Joseph Doherty 9631a40f1f fix(mtconnect): resetTriggered only resets data sets; empty set is Good {}; re-baseline test (#650 review)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:20:23 -04:00
Joseph Doherty 6c63bf8fab fix(mtconnect): back off a /sample re-baseline that resolved nothing; scope Test Connect to the configured device
Driver.MTConnect-001 (Medium): StreamVerdict.Reopen reset the reconnect ladder
unconditionally. The InvalidDataException catch that routes an Agent OUT_OF_RANGE
to a /current re-baseline also catches an unparseable chunk and an over-sized
multipart part - neither of which a re-baseline can resolve - so the pump reopened
and failed with no delay at any point: two HTTP requests and one Warning per
iteration, forever. The Reopen arm now uses the same discriminator the transient
arm does (did THIS connection deliver a chunk?), so a buffer roll behind a working
stream still reopens instantly while a re-baseline that resolved nothing advances
BackoffFor.

Driver.MTConnect-002 (Medium): MTConnectDriverProbe requested {AgentUri}/probe
while MTConnectAgentClient requests {AgentUri}/{DeviceName}/probe, so a mistyped or
since-renamed deviceName showed GREEN on Test Connect and then Faulted the driver
at InitializeAsync (an unknown device path answers MTConnectError under HTTP 200).
The probe's minimal DTO now reads deviceName - the rule is 'which keys compose the
URL', not 'which keys are cheap to read'.

Driver.MTConnect-008 (Low): corrected two stale claims that a since-changed
RawBrowseCommitMapper invalidated (see Driver.MTConnect-003, which remains open and
belongs in AdminUI), and made DiscoverAsync log the options snapshot it
deliberately read once instead of the field.

Tests: 538 pass (534 base + 4 new, each red before its fix); AdminUI.Tests 1466 pass.
2026-08-10 06:51:39 -04:00
Joseph Doherty dfbcb0e7f0 fix(mtconnect): close the silent-refusal + teardown-wedge defects in the pump (Task 11 review)
C1 (critical): a latched "this endpoint cannot stream" verdict could end with a
GREEN driver holding a permanently silent subscription. DriverInstanceActor
handles a tag-set change as Unsubscribe-then-Subscribe with no re-initialize;
the unsubscribe cleared the stream-degraded flag, the resubscribe was refused by
the latch without a word, and one successful read then reported Healthy.
StartSampleStreamCore now re-asserts the degradation and logs a Warning naming
the remedy, and teardown no longer clears the flag while the latch is set.

NOT promoted to Faulted: DriverHealthReport maps any Faulted driver to a /readyz
503, so that would de-ready the whole node over one misconfigured Agent whose
reads are perfectly healthy. Faulted stays for the case that earns it.

I1: teardown waits are bounded (5 s) and honour the caller's token. They were
unbounded and ignored it, so DriverInstanceActor's 5 s budget was inert and
PostStop — which blocks a dispatcher thread on ShutdownAsync while holding the
lifecycle semaphore — could be wedged forever by one blocking subscriber. The
cancellation source is disposed only when the loop is provably gone. Applied to
StopProbeLoopAsync too: Task 13 reproduced the identical shape, and closing the
class in one method while leaving the other as the pattern to copy is worse than
not closing it.

I2: the reconnect ladder was monotonic for the process lifetime, so ~9 unrelated
drops pinned the driver at MaxBackoffMs forever. A stream that delivered before
dropping now starts a fresh ladder (at attempt 1, not 0, so MinBackoffMs is
still honoured).

I3: MaxBackoffMs <= 0 clamped every delay to zero — an operator-authorable
reconnect spin. Treated as unset, like a multiplier that cannot grow.

I4: the session published instanceId without NextSequence, so after a restart it
held the new agent's id beside the dead one's cursor, and a gap/OUT_OF_RANGE
re-baseline (id unchanged) never published the cursor at all. Both move in one
CAS, and the pump publishes its cursor as it exits.

I5: OnDataChange was a multicast Invoke — the first throwing handler aborted the
rest of the list, starving every later subscriber. Now walked by hand with the
catch inside the loop. The test that claimed to cover this registered the
recorder BEFORE the thrower, so it passed regardless; swapped, it was red.
Faults are latched to one Warning per stream generation (Debug thereafter) so a
consistently-throwing consumer cannot flood the log.

Also: the pump restarts after an unexpected fault (IsCompleted, not null); a
device-scope that matches nothing is a Warning, not a Debug tally; a device or
component with neither name nor id is skipped rather than emitting a blank path
segment; DiscoverAsync's remark no longer claims DriverInstanceActor retries
(it does not for a Once driver, and injection is dormant in v3); and two flake
seeds in the fake are gone (Dispose re-read its own counter; _disposeCts was
disposed under a racing SampleAsync).

439/439. Every changed behaviour falsified by mutation.
2026-07-27 13:57:46 -04:00
Joseph Doherty 9a67ed918a feat(mtconnect): ISubscribable /sample pump + ring-buffer re-baseline (Task 11)
One shared /sample long poll behind every subscription handle. Subscribe fires
initial data per reference from the primed /current (Part 4 convention) and
returns without waiting on the stream; the pump runs on its own task under its
own token — never the caller's Subscribe token, which is disposed the moment
that call returns.

The pump owns every way the sequence can break:

- sequence gap, measured against the RUNNING cursor (the previous chunk's
  nextSequence). Comparing against the opening `from` reports a gap on every
  chunk once the buffer rolls — a /current re-baseline storm.
- OUT_OF_RANGE under HTTP 200 (InvalidDataException out of SampleAsync), which
  IsSequenceGap cannot see at all — without it a driver recovers from falling a
  little behind but not from falling a lot.
- agent restart, checked BEFORE the gap because a restart resets sequences and
  so usually trips the gap check too; it clears the index (the held values
  describe a device model that no longer exists) and tells the subscribers.
- every chunk advances the cursor, heartbeats included.

Re-baseline calls CurrentAsync directly on the client the pump already holds:
routing it through ReinitializeAsync would take the non-reentrant lifecycle
semaphore from inside a pump a lifecycle method may already be awaiting, and
hang the driver with no exception and no log. StopSampleStreamAsync is filled
in (same call sites) and InitializeAsync now stops the stream before teardown
too, so a re-Initialize on a live instance cannot leave a pump enumerating a
disposed client.

MTConnectStreamEnded/TimeoutException reconnect under a geometric backoff with
a 100 ms growth floor (MinBackoffMs defaults to 0, and 0 x multiplier is still
0). MTConnectStreamNotSupportedException does NOT retry — it latches, reports
loudly, and is cleared only by a re-initialize.

Health precedence is explicit: /current and /sample fail independently, so each
path owns a flag, clears only its own, and Healthy requires both clear. Neither
can paper over the other's failure.

29 new tests, all deterministic — no sleeps, no wall-clock assertions. The fake
grew per-generation sample streams (so a reconnect has somewhere to land),
scripted /current answers, scripted sample failures, and a chunk-consumed
signal that also fires when the consumer abandons the stream. 375/375 green.
2026-07-27 13:57:46 -04:00