Commit Graph

7 Commits

Author SHA1 Message Date
Joseph Doherty 1ea1da8236 refactor(runtime): delete the dead in-place ApplyDelta seam; config change = respawn only (#665)
Since #516 a DriverConfig change is stop + respawn, so DriverSpawnPlan.ToApplyDelta
was always empty and the in-place path had no producer. #663 and #664 were both
latent bugs in it. This deletes it:
- host: ApplyChildDelta, _pendingDelta, HandleApplyResult and HandleDeltaApplied
- plan: DriverSpawnPlan.ToApplyDelta
- actor: the ApplyDelta, ApplyResult and DeltaApplied messages, the Connected
  reinit handler and the mid-connect AdoptConfigDuringInit
- tests: the actor tests that drove the seam

IDriver.ReinitializeAsync and each driver's implementation and unit tests stay.
Comments and docs that cited AdoptConfigDuringInit as the reason a driver must
release prior state at init now cite the IDriver contract and overlapping
retries, which still apply.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 11:23:16 -04:00
Joseph Doherty 55ae230fa4 ci(#606): Gitea-compatible trx upload + deterministic fixes for the CI-load test flakes
- v2-ci.yml: upload-artifact@v4 -> @v3 + continue-on-error (act_runner reports as GHES and
  v4 refuses GHES, failing every run); runner-capacity diagnostic step; AKKA_TEST_TIMEFACTOR=3
  on the test step.
- Runtime/ControlPlane harnesses: akka.test.timefactor from AKKA_TEST_TIMEFACTOR
  (TestTimeFactor), single-expect-default 15s; ControlPlane gains PresenceBudget.
- Leaked spinner threads: the infinite-loop timeout tests (Calculation, Host.IntegrationTests
  RoslynVirtualTagEvaluator, 3x Core.Scripting) pinned a core for the rest of the test process
  (abandoned, never stopped). Now a bounded 5 s wall-clock spin; outer compile-inclusive bound 30 s.
- Real test races fixed: ScriptedAlarmEngine push-during-drain (Inactive is also the start
  state + persist-before-update => wait for the Cleared save); DriverReconnectE2e (both nodes
  host the driver; Created[] is last-writer-wins and ForceReconnect is a no-op while
  Connecting); ControlPlaneStarterOrder (lost-race heal waited for a 60 s refresh tick).
- Fixed sleeps -> poll-for-condition: ReconnectSupervisor LastError, Modbus deadband steps
  (wait for observed reads), Modbus dispose hygiene precondition, FOCAS probe-loop log.
- Short presence budgets -> PresenceBudget in the Runtime/ControlPlane tests seen failing on
  Gitea; Calculation Settle 10 -> 30 s. No assertion removed, nothing skipped.
- infra/README.md §10 CI; stale TreatWarningsAsErrors comment in Directory.Build.props.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:44:31 -04:00
Joseph Doherty 409a58b624 fix(modbus): lifecycle gate + non-vacuous reprobe regression test 2026-08-16 04:07:27 -04:00
Joseph Doherty c3970a2e5d fix(modbus): dispose the previous transport and probe loops on re-initialize 2026-08-15 21:37:28 -04:00
Joseph Doherty aafb9d4929 v3(b1-modbus): RawPath identity seam — RawTagEntry-driven Modbus driver
Wave-B EXEMPLAR. Retire the pre-declared/blob-parse tag model; the driver now
builds its RawPath -> definition table from the artifact's RawTagEntry set via a
pure mapper.

- Contracts: rename ModbusEquipmentTagParser -> ModbusTagDefinitionFactory;
  TryParse(reference) -> FromTagConfig(tagConfig, rawPath) (def.Name = rawPath,
  no leading-brace heuristic); add inverse ToTagConfig(def) serializer; keep all
  strict-enum reads + guards; also read stringByteOrder/deadband/coalesceProhibited
  so a RawTagEntry round-trips the full authored def. Inspect() unchanged.
- Options: Tags(IReadOnlyList<ModbusTagDefinition>) -> RawTags(IReadOnlyList<RawTagEntry>).
- Driver: _tagsByName -> _tagsByRawPath (Ordinal); resolver byRawPath-only; build
  the table from RawTags at Initialize threading entry.WriteIdempotent onto each def;
  Discover/Teardown updated.
- Factory: remove ModbusTagDto/BuildTag/ValidateStringLength + ConfigDto.Tags; bind
  RawTags from driver-config JSON.
- CLI ModbusCommandBase.BuildOptions: serialise typed defs -> RawTagEntry via ToTagConfig.
- Tests: migrate Tags= -> RawTags via ModbusRawTags.Entries helper; parser tests ->
  FromTagConfig(rawPath); factory String-length/enum tests re-seated on the mapper seam.
- Propagated rename to ControlPlane EquipmentTagConfigInspector (outside Modbus projects).

Modbus.Tests 315/315, Addressing.Tests 161/161, Cli.Tests 72/72 green.
Docker-gated Driver.Modbus.IntegrationTests left untouched (won't compile against
the new API; expected).
2026-07-15 19:50:10 -04:00
Joseph Doherty 64e3fbe035 docs: backfill XML documentation across 756 files
v2-ci / build (push) Failing after 1m43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
2026-05-28 08:10:17 -04:00
Joseph Doherty d5322b0f9a fix(driver-modbus): resolve Low code-review findings (Driver.Modbus-003,007,008,009,010,011,012)
- Driver.Modbus-003: route every _health access through ReadHealth /
  WriteHealth helpers backed by Volatile.Read / Volatile.Write so a
  burst of concurrent ReadAsync callers always sees a complete snapshot.
- Driver.Modbus-007: promoted the Int64 / UInt64 → Int32 surfacing
  caveat to a full <remarks> block; rewrote DisableFC23's doc to flag it
  as reserved / no-op.
- Driver.Modbus-008: deleted stale duplicate doc, rewrote the
  prohibition-block summaries to credit the shipped re-probe loop, and
  removed the unused 'status' local in the ModbusException catch arm.
- Driver.Modbus-009: bind-time validation rejects StringLength < 1 for
  String tags; ModbusTcpTransport clamps keep-alive intervals to whole
  seconds (>=1).
- Driver.Modbus-010: documented WriteOnChangeOnly's cache-invalidation
  policy (reads-only) and the write-only-tag caveat.
- Driver.Modbus-011: collected the scattered instance fields into a
  single contiguous block at the top of ModbusDriver.
- Driver.Modbus-012: covered the previously-uncovered Reinitialize
  state-hygiene, malformed/truncated/empty-bitmap response, and
  DisposeAsync teardown paths.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-23 08:17:51 -04:00