful in 4m49s
v2-ci / unit-tests (pull_request) Failing after 3h11m25s
Part 9 ConditionType.Quality was never assigned; default(StatusCode)==Good
so every native + scripted condition reported Good unconditionally — a
comms-lost device still showed a healthy, inactive, Good condition (a
wrong-VALUE bug, distinct from the null-value #473/#475). Clients (and HMIs
bucketing on IsGood) could not tell "genuinely inactive" from "lost contact".

Layer 1 — make Quality a real, plumbed field:
- AlarmConditionSnapshot gains OpcUaQuality Quality (default Good).
- MaterialiseAlarmCondition sets it (native BadWaitingForInitialData, scripted Good).
- WriteAlarmCondition projects snapshot.Quality; the delta-gate gains a Quality
  member so a quality-bucket change fires a Part 9 event.

Layer 2 — drive native quality from driver connectivity (a comms-lost driver
emits no alarm transitions, and an alarm-bearing raw tag has no value variable,
so quality can't come from either existing channel):
- DriverInstanceActor Tells parent ConnectivityChanged on Connected/Reconnecting.
- DriverHostActor fans it to every native condition the driver owns as
  OpcUaPublishActor.AlarmQualityUpdate (Good on connect, Bad on disconnect).
- New dedicated IOpcUaAddressSpaceSink.WriteAlarmQuality sets ONLY Quality and
  fires only on a bucket change — never touches Active/Acked/Retain (an active
  alarm that loses comms stays active). Not a full-snapshot re-projection, so it
  can't clobber severity/message and works for a never-fired condition.
  Forwarded through DeferredAddressSpaceSink (F10b trap; auto-verified by the
  reflection forwarding guard). Ungated by redundancy role; no /alerts row.

Scripted conditions stay Good; worst-of-input quality deferred to #478 (Layer 3).

Tests: node-level (materialise/project/no-clobber/unknown-node no-op),
NativeAlarmProjector, DriverInstanceActor connectivity emission, DriverHostActor
fan-out, OpcUaPublishActor routing, and the wire-level guard
(Condition_event_Quality_tracks_source_connectivity_on_the_wire) — RED-verified
against a simulated pre-fix always-Good server. Existing DriverInstanceActor
parent probes ignore the new ConnectivityChanged.

Docs: docs/AlarmTracking.md §"Condition source-data Quality (#477)";
design doc docs/plans/2026-07-17-alarm-condition-quality-477-design.md.
2026-07-17 15:10:04 -04:00
Joseph Doherty 3cf3576c75 fix(v3-batch4-wp4): alarm fan-out hardening — event-delivery test, resolution-failure meter, teardown guards (Wave C review M1/M2/M3/L1/L3)
M1 — over-the-wire event-delivery proof (new NativeAlarmMultiNotifierEventDeliveryTests
in OpcUaServer.IntegrationTests): boots the real server, wires one condition to two
equipment folders, fires ONE transition, and asserts a Server-object subscriber gets
EXACTLY ONE event (the shared-InstanceStateSnapshot queue dedup), plus overlapping
Server + equipment-folder subscribers each get exactly one copy. Captures via the
subscription FastEventCallback keyed by ClientHandle (the per-item Notification/DequeueEvents
path delivers nothing for these conditions in the SDK client — the working capture is the
fast callback).

M2 — resolution-failure signal + path-agreement tripwire (AddressSpaceApplier): when a
native alarm HAS ReferencingEquipmentPaths but NONE resolve to an equipment folder, count
it as a failed node (degraded-apply meter) + LogWarning instead of a silent skip; documented
the DisplayName==Name coupling as a binding invariant. Tests:
Composer_referencing_equipment_paths_resolve_back_to_equipment_ids_in_the_applier (real
composer output → applier inversion) + ..._unresolvable_referencing_equipment_counts_as_failed.

M3 — WireAlarmNotifiers is now a RECONCILE (unwires a folder dropped from the supplied set,
bidirectionally) so a future surgical ChangedRawTags path can't leave a de-referenced
equipment receiving the alarm; binding guard comment added on the classifier's
ChangedRawTags→Rebuild branch. Test: WireAlarmNotifiers_reconciles_a_dropped_folder_out_of_the_notifier_set.

L1 — MaterialiseAlarmCondition's kind-swap drop-and-recreate now calls
UnwireAlarmNotifiers(conditionKey) before discarding the old instance (teardown symmetry).

L3 — BuildEquipmentIdByFolderPath LogWarnings on a duplicate Area/Line/Name collision
(defense-in-depth; UNS uniqueness prevents it).

Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
2026-07-16 12:52:34 -04:00
Joseph Doherty 8ebc712eff feat(v3-batch4-wp4): multi-notifier native alarms (single ReportEvent → raw + equipment notifiers) + teardown symmetry
Materialize each native alarm ONCE at the raw tag (ConditionId = RawPath, Raw
realm); wire the single condition as an SDK event notifier of each referencing
equipment's UNS folder so one ReportEvent fans to every root without
re-reporting per root (which would break Server-object dedup + Part 9 ack
correlation).

- New sink method WireAlarmNotifiers(alarmNodeId, alarmRealm,
  notifierFolderNodeIds, notifierFolderRealm) on IOpcUaAddressSpaceSink,
  forwarded through DeferredAddressSpaceSink + SdkAddressSpaceSink +
  NullOpcUaAddressSpaceSink (the forwarding-trap guard); auto-covered by the
  DeferredSinkForwardingReflectionTests realm + forwarding guards + a
  hand-written forward test.
- OtOpcUaNodeManager: the normative AddNotifier(isInverse) pair + idempotent
  EnsureFolderIsEventNotifier per equipment folder; tracked per condition in
  _alarmNotifierWiring. Teardown symmetry: RemoveNotifier(bidirectional:true) on
  RebuildAddressSpace, RemoveAlarmConditionNode, and RemoveEquipmentSubtree so no
  inverse-notifier entry leaks across redeploys.
- AddressSpaceApplier.MaterialiseRawSubtree wires notifiers for each native alarm
  tag, resolving its ReferencingEquipmentPaths (Area/Line/Equipment) to the
  EquipmentId folder NodeIds via BuildEquipmentIdByFolderPath.
- AlarmTransitionEvent gains ReferencingEquipmentPaths (empty default); /alerts
  renders the referencing-equipment list as display metadata.
- Un-skipped + rewrote the native-alarm dark tests
  (DriverHostActorNativeAlarmTests x6, DriverHostActorNativeAlarmAckRoutingTests
  x1) for the v3 raw-condition model; new NodeManagerMultiNotifierAlarmTests
  proves multi-notifier wiring + teardown symmetry (no leaked duplicates after a
  re-trip) + applier wiring test.

Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
2026-07-16 12:07:11 -04:00
Joseph Doherty 3efcf8014b feat(v3-batch4-wp3): raw-only binding + UNS fan-out + write routing
Wave B of Batch 4 — the runtime binding seam for the dual namespace.

Applier (both realms, explicit realm at every sink call site):
- MaterialiseRawSubtree: Raw containers as folders + Raw tags as variables
  keyed by RawPath (native-alarm tag → single Part 9 condition at the RawPath),
  all in AddressSpaceRealm.Raw; historian tagname = override else RawPath.
- MaterialiseUnsReferences: each UNS reference Variable under its equipment
  folder (Uns realm) + an Organizes UNS->Raw edge; inherits writable/array/
  historian tagname from the backing raw tag (both NodeIds -> one tagname).
- FeedHistorizedRefs / ProvisionHistorizedTags now source RAW tags (mux ref
  stays single, keyed by RawPath); ApplyPureRemove tears down raw tags + UNS
  refs in place (raw-container removal falls back to rebuild).

DriverHostActor (dual-NodeId, single-source fan-out):
- _nodeIdByDriverRef value gains a realm (NodeRealmRef); rebuilt from
  RawTags UNION UnsReferenceVariables so one (DriverInstanceId, RawPath) fans
  to the raw NodeId AND every referencing UNS NodeId with identical
  value/quality/timestamp. Write inverse map keyed by the bare id; the
  ns-qualified NodeId the write hook passes is normalised (BareNodeId) so a
  write to either NodeId resolves the same driver ref (-> RawPath write).
- Native raw alarm condition routing is realm-tagged (Raw); AttributeValueUpdate
  + AlarmStateUpdate carry the realm through to the sink.

Retire EquipmentNodeIds -> V3NodeIds.Uns (applier/VirtualTagHostActor) and
RawPaths.Combine (DiscoveredNodeMapper, discovered nodes are Raw now).

DeploymentArtifact.ParseComposition emits the Raw + UNS subtrees byte-parity
with the composer (reconstruct entities -> AddressSpaceComposer.Compose).

Sink surface: removed the transitional `= AddressSpaceRealm.Uns` defaults from
IOpcUaAddressSpaceSink / ISurgicalAddressSpaceSink / SdkAddressSpaceSink /
DeferredAddressSpaceSink / NullOpcUaAddressSpaceSink — every call site is now
explicit (realm reordered before the trailing optionals on EnsureVariable +
MaterialiseAlarmCondition). Node-manager convenience methods keep their
defaults (they are not the interface impl; Sdk delegates explicitly).

Tests: rewrote DriverHostActorLiveValueTests (fan-out drift, 1:N) +
DriverHostActorWriteRoutingTests (dual-NodeId raw/uns write routing) to the v3
raw+uns model; new AddressSpaceApplierRawUnsTests; migrated the EquipmentTags
provisioning/feed tests to RawTags; swept EquipmentNodeIds test callers.