96940aeb24a4f020fad734f3d19610ee3efe5251
3 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
96940aeb24 |
Modbus exception-injection profile — closes the end-to-end test gap for exception codes 0x01/0x03/0x04/0x05/0x06/0x0A/0x0B. pymodbus simulator naturally emits only 0x02 (Illegal Data Address on reads outside configured ranges) + 0x03 (Illegal Data Value on over-length); the driver's MapModbusExceptionToStatus table translates eight codes, but only 0x02 had integration-level coverage (via DL205's unmapped-register test). Unit tests lock the translation function in isolation but an integration test was missing for everything else. This PR lands wire-level coverage for the remaining seven codes without depending on device-specific quirks to naturally produce them.
New exception_injector.py — standalone pure-Python-stdlib Modbus/TCP server shipped alongside the pymodbus image. Speaks the wire protocol directly (MBAP header parse + FC 01/02/03/04/05/06/15/16 dispatch + store-backed happy-path reads/writes + spec-enforced length caps) and looks up each (fc, starting-address) against a rules list loaded from JSON; a matching rule makes the server respond [fc|0x80, exception_code] instead of the normal response. Zero runtime dependencies outside the stdlib — the Dockerfile just COPY's the script into /fixtures/ alongside the pymodbus profile JSONs, no new pip install needed. ~200 lines. New exception_injection.json profile carries rules for every exception code on FC03 (addresses 1000-1007, one per code), FC06 (2000-2001 for CPU-PROGRAM-mode and busy), and FC16 (3000 for server failure). New exception_injection compose profile binds :5020 like every other service + runs python /fixtures/exception_injector.py --config /fixtures/exception_injection.json. New ExceptionInjectionTests.cs in Modbus.IntegrationTests — 11 tests. Eight FC03-read theories exercise every exception code 0x01/0x02/0x03/0x04/0x05/0x06/0x0A/0x0B asserting the driver's expected OPC UA StatusCode mapping (BadNotSupported/BadOutOfRange/BadOutOfRange/BadDeviceFailure/BadDeviceFailure/BadDeviceFailure/BadCommunicationError/BadCommunicationError). Two FC06-write theories cover the write path for 0x04 (Server Failure, CPU in PROGRAM mode) + 0x06 (Server Busy). One sanity-check read at address 5 confirms the injector isn't globally broken + non-injected reads round-trip cleanly with Value=5/StatusCode=Good. All tests follow the MODBUS_SIM_PROFILE=exception_injection skip guard so they no-op on a fresh clone without Docker running. Docker/README.md gains an §Exception injection section explaining what pymodbus can and cannot emit, what the injector does, where the rules live, and how to append new ones. docs/drivers/Modbus-Test-Fixture.md follow-up item #2 (extend pymodbus profiles to inject exceptions) gets a shipped strikethrough with the new coverage inventory; the unit-level section adds ExceptionInjectionTests next to DL205ExceptionCodeTests so the split-of-responsibilities is explicit (DL205 test = natural out-of-range via dl205 profile, ExceptionInjectionTests = every other code via the injector). Test baselines: Modbus unit 182/182 green (unchanged); Modbus integration with exception_injection profile live 11/11 new tests green. Existing DL205/S7/Mitsubishi integration tests unaffected since they skip on MODBUS_SIM_PROFILE mismatch. Found + fixed during validation: a stale native pymodbus simulator from April 18 was still listening on port 5020 on IPv6 localhost (Windows was load-balancing between it + the Docker IPv4 forward, making injected exceptions intermittently come back as pymodbus's default 0x02). Killed the leftover. Documented the debugging path in the commit as a note for anyone who hits the same "my tests see exception 0x02 but the injector log has no request" symptom. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
0e1dcc119e |
Remove native-launcher fallbacks for the four Dockerized fixtures — Docker is the only supported path for Modbus / S7 / AB CIP / OpcUaClient integration. Native paths stay in place only where Docker isn't compatible (Galaxy: MXAccess COM + Windows-only; TwinCAT: Beckhoff runtime vs Hyper-V; FOCAS: closed-source Fanuc Fwlib32.dll; AB Legacy: PCCC has no OSS simulator). Simplifies the fixture landscape + removes the "which path do I run" ambiguity; removes two full native-launcher directories + the AB CIP native-spawn path; removes the parallel profile-as-CLI-arg-builder code from AbServerFixture.
Modbus — deletes tests/.../Modbus.IntegrationTests/Pymodbus/ (serve.ps1, standard.json, dl205.json, mitsubishi.json, s7_1500.json, README.md). Profile JSONs live only under Docker/profiles/ now. Docker/README.md loses its "Native-Python fallback" section; docs/drivers/Modbus-Test-Fixture.md "What the fixture is" bullet flipped from "primary launcher is Docker, native fallback under Pymodbus/" to "Docker is the only supported launch path". S7 — deletes tests/.../S7.IntegrationTests/PythonSnap7/ (server.py, s7_1500.json, serve.ps1, README.md). Docker/README.md loses "Native-Python fallback"; docs/drivers/S7-Test-Fixture.md updated to match. AB CIP — the biggest simplification because the native-binary spawn had the most code. AbServerFixture.cs rewrites: drops Process management (no more Process _proc + Kill/WaitForExit), drops LocateBinary() PATH lookup, drops the IAsyncLifetime initialize-spawns-server behavior. Fixture is now a thin TCP probe against localhost:44818 (or AB_SERVER_ENDPOINT override) — same shape as Snap7ServerFixture / ModbusSimulatorFixture / OpcPlcFixture. IsServerAvailable() simplifies to a single 500 ms probe. AbServerProfile.cs drops AbServerPlcArg + SeedTags + BuildCliArgs + ToCliSpec + the entire AbServerSeedTag record — the compose file is the canonical source of truth for which tags + which --plc mode each family gets; the profile record now carries just Family + ComposeProfile (matches the docker-compose service key) + Notes. KnownProfiles.ForFamily + .All stay for tests that iterate families. AbServerProfileTests.cs rewrites to match: drops BuildCliArgs_* + ToCliSpec_* + SeedTags_* tests; keeps the family-coverage contract tests + verifies the ComposeProfile strings match compose-file service names (a typo in either surfaces as a unit-test failure, not a silent "wrong family booted" at runtime). Docker/README.md loses "Native-binary fallback" section; docs/drivers/AbServer-Test-Fixture.md "What the fixture is" flipped to Docker-only with clearer skip rules. dev-environment.md §Docker fixtures — the "Native fallbacks" subsection goes away; replaced with a one-line note that Docker is the only supported path for these four fixtures + a fresh clone needs Docker Desktop and nothing else. Verified: whole-solution build 0 errors, AB CIP profile unit tests 6/6, AB CIP Docker smoke 4/4 (all family theory rows), S7 Docker smoke 3/3. Container lifecycle clean. The deleted native code surface was already redundant — every fixture the native paths served is now covered by Docker; keeping them invited drift between the two paths (the original AB CIP native profile had three undetected bugs per the #162 commit message: case-sensitive --plc, bracket tag notation, --path=1,0 requirement — noise the Docker path now avoids by never running the buggy code). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
6609141493 |
Dockerize Modbus + AB CIP + S7 test fixtures for reproducibility. Every driver integration simulator now has a pinned Docker image alongside the existing native launcher — Docker is the primary path, native fallbacks kept for contributors who prefer them. Matches the already-Dockerized OpcUaClient/opc-plc pattern from #215 so every fixture in the fleet presents the same compose-up/test/compose-down loop. Reproducibility gain: what used to require a local pip/Python install (Modbus pymodbus, S7 python-snap7) or a per-OS C build from source (AB CIP ab_server from libplctag) now collapses to a Dockerfile + docker compose up. Modbus — new tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + pymodbus[simulator]==3.13.0) + docker-compose.yml with four compose profiles (standard / dl205 / mitsubishi / s7_1500) backed by the existing profile JSONs copied under Docker/profiles/ as canonical; native fallback in Pymodbus/ retained with the same JSON set (symlink-equivalent — manual re-sync when profiles change, noted in both READMEs). Port 5020 unchanged so MODBUS_SIM_ENDPOINT + ModbusSimulatorFixture work without code change. Dropped the --no_http CLI arg the old serve.ps1 + compose draft passed — pymodbus 3.13 doesn't recognize it; the simulator's http ui just binds inside the container where nothing maps it out and costs nothing. S7 — new tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + python-snap7>=2.0) + docker-compose.yml with one s7_1500 compose profile; copies the existing server.py shim + s7_1500.json seed profile; runs python -u server.py ... --port 1102. Native fallback in PythonSnap7/ retained. Port 1102 unchanged. AB CIP — hardest because ab_server is a source-only C tool in libplctag's src/tools/ab_server/. New tests/ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests/Docker/ Dockerfile is multi-stage: build stage (debian:bookworm-slim + build-essential + cmake) clones libplctag at a pinned tag + cmake --build build --target ab_server; runtime stage (debian:bookworm-slim) copies just the binary from /src/build/bin_dist/ab_server. docker-compose.yml ships four compose profiles (controllogix / compactlogix / micro800 / guardlogix) with per-family ab_server CLI args matching AbServerProfile.cs. AbServerFixture updated: tries TCP probe on 127.0.0.1:44818 first (Docker path) + spawns the native binary only as fallback when no listener is there. AB_SERVER_ENDPOINT env var supported for pointing at a real PLC. AbServerFact/Theory attributes updated to IsServerAvailable() which accepts any of: live listener on 44818, AB_SERVER_ENDPOINT set, or binary on PATH. Required two CLI-compat fixes to ab_server's argument expectations that the existing native profile never caught because it was never actually run at CI: --plc is case-sensitive (ControlLogix not controllogix), CIP tags need [size] bracket notation (DINT[1] not bare DINT), ControlLogix also requires --path=1,0. Compose files carry the corrected flags; the existing native-path AbServerProfile.cs was never invoked in practice so we don't rewrite it here. Micro800 now uses the --plc=Micro800 mode rather than falling back to ControlLogix emulation — ab_server does have the dedicated mode, the old Notes saying otherwise were wrong. Updated docs: three fixture coverage docs (Modbus-Test-Fixture.md, S7-Test-Fixture.md, AbServer-Test-Fixture.md) flip their "What the fixture is" section from native-only to Docker-primary-with-native-fallback; dev-environment.md §Resource Inventory replaces the old ambiguous "Docker Desktop + ab_server native" mix with four per-driver rows (each listing the image, compose file, compose profiles, port, credentials) + a new Docker fixtures — quick reference subsection giving the one-line docker compose -f <…> --profile <…> up for each driver + the env-var override names + the native fallback install recipes. drivers/README.md coverage map table updated — Modbus/AB CIP/S7 entries now read "Dockerized …" consistent with OpcUaClient's line. Verified end-to-end against live containers: Modbus DL205 smoke 1/1, S7 3/3, AB CIP ControlLogix 4/4 (all family theory rows). Container lifecycle clean (up/test/down, no leaked state). Every fixture keeps its skip-when-absent probe + env-var endpoint override so dotnet test on a fresh clone without Docker running still gets a green run.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |