Commit Graph

10 Commits

Author SHA1 Message Date
Joseph Doherty ff055ebd79 fix(s7): numeric TSAP loads in form, shared TSAP conflict error, Test Connect read detects PUT/GET disabled, pin Int32 ms rounding (#632 #638)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:38:49 -04:00
Joseph Doherty 34c52defb3 feat(s7): STRING/WSTRING/CHAR/WCHAR and DTL/DATE/TOD/TIME/S5TIME codecs, TSAP/connection-type override, negotiated PDU surfaced (#632 #288 #289 #294 #295)
New S7DataType members WString/Char/WChar/Dtl/Date/Tod/Time/S5Time mapped onto existing
DriverDataType (String / DateTime / Int32 ms); writes refuse out-of-range with BadOutOfRange.
Optional localTsap/remoteTsap/connectionType through options, factory JSON, probe and AdminUI form.
NegotiatedPduSize snapshotted at connect and exposed via GetDiagnostics (DriverHealth has no bag).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:31:44 -04:00
Joseph Doherty acb3772426 fix(s7): validate span-read options at parse time; document the over-PDU degradation 2026-08-17 03:45:14 -04:00
Joseph Doherty 39f67a0fce perf(s7): span-grouped reads — one PDU per contiguous block instead of one per tag 2026-08-16 04:15:37 -04:00
Joseph Doherty 1e26b9ab58 v3(s7): apply Modbus RawTags exemplar to the S7 driver
Rename S7EquipmentTagParser -> S7TagDefinitionFactory; TryParse(reference)
-> FromTagConfig(tagConfig, rawPath, out def) (drops the leading-{ heuristic,
keys the def by RawPath, adds inverse ToTagConfig). Replace S7DriverOptions.Tags
(pre-declared S7TagDefinition list) with RawTags (IReadOnlyList<RawTagEntry>);
the driver builds its RawPath->def table from RawTags at Initialize via the
factory (skip+log on miss), resolver is byName-only, DiscoverAsync + init guards
+ address pre-parse now run off that table. Factory retires the pre-declared DTO
tag path (RawTags binding only). Cli BuildOptions serialises typed defs to
RawTagEntry. Tests migrated to a S7RawTags helper + FromTagConfig; parser test
files renamed. Coordinator's EquipmentTagConfigInspector S7 rename left to Wave-B
coordinator; Driver.S7.IntegrationTests (Docker-gated) left red per scope.

Driver.S7 + Cli build green; Driver.S7.Tests 264/264, S7.Cli.Tests 49/49.
2026-07-15 20:11:04 -04:00
Joseph Doherty 9cad9ed0fc docs(xmldoc): fill missing XML docs + strip tracking-ID comments across src
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
2026-07-07 12:38:39 -04:00
Joseph Doherty 5d01271f03 review(Driver.S7.Contracts): first review; gate stringLength check to String type
First review at 7286d320. -002 (Low): stringLength range check now only fires for
S7DataType.String (was rejecting valid non-String equipment-tag blobs). -001 ArrayCount=1
doc fix. -003 (driver-specs.md CpuType omissions) deferred. Consuming Driver.S7.Tests green.
2026-06-19 12:22:53 -04:00
Joseph Doherty a82c22c645 feat(s7): 1-D array block read + decode loop + IsArray discovery 2026-06-16 21:54:50 -04:00
Joseph Doherty f2f6eeb74e feat(drivers): expose ProbeTimeoutSeconds on every driver Options class
Adds a uniform [Range(1, 60)] ProbeTimeoutSeconds property to all 9
driver Options classes (Modbus 5s, AbCip 5s, AbLegacy 5s, S7 5s,
TwinCAT 10s, FOCAS 10s, OpcUaClient 15s, Galaxy 30s, Historian 15s).
Powers the AdminUI Test Connect button (Phase 7 of the plan).
2026-05-28 09:21:50 -04:00
Joseph Doherty 9f62f2c242 refactor(driver-s7): extract S7DriverOptions to .Contracts with parallel CpuType enum
Introduces Driver.S7.Contracts (dependency-free POCO project) and moves
S7DriverOptions / S7ProbeOptions / S7TagDefinition / S7DataType into it.
Adds S7CpuType enum mirroring S7.Net.CpuType exactly (7 values with
explicit integer codes). Runtime S7CpuTypeMap bridges S7CpuType →
S7.Net.CpuType at the single Plc construction site in S7Driver.InitializeAsync.
S7DriverFactoryExtensions and S7CommandBase updated to use S7CpuType; test
files updated to match (S7_1500Profile, S7DriverScaffoldTests). AdminUI can
now reference Driver.S7.Contracts without pulling in S7netplus.
2026-05-28 09:08:27 -04:00