Addresses T15 review: treat a canceled EnsureTags task like a faulted one so the
fire-and-forget continuation never reaches t.Result (which would re-throw and leave
the discarded task unobserved).
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
Continuous-historization engine for non-Galaxy driver tags. Registers
interest with the per-node DependencyMuxActor for the historized refs and
taps the VirtualTagActor.DependencyValueChanged values the mux fans:
coerce to numeric -> append to the durable IHistorizationOutbox (crash
boundary) -> off-thread drain writes batches through IHistorianValueWriter
and acks (FIFO-truncates) on success, backing off (exponential, capped) on
failure. Non-numeric values are dropped + metered (SQL analog path is
numeric-only).
- New seam IHistorianValueWriter + HistorizationValue in Core.Abstractions
so Runtime stays free of the gRPC driver.
- GatewayHistorianValueWriter (driver) adapts IHistorianGatewayClient.
WriteLiveValues: HistorizationValue -> HistorianLiveValue proto, WriteAck
Success||Queued -> true; non-throwing (errors -> false for retry).
- Drain runs via PipeTo(Self) so the mailbox never blocks on the gateway
write; appends awaited on the actor thread to stay serialized.
Adaptation vs plan: the mux fans DependencyValueChanged (TagId/Value/
TimestampUtc, no quality), not DriverInstanceActor.AttributeValuePublished,
so values are recorded Good-quality (192) by the same convention the
scripted-alarm host uses.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
Addresses Task 9 review: add the enabled+nonpositive MaxTieClusterOverfetch warning
test; update the AddServerHistorian XML doc to describe the gateway-backed data source
(the alarm-path Wonderware doc stays until T13).
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
DriverHostActor/DriverInstanceActor and cluster events log via Akka's ILoggingAdapter, which had no Serilog bridge — under the Windows service host the default StandardOutLogger output is discarded, making the driver-role actor graph invisible (this masked the data-plane diagnosis).
- Add Akka.Logger.Serilog 1.5.60 (deps satisfied by Akka 1.5.62 / Serilog 4.3.1).
- WithOtOpcUaClusterBootstrap: ConfigureLoggers(DebugLevel; ClearLoggers(); AddLogger<SerilogLogger>()) — Akka.Hosting owns logger setup, so HOCON akka.loggers alone is not honored.
- Program.cs: set static Serilog.Log.Logger from the DI root logger after Build() (AddZbSerilog registers the MEL provider but not the static logger, which the Akka SerilogLogger and the startup banner both need).
A rename-only deploy produced an IsEmpty plan that short-circuited before MaterialiseHierarchy,
leaving the OPC UA folder DisplayName stale. AddressSpacePlanner now diffs UnsAreas/UnsLines by
stable id into a RenamedFolders set (counted in IsEmpty); the applier refreshes the folder in
place via a new UpdateFolderDisplayName on ISurgicalAddressSpaceSink (forwarded through
DeferredAddressSpaceSink so it is NOT inert on driver hosts; falls back to rebuild when the sink
is non-surgical). DeploymentArtifact byte-parity untouched (rename rides the existing Name
round-trip). No EF migration, no serialized wire/proto contract change. +13 OpcUaServer tests, Runtime rebuild test.
- OpcUaServer-002: HistoryRead-Events NumValuesPerNode==0 now maps to unbounded (int.MaxValue) instead of the backend default-cap sentinel; no Core.Abstractions contract change (+EventMaxEvents helper tests)
- OpcUaServer-004: EnsureAddressSpaceCreated guard on public mutators -> clear InvalidOperationException instead of bare NRE if called pre-start (+tests)
- OpcUaServer-003: Deferred (endUtc inclusive/exclusive needs live Wonderware boundary confirmation)
- Configuration-013: wire DraftValidator.ValidateClusterTopology into AdminOperationsActor deploy gate (read-only, no migration) (+2 tests)
Cross-module fix from the review sweep. -007 (Medium): OnTimedUnshelve built its AlarmCommand
with User=string.Empty, so Part9StateMachine.ApplyUnshelve rejected it (ArgumentException,
swallowed) and a TimedShelve never auto-expired. Pass the canonical 'system' user; the
AlarmAck-gate bypass is preserved. Repurposed the test that had encoded the bug.
Review at HEAD 7286d320. ControlPlane-001 (Medium): ConfigPublishCoordinator.HandleAck
now discards acks from nodes not in _expectedAcks (prevented premature SealDeployment) +
regression test. -002 (flipped-node log count), -003 (redundant mapper arms) tidied.
Code review at HEAD 7286d320. Host-001 (High): /metrics was auth-gated on admin
nodes (Prometheus 401) -> AllowAnonymous. Host-002: register LdapOptionsValidator
unconditionally for fail-fast startup validation on admin-only nodes. Host-004: fix
metrics XML doc. Host-003 (docs) left Open.
Code review at HEAD 7286d320. Security-001 (High): guard returnUrl with a local-URL
check before redirect (open-redirect/phishing vector) + regression test. Security-002:
update stale LdapOptions dev-LDAP doc reference.
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).
Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).
Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).
Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.
Found by running the never-before-run FB-9/FB-10 live verifies.
Live-verify finding: the surgical DataType/array path only fires for drivers whose
TagConfig carries a stable top-level FullName (Galaxy/OpcUaClient). For protocol
drivers (Modbus/S7/...), ExtractTagFullName falls back to the raw TagConfig blob, so
a shape edit also mutates FullName → safe full-rebuild fallback. Comment-only.