fix(driver-modbus-cli): resolve Medium code-review finding (Driver.Modbus.Cli-001)
Add --bit-index, --string-length, and --string-byte-order options to SubscribeCommand, mirroring ReadCommand, and pass them into ModbusTagDefinition so that BitInRegister and String type subscriptions use the correct bit index and string length rather than silently defaulting to bit-0 / zero-length. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -7,7 +7,7 @@
|
||||
| Review date | 2026-05-22 |
|
||||
| Commit reviewed | `76d35d1` |
|
||||
| Status | Reviewed |
|
||||
| Open findings | 8 |
|
||||
| Open findings | 6 |
|
||||
|
||||
## Checklist coverage
|
||||
|
||||
@@ -36,7 +36,7 @@ a category produced nothing rather than leaving it blank.
|
||||
| Severity | Medium |
|
||||
| Category | Correctness & logic bugs |
|
||||
| Location | `src/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli/Commands/SubscribeCommand.cs:43-51` |
|
||||
| Status | Open |
|
||||
| Status | Resolved |
|
||||
|
||||
**Description:** `SubscribeCommand` synthesises its `ModbusTagDefinition` with only
|
||||
`Name`, `Region`, `Address`, `DataType`, `Writable`, and `ByteOrder` — it never
|
||||
@@ -54,7 +54,7 @@ options to `SubscribeCommand` (mirroring `ReadCommand`) and pass them into the
|
||||
actually supports and reject `BitInRegister` / `String` at command entry with a
|
||||
clear message.
|
||||
|
||||
**Resolution:** _(open)_
|
||||
**Resolution:** Resolved 2026-05-22 — added `--bit-index`, `--string-length`, and `--string-byte-order` options to `SubscribeCommand`, mirroring `ReadCommand`, and passed them through to `ModbusTagDefinition` so `BitInRegister` and `String` types subscribe correctly.
|
||||
|
||||
### Driver.Modbus.Cli-002
|
||||
|
||||
@@ -63,7 +63,7 @@ clear message.
|
||||
| Severity | Medium |
|
||||
| Category | Correctness & logic bugs |
|
||||
| Location | `src/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli/Commands/WriteCommand.cs:54-89` |
|
||||
| Status | Open |
|
||||
| Status | Resolved |
|
||||
|
||||
**Description:** `WriteCommand` rejects read-only regions (`DiscreteInputs` /
|
||||
`InputRegisters`) but does not validate that `--type` is meaningful for the
|
||||
@@ -78,7 +78,7 @@ region only supports `Bool`-style boolean values.
|
||||
combined with any non-boolean `--type` (anything other than `Bool`), with a
|
||||
message explaining coils carry a single bit.
|
||||
|
||||
**Resolution:** _(open)_
|
||||
**Resolution:** Resolved 2026-05-22 — added a `Region == Coils && DataType != Bool` check immediately after the read-only-region guard, throwing `CommandException` with a message explaining that coils carry a single bit and only `--type Bool` is valid.
|
||||
|
||||
### Driver.Modbus.Cli-003
|
||||
|
||||
|
||||
@@ -35,6 +35,21 @@ public sealed class SubscribeCommand : ModbusCommandBase
|
||||
"BigEndian (default) or WordSwap.")]
|
||||
public ModbusByteOrder ByteOrder { get; init; } = ModbusByteOrder.BigEndian;
|
||||
|
||||
// Driver.Modbus.Cli-001: subscribe previously lacked these three options that read and
|
||||
// write both expose. Without them, BitInRegister always watches bit 0 and String runs with
|
||||
// StringLength=0, silently producing wrong results for any subscriber using those types.
|
||||
[CommandOption("bit-index", Description =
|
||||
"For type=BitInRegister: which bit of the holding register (0-15, LSB-first).")]
|
||||
public byte BitIndex { get; init; }
|
||||
|
||||
[CommandOption("string-length", Description =
|
||||
"For type=String: character count (2 per register, rounded up).")]
|
||||
public ushort StringLength { get; init; }
|
||||
|
||||
[CommandOption("string-byte-order", Description =
|
||||
"For type=String: HighByteFirst (standard) or LowByteFirst (DirectLOGIC).")]
|
||||
public ModbusStringByteOrder StringByteOrder { get; init; } = ModbusStringByteOrder.HighByteFirst;
|
||||
|
||||
public override async ValueTask ExecuteAsync(IConsole console)
|
||||
{
|
||||
ConfigureLogging();
|
||||
@@ -47,7 +62,10 @@ public sealed class SubscribeCommand : ModbusCommandBase
|
||||
Address: Address,
|
||||
DataType: DataType,
|
||||
Writable: false,
|
||||
ByteOrder: ByteOrder);
|
||||
ByteOrder: ByteOrder,
|
||||
BitIndex: BitIndex,
|
||||
StringLength: StringLength,
|
||||
StringByteOrder: StringByteOrder);
|
||||
var options = BuildOptions([tag]);
|
||||
|
||||
await using var driver = new ModbusDriver(options, DriverInstanceId);
|
||||
|
||||