Commit Graph

2096 Commits

Author SHA1 Message Date
Joseph Doherty d613575f32 merge: libplctag empty-path fix (null Path for an empty CIP route) 2026-10-07 19:06:36 -04:00
Joseph Doherty b8ebafc642 feat(adminui): Transport dropdown on AbCip/AbLegacy driver forms (live-verified on docker-dev)
- AbCip/AbLegacy driver forms gain a Transport InputSelect; FromOptions/ToOptions now carry
  Transport, so saving any other field no longer silently reverts Native to libplctag.
- Both drivers log the constructed transport once per init.
- AbCip factory now takes the host ILoggerFactory (it ran on NullLogger in production, hiding
  every AbCip log line); DriverFactoryBootstrap passes it.
- Gate results: AdminUI /run (T19) native, inverted (dead port) and libplctag legs.
2026-10-07 19:05:50 -04:00
Joseph Doherty afe6850f3d fix(abcip,ablegacy): pass a null libplctag path for an empty CIP route (Micro800 / unrouted MicroLogix)
The libplctag adapters assigned Tag.Path straight from the device's parsed
CipPath. A device address with no route (ab://host:44818/ - the normal
Micro800 form, and a MicroLogix with no route) parses to "", and libplctag
rejects an empty path attribute with ErrorBadData; omitting the attribute
(null) is what it accepts. So Micro800 could not connect on the default
libplctag transport.

This predates the native transport work and exists on master.

Add an internal LibplctagPath.Normalize helper per driver project (blank ->
null) and route all four Tag constructions through it (AbCip tag runtime,
symbol-list enumerator, template reader; AbLegacy tag runtime). The runtime
tag construction is extracted to an internal BuildTag so tests can inspect
Tag.Path without connecting. Tests fail with Normalize reverted to identity.
Update the Micro800 smoke-test comment: both transports are expected to pass.
2026-10-07 19:05:43 -04:00
Joseph Doherty 1d6501f427 feat(ab-transport): process-wide open-attempt budget so the differential never retries an open (Task 18 review r1) 2026-10-07 18:10:25 -04:00
Joseph Doherty 0e20a8e5a9 test(abcip): read-only differential harness comparing native and libplctag on one target 2026-10-07 17:58:47 -04:00
Joseph Doherty 2171fc8ce3 fix(ablegacy): PCCC requestor id is libplctag's captured identity (found by Task 17 slc500)
ab_server answers every Execute PCCC with a fixed requestor id (pccc.c
PCCC_RESP_PREFIX: 07 3D F3 45 43 50 21) instead of echoing the request's, so
the R14-3 echo check rejected every native reply sent under the 0x1337 CIP
originator identity as BadReply. The pooled runtime now sends libplctag's
identity (PcccServices.RequestorVendor/RequestorSerial), which passes the echo
check against ab_server and against a real controller that echoes. Pinned by a
FakeEipServer round trip that answers with ab_server's fixed prefix.
2026-10-07 17:31:45 -04:00
Joseph Doherty 82d011c7a8 fix(ab-transport): RegisterSession carries a zero sender context (found by Task 17 controllogix)
ab_server's RegisterSession sanity check rejects any non-zero sender context
with encapsulation status 1 and a header-only reply, so every native session
against the simulator failed with BadCommunicationError. libplctag sends zero
(logix-register-session.hex); the codec test now matches that capture byte for
byte instead of excluding the context, and a client test pins the zero on the wire.
2026-10-07 17:20:06 -04:00
Joseph Doherty 45f6e1793f feat(abcip): Transport option selects native or libplctag across driver, probe and CLI 2026-10-07 17:13:37 -04:00
Joseph Doherty b2b9aa04ed fix(abcip): Task 13 review r1 - bounded listing pager, exclusive large reads, template bound, safe lease release 2026-10-07 17:07:05 -04:00
Joseph Doherty 78e60a5a75 feat(abcip): native symbol listing and template reads feeding the unchanged decoders 2026-10-07 17:01:40 -04:00
Joseph Doherty f2f1e4280c merge: Task 12 — native AbCip tag runtime, factory and device mapping 2026-10-07 16:58:37 -04:00
Joseph Doherty 5fd9ff941e feat(ablegacy): Transport option selects native or libplctag across driver, probe and CLI 2026-10-07 16:57:20 -04:00
Joseph Doherty e2e441d45e fix(abcip): native runtime write guards, same-width integer exemption, deferred path encoding (Task 12 review r1) 2026-10-07 16:56:30 -04:00
Joseph Doherty f2377251af merge: Task 14 — native AbLegacy tag runtime + factory 2026-10-07 16:54:40 -04:00
Joseph Doherty b249c15c1a fix(ablegacy): refuse status-bit writes, decode status bits as 0/1, reject over-long replies, global TNS 2026-10-07 16:54:18 -04:00
Joseph Doherty 33dbd342e5 fix(ab-transport): trim-only CIP path canonicalisation, observe abandoned shared opens, no Forward Open after dispose during connect 2026-10-07 16:49:19 -04:00
Joseph Doherty 25cc836865 feat(abcip): native tag runtime over the managed CIP transport, with returned-type checking 2026-10-07 16:47:48 -04:00
Joseph Doherty c31e6deebf feat(ablegacy): native PCCC tag runtime over the managed transport 2026-10-07 16:45:50 -04:00
Joseph Doherty a251954bf7 fix(ab-transport): harden Task 9 pool and connection (close chaining, uncancellable shared open, monotonic throttle, canonical CIP path, internal ctors, shared-pool logger) 2026-10-07 16:45:26 -04:00
Joseph Doherty b82fffd269 feat(ab-transport): per-device connection with routing modes, shared scheduler, keep-alive and Forward Open throttle 2026-10-07 16:35:11 -04:00
Joseph Doherty ba73f48f9c merge: Task 10 — RequestScheduler (MSP coalescing) + LogixTagClient fragment loops 2026-10-07 16:23:08 -04:00
Joseph Doherty 5211975067 fix(ab-transport): harden Task 10 scheduler and tag client (dispose faults, pump guard, read cap, write validation, 8-byte wide-struct alignment) 2026-10-07 16:22:40 -04:00
Joseph Doherty 1c7fd5d5de feat(ab-transport): MSP-coalescing request scheduler and fragmented Logix read/write 2026-10-07 16:15:05 -04:00
Joseph Doherty 2f9c7eff58 merge: Task 5 — EtherNet/IP encapsulation codec + single-flight client 2026-10-07 16:14:02 -04:00
Joseph Doherty 4c1c362b0e feat(ab-transport): EtherNet/IP encapsulation codec and single-flight session client 2026-10-07 16:09:06 -04:00
Joseph Doherty 7c81844be5 merge: Task 8 — PCCC codec (Execute PCCC, SLC typed, PLC-5 range read) 2026-10-07 16:07:32 -04:00
Joseph Doherty 5eb018937b fix(ab-transport): PCCC review r1 - UA bit, bit limits, stricter ParseReply, non-const verified flags 2026-10-07 16:07:13 -04:00
Joseph Doherty 6d16765804 fix(ab-transport): harden Task 7 codecs (read status, 32-bit start instance, empty-More, size range) 2026-10-07 16:06:49 -04:00
Joseph Doherty 13d631d856 feat(ab-transport): PCCC Execute-PCCC codec for SLC/MicroLogix typed logical and PLC-5 range read 2026-10-07 16:03:43 -04:00
Joseph Doherty 5f86b370f7 feat(ab-transport): Connection Manager, MSP, Logix read/write, symbol and template service codecs 2026-10-07 16:03:41 -04:00
Joseph Doherty d602a08925 merge: Task 6 — CIP path encoding + Logix type codes 2026-10-07 15:46:31 -04:00
Joseph Doherty 0d2f27bb1d merge: Task 3 — AbLegacy seam decoupled from libplctag types 2026-10-07 15:46:31 -04:00
Joseph Doherty 10c909cbc2 fix(abcip): translate decode/encode-time libplctag exceptions; doc and probe-test cleanups 2026-10-07 15:44:02 -04:00
Joseph Doherty a57d61c484 refactor(abcip): confine libplctag to its adapters behind AbStatus/AbTransportException 2026-10-07 15:40:07 -04:00
Joseph Doherty 1affb4b613 refactor(ablegacy): confine libplctag to its adapter behind AbStatus/AbTransportException 2026-10-07 15:39:01 -04:00
Joseph Doherty f2f1ec2585 feat(ab-transport): CIP route/symbolic path encoders and Logix type codes 2026-10-07 15:38:04 -04:00
Joseph Doherty a0897fda96 feat(ab-transport): project skeleton with AbStatus, CIP reply parsing and the ICipChannel seam 2026-10-07 15:34:34 -04:00
Joseph Doherty 9dbaa6d758 Merge TwinCAT fixes ported from ignitionoee + live-validated on the Elma PLCs
v2-ci / build (push) Successful in 4m41s
v2-ci / unit-tests (push) Failing after 16m28s
2026-10-07 14:28:01 -04:00
Joseph Doherty 8060cfd2a5 fix(twincat): size strings by the resolved type and refuse VAR_IN_OUT references (live TC2 gate)
Found by the read-only live gate against the TwinCAT 2.11 Elma cleaners
Z33856 / Z33733:

- The Beckhoff library reports a TC2 dotted MEMBER symbol's ByteSize as if the
  PLC's byte count were a bit count (STRING(80) -> 11, INT -> 1, UDINT -> 1)
  while DataType.ByteSize is right (81/2/4, raw SYM_INFOBYNAMEEX says 81). The
  previous commit's typeof(byte[]) read sliced by the symbol size, so
  .OPC_MACHINEDATA.PROCESSSTATUS read "ready for o" at Good; the notification
  width check would also have refused every numeric member. The shape now takes
  the resolved type's size, and string reads go by index group/offset (or a
  fresh handle for 0xF005) at that width.
- P_INITINPUT_ACTION.SLOTID is "STRING(20) (VAR_IN_OUT)" - a 4-byte reference -
  but resolves to a plain STRING(20); a String tag read 21 bytes at the pointer
  as text at Good. The symbol's own VAR_IN_OUT marker now classifies it
  NonScalar -> BadTypeMismatch.
2026-10-07 14:27:22 -04:00
Joseph Doherty 6cc40963b4 Merge AbCip fixes found against real CompactLogix presses 2026-10-07 14:17:58 -04:00
Joseph Doherty e3d6b76ede fix(abcip): a scalar read whose width disagrees with its authored type is BadTypeMismatch
libplctag decodes whatever bytes the controller returns as the authored type and never
checks the CIP type code. Live read-only check on a production press: WW_ActualVacuum is a
REAL (L5X + the controller's symbol table agree) but the legacy Kepware export in the
ignitionoee repo types it Short; read as INT it returned Good -17346 while the real value
was 5.37. A scalar atomic read (not an array, not a bit-in-DINT) whose buffer size is not
the authored type's width now reads BadTypeMismatch with a warning naming both. Widths
observed live: SINT/BOOL 1, INT 2, DINT/REAL 4, LINT 8. IAbCipTagRuntime.GetSize() is a
default-interface member (-1 = unknown, never checked). Same-width mismatches (DINT vs
REAL) stay undetectable without the type code libplctag strips.
2026-10-07 14:15:19 -04:00
Joseph Doherty 68cf3ae8b7 fix(abcip): stride user-string arrays by the read buffer, not the built-in STRING size
Live read-only check against a production CompactLogix press: Program:UN01_Press._ModeNames
(STR0016[32], 4 elements requested) returned an 80-byte buffer with libplctag.NET 1.5.2's
ElementSize unset. The driver fell back to the static 88-byte STRING stride, read element
1 past the buffer, and the whole read failed (ErrorOutOfBounds -> BadCommunicationError).
When the buffer divides evenly by the element count, that quotient is now the stride;
the read returns [undefined, Production, Maintenance, Manual] as the controller holds.
2026-10-07 14:11:08 -04:00
Joseph Doherty 0ca56cb1f6 fix(abcip): an unknown tag no longer throttles its whole device or reads as a comms error
Live read-only check against a production CompactLogix press: with one nonexistent tag
first in the read list, libplctag's create threw LibPlcTagException("ErrorNotFound"); the
driver counted it as a failed Forward-Open, opened the device's 05/STAB-8 connect-backoff
window, and every other cold tag on the device - all real (WW_InCycle, WW_ActualPress,
WW_WorkOrderNum) - read BadCommunicationError. In steady polling the bad tag re-opens
the window each attempt, so siblings ordered after it may never connect.

- A create that fails with a "controller answered" status (NotFound/NoMatch/BadDevice,
  the probe's existing reachable classification) records backoff SUCCESS, not failure.
  Genuine connection failures still open the window (falsification control test).
- Read exceptions map through the libplctag Status they carry: unknown tag ->
  BadNodeIdUnknown, decode past the buffer -> BadOutOfRange, timeout -> BadTimeout,
  instead of a blanket BadCommunicationError. One status-name parser
  (AbCipStatusMapper.TryGetStatus) now serves both the read path and the probe.
2026-10-07 14:09:43 -04:00
Joseph Doherty 26b512adba fix(focas): a missing O-number or refused program sub-read goes Bad, not a Good 0
WireFocasClient.GetProgramInfoAsync defaulted every field the CNC did not report:
ONumber ?? 0 when the cnc_exeprgname2 payload was too short to carry it, and
Name '' / BlockCount 0 / Mode 0 when the sub-read was refused. 0 is a genuine
O-number (a 31i reports 0 for a path-executed program -- live Z-34184), a
genuine block count, and Mode 0 is MDI, a real operating mode.

FocasProgramInfo fields are now nullable; MapProgramInfo leaves unreported
fields null and the fixed tree publishes them BadNoData while the bundle's
other fields stay Good.

Ported from the sister ignitionoee FOCAS driver (101a3b1, 2026-08-12).
2026-10-07 14:08:26 -04:00
Joseph Doherty a0a024c80b fix(abcip): accept module-defined I/O tag paths (Local:1:I.Data, ABB_OmniCore:I.X)
Live read-only check: a production CompactLogix lists the module tag ABB_OmniCore:I in
@tags and libplctag reads ABB_OmniCore:I.ConnectionFaulted without complaint, but the
driver refused the path as malformed (identifier rule had no colon) and reported the
tag BadCommunicationError. Colon-separated identifier/slot parts are now legal in the
controller-scope base segment only (never past it, never under Program: scope).
2026-10-07 14:07:49 -04:00
Joseph Doherty 1dba46bd7b fix(focas): decode servo/spindle meters by their base/exponent envelope; MaxRpm -> MotorSpeedPct
Servo (0x0056) and spindle (0x0040) meter records are 8 bytes:
[i32 value][u16 base][u16 exponent], the same self-describing envelope as the
position blocks.

Servo: offset 4 was read as a decimal count. It is the BASE (a steady 10), so
every load was divided by 10^10 and published ~0 -- the sister ignitionoee panel
read servo 0% on every axis of a Makino cutting at 20,000 rpm. Loads are now
value / base^exponent, a direct percentage.

Spindle: the raw meter is a 1/16384 fraction of full scale. Settled on the real
Z-34184 by regressing the type-1 meter against cnc_rddynamic2 spindle speed over
596..20,000 rpm (rpm = 1.220749 x meter; 16384 x 1.220749 = 20000.75). So:
- Spindle/{name}/Load publishes % of rated load (Float64; was the raw Int32
  count -- a reading of 9155 meant 55.9%).
- Spindle/{name}/MaxRpm is RENAMED Spindle/{name}/MotorSpeedPct (Float64, % of
  maximum speed) and is polled with Load. The old node was actively wrong: the
  type-1 meter is the live motor speed, and it was read once at bootstrap and
  served forever as if it were a max-RPM constant. Client-visible: FIXED: tags
  on .../MaxRpm must be re-pointed.
- The spindle read no longer stops at the first zero after slot 1 (which dropped
  an idle second spindle and kept non-zero residue); every slot is returned.

A record whose envelope is undescribable (base not 2/10, exponent > 18 -- e.g.
residue past the configured axis/spindle count) publishes BadNoData, never a Good 0.

Ported from the sister ignitionoee FOCAS driver v0.17.2/v0.17.3 (Focas.Wire-019);
live captures live-spmeter-{load,maxrpm}-0x0040.bin added as fixtures.
2026-10-07 14:07:22 -04:00
Joseph Doherty 28bbb5e5e2 fix(abcip): browse program-scoped tags and surface symbol array dimensions
Live read-only check against production CompactLogix 5069-L320ERS2 presses:
- The controller @tags listing names each program (Program:UN01_Press, a system symbol)
  but none of its tags; those are listed only by Program:<name>.@tags. The enumerator read
  @tags alone, so every program-scoped tag was unbrowseable — including the PackML state
  (Program:UN01_Press.Out_eState) and all 51 alarm bits the Ignition project reads. The
  enumerator now reads each program's listing and decodes it with that program as scope;
  an unreadable program listing is skipped, not fatal.
- The Symbol Object decoder ignored the dimension bits + dim words, so every discovered
  array (DINT[32], REAL[32], STRING[50], UDT[23] on the two controllers checked) browsed as
  a scalar. IsArray/ElementCount are now populated (multi-dim flattened). A 1-D single
  element entry stays scalar: ab_server reports every scalar that way, a real controller
  sets no dimension bits on scalars.

Pinned by entries captured off the controllers (CipSymbolObjectRealControllerCaptureTests,
AbCipProgramScopeEnumerationTests).
2026-10-07 14:06:48 -04:00
Joseph Doherty 83a314e734 fix(twincat): string subscriptions, Windows-1252 STRING decode, and declared-type kind checks (ignitionoee 0.19.2-0.19.4)
Port of the ignitionoee TwinCAT string + type-reconciliation fixes onto the
Beckhoff-library client:

- STRING/WSTRING subscriptions never worked: AddDeviceNotificationExAsync was
  called with typeof(string) and no length, and the Beckhoff any-type
  marshaller throws ArgumentNullException for a string without one, so one
  string tag tore down its whole subscribe call. A string now registers the
  PLC's own byte width as raw bytes (0.19.2: STRING(n) of any n).
- Strings are read as raw bytes and decoded by TwinCATStringCodec. The
  Beckhoff marshaller already cut a read at the first NUL (0.19.3 / TwinCAT-007
  were not defects on the read path); the codec keeps that rule for both STRING
  and WSTRING and extends it to the new notification path. A STRING now decodes
  as Windows-1252 (TwinCAT-010) - or UTF-8 when the target reports UTF-8
  strings - instead of the host culture's ANSI code page the Beckhoff
  marshaller falls back to (1250 on a Polish host, 1251 Cyrillic, ...).
- TwinCATTypeGuard (TwinCAT-002/-008): a read refuses a numeric tag over a PLC
  string (and vice versa / STRING vs WSTRING / string over a container) with
  BadTypeMismatch instead of handing back a string object at Good; a
  notification - raw bytes decoded as the DECLARED type - additionally refuses
  width and float/integer mismatches (DINT over REAL reinterpreted the bits).
- A refused notification is isolated: that tag publishes BadTypeMismatch with
  one WARN, keeps a dead intent for the probe-tick retry, and the rest of the
  subscription registers.
2026-10-07 14:05:55 -04:00
Joseph Doherty 3b48e05e9a fix(abcip): decode real @udt template buffers; browse STRINGs as String, hide BOOL hosts
Live read-only check against production CompactLogix 5069-L320ERS2 rev 34.11 presses
(Z-35162 / 10.209.70.160): every @udt/<id> template the controller returned decoded to
null, so controller-discovered UDTs never fanned out. The decoder assumed a 12-byte
header led by the member count and [info][array][offset] blocks with ';'-terminated
names; libplctag actually returns a 14-byte header (u16 id, u32 def words, u32 instance
size, u16 member count, u16 handle), [info][type][offset] blocks, and NUL-terminated
names after a 'Name;<tail>' type name. All three test builders restated the old
assumption, so the unit suite agreed with itself (the #468 trap again); they now share a
TemplateBufferBuilder pinned by real captures (CipTemplateObjectWireCaptureTests).

Discovery follow-ons that the working decoder exposed:
- STRING (and user string types, LEN DINT + DATA SINT[n]) browse as one String variable,
  top-level and nested, not as a LEN/DATA folder.
- Controller-generated members (ZZZZZZZZZZ* BOOL hosts, __* AOI backing) are not browsed.
- A UDT array is not fanned out into element-free Tag.Member paths.
2026-10-07 14:04:11 -04:00
Joseph Doherty 69e0a622f3 fix(focas): scale positions from each cnc_rddynamic2 block; delete the fabricated cnc_getfigure
Every 0x0026 position block is self-describing: [i32 raw][u16 base][u16 exponent],
value = raw / base^exponent. The live 31i-B capture (ref-dynamic2-axis1.bin)
reports base 10 / exponent 4 on every block, so axis 1 is 280.1574 mm, not
2801574. The driver ignored the envelope and instead sent 'cnc_getfigure'
(0x00D3) -- a command that does not exist in the FOCAS wire protocol, served only
by the in-tree mock; the real control refuses it with rc=1, so on hardware every
position fell back to PositionDecimalPlaces (default 0) and published raw counts.

- ParsePositionBlock decodes the envelope into FocasPosition; the driver applies
  raw / base^exponent at publish. PositionDecimalPlaces is now only the fallback
  for a scale-less (4-byte) block.
- A block describing no position (0xFFFF vacant marker, base not 2/10, exponent
  > 18 -- raw / 10^400 would read as a Good 0.0) publishes BadNoData on that node
  alone; siblings are untouched.
- ReadPositionFiguresAsync / IFocasClient.GetPositionFiguresAsync and the
  per-axis figure cache are deleted.

Ported from the sister ignitionoee FOCAS driver v0.17.0 (+ Focas.Wire-014);
live axis-scoped captures live-dynamic2-axis{1,2}-0x0026.bin (Z-34184 X 0.0374,
Y 370.177) added as fixtures.
2026-10-07 14:03:08 -04:00