- Driver.Modbus.Cli-003: ModbusCommandBase.ValidateEndpoint rejects
--port outside 1..65535, non-positive --timeout-ms, and --unit-id
outside 1..247.
- Driver.Modbus.Cli-004: wrapped SubscribeCommand's OnDataChange handler
body in a try/catch (warn-and-swallow) and serialised the console
write through a lock.
- Driver.Modbus.Cli-005: Probe / Read / Write now catch the
cancellation-during-init OperationCanceledException and print
'Cancelled.' instead of dumping a stack trace.
- Driver.Modbus.Cli-006: ProbeCommand.ComputeVerdict derives the headline
from BOTH the driver state and the probe snapshot's OPC UA quality
class so the headline can't disagree with the wire result.
- Driver.Modbus.Cli-007: docs/Driver.Modbus.Cli.md carries an explicit
'CLI scope' callout — the address-string grammar is a DriverConfig
JSON feature; the CLI takes the structured triple only.
- Driver.Modbus.Cli-008: pinned BuildOptions, ValidateEndpoint, the
region-validation guards, ComputeVerdict, and the cancellation-during-
initialize paths.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Add --bit-index, --string-length, and --string-byte-order options to
SubscribeCommand, mirroring ReadCommand, and pass them into ModbusTagDefinition
so that BitInRegister and String type subscriptions use the correct bit index and
string length rather than silently defaulting to bit-0 / zero-length.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Reviewed all 31 src/ production projects against the 10-category
checklist in REVIEW-PROCESS.md. Each module gets its own findings.md;
code-reviews/README.md is regenerated from them.
334 findings: 6 Critical, 46 High, 126 Medium, 156 Low.
Critical findings:
- Server-001: WriteNodeIdUnknown recurses unconditionally — a HistoryRead
on an unresolvable node crashes the process (remote DoS).
- Admin-001/002: app-wide auth bypass (RouteView not AuthorizeRouteView)
plus unauthenticated mutating routes.
- Core.Scripting-001: System.Environment reachable from operator scripts;
Environment.Exit() terminates the server.
- Core.AlarmHistorian-001: rowIds/events parallel-list desync on a corrupt
payload misapplies outcomes — silent alarm-event data loss.
- Driver.Galaxy-001: ReconnectSupervisor is built but never triggered, so
a transient gateway drop permanently kills the event stream.
All findings are Status=Open; resolution is tracked per REVIEW-PROCESS.md
section 4. Review only — no source code changed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>