Commit Graph

888 Commits

Author SHA1 Message Date
Joseph Doherty a0b635f673 fix(s7): probe gate contention is no verdict; Test Connect honours timeoutMs (R07:H7)
- The background probe reported the host Stopped whenever a read pass held
  _gate past the probe deadline: contention is the connection being used,
  not lost. A contended tick now gives no verdict (counted for tests); a
  real probe failure still reports Stopped. A tick that races a teardown no
  longer reopens a connection on an uninitialised driver.
- S7DriverProbe deserialised S7DriverOptions directly, whose Timeout is a
  TimeSpan no config names, so "timeoutMs" was ignored and every handshake
  waited the whole Test Connect budget. The handshake and test read are now
  bounded by timeoutMs, capped by the caller's timeout.

Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:33:38 -04:00
Joseph Doherty 1f7ab80b81 fix(s7): a refused span falls back per member and is not regrouped (R07:P2)
A span's block is the union of its members' ranges, so one member that runs
past the DB's real end (or over-declares a STRING) made the CPU refuse the
whole block, and every neighbour within it was Bad on every poll. The
planner's stated invariant (a grouped read cannot fault where per-tag reads
would succeed) was false; the multi-var path already fell back, spans did not.

- A refused multi-member span hands its members back; they are read one at a
  time for that pass, bypassing the multi-var pass.
- _noGroup remembers the members refused on their own (or every member when
  none was) and keeps them out of later plans, so the rest group again. It is
  cleared by every initialize publish. Non-refusal span failures are
  unchanged (every member stamped).
- The once-per-tag refusal Warning memo (R07:H4) is now also cleared by the
  publish, and shutdown resets the write-side Degraded owner, as documented.
- Live gate: MW10 + MD254 (2 bytes past the 256-byte M area) merged into one
  refused block; MW10 keeps reading 4097 on every pass.

Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:30:12 -04:00
Joseph Doherty 1d83cde6bc perf(s7): fail the rest of a pass fast once the handle is dead (R07:P1)
No read or write loop checked _plcDead between items: on a frozen-but-
established peer the first op blew its deadline and marked the handle dead,
and every remaining span / tag / write still went to the wire and could wait
its own deadline under _gate (a 20-span pass ~100 s), with Degraded and the
comms-loss watchdog's clock deferred until the pass ended.

- The span loop, the multi-var chunk loop, the per-tag loop and the write
  loop stamp BadCommunicationError without I/O once _plcDead is set.
- A multi-var chunk that dies on a transport loss (socket / IO / timeout /
  ConnectionError) marks the handle dead instead of falling back to one
  doomed per-tag read per member. The framing class is deliberately excluded
  there: snap7/S7.Net report a multi-var with one refused item as
  ReadData(WrongNumberReceivedBytes) over a healthy stream.
- Live gate via an in-test freezable TCP proxy (counts request frames, not
  seconds). Mutation shows S7.Net 0.20 already self-closes on a cancelled op,
  so the gate pins the end-to-end property; the driver guard itself is proven
  by the unit tests (an op that ignores its token keeps the socket open).

Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:26:14 -04:00
Joseph Doherty a1f20e78f9 fix(s7): a CPU refusal is per-tag Bad and counts as answered (R07:H4)
A deterministic PLC refusal (object does not exist, address out of range,
type inconsistent...) degraded driver health, and an all-refused driver (a
wrong DB number) sat Degraded with LastSuccessfulRead frozen, so the 90 s
comms-loss watchdog reconnected it forever against a reachable PLC.

- IsRefusal / IsAccessDenied classify over the whole exception chain. Live
  probe on the snap7 fixture: S7.Net's READ paths raise the item error as a
  BARE Exception ("Received error from PLC: ..."), its write paths as
  PlcException(WriteData). The old PlcException-only match missed the read
  shape entirely, so a real read access-denied was BadCommunicationError +
  Degraded instead of the Faulted PUT/GET alert; the Test Connect probe had
  the same blind spot.
- A refusal (read or write) is BadDeviceFailure with a once-per-tag Warning,
  no health write and no reopen; it counts as answered, so it advances
  LastSuccessfulRead and restores Healthy after a comms fault. An undecodable
  buffer (S7ValueRangeException) also counts as answered.
- A write batch the CPU answered without a failure advances
  LastSuccessfulRead and retires a Degraded the write side itself published.
- Tests that used ReadData as their generic "device fault" now use SendData
  so their Degraded leg is still exercised.

Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:20:51 -04:00
Joseph Doherty ecf1e86464 fix(s7): lifecycle gate + generation-stamped health and publishes (R07:H5)
Overlapping InitializeAsync calls (the actor's fire-and-forget init plus a
retry tick) could leak an opened PLC connection and orphan a probe loop: no
gate guarded the lifecycle, only _gate for I/O.

- _lifecycleGate (the Modbus pattern) serialises Initialize / Reinitialize /
  Shutdown / Dispose; teardown waits a bounded time, then tears down anyway.
- Every initialize and teardown starts a lifecycle generation. Health writes
  (init, read/write passes, poll errors, shutdown) and the init publish carry
  it and are dropped once it has moved on, so an abandoned init never
  publishes over a later shutdown and a shutdown's final write never clobbers
  a newer init. A superseded init disposes what it opened and throws.
- The init publish (options, tag tables, Plc, probe loop) happens under _gate;
  the tag tables are built fresh and swapped by one reference write instead of
  being cleared in place under live poll passes.
- Read/write passes re-check initialization under _gate, so a pass that waited
  out a teardown cannot reopen a connection on a shut-down driver.
- The semaphores are no longer disposed: Dispose can race a running shutdown.

Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:10:21 -04:00
Joseph Doherty 87a7414df7 fix(s7): refuse unservable tag shapes per tag at every gate (R07:H3, R07:U4)
The init-time tag guards THREW: one mis-authored tag (DB1.DBZ0, DB1.DBW0 typed
Float64, T5 typed Int32, a writable Bool array) faulted the whole driver and the
actor retried the same init every 10 s forever, darkening every tag on the PLC.
Neither the editor nor the deploy gate checked any of it.

- S7AddressParser moves to S7.Contracts (same namespace) and a new
  S7TagShapeRules there is the single authority on servable shapes.
- S7TagDefinitionFactory.FromTagConfig applies it, so the AdminUI editor, the
  deploy gate (Inspect, with the specific reason) and the driver init refuse
  the same tags. Init now skips a refused tag (ISkippedTagReporter) instead of
  throwing; the throwing RejectUnsupportedTagConfigs is gone.
- New rules on top of the old guards: a narrow type at the wrong access width
  (every read failed) and a Bool array not starting at bit 0 (U4: DB1.DBX0.3
  silently read bit 0 of bytes 0..n).
- AdminUI test fixtures that used addresses the driver could never serve
  (DB1.DBS0, a browse "SomeAddress", Int32/Float32 on DBW) now use real ones.

Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:04:19 -04:00
Joseph Doherty 3e0606af58 Merge lane E: script runtime safety + scripted alarms (#734)
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:03:54 -04:00
Joseph Doherty 0d367590db test(galaxy): isolate process-wide telemetry tests; bounded stream-cancel wait
GalaxyTelemetryTests (ActivityListener) and GatewayGalaxyDataWriterFailClosedTests
(MeterListener, filtered only by meter and instrument name) observe every Galaxy span or
measurement in the process. They now run in a collection with parallelization disabled
(F-FU6), because a parallel driver test, or its background probe seed, polluted their counts.
The stream-cancel assertion in GalaxyDriverShutdownTests goes back to a bounded wait: the
instantaneous IsCompleted check introduced in round 1 was racy.

Refs #735

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:47:34 -04:00
Joseph Doherty 3e60a925dc fix(galaxy): background probe seed; generation-checked registrations
Review fix round 2 for lane F:
- N1: the init platform seed no longer runs inline under the init token. Galaxy's Tier-A
  Initialize budget is 5 s, and a cold gateway DiscoverHierarchy can spend all of it, so the
  OperationCanceledException rethrow failed init, opened the Initialize breaker and cost a full
  rebuild per retry. InitializeAsync now only resolves the platform source (no network) and
  queues a background seed tied to a per-runtime CTS that the teardown cancels. A result that
  lands after its runtime was torn down is discarded.
- N2: the seed worker serves the runtime that is live when each pass STARTS, so a request made
  under a new runtime while a stale pass is in flight always gets a pass of its own.
- N3: SubscribeAsync and the subscribe-once read capture the runtime generation before
  SubscribeBulk and register only if it is unchanged, atomically with the teardown's registry
  Clear (_registryGate). On a mismatch they release the handles and fail the call. Re-subscribe
  Rebind uses the same gate, and the production rebuild clears the registry unconditionally.
- PerPlatformProbeWatcher re-checks its stop after the SubscribeBulk await, atomically with
  the record and publish. A pass that straddles StopAsync releases the handles it acquired
  instead of writing the probe entry back into a cleared registry.

Refs #735

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:47:34 -04:00
Joseph Doherty ef2eebe6b6 fix(scripting): review minors: configured limit in summaries, dispose gate/CTS, validator, docs (fix round 1)
- ScriptLogRateLimiter.LimitPerWindow. The ScriptLogTopicSink and
  VirtualTagActor summaries now print the configured limit, not
  DefaultLimitPerWindow. Tests assert "limit N/window" for a non-default
  N.
- CalculationDriver.Dispose cancels, then takes _evalGate (bounded 2 s)
  and disposes the gate and _evalCts. The pump and timer ticks enter the
  gate through TryEnterEvalGateAsync, which stops cleanly once the
  driver is disposed. Test: Dispose with a 6 s runaway run in flight
  returns promptly, disposes both, and a late trigger is harmless.
- ScriptedAlarmEngine captures _shutdownToken once and disposes
  _shutdownCts in Dispose when every drained task has completed. A task
  stuck past the grace leaves the CTS to the GC. Lifecycle tests assert
  the disposal.
- DraftValidator: CalculationNoEffectiveTrigger is skipped for a
  change-triggered tag whose scriptId does not resolve. That case is
  already CalculationScriptMissing or CalculationScriptNotFound, and
  there are no reads to count. Both existing tests now assert the
  absence (red before the change).
- docs/VirtualTags.md: System.Threading is denied as a whole namespace,
  with an allow-list; the type list is now accurate (Unsafe,
  RuntimeHelpers, and the ForbiddenMembers on System.Type); the resource
  limits section covers the run guard and the allocation budget.
  docs/ScriptEditor.md: accurate deny-list and a new "Runtime safety"
  section covering timeout, refusal, quarantine after 3 timeouts,
  allocation budget, lifting, and rate-limit summaries that appear only
  on the source's next entry after a burst then quiet.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:41:15 -04:00
Joseph Doherty 8a0acc4649 Merge master into remed/lane-F
Refs #735

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:29:15 -04:00
Joseph Doherty 77ca10aa37 test(galaxy): de-flake writer-lane and supervisor tests; align EffectiveTimeout doc
The writer concurrency fake parks on its release signal (the 300 ms delay could release the
gate early on a starved pool), the supervisor test's cross-thread hold flag is Volatile, and
the EffectiveTimeout doc now states the 1 s floor the code and tests implement.

Refs #735

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:29:11 -04:00
Joseph Doherty 3456756cd1 fix(galaxy): seed the probe set at init, refuse pumps mid-teardown, bound the close
Review fix round 1 for lane F:
- The ScanState probe watcher is seeded at InitializeAsync from a platform-only
  DiscoverHierarchy query (IGalaxyPlatformSource / GatewayGalaxyPlatformSource over the owned
  repository client) and re-seeded on every deploy-watcher rediscovery. The runtime never
  calls DiscoverAsync on a live driver, so per-platform host status was unreachable in
  production. A failed fetch logs a Warning and never fails init; re-seeds coalesce so a
  deploy during an in-flight pass still gets a pass that starts after it.
- EnsureEventPumpStarted refuses while the runtime is stopping, BEFORE reusing the live pump
  (that pump belongs to the dying subscriber), and the production rebuild disposes any stale
  pump before wiring the new subscriber.
- TeardownRuntimeAsync closes the MX session under the caller's token linked with a 5 s
  SessionCloseDeadline, so a blackholed gateway cannot hold DriverInstanceActor.PostStop for 30 s.
- A runtime generation counter, bumped by every teardown, is re-checked before each Rebind
  in ResubscribeAllAsync, so a replay-gap re-snapshot that straddles a teardown cannot
  resurrect handles into the cleared registry.

Refs #735

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:29:11 -04:00
Joseph Doherty 05a0e51fc1 fix(galaxy): GalaxyMxSession.CloseAsync(ct) bounds the gateway CloseSession
The SDK's DisposeAsync closes with no token, i.e. under the 30 s DefaultCallTimeout, so a
blackholed gateway parked the driver's teardown for the whole of it. CloseAsync(ct) runs the
close under the caller's token, drops the channel on a cancelled/failed close (the gateway
reaps the session on its idle lease) and leaves the session re-openable. A close followed by
the final dispose closes the gateway session once.

Refs #735

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:29:11 -04:00
Joseph Doherty 6aa5edaf30 fix(scripting): only timeouts are quarantine strikes; alarm Bad annotation once per bucket change (fix round 1 I1, I3)
- I1 ScriptRunGuard: a run refused because the previous one is still
  executing is a Bad publish plus otopcua.script.run_refused, and no longer
  a quarantine strike. Only a timeout (and an allocation breach) counts;
  a refusal neither adds to nor resets the timeout streak; a completed run
  (value or throw) resets it. On a 1 Hz trigger with a 2 s budget a single
  4 s overrun is one timeout plus two refusals and must not quarantine.
  Tests updated across the guard, the alarm engine, the Calculation
  evaluator and the VT evaluator, plus
  Refusals_neither_count_toward_nor_reset_the_timeout_streak.
- I3 ScriptedAlarmEngine: the quality bucket is tracked only after the
  predicate completes (or in the inputs-not-ready path), so the tracked
  bucket is the last one annotated. A refused or quarantined predicate
  used to re-track the input bucket Good before the attempt and then flip
  it Bad, emitting QualityChanged on every push. The run-guard tests now
  count emissions (exactly 1 across N pushes, refused and quarantined
  cases), with a healthy sibling's dispatch count as the positive control
  that every push was processed. Both were red before the fix.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:26:12 -04:00
Joseph Doherty 909b061d3a Merge branch 'master' into remed/lane-E 2026-10-22 10:48:41 -04:00
Joseph Doherty 4d3fc9c816 fix(runtime): restart-safe alarm host, mux last-value replay, VT log rate limit, Calculation remediation (E4)
- R02:H1 ScriptedAlarmHostActor gains a factory Props
  (Func<(upstream, engine)>) so every incarnation builds and owns its own
  engine; a supervision restart no longer re-creates the actor around a
  disposed engine. The legacy instance-taking Props stays source-compatible
  and is now restart-safe in the weaker sense (PreRestart marks the stop as
  a restart, PostStop then detaches instead of disposing). DriverHostActor
  still spawns through the legacy overload (not owned by this lane — F3).
- R02:H3 OnAlarmCommand runs every engine op under a 10 s token linked to
  the actor's lifetime (DefaultCommandTimeout / Props commandTimeout) and
  logs a Warning on timeout instead of suspending the mailbox on a stalled
  store.
- R02:L3 DependencyMuxTagUpstreamSource.RetainOnly(loaded dep-ref union),
  called after every successful load.
- R02:P6 VirtualTagActor's per-failure ScriptLogEntry is rate-limited per
  tag (ScriptLogRateLimiter, 20/min + one summary); the Bad publish and the
  metric are untouched.
- R07:H6 DependencyMuxActor retains the last (value, status, ts) per
  ever-registered ref (through unregisters) and replays them in one batch to
  a RegisterInterest(ReplayRetained: true) — VirtualTagActor, the Calculation
  mux adapter and the alarm host opt in; the historization recorder does not
  (a replay there would record a stale sample per deploy). CalculationDriver
  records inputs regardless of _running so a replay landing before
  InitializeAsync still satisfies the change-gate.
- R07:P4 CalculationEvaluator negative-caches compile failures by source
  hash (one Roslyn attempt + one Warning per source until redeploy); the
  driver's script-log entry fires on the Good→Bad transition or a change of
  reason, matching the once-per-transition Bad publish.
- R07:H8 array results dedup structurally.
- R07:L2 ShutdownAsync drops the compiled scripts (collectible ALCs).
- R07:U5 DraftValidator rule CalculationNoEffectiveTrigger: a tag with no
  timer whose change trigger is off or whose script has no literal
  ctx.GetTag read can never evaluate.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 10:27:49 -04:00
Joseph Doherty 6dedf5158f feat(galaxy): wire DiscoverPageSize and ProbeTimeoutSeconds; concurrent first-touch write lanes
Review 2026-10-21 G-5, G-6, G-8 ("wire them all").

- G-5: GatewayGalaxyHierarchySource now pages the DiscoverHierarchy RPC
  itself (DiscoverHierarchyRawAsync) at Repository.DiscoverPageSize. The
  mxaccessgw client's typed DiscoverHierarchyAsync overloads hard-code a
  5000-row page and DiscoverHierarchyOptions carries no page size, so the
  authored knob reached nothing; the raw request takes page_size on the
  wire, so it is honoured here (non-positive → 5000). The loop keeps the
  client's repeated-page-token guard.
- G-6: GalaxyDriverProbe reads ProbeTimeoutSeconds from the config and
  runs under min(caller budget, configured cap) — the knob can shorten a
  probe, never extend it past the host's budget. The TCP preflight now
  shares that deadline instead of hanging on the caller's token alone.
- G-8: GatewayGalaxyDataWriter runs a batch as one lane per distinct tag,
  concurrently and bounded at 8 (MaxConcurrentWriteLanes); same-tag
  writes keep their authored order inside one lane and results land at
  their request's index. Acks stay serial by design.
- GalaxyDriverForm: help text now says what the two knobs actually do.

Refs #735

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 06:41:47 -04:00
Joseph Doherty eb9269c337 feat(scripting): ScriptRunGuard quarantines runaway scripts across every seam (E1)
A timed-out script is abandoned, not stopped, and every seam re-ran it on the
next trigger, leaking one pool thread per trigger (R03:1.1, R05:2, R07:L1).
A shared ScriptRunGuard, keyed per script instance, now:

- refuses a run while that script's previous orphan is still executing
  (Bad "previous evaluation still running" + otopcua.script.run_refused);
- quarantines after 3 consecutive non-completions or an allocation-budget
  breach (sampled with GC.GetAllocatedBytesForCurrentThread; default 64 MB):
  no further dispatch, Bad quality, one Error, otopcua.script.quarantined,
  cleared on source change / redeploy / reset;
- starts the budget clock when the pool picks the run up, so starvation is
  no longer charged to the script (R07:P5), and cancels the evaluator token
  on timeout.

Wired into RoslynVirtualTagEvaluator, CalculationEvaluator (new async
EvaluateAsync; the driver's pump and timer ticks now await the run behind a
SemaphoreSlim gate) and ScriptedAlarmEngine (a non-completing predicate
holds state and annotates the condition BadInternalError). ScriptingOptions
(Scripting:MaxAllocBytesPerRun, Scripting:QuarantineAfterConsecutiveTimeouts)
carries the knobs; the Calculation driver config accepts the same two keys.

Tests: guard unit suite (incl. the 30-trigger runaway leaving one orphan with
a healthy sibling as positive control), per-seam refusal/quarantine/reset
tests. The S12 race test now uses one vtag id per loop: twelve concurrent
evaluations of ONE id is a shape production never produces and the guard
refuses by design.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 06:39:43 -04:00
Joseph Doherty 1b3169273d fix(galaxy): wire ScanState probing, single-sweep discovery, liveness stamp, dispatch-loop fault
Review 2026-10-21 G-4, G-7, G-11, G-10.

- G-4: PerPlatformProbeWatcher publishes its probe handles into the
  driver's SubscriptionRegistry under the reserved ProbeSubscriptionId
  (-1), so the EventPump's fan-out finally reaches the watcher — every
  ScanState event used to be dropped as "stale after unsubscribe" and
  per-platform host status never updated. ResubscribeAllAsync delegates
  the reserved entry to the watcher's new ResubscribeAsync, so the probe
  survives a reconnect; StopAsync removes the entry. Probe traffic is
  routed by the reserved handle and never reaches the public OnDataChange.
  The watcher is also built on the seam path (subscriber only), which is
  what makes the wiring testable without a gateway.
- G-7: GalaxyDiscoverer.DiscoverAsync returns the hierarchy it fetched and
  the driver selects its $WinPlatform/$AppEngine probe targets from that
  same sweep instead of asking the gateway for the whole galaxy twice.
- G-11: OnPumpDataChange stamps LastSuccessfulRead from inbound stream
  data, throttled (1 s default), so the comms-loss watchdog has honest
  liveness evidence under a Degraded supervisor.
- G-10: an EventPump dispatch-loop exit that is not a cancellation now
  reports a stream fault so the supervisor recreates the pump, instead of
  leaving a deaf pump reporting Healthy.

Refs #735

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 06:35:48 -04:00
Joseph Doherty 2d25c916b6 fix(galaxy): make ShutdownAsync a real runtime teardown so re-init rebuilds
GalaxyDriver.ShutdownAsync was a no-op: the MX session, both owned gRPC
channels, the EventPump, the alarm feed, the DeployWatcher, the probe
watcher and the reconnect supervisor were released only by DisposeAsync,
which the host never calls — one leaked gateway session per respawn,
removal and /raw browse, and a watchdog Shutdown→Initialize that neither
tore down nor rebuilt anything (review 2026-10-21 G-1, G-2, G-9, G-3).

- ShutdownAsync and DisposeAsync share one ordered TeardownRuntimeAsync
  (supervisor first, then deploy/probe watchers, pump, alarm feed,
  session, channels); owned seams are nulled so the next InitializeAsync
  rebuilds; injected seams survive a shutdown and drop only on the final
  dispose. Lifecycle calls are serialised behind a gate.
- A failed production connect releases its partial runtime (no orphaned
  client per watchdog retry) and lands Faulted before and after.
- StartDeployWatcherAsync stops the previous watcher before starting a
  replacement, and now starts on a production instance's FIRST
  InitializeAsync (the old guard returned whenever discovery had not run
  here, which on a runtime instance is always).
- ReconnectSupervisor releases each cycle's CancellationTokenSource when
  its loop exits and gains an awaitable StopAsync; PerPlatformProbeWatcher
  gains an awaitable StopAsync.
- EventPump treats any exception under cancellation as a clean stop, so a
  teardown never wakes the supervisor.
- Internal seams for tests: an IGalaxyDeployWatchSource ctor parameter and
  a session-open override forwarded to the owned GalaxyMxSession.

Refs #735

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 06:30:14 -04:00
Joseph Doherty 6669fae7e5 feat(historian): ServerHistorian:MaxRawValuesPerRead caps raw pages and backend reads
Review R08:1.1: an uncapped HistoryRead-Raw (NumValuesPerNode = 0) read a
tag's whole window into memory on every backend (SQL TOP(int.MaxValue),
QuestDB LIMIT, Gateway max_values = int.MaxValue + a second snapshot copy).

New ServerHistorian:MaxRawValuesPerRead (default 10 000; <= 0 unbounded with
a Validate() warning; 1 raised to 2). Each backend data source takes it,
reports it as IHistorianDataSource.MaxRawValuesPerRead (the Gateway: min
with a strict gateway's learned ceiling), so the node manager's existing
RawPageLimit paging serves N = 0 and N > cap as pages of at most the cap
with a continuation point. Independently, a backend raw read asking for 0
or more than the cap reads cap + 1 rows and is REFUSED
(HistoryReadLimitExceededException => BadTooManyOperations) when the window
holds more - never answered truncated, since the server's paging reads a
short answer as the last page. Bound through the Host registry, the
SqlServer/QuestDb providers and GatewayHistorian.CreateDataSource.

Tests: options (default/binding/warnings), provider binding, Gateway unit +
through a real SDK node manager (uncapped -> 999/998/998/605 + CPs), and a
conformance case for the SQL backends.

Refs #736

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 06:29:10 -04:00
Joseph Doherty eed7cc7d75 test: guarantee driver fixture cleanup without masking failures 2026-10-13 16:36:38 -04:00
Joseph Doherty 5310a7e07a Discard asserted probe-task return values without joining loops 2026-10-13 16:12:31 -04:00
Joseph Doherty cd50db136e docs: clarify S7 counter evidence and fixture limits 2026-10-13 11:34:59 -04:00
Joseph Doherty 8ff9f38bbd Make bootstrap cancellation test deterministic and deduplicate boundary cases 2026-10-13 09:56:37 -04:00
Joseph Doherty 109163621c fix(historian): preserve stable alarm delivery identities
v2-ci / build (pull_request) Successful in 5m52s
v2-ci / unit-tests (pull_request) Failing after 1h23m55s
2026-10-13 07:10:58 -04:00
Joseph Doherty 3ec6006f57 test(historian): cover concurrent gateway tag cache lookups
v2-ci / build (pull_request) Successful in 6m52s
v2-ci / unit-tests (pull_request) Failing after 3h12m20s
2026-10-13 05:21:46 -04:00
Joseph Doherty 5897764024 fix(historian): fail fast for missing tags and reduce gateway read cost
v2-ci / build (pull_request) Successful in 5m6s
v2-ci / unit-tests (pull_request) Failing after 29m54s
2026-10-13 04:31:52 -04:00
Joseph Doherty 97668d26d3 fix(historian): respect gateway ceilings and history value contracts
v2-ci / build (pull_request) Successful in 5m10s
v2-ci / unit-tests (pull_request) Failing after 28m34s
2026-10-13 03:51:04 -04:00
Joseph Doherty de8bc7a12c fix(historian): #694 R2 cap the crowding re-read room at MaxTieClusterOverfetch
The #687/F4 crowding re-read doubled its room up to 8 re-reads with no cap, so a pathological single-ms
cluster on a streaming gateway was streamed several times over for one page. The room is now capped at
ServerHistorian:MaxTieClusterOverfetch (plumbed into GatewayHistorianDataSource as maxPreWindowRows,
default 65536); past it, or once a read has already seen more, the read is BadTooManyOperations with
PreWindowRows set.
2026-10-13 01:53:14 -04:00
Joseph Doherty 3c3513ea3e fix(historian): #694 page raw reads at a strict gateway's learned ceiling; opt-in EventReadHorizon
Item 1: IHistorianDataSource.MaxRawValuesPerRead (Gateway: learned ceiling - 16 = L; 0 elsewhere, guard-tested).
RawPageLimit plans every raw page on top of #692's lookahead: with L > 0 the read (page P + boundary ties k
+ lookahead) is <= L, P = min(N, L - k - 1) (uncapped: L - k - 1); no room => straight to the tie-cluster
over-fetch (never an uncapped or underflowing request). One re-plan + re-read when the read taught a new
limit or was refused for crowding pre-window rows (HistoryReadLimitExceededException.PreWindowRows): the
page shrinks by them. Over-fetch bound min(MaxTieClusterOverfetch, L - 1); slice size never 0.
Review fixes: F1 a window starting at/before the epoch counts AVEVA's synthetic row as pre-window (a
ceiling-truncated read was reported complete); F2 the page path disables ReverseRawReader's own re-run
(cold end-only ceiling 20/N=3000 cost 3,023 reads, now <= 40); F3 crowded look-back re-read around, not
refused; F4 the #687 crowding re-read room at least doubles (up to 8 re-reads), so a cluster of hundreds
just before a resume point no longer fails on a default gateway; a crowding refusal that leaves no room
is BadTooManyOperations, never a tick-by-tick cursor.

Item 2: ServerHistorian:EventReadHorizon (default 00:00:00 = exact, unchanged). When set, every fresh
HistoryReadEvents window's earlier bound is raised to now - horizon (both directions, all backends).
Lossy by design; documented.

Item 3 (native TimeAverage/Total re-check) stays blocked on historiangw#27.
2026-10-13 01:39:32 -04:00
Joseph Doherty 2609c5462e fix(historian): #693 re-review — AtTime read cap 64 + 16 per time (bursty tags need ~6)
A time inside a gap of a bursty tag costs a 64-row jump read landing in the next
burst plus a bisection back across the gap (~6 reads), so the 64 + 4/time cap
refused a 1 h/day 1 Hz tag asked at noon on 30/100/300 consecutive days
(186/606/1,806 reads) that AVEVA's own AtTime served. The cap is a runaway guard
(HistoryReadDeadline bounds wall clock): now 64 + 16 per distinct time.
Regression tests for x30/x100/x300 (each <= 7 reads a time, values checked).
Docs: DateTime-hinted nodes are stepped but keep the gateway's Double (the
Gateway never historizes DateTime nodes; the SQL backends return DateTime).
2026-10-13 01:17:51 -04:00
Joseph Doherty 68a1f31397 fix(historian): #693 review — bisecting walk-back, small jump reads, read cap, DateTime/NaN hints
H1: the walk-back reset its width after a full segment and discarded a full
whole-remainder read, so a dense tag that stopped reporting weeks ago gave up
after 65 reads (BadTooManyOperations). It now gallops (x4, whole-remainder read
after two empties) and then BISECTS once any stored row is known below — a full
segment's (incl. a full whole-remainder read's) last row, or an earlier window
read's last row: (mid, hi] empty => hi = mid; full => known = its last row;
complete with rows => done; one density-aimed segment after a full read until an
aimed segment comes back empty; below 2 ms the whole stretch from the known row
(never a 100 ns step). Stopped 1 h..365 d with 5 y history: 6-18 reads at
1/min, 21-25 at 1 Hz, 25-31 at 10 Hz.
M1: a jump read asks for 64 rows (1,000 times over 10 y: ~66k rows, was ~1M).
L1: per-request read cap 64 + 4 x distinct times with a clear message; a strict
ceiling below 4 rows is refused naming the ceiling.
L2: DateTime hints are stepped. L3: under an integer hint a NaN/inf or
out-of-Int64-range value is unusable, never saturated Good.
L5: conformance Int64 AtTime asserts the type. L4: docs name the backend
differences. Nit: the window read end is clamped to now + 1 day.

Reviewer harnesses (Scratch693Fuzz/Cost, not committed): 0 differential diffs
over 2,400 cases.
2026-10-13 01:09:54 -04:00
Joseph Doherty 0d249f3ee9 fix(historian): #693 AtTime type hint — Boolean nodes stepped, integer nodes rounded to their type
Review follow-up: on the Gateway every value is a Double (AVEVA stores a Boolean
as a 0/1 Int2), so the raw-evaluated AtTime interpolated a Boolean node to 0.5.

- IHistorianDataSource gains a default-interface overload
  ReadAtTimeAsync(fullReference, timestamps, TypeCode? valueType, ct) that
  forwards to the existing one (SqlServer/QuestDB/Null/fakes unchanged).
- OtOpcUaNodeManager.HistoryReadAtTime passes the node's scalar DataType
  (AtTimeValueType: built-in type -> TypeCode; arrays/other types => null);
  Raw and UNS NodeIds alike.
- GatewayAtTimeReader converts each raw row to the hinted kind BEFORE the shared
  AtTimeEvaluator runs (Boolean = value != 0 => stepped; integers => Int64 =>
  interpolated, rounded half away from zero, returned as the node's integer
  type; floats Double), so the evaluator's own type branch decides.
- AtTimeEvaluator boxed every interpolated Int64 as a Double (`cond ? (long)x :
  v` widens to double); its "keeping its type" test passed because Shouldly
  ShouldBe compares numbers across types. Fixed (affects SqlServer/QuestDB too)
  and pinned with ShouldBeOfType.
2026-10-13 00:52:03 -04:00
Joseph Doherty 37390139fe fix(historian): #693 Gateway AtTime evaluated from raw reads with the shared AtTimeEvaluator
Gateway HistoryRead-AtTime passed AVEVA's own interpolation through: live it
answered the previous value as Good at a stored NULL's own time, null + Bad at
a Good sample right after a NULL, a drifted 99.99999999944 for a stored 100,
and no Interpolated bit. It is now served from raw gateway reads and evaluated
with Sql.Common's AtTimeEvaluator, as the SQL backends do (Part 11 §6.5.4).

GatewayAtTimeReader: one <=1,024-row forward window read [first-1ms, last+1ms]
for the batch, a walk-back (density-seeded, x4 growth, whole-remainder shortcut,
bisects dense history) for the first time's prev, and an 18-row probe for the
last time's next; truncated window reads continue or jump with a density-sized
margin. All bounds whole ms; a row counts only strictly inside its request
(AVEVA's boundary row never a sample); Bad rows value-less (#690); never past
now + 1 day; strict-gateway ceiling learned (#691.3) without re-probing.
10 dense times = 1 read (exact) / 3 (interpolated); 10 hourly = 12.

Kill switch ServerHistorian:GatewayAtTimeFromRaw (default true; false = the
old AVEVA passthrough). Known limit: the wire carries no data type, so numeric
tags interpolate as Double (Boolean/integer nodes are not stepped/rounded as on
the SQL backends).
2026-10-13 00:40:38 -04:00
Joseph Doherty 934909b430 fix(historian): #691 review — clamp Gateway at-or-after read, GoodNoData when nothing exists, HonorReturnBounds kill switch
1. The at-or-after bound read on a forward-only backend (Gateway) ends at
   now + ReverseRawReader.LookAhead instead of DateTime.MaxValue (the gateway
   only checks start <= end, so a year-9999 end reached AVEVA); a bound beyond
   the horizon is not found without a read. SqlServer/QuestDB keep MaxValue:
   they bind it safely and may hold samples further ahead. The Gateway fake now
   refuses far-future ends, so the missing-end-bound test is no longer vacuous.
3. No data and no bound found (whole read empty) => GoodNoData, no values —
   the pre-bounds answer (6.5.3.2: success only if one or both bounds exist).
   A one-value page whose start bound is missing first checks there is data or
   a found end bound.
4. ServerHistorian:HonorReturnBounds (default true); false ignores ReturnBounds
   as before #691, including the modified-read Bad_InvalidArgument.
2026-10-12 17:52:34 -04:00
Joseph Doherty 92aab7282c test(historian): #691 Gateway bounding values over the real source and an AVEVA-shaped wire
The start bound is the stored prior sample at its own time (walked back), never
the synthetic boundary row stamped at the query start; a stored NULL is a Bad
bound; reverse end bound walks back too.
2026-10-12 17:52:34 -04:00
Joseph Doherty 60febbf2dc feat(historian): #691 HistoryRead-Raw ReturnBounds — Part 11 bounding values on every backend
The node manager composes the start/end bounds from each backend's existing raw
reads (one authority, HistoryBounds): at-or-before = a capped reverse read
(native, or ReverseRawReader's walk-back on a forward-only backend — never
AVEVA's synthetic boundary row), at-or-after = a capped forward read. Bounds
count toward NumValuesPerNode, the start bound leads the first page, the end
bound ends the last (carried in the continuation point). Missing bound =
Bad_BoundNotFound (null, at the bound time; one-sided reads ±1 s from the
previous value, Table 1 footnotes a/b). A modified read with ReturnBounds is
Bad_InvalidArgument (Part 11 6.5.3.3).

The .NET SDK's ReadRawModifiedDetails defaults ReturnBounds to TRUE; the
existing tests built details without setting it and now set it false.
Oracle: every row of Part 11 Table 1 over three backend shapes, plus paging
concatenation, ties, Bad bounds, microsecond truncation; conformance pins the
lookup primitives on SqlServer + QuestDB.
2026-10-12 17:52:34 -04:00
Joseph Doherty ccda27d220 fix(historian): #691.4 review — uncapped Gateway events reads no longer pre-size to int.MaxValue
GatewayHistorianDataSource.ReadEventsAsync sized its result list to
maxEvents, which is int.MaxValue for NumValuesPerNode = 0: every
uncapped Gateway events read (forward on master, and the new walked
reverse one) threw 'Array dimensions exceeded' and counted as a backend
failure. Capacity is bounded at 1024. The events walk delegate moved to
ReverseEventsReader so it is tested over the real Gateway source
(forward uncapped, reverse uncapped, reverse capped).
2026-10-12 17:20:41 -04:00
Joseph Doherty d277f34a96 fix(historian): #691.4 walk reverse events reads back on forward-only backends (Gateway)
A reverse or end-only capped events read on a backend without
SupportsReverseEvents (Gateway, Null) was refused
BadHistoryOperationUnsupported (explicit reverse) or answered with the
OLDEST N ascending (end-only, #675). It is now served newest-first by
the same ReverseWalk as raw reads: page-sized ms-aligned segments,
never answered from a read the source flagged truncated, ties sorted by
EventId (the gateway orders by event time only - the fake shuffles
them per call), one extra event walked to signal 'more', uncapped = one
forward read reversed, and the width + proven-empty stretch carried in
the events cursor. The oversized-cluster over-fetch keeps exactly the
events at T in the same order. A tie cluster over the budget is
BadTooManyOperations. Docs note the gateway's EventReadMaxRows must be
unlimited (it truncates silently).
2026-10-12 17:19:05 -04:00
Joseph Doherty 830b47f624 fix(historian): #691.2 review — forward native TimeAverage/Total on the SQL grid: clipped latest interval read over its exact span, Partial, interval clamped to the window 2026-10-12 16:55:01 -04:00
Joseph Doherty 7b86059daf fix(historian): #691.3 review — remember a strict gateway's ceiling per data source; re-probe once when a bounded read comes back full 2026-10-12 16:50:32 -04:00
Joseph Doherty ab5030174a fix(historian): #691.3 review — a ceiling-bound per-sample read names the gateway ceiling, not the cap 2026-10-12 16:47:57 -04:00
Joseph Doherty 0e47e887de fix(historian): #691.2 serve reverse native TimeAverage/Total on Gateway via forward reads on the later-anchored #677 grid 2026-10-12 16:17:05 -04:00
Joseph Doherty dbffb6bdb4 fix(historian): #691.3 strict-ceiling gateway: re-ask once at the named ceiling, never answer a truncated read 2026-10-12 16:13:14 -04:00
Joseph Doherty 39552e15b9 fix(historian): #690 Gateway raw/AtTime Bad rows carry no value (a stored NULL was value 0) 2026-10-12 16:08:54 -04:00
Joseph Doherty a3ee917fb4 fix(historian): #687 re-review — a row at/before the Unix epoch is never a stored sample
With StartTime at or before the epoch, RequestStartFor has no margin left, so
AVEVA's synthetic no-data/boundary row is stamped exactly at StartTime and was
kept: raw reads returned a fabricated Bad sample at 1970-01-01 and the per-sample
aggregates put it in bucket 0 (Start/End fabricated, Min/Max status Uncertain).
IsWindowSample and the aggregate loop now drop any row with t <= ProbeFloor
(RawAggregateReader.IsAfterFloor), matching the #686 walk-back's assumption.
2026-10-12 15:47:39 -04:00
Joseph Doherty 8114f13a28 fix(historian): #687 review — one bounded re-read instead of failing, raw budget unclamped, exclusive forward end
- M1/M2: when the 1 ms pre-window margin (boundary row + stored samples, e.g. a
  >16-sample tie cluster at start-1ms / lastTs-1ms) uses up the cap + 16 budget,
  re-read ONCE asking for cap + m + 16 (m = pre-window rows seen); fail
  BadTooManyOperations only if the re-read is still short because of them. The
  raw budget is no longer clamped at the gateway default ceiling (AVEVA always
  emits the boundary row, so page sizes 999,985-1,000,000 always came back
  short); the #688 clamp stays on the per-sample aggregate path only.
- Merge trap: NumValuesPerNode 0 => int.MaxValue, never through the clamp.
- L3: the forward end is exclusive ([start, end), the IHistorianDataSource
  contract); a point read (start == end, the tie-cluster over-fetch) inclusive.
- RequestStartFor never goes before the Unix epoch (#686's walk-back floor).
- L4 (docs): an Uncertain native row for an all-NULL interval is unverified live.
2026-10-12 15:19:34 -04:00
Joseph Doherty 6796ba4126 fix(historian): #688 clamp the Gateway per-sample row budget at the gateway's default ceiling
The default MaxTimeWeightedRawRows (1,000,000) + 18 exceeded the gateway's
default MaxValuesCeiling (1,000,000), so with AllowStreamingBeyondCeiling=false
every Gateway per-sample aggregate read was refused. The allowance is now clamped
at 1,000,000 while the cap is at or under it (RawAggregateReader.
ClampToGatewayCeiling); a cap above it keeps its allowance. Raw reads are not
clamped (rebased onto #686).
2026-10-12 15:15:35 -04:00