Joseph Doherty 6bb5a31337 feat(admin-ui): pause live-tail snapshots while retaining bounded updates 2026-11-13 23:40:55 -05:00
Joseph Doherty 50942b4a75 Retire pending Monaco creation before editor registration 2026-11-13 23:36:55 -05:00
Joseph Doherty c6fe9c46e0 fix(admin-ui): recover root loads and clarify loaded-tree filtering 2026-11-13 23:32:11 -05:00
Joseph Doherty 7c888d1dca Preserve Fleet and Hosts readings through refresh failures 2026-11-13 23:30:42 -05:00
Joseph Doherty b4f7672d2a Synchronize shared Monaco read-only state without replacing drafts 2026-11-13 23:29:35 -05:00
Joseph Doherty 88be7734b3 docs(admin-ui): record configuration modal fixture cleanup 2026-11-13 23:25:28 -05:00
Joseph Doherty 79acb80da9 fix(admin-ui): scope configuration modal lifecycles and validation 2026-11-13 23:24:56 -05:00
Joseph Doherty f7bc69e9c3 fix(admin-ui): distinguish deployment acceptance and application progress 2026-11-13 23:22:22 -05:00
Joseph Doherty 43a3512baf Guard shared OT browse and probe lifecycle entry points 2026-11-13 23:20:20 -05:00
Joseph Doherty c5a288b080 Adapt Raw hierarchy density and menu placement to touch layouts 2026-11-13 23:09:26 -05:00
Joseph Doherty 78bad3a6c9 Expose complete diagnostic text through native disclosures 2026-11-13 22:14:57 -05:00
Joseph Doherty 3ef919a71d docs(admin-ui): record simple modal fixture cleanup 2026-11-13 22:08:06 -05:00
Joseph Doherty c086f97757 fix(admin-ui): harden simple modal field and pending lifecycles 2026-11-13 22:07:54 -05:00
Joseph Doherty b990ebe3ea Complete common picker and tree field accessibility 2026-11-13 21:52:00 -05:00
Joseph Doherty 25e78ebe92 fix(admin-ui): gate cluster and ACL actions by destination policies 2026-11-13 21:47:16 -05:00
Joseph Doherty 1fe4dbf51c Standardize cluster anatomy and gate authoring destinations 2026-11-13 21:43:30 -05:00
Joseph Doherty 78a39a1095 Standardize administrative page and table grammar 2026-11-13 21:43:30 -05:00
Joseph Doherty 75ff38103f Standardize remaining runtime page and table grammar 2026-11-13 21:43:15 -05:00
Joseph Doherty cb3400c13c fix(admin-ui): align task orientation and navigation with page policies 2026-11-13 21:42:30 -05:00
Joseph Doherty 28add408c4 Name common identity resilience and static builder fields 2026-11-13 21:38:19 -05:00
Joseph Doherty 27bca683c1 Complete protocol field associations and verify rendered inventory 2026-11-13 21:29:03 -05:00
Joseph Doherty ee8ac73e8c Standardize first runtime page and table anatomy 2026-11-13 21:24:07 -05:00
Joseph Doherty 169149f1eb Improve admin field names and generation-safe dialog lifecycle 2026-11-13 21:15:58 -05:00
Joseph Doherty 06b1743051 Associate protocol tag fields batch 3 2026-11-13 21:05:33 -05:00
Joseph Doherty 1746b04588 Associate protocol tag fields batch 2 2026-11-13 21:05:33 -05:00
Joseph Doherty 8cc053ceb7 fix(admin-ui): pass contextual names to native Monaco editor 2026-11-13 21:04:30 -05:00
Joseph Doherty 2415db8ca4 Associate AB and Focas tag editor fields 2026-11-13 20:53:58 -05:00
Joseph Doherty 7e57074653 fix(admin-ui): associate native device endpoint fields 2026-11-13 20:49:26 -05:00
Joseph Doherty 7b7fdf0eb7 Associate S7 SQL and TwinCAT driver fields and diagnostics 2026-11-13 20:42:31 -05:00
Joseph Doherty eed546d96d Associate MQTT MTConnect and OPC fields with readable feedback 2026-11-13 20:33:37 -05:00
Joseph Doherty c70bc44cd9 Associate Galaxy Heidenhain and Modbus driver fields 2026-11-13 20:23:31 -05:00
Joseph Doherty 9be717c0d7 Associate fields in AB and Focas driver editors 2026-11-13 20:19:43 -05:00
Joseph Doherty 73132b7d78 fix(opcuaclient): #910 name the per-endpoint connect budget; widen it in the #816 host-name tests
Cause: the client-side PerEndpointConnectTimeout (3 s), not opc-plc. The
validate:null case is the first test the assembly runs, so it pays the
cold-process cost of the first Basic256Sha256 connect: loading the fresh
throwaway certificate, validating the server's, and the asymmetric handshake.
In the G2 full-solution run that local work used up the budget. The opc-plc
log at 13:13:50-53Z shows the discovery channel closing at 50.709, then nothing
from the client for 3 s, then OpenSecureChannel answered at 53.775 and the
client closing the channel 48 ms later. The SDK reports a wait cancelled by
that budget as BadRequestInterrupted. opc-plc auto-accepted the certificate
(--aa, "Trusting certificate ... command line option") with no reject and no
store round-trip.

- Driver: a per-endpoint budget expiry now surfaces as TimeoutException naming
  PerEndpointConnectTimeout instead of BadRequestInterrupted or a bare
  TaskCanceledException. There is no behaviour change. Unit test added
  against a silent TCP listener.
- Test: the ServerHostNameValidationTests secure options use a 15 s budget,
  the same as the browser integration tests' 10 s. Connect latency is not
  what these tests check.
- docs/drivers/OpcUaClient.md: documents what the budget covers.
2026-11-13 12:42:45 -05:00
Joseph Doherty e299dc090a chore(ga): retire G1 - delete the stale Phase 6 compliance scripts; v2 GA exit criteria all met/waived/retired
v2-ci / unit-tests (push) Has been cancelled
The phase-6-*.ps1 scripts checked v2 Phase 6 code that later commits deliberately
deleted (76310b88 v1 Server/Admin, #522, #524, LiteDB cache, v3 migration squash):
56/56 failures were retired files, so they could not pass. Owner retired G1; G2
plus the per-area suites cover the invariants. phase-7-compliance.ps1 is untouched.
2026-11-13 10:33:43 -05:00
Joseph Doherty f93a1179dd docs(ga): G7 PASS - FOCAS live CNC on vd03 (Makino 31i-B), axis tag added via owner-approved deploy e9fbe63e
v2-ci / unit-tests (push) Waiting to run
2026-11-13 10:32:09 -05:00
Joseph Doherty 1862fab671 docs(deploy): QA vq03/vq04 switched to OpcUa:Redundancy:Mode=Warm; #138 live gate PASS (#907, #717)
v2-ci / unit-tests (push) Failing after 14m56s
Two service-env entries per node (Mode=Warm, PeerApplicationUris__0), pair stopped and
started together. Gates: 250/90, RedundancySupport Warm, standby BadOutOfService,
LocalDb sync, canary Good on the Primary; standby Write could only show BadNotWritable
(QA tags are read-only). ScadaBridge WarmCanary moved off the Standby by ServiceLevel in
0.1 s (connect-time preference); graceful Primary stop still took the 66 s connectivity
path (ScadaBridge#141). End state: Warm, vq04 Primary.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 09:00:35 -05:00
Joseph Doherty 22de358f74 docs(ga): G2 PASS (one defect fixed in f416b883; #909/#910/#911 environmental); G1 + G7 evidence recorded pending owner decision
v2-ci / unit-tests (push) Has been cancelled
2026-11-13 08:59:07 -05:00
Joseph Doherty a157b27628 fix(install): swap waits for the host process to exit before moving the folder (#908)
v2-ci / unit-tests (push) Has been cancelled
On QA (76e73e7d deploy) Invoke-OtOpcUaInstallSwap.ps1's first Move-Item of
app\ failed "file in use" right after the service reported Stopped: SCM
reports Stopped while the host is still exiting (e.g. a log file under
InstallRoot still open).

- After the stop, wait (bounded, -ProcessExitTimeoutSeconds, default 60)
  until the service's host process (PID + start time captured before the
  stop) and every process imaged under InstallRoot have exited; otherwise
  throw naming them, with nothing moved.
- The renames use [IO.Directory]::Move instead of Move-Item. On windev,
  PowerShell 7's Move-Item falls back to an item-by-item move when the
  rename fails because a file under the folder is open, and leaves a partial
  PreviousInstall tree behind (a retry then nests into it).
- The first rename is retried for at most -MoveRetrySeconds (default 10)
  while it fails because something under InstallRoot is open (a backstop
  for a holder whose image is outside InstallRoot).
- -Verify/-Reapply/-Scope semantics unchanged.

Tests: dry-run harness gains fake-process-list tests for the wait and the
retry plus AST order checks (145 passed); the Windows harness gains three
real cases (holder past the budget, holder released 2 s into the wait,
holder outside InstallRoot) - 77/0 on pwsh 7 and Windows PowerShell 5.1 on
windev; with the wait removed the first two fail.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 08:46:27 -05:00
Joseph Doherty 16ddddb2eb docs(615): G5 signed off by the Fleet Admin; every #615 gate complete, #615 closed
v2-ci / unit-tests (push) Has been cancelled
2026-11-13 08:09:37 -05:00
Joseph Doherty 5baf05f634 docs(deploy): vd03 + QA deployed c9640f5c -> 76e73e7d (#905 #906 #900 #717, LocalDb 0.3.8)
v2-ci / unit-tests (push) Has been cancelled
Executed 2026-11-13 12:27-12:48Z; target moved from the pack's 47f0b98c to the tip 76e73e7d
(HG Client 1.1.0, behaviour unchanged; note added to the pack).

- vd03: ~14 s downtime (was ~101 s; #905 window 5.7 s), SL 250, FOCAS 21/22, Mode Unset,
  HG Probe 494 -> 536 with no write RPCs (added gate for #900).
- QA: pair outage 36.5 s (was ~91 s), 250/240, both failover legs, no failback, sync
  connected, canary Good. #906: vq04 (sync server) shutdown -> Leaving 30.0 s on c9640f5c,
  21 ms on 76e73e7d; peer at 250 in 0.47 s (leg 1: 0.36 s).
- Deviation: the first Move-Item of app\ failed "file in use" right after the stop on both
  QA nodes; a retry with the service stopped succeeded (lmxopcua#908).

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 07:51:01 -05:00
Joseph Doherty c9bc358dc9 feat(cli): print array values; docs: #615 G9 PASS with otopcua-cli, G8 waived
v2-ci / unit-tests (push) Has been cancelled
G9 ran on an isolated 2-node pair (otopcua-g9, 003c7f89, Mode unset as
deployed) with otopcua-cli as the owner-approved client: A1-A3, A5, A7, A8
(graceful, ~11 s gap), B2 (docker kill, failover <1 s, ~2 s gap, 0 Bad,
survivor 250 at +44 s) and B3 (no failback) pass; A4/A5b unmet under Unset,
met under Warm (#717). G8 (CTT) waived by the owner for GA; G5 is the only
open exit criterion.

The run found the CLI printing every array as System.String[] (ServerArray
unreadable); ValueFormatter now renders [a, b] / hex for read, subscribe and
historyread, with tests. Runbook A4/A5b text updated for the #717 modes.
Evidence: docs/plans/evidence/2026-11-13-615-g9/RESULTS.md.
2026-11-13 07:46:56 -05:00
Joseph Doherty a59dbd4f07 docs(heidenhain): driver accepted, #829/#853 closed
The ignitionoee CR capture (6d2aec40: 7 h read-only sample of 34 production
controls on the Java LSV2 driver) and the 2026-11-11 iTNC 530 run did not
change the driver's code: ProgramState 0 = cutting (11,865 of 11,869 motion
pairs), 7 = idle; TNC 426/430 BadNotSupported; overrides BadUserAccessDenied
under INSPECT; capabilities Unknown until first poll; alarm classes 1/7/8 seen,
class 5 not. Owner accepted the driver on that basis; remaining limits stay
documented in Heidenhain.md §Hardware-gated.
2026-11-13 07:46:56 -05:00
Joseph Doherty 76e73e7dbf chore(historian): HistorianGateway Client/Contracts 1.1.0, typed error reason (#900)
v2-ci / unit-tests (push) Has been cancelled
Bump ZB.MOM.WW.HistorianGateway.Client + Contracts 1.0.0 -> 1.1.0 (historiangw#135,
release 6365f34). GatewayErrorReasons now reads Client 1.1.0's typed
HistorianGatewayException.StatusCode / ErrorReason / ErrorDomain (constants from
HistorianGatewayErrorReasons) instead of parsing grpc-status-details-bin itself; the
direct Grpc.StatusProto pin and reference are dropped (the client brings it). The
published client maps every RpcException to a HistorianGatewayException, so the
trailer fallback is not needed. Behaviour unchanged: FailedPrecondition +
AGGREGATE_NOT_SUPPORTED_FOR_TAG (domain historian_gateway.v1) ->
BadAggregateNotSupported, everything else keeps its handling.

Adds GatewayErrorReasonsTests (typed-property-only exceptions, so they fail against
the old trailer implementation); wire tests and docs/Historian.md updated.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 07:17:10 -05:00
Joseph Doherty 97d513f7dc docs(deploy): next vd03 + QA deploy pack c9640f5c -> 47f0b98c (#905 #906 #717 LocalDb 0.3.8), read-only preflight
v2-ci / unit-tests (push) Has been cancelled
Range, settings (no migration; OpcUa:Redundancy:Mode unset everywhere), read-only
ConfigDb/SMB/OPC UA preflight on both tiers, #905 scoped swap with -NoStart on both
tiers, #906 failover timing gate (stop the sync-server node as Primary), Unset
metadata gate, rollback with the vd03 #903 drift note. Not executed.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 07:02:20 -05:00
Joseph Doherty 003c7f8954 docs(deploy): #780 QA scripted-alarm drill passed (kill x2, quarantine, siblings Good, 250/240); config back to rev 82dd0598
v2-ci / unit-tests (push) Has been cancelled
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 06:54:09 -05:00
Joseph Doherty 36eb6d558d docs(717): Mode=Unset re-check after c569f806 (no change); a leaving node reports 0
v2-ci / unit-tests (push) Has been cancelled
T13b: the isolated otopcua-t13b pair with OpcUa:Redundancy:Mode absent, on origin/master f826af8e
(it contains c569f806) and A/B on c569f806^ (687256d6). Every check passes on both builds:
- levels 250/240;
- Good data on both nodes;
- writes, Acknowledge, AddComment and alarm delivery on the Secondary;
- graceful stop: the survivor reaches 250 259 ms after Leaving (pre-fix 270 ms);
- crash: 250 at +43.6 s (pre-fix +42.8 s), with no demotion at auto-down;
- rejoin at 240 with no failback.
The role-decision changes are gated on IsWarm and do not run under Unset.

Plan L5, the design's section 4.3 and the Warm table in Redundancy.md now say a Leaving/Exiting node
reports ServiceLevel 0, not 90 (ComputeWarm returns 0 for any member that is not Up/Joining; T13 note A).

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 06:44:46 -05:00
Joseph Doherty f826af8e8a docs(717): T13 live gate evidence on an isolated Warm pair
v2-ci / unit-tests (push) Waiting to run
Every applicable T13 leg passes on 0c19f26c + c569f806. The leg list covers:
- metadata and ServiceLevel bands;
- standby projection;
- alarm suppression with Standby ConditionRefresh and the promotion refresh;
- the three D4 demotion timings, run live;
- standby write and Part 9 refusal (BadInvalidState);
- graceful and crash failover, with no failback;
- subscription transfer;
- the Mode=Unset regression.

The two crash-path defects the gate found are fixed in c569f806. Evidence, rig files and the
raw-client harness are in docs/plans/evidence/2026-11-13-717-t13/.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 04:39:17 -05:00
Joseph Doherty 687256d68e test(717): deferred Warm coverage - 2-node handover, DataEncoding, deleted/reused items, clone matrix, ACL stand-down, per-counter metrics
v2-ci / unit-tests (push) Has been cancelled
- T3 WarmSingletonHandoverTests: real 2-node cluster, singleton under ClusterSingletonManager on both nodes; the old
  incarnation's held-back publish (older revision, higher sequence) reaches a real Warm OpcUaPublishActor after the
  handover and never demotes the new Primary. Pin: a removed node cannot rejoin from its old ActorSystem; a new one
  rejoins younger (higher up-number).
- T6 DataEncoding: Binary/XML encoded reads of a structured tag projected on the Standby; scalar encoding error kept;
  a DefaultXml item is projected, then promoted through its own encoding (TypeId i=888).
- T7 item deleted between queue and publish; ClientHandle reused by i=2267 on a payload recycled through the SDK 2.0.1
  pool (precondition asserted); WarmStandbyCloneMatrixTests over DataChange+DiagnosticInfos/EventNotificationList/
  StatusChange, clone/cached immutability, encode round-trip, real-pool stale marker.
- T8 ACL-stood-down item receives nothing from demotion or promotion; restored grant reaches it again.
- T10 per-counter MeterListener tests (by instrument instance): warm_transition, warm_role gauge, snapshot_rejected
  (publish actor both reasons + DriverHostActor's ordering gate, first actor test of it), projected_notifications,
  suppressed_alarm_events. Process-wide state tests run in non-parallel collections.
- Every test mutation-checked (26 mutations killed); no product bug found. Plan status updated.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 04:31:11 -05:00
Joseph Doherty 0c19f26c81 fix(install): cut the swap's stopped window to the swapped-in folder (#905)
v2-ci / unit-tests (push) Has been cancelled
Root cause: the protected-DACL coverage scan, not the ACL writes. Both -Reapply and
-Verify walked every denied folder (all of E:\ApiInstall on vd03, nested roots again)
with Get-ChildItem -Recurse + Get-Acl per item + a pipeline per item for -Skip, about
3.4 ms an item on PS 5.1, all while the service was stopped. An unchanged deny is read,
not rewritten; the re-applied install-folder deny propagates over ~1,400 files in 0.5 s.

- Find-OtOpcUaDenyCoverageGap: .NET enumeration, -Skip folders pruned, DACL-only
  GetAccessControl(Access) (about 0.15 ms an item); reparse points not followed.
- Get-OtOpcUaCoverageWalkRoots: each denied folder walked once (outermost only).
- Install-ScriptWorkerIsolation.ps1 -Scope All|InstallRoot|Outside (with -Reapply,
  -Verify, -PlanOnly). InstallRoot = the folder ACEs a swap drops; Outside = the rest,
  including the firewall rule (its query costs 3-5 s; its exe path does not change).
  The two partition the plan. Prints the scan time.
- Invoke-OtOpcUaInstallSwap.ps1: -Reapply/-Verify -Scope Outside before the stop (a
  failure stops before anything moves), -Scope InstallRoot inside the window; preflight
  checks the candidate carries the worker exe; prints the stopped window and its parts.
  -NoStart, -NoCarry and the pre-#901 refusal unchanged.

windev, vd03-like tree (17,851 items): stopped window 153.1 s -> 6.0 s (PS 5.1),
101.6 s -> 6.2 s (PS 7); the Outside part takes ~23 s with the old build serving.
Dry-run harness 101 -> 123 passed; Windows test 72 passed on PS 5.1 and PS 7.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 03:51:42 -05:00
Joseph Doherty f817c77e02 test(717): deferred-event boundary, ACL-filtered promotion refresh, native-ack refusal, effective-URI XML load; docs + T13 overlay
v2-ci / unit-tests (push) Has been cancelled
- Wire: an event reported while Active but deferred (#838) is delivered after demotion; the promotion refresh
  withholds an ACL-denied condition (positive control alongside); ConditionRefresh2 and model-change events on the
  Standby; a native Acknowledge is refused and never routed; Warm validates and advertises the EFFECTIVE
  ApplicationUri from an ApplicationConfigPath XML load.
- docs/Redundancy.md: Warm section, the Unset/None i=11314 behaviour (orphan readable by NodeId under Unset,
  deleted under None), instruments; OpcUaServer.md, Configuration.md, security.md, cluster-topology rule.
- docker-dev/docker-compose.warm.yml for the T13 gate (central pair, Mode=Warm).
- Plan: implementation status and the test gaps left for T13/follow-up.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 03:39:50 -05:00