I-1: Wrap the OnValueChangedAsync AppendAsync in try/catch so a durable-boundary
failure (e.g. a PerEntry fsync hitting disk-full/I-O error) can no longer propagate
out of the handler and trip Akka supervision into a restart loop. A canceled append
during shutdown returns quietly; any other exception increments a new
_outboxAppendFailures counter, logs a Warning (exception type name only), and drops
the value without recording it or nudging the drain. The counter is surfaced on
RecorderStatus (new OutboxAppendFailures field).
I-2: Strengthen Writer_failure_keeps_entry_for_retry to prove the drain actually ran
— assert the writer was invoked (the fake records even on Succeed=false) AND the
outbox stayed at 1 (RemoveAsync not called), via AwaitAssertAsync.
M-3: Capture Sender before the await in the GetStatus handler, then Tell the reply.
M-4: Add Retry_after_writer_failure_eventually_acks proving the retry -> success ->
ack path; FakeValueWriter gains a FailFirstN option + CallCount (Succeed behaviour
unchanged). Short minBackoff keeps it fast and deterministic (AwaitAssert, no sleep).
M-5: Deregister mux interest on PostStop via DependencyMuxActor.UnregisterInterest,
mirroring VirtualTagActor.PostStop, closing the dead-letter window before Terminated.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
Continuous-historization engine for non-Galaxy driver tags. Registers
interest with the per-node DependencyMuxActor for the historized refs and
taps the VirtualTagActor.DependencyValueChanged values the mux fans:
coerce to numeric -> append to the durable IHistorizationOutbox (crash
boundary) -> off-thread drain writes batches through IHistorianValueWriter
and acks (FIFO-truncates) on success, backing off (exponential, capped) on
failure. Non-numeric values are dropped + metered (SQL analog path is
numeric-only).
- New seam IHistorianValueWriter + HistorizationValue in Core.Abstractions
so Runtime stays free of the gRPC driver.
- GatewayHistorianValueWriter (driver) adapts IHistorianGatewayClient.
WriteLiveValues: HistorizationValue -> HistorianLiveValue proto, WriteAck
Success||Queued -> true; non-throwing (errors -> false for retry).
- Drain runs via PipeTo(Self) so the mailbox never blocks on the gateway
write; appends awaited on the actor thread to stay serialized.
Adaptation vs plan: the mux fans DependencyValueChanged (TagId/Value/
TimestampUtc, no quality), not DriverInstanceActor.AttributeValuePublished,
so values are recorded Good-quality (192) by the same convention the
scripted-alarm host uses.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
Addresses Task 9 review: add the enabled+nonpositive MaxTieClusterOverfetch warning
test; update the AddServerHistorian XML doc to describe the gateway-backed data source
(the alarm-path Wonderware doc stays until T13).
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
A rename-only deploy produced an IsEmpty plan that short-circuited before MaterialiseHierarchy,
leaving the OPC UA folder DisplayName stale. AddressSpacePlanner now diffs UnsAreas/UnsLines by
stable id into a RenamedFolders set (counted in IsEmpty); the applier refreshes the folder in
place via a new UpdateFolderDisplayName on ISurgicalAddressSpaceSink (forwarded through
DeferredAddressSpaceSink so it is NOT inert on driver hosts; falls back to rebuild when the sink
is non-surgical). DeploymentArtifact byte-parity untouched (rename rides the existing Name
round-trip). No EF migration, no serialized wire/proto contract change. +13 OpcUaServer tests, Runtime rebuild test.
- OpcUaServer-002: HistoryRead-Events NumValuesPerNode==0 now maps to unbounded (int.MaxValue) instead of the backend default-cap sentinel; no Core.Abstractions contract change (+EventMaxEvents helper tests)
- OpcUaServer-004: EnsureAddressSpaceCreated guard on public mutators -> clear InvalidOperationException instead of bare NRE if called pre-start (+tests)
- OpcUaServer-003: Deferred (endUtc inclusive/exclusive needs live Wonderware boundary confirmation)
- Configuration-013: wire DraftValidator.ValidateClusterTopology into AdminOperationsActor deploy gate (read-only, no migration) (+2 tests)
Cross-module fix from the review sweep. -007 (Medium): OnTimedUnshelve built its AlarmCommand
with User=string.Empty, so Part9StateMachine.ApplyUnshelve rejected it (ArgumentException,
swallowed) and a TimedShelve never auto-expired. Pass the canonical 'system' user; the
AlarmAck-gate bypass is preserved. Repurposed the test that had encoded the bug.
Review at HEAD 7286d320. ControlPlane-001 (Medium): ConfigPublishCoordinator.HandleAck
now discards acks from nodes not in _expectedAcks (prevented premature SealDeployment) +
regression test. -002 (flipped-node log count), -003 (redundant mapper arms) tidied.
Code review at HEAD 7286d320. Security-001 (High): guard returnUrl with a local-URL
check before redirect (open-redirect/phishing vector) + regression test. Security-002:
update stale LdapOptions dev-LDAP doc reference.
Code-review follow-ups: the page-coverage test now asserts every *DriverPage
declares a _jsonOpts serializer (so a new page that serialises config a
different way fails the guard, not just converter removal); clarify that 40 ==
(int)S7CpuType.S71500 in the numeric-throws test.
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).
Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).
Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).
Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.
Found by running the never-before-run FB-9/FB-10 live verifies.
Code-review follow-ups on the FB-7 surgical shape-write commit:
- GeneralModelChangeEvent now sets SourceNode=Server + SourceName (Part 3 §8.7.4)
so clients filtering events by SourceNode match it (report still uses source:null).
- UpdateTagAttributes adds an explicit dataType null/empty guard (widened surface).
- Tighten the ArrayLengthDiffers doc comment.
- Add array→scalar transition test + null-arrayLength zero-default test (coverage
symmetry). 275/275 OpcUaServer.Tests green.
Widen the F10b surgical address-space path so a changed equipment tag whose
only differences are DataType / IsArray / ArrayLength (on top of the existing
Writable / Historizing) is applied IN PLACE on the live node instead of forcing
a full RebuildAddressSpace that drops every client's subscriptions server-wide.
ISurgicalAddressSpaceSink.UpdateTagAttributes gains (dataType, isArray,
arrayLength); the DeferredAddressSpaceSink wrapper forwards all six args (the
prod-inertness seam). OtOpcUaNodeManager swaps DataType + ValueRank +
ArrayDimensions in place, and on a real shape change (a) resets the node to
BadWaitingForInitialData so no stale wrong-typed value is exposed (closes the
prior brief-value-type-mismatch objection) and (b) raises a Part 3
GeneralModelChangeEvent (verb=DataTypeChanged) so model-aware clients re-read
the definition. A Writable/Historizing-only change leaves the shape untouched
(no reset, no model event) — original behaviour preserved byte-for-byte.
AddressSpaceApplier.TagDeltaIsSurgicalEligible adds the three shape fields to
its whitelist; FullName/Name/DriverInstanceId/alarm differences still rebuild.
Tests: new NodeManagerSurgicalShapeUpdateTests boots a real server to prove the
in-place swap + value reset + the no-reset backward-compat path + the model-event
builder; AddressSpaceApplierTests invert the two former DataType/IsArray-rebuild
cases to surgical and assert the shape args land; DeferredAddressSpaceSinkTests
assert the shape args forward. 273/273 OpcUaServer.Tests green; full solution builds.
Code-review nit: Item C asserts BuildWriteFailureAuditEvent in isolation; the
single in-lock call-site wiring is covered by inspection + the production-proven
path (bb59fd4e). Documented as a deliberate boundary with a promote-if-second-
call-site note.
Code-review nits: trim the seed name so the in-session dropdown label matches
the server-trimmed persisted name; add a null-selectedId test for
ResolveScriptLabel; and note in CreateNewScriptAsync that the ordering