128 KiB raw chunks base64-encoded into deployment_artifacts, with a per-cluster
pointer carrying a SHA-256 over the raw bytes. Reassembly verifies chunk count
AND the SHA before returning, so a partially replicated artifact reads back as a
clean miss rather than a silently truncated address space.
Adds GetCurrentUnkeyedAsync beyond the plan's interface: at the boot-failure seam
the actor cannot know its ClusterId (it is derivable only from an artifact you
already have, or from the central DB that is unreachable). Recon D-1.
The prune's 'deployment_id <> @DeploymentId' clause makes 'the pointer's target is
always present' structural rather than a side effect of clock resolution. Three
stores inside one timestamp tick fall through to a deployment_id tiebreak, and
since real ids are GUIDs that ordering is random - the row just written could lose,
leaving the pointer naming chunks that no longer exist. Verified red without the
clause.
The Runtime.Deployment namespace shadowed the Deployment EF entity type for
every file under ZB.MOM.WW.OtOpcUa.Runtime.Tests.*: C# name lookup walks the
enclosing namespace chain and finds the namespace before a using-imported type,
so 19 pre-existing call sites failed with CS0118. Caught only by a full-solution
build - the Host and its own tests compiled fine.
Layer 3 of #477: a scripted alarm's condition Quality now reflects the WORST
quality across its input tags, mirroring the native OT semantic (#477 L2).
Plumbing (quality was silently discarded twice on the live path):
- VirtualTagActor.DependencyValueChanged gains Quality (defaulted Good); the
DependencyMuxActor forwards the published AttributeValuePublished.Quality it
already carried; ScriptedAlarmHostActor.OnDependencyChanged pushes the real
quality into the engine (was hardcoded 0u/Good).
Engine (Core.ScriptedAlarms):
- ScriptedAlarmEngine computes worst-of-input quality each eval (skipping
not-yet-published inputs, which are a readiness concern, not a quality signal)
and carries it on ScriptedAlarmEvent.WorstInputStatusCode.
- A real transition carries the current worst quality so ToSnapshot's full
snapshot doesn't clobber quality back to Good (e.g. transition while Uncertain).
- A Bad input freezes the condition (no transition), like a comms-lost native
driver; a quality-bucket change with no transition emits the new
EmissionKind.QualityChanged, routed to the existing #477-L2
AlarmQualityUpdate -> WriteAlarmQuality node path (quality only, no /alerts
row, no historian write). ScriptedAlarmSource skips QualityChanged so it never
fabricates a phantom IAlarmSource event.
Host: ToSnapshot maps WorstInputStatusCode -> OpcUaQuality; OnEngineEmission
routes QualityChanged out of band.
Tests (TDD, RED-first): engine worst-carry + Bad/restore QualityChanged +
unchanged-bucket-no-emit; source swallows QualityChanged; mux forwards quality;
host Bad-dep -> AlarmQualityUpdate(no alerts) + transition snapshot carries worst.
Docs: AlarmTracking.md Layer-3 section + design doc.
Closes#478
Part 9 ConditionType.Quality was never assigned; default(StatusCode)==Good
so every native + scripted condition reported Good unconditionally — a
comms-lost device still showed a healthy, inactive, Good condition (a
wrong-VALUE bug, distinct from the null-value #473/#475). Clients (and HMIs
bucketing on IsGood) could not tell "genuinely inactive" from "lost contact".
Layer 1 — make Quality a real, plumbed field:
- AlarmConditionSnapshot gains OpcUaQuality Quality (default Good).
- MaterialiseAlarmCondition sets it (native BadWaitingForInitialData, scripted Good).
- WriteAlarmCondition projects snapshot.Quality; the delta-gate gains a Quality
member so a quality-bucket change fires a Part 9 event.
Layer 2 — drive native quality from driver connectivity (a comms-lost driver
emits no alarm transitions, and an alarm-bearing raw tag has no value variable,
so quality can't come from either existing channel):
- DriverInstanceActor Tells parent ConnectivityChanged on Connected/Reconnecting.
- DriverHostActor fans it to every native condition the driver owns as
OpcUaPublishActor.AlarmQualityUpdate (Good on connect, Bad on disconnect).
- New dedicated IOpcUaAddressSpaceSink.WriteAlarmQuality sets ONLY Quality and
fires only on a bucket change — never touches Active/Acked/Retain (an active
alarm that loses comms stays active). Not a full-snapshot re-projection, so it
can't clobber severity/message and works for a never-fired condition.
Forwarded through DeferredAddressSpaceSink (F10b trap; auto-verified by the
reflection forwarding guard). Ungated by redundancy role; no /alerts row.
Scripted conditions stay Good; worst-of-input quality deferred to #478 (Layer 3).
Tests: node-level (materialise/project/no-clobber/unknown-node no-op),
NativeAlarmProjector, DriverInstanceActor connectivity emission, DriverHostActor
fan-out, OpcUaPublishActor routing, and the wire-level guard
(Condition_event_Quality_tracks_source_connectivity_on_the_wire) — RED-verified
against a simulated pre-fix always-Good server. Existing DriverInstanceActor
parent probes ignore the new ConnectivityChanged.
Docs: docs/AlarmTracking.md §"Condition source-data Quality (#477)";
design doc docs/plans/2026-07-17-alarm-condition-quality-477-design.md.
OtOpcUa commits no plaintext secrets — the only secret-shaped committed value is
ServerHistorian:ApiKey='' (empty, disabled by default). Because the pre-host expander
is fail-closed AND section-agnostic, hard-committing a ${secret:} token would break
every dev/CI/integration boot for zero at-rest benefit. Instead document the token
delivery convention for all five config secrets (jwt/ldap/deploy/configdb/historian)
in docs/security.md and note the token option in the ServerHistorian comments.
Mechanism proven live: unseeded token boot fails with SecretNotFoundException at
pre-host expansion; seeded token resolves and boot proceeds. Behavior-neutral
(comment + doc only).
M1 (MEDIUM): the VirtualTag re-assert re-published a stale last value with a
fresh deploy-time timestamp, and VirtualTagHostActor.OnResult recorded it to
the IHistoryWriter for Historize=true plans — every deploy would append an
artificial historian sample (BadInternalError if the last state was Bad) that
never corresponded to a real evaluation. Inert today (NullHistoryWriter) but a
data-quality bug once a VT history sink binds. Fix: EvaluationResult carries an
IsReassert flag (default false), set true in VirtualTagActor.OnReassertValue;
OnResult still PUBLISHES the AttributeValueUpdate (to repair the reset node) but
SKIPS _history.Record when IsReassert. Regression test
VirtualTagHostActorTests.Reassert_of_a_historized_vtag_publishes_but_does_not_re_record_to_the_historian
(fails before — count=2 — passes after: count stays 1).
LOW-3: corrected the ordering comments in VirtualTagActor.OnReassertValue and
VirtualTagHostActor.OnApply. ApplyVirtualTags goes to the VirtualTag HOST, not
the publish actor; the ordering holds because the re-assert reaches the publish
actor via a multi-hop chain (host -> child ReassertValue -> child -> parent
EvaluationResult -> OnResult -> publish actor) and thus lands AFTER
RebuildAddressSpace in the shared publish actor's FIFO mailbox.
M2 (CONFIRMED REAL — reported as scoped follow-up, not fixed here): the same
redeploy-reset race is latent for Part 9 scripted-alarm condition nodes. A
full-rebuild deploy clears + re-materialises them fresh
(OtOpcUaNodeManager.RebuildAddressSpace clears _alarmConditions @2160;
MaterialiseAlarmCondition recreates normal state), but the engine reload does
NOT re-emit an unchanged-active condition: ScriptedAlarmEngine.LoadAsync ->
EvaluatePredicateToStateAsync (@546-552) computes ApplyPredicate(seed, true)
where seed is the persisted state from the DB-backed EfAlarmConditionStateStore,
yielding EmissionKind.None, which ScriptedAlarmHostActor.OnEngineEmission (@292)
filters. Net: an active alarm with static dependencies under-reports until its
next real transition on a full-rebuild deploy. The fix is larger/riskier than
the VT case (touches the Core engine emission contract and must publish ONLY the
OPC UA node state, NOT the alerts topic, to avoid duplicate AVEVA history rows —
the alarm analogue of M1), so per review guidance it is deferred as a scoped
follow-up rather than forced into this commit.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Equipment VirtualTags published Bad at runtime whenever their dependency
value was static. Root cause: a deploy re-materialises each VirtualTag's
UNS node to BadWaitingForInitialData (OpcUaPublishActor.HandleRebuild), but
a surviving unchanged-plan VirtualTagActor keeps its value-dedup state, so
its unchanged recompute is suppressed (VirtualTagActor.OnDependencyChanged
value dedup) and the freshly-reset node stays Bad forever. Only masked when
the dependency value changes every poll.
Fix: VirtualTagHostActor tells each surviving (not just-spawned) child to
ReassertValue on every apply; the child re-emits its last value/quality,
bypassing dedup. Ordering is safe — DriverHostActor enqueues the
RebuildAddressSpace (materialise) to the single-threaded publish actor
before the ApplyVirtualTags that triggers the re-assert, so the re-publish
lands on the freshly-materialised node.
Regression test: VirtualTagHostActorTests
.Unchanged_redeploy_reasserts_last_value_so_a_reset_uns_node_recovers
(fails before, passes after). Live-verified on docker-dev: GateVt reads
Good via both the absolute and the {{equip}}/MainPressure script forms.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Closes the WP3/WP4 boundary seam WP4 flagged: ForwardNativeAlarm (DriverHostActor,
a WP3-owned file WP4 could not edit) built the AlarmTransitionEvent without the
referencing-equipment paths, so the /alerts equipment-list chips WP4 added never
populated in production (would fail live-gate leg 5). The RawTagPlan already carries
ReferencingEquipmentPaths (the Area/Line/Equipment UNS folder paths); this rides them
onto the per-condition alarm meta and into every transition. Coordinator-owned
1-file change (WP3 merged, no parallel agent owns this file this wave).
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
H1 (HIGH): write-routing key now (AddressSpaceRealm, bareId), not bare-only.
A raw s=<RawPath> and a UNS s=<Area/Line/Equip/Eff> can collide as bare
strings; the bare-only key let a colliding raw+UNS pair route to the WRONG
driver ref (last-writer-wins). The realm the node manager resolves (RealmOf)
is now threaded through IOpcUaNodeWriteGateway.WriteAsync -> RouteNodeWrite ->
_driverRefByNodeId keyed by (realm, bareId). New regression test:
Colliding_raw_and_uns_bare_ids_route_to_their_own_driver_by_realm.
M1 (MEDIUM): discovered-node injection made coherently DORMANT. HandleDiscoveredNodes
hard-short-circuits (single enforcement point; _discoveredByDriver never
populates so the re-inject tail is inert too), with a clear log pointing at the
/raw browse-commit flow. New pin: Discovered_nodes_are_ignored_dormant_in_v3;
the 16+2 v2 injection scenarios re-pointed to an accurate skip reason
(DiscoveryInjectionDormantV3).
M2 (MEDIUM): realm-qualified dual-node self-correction tests —
Failed_uns_write_reverts_uns_node_and_leaves_raw_node_untouched +
Raw_realm_revert_reverts_raw_node_only (the second fails if the realm is dropped).
L1: removed the = AddressSpaceRealm.Uns defaults from the consequential
node-manager mutation methods (WriteValue/WriteAlarmCondition/MaterialiseAlarmCondition/
EnsureFolder/EnsureVariable/UpdateFolderDisplayName/UpdateTagAttributes/
RaiseNodesAddedModelChange/Remove*/RevertOptimisticWriteIfNeeded) + the
AttributeValueUpdate/AlarmStateUpdate records, so the compiler forces explicit
realm; read-only accessors + internal builders retain their defaults.
L3: fixed the stale VirtualTagHostActor class comment (V3NodeIds.Uns, not the
retired EquipmentNodeIds.Variable).
Also: DeploymentArtifactRawUnsParityTests — Raw/UNS node-set byte-parity
round-trip between AddressSpaceComposer.Compose and DeploymentArtifact.ParseComposition.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Wave B of Batch 4 — the runtime binding seam for the dual namespace.
Applier (both realms, explicit realm at every sink call site):
- MaterialiseRawSubtree: Raw containers as folders + Raw tags as variables
keyed by RawPath (native-alarm tag → single Part 9 condition at the RawPath),
all in AddressSpaceRealm.Raw; historian tagname = override else RawPath.
- MaterialiseUnsReferences: each UNS reference Variable under its equipment
folder (Uns realm) + an Organizes UNS->Raw edge; inherits writable/array/
historian tagname from the backing raw tag (both NodeIds -> one tagname).
- FeedHistorizedRefs / ProvisionHistorizedTags now source RAW tags (mux ref
stays single, keyed by RawPath); ApplyPureRemove tears down raw tags + UNS
refs in place (raw-container removal falls back to rebuild).
DriverHostActor (dual-NodeId, single-source fan-out):
- _nodeIdByDriverRef value gains a realm (NodeRealmRef); rebuilt from
RawTags UNION UnsReferenceVariables so one (DriverInstanceId, RawPath) fans
to the raw NodeId AND every referencing UNS NodeId with identical
value/quality/timestamp. Write inverse map keyed by the bare id; the
ns-qualified NodeId the write hook passes is normalised (BareNodeId) so a
write to either NodeId resolves the same driver ref (-> RawPath write).
- Native raw alarm condition routing is realm-tagged (Raw); AttributeValueUpdate
+ AlarmStateUpdate carry the realm through to the sink.
Retire EquipmentNodeIds -> V3NodeIds.Uns (applier/VirtualTagHostActor) and
RawPaths.Combine (DiscoveredNodeMapper, discovered nodes are Raw now).
DeploymentArtifact.ParseComposition emits the Raw + UNS subtrees byte-parity
with the composer (reconstruct entities -> AddressSpaceComposer.Compose).
Sink surface: removed the transitional `= AddressSpaceRealm.Uns` defaults from
IOpcUaAddressSpaceSink / ISurgicalAddressSpaceSink / SdkAddressSpaceSink /
DeferredAddressSpaceSink / NullOpcUaAddressSpaceSink — every call site is now
explicit (realm reordered before the trailing optionals on EnsureVariable +
MaterialiseAlarmCondition). Node-manager convenience methods keep their
defaults (they are not the interface impl; Sdk delegates explicitly).
Tests: rewrote DriverHostActorLiveValueTests (fan-out drift, 1:N) +
DriverHostActorWriteRoutingTests (dual-NodeId raw/uns write routing) to the v3
raw+uns model; new AddressSpaceApplierRawUnsTests; migrated the EquipmentTags
provisioning/feed tests to RawTags; swept EquipmentNodeIds test callers.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
A calc-tag add/remove/edit or a script edit changes the merged DriverConfig,
which DriverSpawnPlanner routes to an in-place ApplyDelta (not a respawn), i.e.
CalculationDriver.ReinitializeAsync. The old ReinitializeAsync ignored the new
config: the tag table + dependency-ref set were built once at construction and
never rebuilt, so after a redeploy added tags never computed, removed tags kept
publishing, and edited scripts served stale results (deploy reported success).
Part 1 (HIGH): extract RebuildTagTable(config) — shared by the ctor and reinit
so they cannot drift — and have ReinitializeAsync re-bind the new config
(ParseOptions) and rebuild _tagsByRawPath/_changeDependents/_dependencyRefs/
_stateByRawPath under _lock, preserving last-known state for surviving tags,
dropping removed tags, and starting new tags fresh. _dependencyRefs now reflects
the new authored tags. Corrected the now-false ReinitializeAsync comment.
Part 2 (MEDIUM ordering hazard): the host's ReRegister was Tell-ed synchronously
alongside the ApplyDelta Tell, so the adapter re-read DependencyRefs before the
async ReinitializeAsync rebuilt them (stale set, no self-correction). Now
DriverInstanceActor sends DeltaApplied(driverInstanceId) to DriverHostActor
AFTER ReinitializeAsync completes, and HandleDeltaApplied re-registers only that
driver's adapter — sequenced after the rebuild. Removed the inline loop.
Test: added a redeploy test to CalculationDependencyFlowTests exercising the
real DependencyMuxActor + adapter + driver — a new tag reading a NEW dep flows +
computes, a removed tag stops publishing, an edited script serves the new
result, and DependencyRefs re-registers the new set. Fails on pre-fix code
(DependencyRefs stays stale ["src/a"]), passes after the fix.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Adds the Calculation pseudo-driver (tags computed by C# scripts over other tags' live
values) plus the host seam that feeds it:
- IDependencyConsumer capability interface (Core.Abstractions) + DriverTypeNames.Calculation.
- CalculationDriver : IDriver, ISubscribable, IReadable, IDependencyConsumer — change-gate +
dedupe (VirtualTagActor parity), timer-group scheduler, Bad-transition + script-log emission,
Good recovery; reuses the T0-4 CalculationEvaluator.
- DriverHostActor spawns a DependencyConsumerMuxAdapter per dependency-consuming driver,
registering its refs on the per-node DependencyMuxActor and forwarding DependencyValueChanged
→ OnDependencyValue; re-registers on every apply, torn down with the driver.
- Factory + probe registered in DriverFactoryBootstrap (keeps the T0-3 guard green); guard test
csproj references the driver so the bin-scan discovers the factory.
- DeploymentArtifact injects the resolved scriptSource (scriptId → SourceCode) into a calc tag's
delivered TagConfig so the host-blind driver can compile it.
- DraftValidator deploy gates: CalculationScriptMissing / CalculationScriptNotFound (scriptId
existence) + CalculationDependencyCycle (DependencyGraph.DetectCycles over calc→calc edges).
- Tests: driver units (dep-ref extraction, change-gate, dedupe, Bad+script-log+recovery, timer,
read), tag-config parsing, DraftValidator gates (self/2-cycle/cross-driver-terminal), and a
Runtime integration test proving values FLOW mux → adapter → driver → calc-of-calc end-to-end.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
- ConfigComposer: snapshot v3 tables (RawFolders/TagGroups/UnsTagReferences),
drop the retired Namespaces snapshot; RevisionHash follows the new blob.
- DeploymentArtifact: compute each raw tag's RawPath (RawFolder->Driver->Device->
TagGroup ancestry via shared RawPathResolver); per-driver RawTags + merged
DriverConfig+DeviceConfig config injected into DriverInstanceSpec via
DriverDeviceConfigMerger; ParseComposition emits an empty EquipmentTags set
(DARK until Batch 4); EquipmentNode driver/device hooks always null; cluster
scoping attributes equipment by UNS line only.
- AddressSpaceComposer: rewritten to the v3 shape (no Namespace/NamespaceKind,
no dropped Tag/Equipment fields); emits empty EquipmentTags (parity mirror).
- DriverHostActor: fan-out/write map tuple member FullName -> RawPath.
- Commons: new RawPathResolver (shared identity authority) + DriverDeviceConfigMerger
(single/multi-device endpoint+RawTags merge).
- DraftValidator: v3 rules — raw-name charset (RawPaths.ValidateSegment),
historized effective-tagname <=255, UNS effective-leaf uniqueness across
UnsTagReference/VirtualTag/ScriptedAlarm; DraftSnapshot(+Factory) carry the new tables.
- AdminOperationsActor: tag-config inspection resolves driver via Device (no
EquipmentId/DriverInstanceId on Tag).
- Tests: RawPathResolver/merger unit tests (Commons.Tests, green) +
DeploymentArtifact RawPath/dark test (Runtime.Tests, awaits WP6 corpus fixes).
Four continuous-historization types (IHistorizationOutbox, HistorizationOutboxEntry,
IHistorianValueWriter/HistorizationValue, HistorizationCommitMode) drifted into a
ZB.MOM.WW.OtOpcUa.Core.Abstractions.Historian sub-namespace while the other six files
in the same folder correctly use the root namespace. This violated decision #59's
flat-public-surface rule and left InterfaceIndependenceTests.AllPublicTypes_LiveInRootNamespace
red on master (pre-existing, predates round-2 remediation).
Move all four to the root namespace and drop/retarget the now-redundant
'using ...Core.Abstractions.Historian;' in the ~11 consumers. No behavioral change.
Verified: Core.Abstractions.Tests 129/129 (was 128/129), Runtime.Tests Historian+DI 72/72,
Gateway driver unit 102/102, full solution build 0 errors.
The DriverInstance.ResilienceConfig column was authored in AdminUI, persisted to the
entity, and serialized into the deployment artifact by ConfigComposer — but the runtime
read path dropped it: DriverInstanceSpec didn't carry it and the invoker factory always
passed null, so every driver got tier defaults regardless of its configured overrides
(a silent dead-config gap — #10's residual sub-finding).
Read-path plumbing (write side was already complete):
- DriverInstanceSpec gains ResilienceConfig; DeploymentArtifact.TryReadSpec reads the column.
- IDriverCapabilityInvokerFactory.Create takes resilienceConfigJson; DriverHostActor.SpawnChild
threads spec.ResilienceConfig; the concrete factory parses it (ParseOrDefaults, layering on the
tier), logs any parse diagnostic (never throws), and builds the invoker with the merged options.
- Invalidate-on-change: the pipeline cache keys on (instance, host, capability) and ignores options
on a hit, so Create() now Invalidate()s the instance's cached pipelines first (no-op on first
spawn) — a respawn with changed options rebuilds them.
- DriverSpawnPlanner treats a ResilienceConfig change as a stop+respawn (the invoker/options are
bound to the child at spawn); a pure DriverConfig change stays an in-place delta (no reconnect).
- Host DI passes a logger to the factory for the parse diagnostic.
Verification (deterministic): factory Create applies a retryCount:0 override to actual execution
(control test proves tier default retries), invalidates the instance's cache on re-create (scoped —
sibling survives), malformed config logs+falls-back; planner respawns on ResilienceConfig change
(incl null→json) and stays delta on a pure config change; artifact parse carries/omits the column.
Core.Tests 243 (+5), Runtime.Tests 363 (+5), Host builds clean.
Remediates RESILIENCE-DISPATCH-GAP (surfaced by the 07/C-1 analyzer): the Phase 6.1
CapabilityInvoker resilience pipeline (retry / breaker / bulkhead / telemetry) was
constructed only in tests — the production dispatch layer called driver-capability
methods directly, bypassing it entirely.
The filed plan (thread CapabilityInvoker directly into DriverInstanceActor) is
INFEASIBLE: Runtime is deliberately Polly-free (references Core.Abstractions, not
Core — the same boundary IDriverFactory documents). So this introduces a seam,
mirroring IDriverFactory exactly:
- Core.Abstractions: IDriverCapabilityInvoker (+ NullDriverCapabilityInvoker
pass-through) and IDriverCapabilityInvokerFactory (+ null factory).
- Core: CapabilityInvoker now implements the interface; new
DriverCapabilityInvokerFactory builds a per-instance invoker over the
process-singleton pipeline builder + status tracker + tier resolver.
- Runtime: DriverInstanceActor takes an IDriverCapabilityInvoker (default =
pass-through) and routes all 6 dispatch sites (write, alarm-ack, subscribe,
unsubscribe, alarm-subscribe, discover) through it; per-host key resolved via
IPerCallHostResolver for single-ref calls, driver-instance key for bulk calls.
DriverHostActor builds + injects the real invoker per spawned driver.
- Host: DriverFactoryBootstrap registers the tracker, pipeline builder, and
concrete factory (needs DriverFactoryRegistry.GetTier). Runtime SCE resolves the
factory from DI like IDriverFactory; pass-through on nodes without it bound.
- Analyzer: IDriverCapabilityInvoker.ExecuteAsync/ExecuteWriteAsync are now
recognized wrapper homes (interface-typed invoker calls must suppress OTOPCUA0001
too). All 6 RESILIENCE-DISPATCH-GAP pragmas removed — the analyzer (an error in
Runtime) is now the standing regression guard.
Also adds retry / breaker-open / breaker-close LOGGING to the pipeline builder —
the operator-facing observability surface (the Admin /hosts reader, Phase 6.1
Stream E.2/E.3, was never built, so the pipeline otherwise runs silently).
Scope notes:
- Tier-DEFAULT policy only: DriverInstanceSpec (the deploy artifact) does not carry
the per-instance ResilienceConfig JSON, so overrides aren't applied yet (tracked
follow-up: plumb ResilienceConfig through the composer/artifact).
- GenericDriverNodeManager's call is NOT wired: that class is test-only scaffolding
(zero production references — the Server has its own address-space path); its
pragma is re-annotated accordingly, not left as a "tracked gap".
Verification (unit + analyzer; live behavioral gate still pending — see FOLLOWUP-10):
- Negative control: unwrapping any site fails the Runtime build with OTOPCUA0001.
- New Runtime guard (recording invoker): write routes via ExecuteWriteAsync with the
IPerCallHostResolver host; subscribe via ExecuteAsync — proves runtime routing.
- New analyzer test: the interface is a valid wrapper home.
- New pipeline-builder test: retry events are logged.
- Full solution builds clean (0 errors); Runtime.Tests 357, Core.Tests 238,
Analyzers.Tests 32 all green; pass-through default keeps existing dispatch tests
byte-for-byte unchanged.
Inject the custom UnwrappedCapabilityCallAnalyzer as an OutputItemType=Analyzer
ProjectReference from Directory.Build.props (excluding the analyzer + its test
project) so OTOPCUA0001 runs on every src/ and tests/ compilation — it previously
enforced its CapabilityInvoker-wrapping rule against nothing but its own 31 unit
tests (the 'built-but-never-wired' failure mode).
Triage of the ~280 surfaced hits, three categories:
1. RESILIENCE-DISPATCH-GAP (7 sites, DriverInstanceActor x6 + GenericDriverNodeManager
x1): a REAL, previously-untracked gap the analyzer caught on first wiring — the
Phase 6.1 CapabilityInvoker resilience pipeline (retry/breaker/bulkhead/telemetry)
is constructed ONLY in tests and was never wired into the production dispatch
layer. Scoped per-site #pragma with a greppable RESILIENCE-DISPATCH-GAP marker
explicitly noting these are tracked-but-not-intentional, pending the dispatch-wiring
remediation (filed as a follow-up). Keeps the analyzer live everywhere else in
those projects so a NEW unwrapped call still fails the build.
2. Driver-INTERNAL self-calls (3 sites, AbCipAlarmProjection x2 + S7Driver x1):
a driver's own poll/ack path calling its own capability method. The invoker wraps
the driver from the dispatch layer OUTWARD; a driver re-wrapping its own internal
calls would double-wrap. Genuinely intentional — scoped #pragma with that rationale.
3. Wire-level test suites + manual-testing CLIs (12 projects): invoke drivers directly
by design — the analyzer's own documented intentional case. Project-level NoWarn
with a comment.
Verified: full solution build green, 0 OTOPCUA0001 hits; analyzer's 31 tests pass;
negative control — dropping one dispatch-gap pragma re-fires OTOPCUA0001 and fails
the Runtime build, proving the analyzer is genuinely live tree-wide, not disabled.
U2 (Critical): RoslynVirtualTagEvaluator ran scripts with a CancellationToken
that a synchronous Roslyn script can never observe, so one CPU-bound/infinite-
loop virtual-tag script hung the owning VirtualTagActor forever (no timeout, no
recovery). Route evaluation through the existing TimedScriptEvaluator (Task.Run
+ WaitAsync) so the wall-clock budget is real; a runaway script now returns Bad
within the timeout instead of wedging the actor.
U3 (High): the live path cached evaluators in a raw ConcurrentDictionary never
cleared on republish, leaking a collectible AssemblyLoadContext per edited
script forever. Swap in the purpose-built CompiledScriptCache (Lazy single-
compile, dispose-on-Clear) and add an apply-boundary clear: a new narrow
IScriptCacheOwner seam the VirtualTagHostActor calls on each ApplyVirtualTags
generation (mirrors ScriptedAlarmEngine's per-generation clear).
Tests: infinite-loop-fails-within-timeout (bounded by WaitAsync so a regression
fails instead of hanging), happy-path-after-wrapping, ClearCompiledScripts-
empties-cache, and a host-actor wiring guard asserting each apply generation
calls ClearCompiledScripts (theme #1 production-caller assertion). Host.Integration
VT suite 18/18, Runtime VT suite 12/12.
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
PR #423 shipped GatewayTagProvisioner + unit tests but never registered it in
DI nor passed it into the AddressSpaceApplier, so deploying historized tags used
the no-op NullHistorianProvisioning and never called the gateway's EnsureTags
(confirmed live on wonder-app-vd03: zero EnsureTags calls on a historized deploy).
Addresses HISTORIAN-GATEWAY-INTEGRATION-ISSUES.md.
Issue 1 (wire provisioner):
- Runtime: AddHistorianProvisioning extension (gated on ServerHistorian:Enabled,
mirrors AddServerHistorian) + NullHistorianProvisioning TryAdd default in
AddOtOpcUaRuntime; WithOtOpcUaRuntimeActors resolves IHistorianProvisioning and
passes it into the applier.
- Gateway driver: GatewayHistorian.CreateProvisioner factory (mirrors CreateDataSource).
- Host: Program.cs calls AddHistorianProvisioning after AddServerHistorian.
- Tests: AddHistorianProvisioningTests (config-gated registration + the
register->resolve->applier->EnsureTags chain).
Issue 2 (observability): AddressSpaceApplier logs the provisioning tally on every
successful dispatch (was gated behind Failed/Skipped > 0), including dispatched=N
so a dispatched=N/requested=0 line flags the dormant no-op. +2 tests.
Issue 3 (30s HistoryRead on unprovisioned tags): root coupling fixed by Issue 1;
documented the CallTimeout knob + coupling. Default left at 30s pending the
multi-data-point investigation the issue requests (lowering risks truncating
legitimate large reads).
Issue 4 (docs): docs/Historian.md gains a "Tag auto-provisioning (EnsureTags)"
section and CLAUDE.md a wiring/gating note (both stress ServerHistorian:Enabled).
Sibling scadaproj/CLAUDE.md carries no false claim -> unchanged.
Pre-existing Serilog observation: anchor CWD to AppContext.BaseDirectory before
AddZbSerilog so the relative file sink stops landing in C:\Windows\System32 under
the Windows-service CWD.
Builds 0-error; Runtime.Tests 355, OpcUaServer.Tests 329, Gateway.Tests 99 (+4
live-skipped) all green.
Code review found a residual silent-data-loss path: a single driver ref (mux
ref) can back SEVERAL historized equipment tags via aliasing (identical machines
sharing a register — DriverHostActor._nodeIdByDriverRef is a HashSet), each with
its own HistorianTagname. The muxRef->single-name map collapsed last-wins, so
under alias + divergent overrides only one historian tag got the value and the
rest were silently dropped — the exact failure class FU-3 exists to eliminate.
Model the fan as muxRef -> HashSet<historianName> and append ONE outbox entry per
name in OnValueChangedAsync (a per-name append failure drops only that name and
continues). Convergence removes/adds each (muxRef, name) pair individually from
the per-ref set, dropping the mux key only when its last name is removed — so
removing one alias leaves the shared ref fanning for the others with no mux churn.
Tests: aliased-refs-each-get-the-value (one fan → both historian names written),
removing-one-alias-keeps-the-ref-registered, and the override-rename test now
feeds a value post-rename to prove the write target actually moved to the new
name. Runtime 350/0, OpcUaServer 327/0; 0 warnings.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
The continuous-historization recorder conflated two identifiers into one string:
the dependency mux fans DependencyValueChanged keyed by the driver FullName
(the mux ref), but a value must be historized under the resolved historian name
(HistorianTagname override, else FullName). In the common no-override case the
two are equal, so it worked; with an override they diverge and the recorder
registered mux interest under a key the mux never fans — that tag's values were
never captured (and, had they been, would have been written under the mux ref).
Carry BOTH identifiers through the seam: a new HistorizedTagRef(MuxRef,
HistorianName) record on IHistorizedTagSubscriptionSink. The applier resolves
MuxRef = FullName and HistorianName = override-or-FullName. The recorder now
keeps a muxRef->historianName map: it registers/filters mux interest by MuxRef
but writes the outbox entry (and drains) under HistorianName. The convergence
handler re-registers the mux only when the registered key-set changes, so an
override-only rename (same FullName) updates the write target without mux churn.
Tests: a divergent-override recorder test (interest by mux ref, value written
under the override name, never the mux ref) + an override-rename no-churn test;
the applier feed tests now assert the full (mux ref, historian name) pairs.
Runtime 348/0, OpcUaServer 327/0; 0 warnings. Closes FU-3.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
The ContinuousHistorizationRecorder was spawned with an EMPTY historized-ref
set, so it registered interest in nothing and historized nothing. This feeds it
the currently-historized tag refs on every address-space deploy/redeploy so its
DependencyMuxActor interest converges to exactly the historized set (the same
refs the EnsureTags provisioning hook resolves: override-or-FullName).
Design — delta convergence (the plan is a pure DIFF):
- New seam IHistorizedTagSubscriptionSink (Core.Abstractions/Historian) with a
Null no-op singleton, mirroring how IHistorianProvisioning decouples the T15
hook. AddressSpaceApplier gains a DEFAULTED ctor param (Null sink) so all ~80
existing call sites + the production site compile unchanged.
- Apply() only ever sees a plan diff (an incremental/surgical apply carries a
delta, not the full set), so the applier feeds an add/remove DELTA computed
from AddedEquipmentTags / RemovedEquipmentTags / ChangedEquipmentTags. The
recorder keeps the full set and re-registers it. The feed is a single
non-blocking Tell behind the sink, wrapped in try/catch so a faulting feed
never blocks or breaks a deploy (same discipline as the provisioning hook).
- Recorder.UpdateHistorizedRefs(added, removed) converges the tracked set, then
— only when it actually changed — sends ONE RegisterInterest with the full set
(the mux's RegisterInterest is a full-REPLACE) or one UnregisterInterest when
it drains to empty (the mux has no per-ref unregister). An unchanged delta is
a no-op (no mux churn).
- DI: the recorder is now spawned BEFORE the applier so the adapter
(ActorHistorizedTagSubscriptionSink) can wrap its IActorRef; the Null sink is
used when continuous historization is off/unwired.
Tests: recorder convergence (add-from-empty, add+remove converge, idempotent,
drain-to-empty unregisters); applier feeds resolved added refs, removed+renamed
deltas, and survives a throwing sink. Build clean (0 warnings on touched
projects); Runtime/OpcUaServer/Gateway/AdminUI suites green.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
HistorianGateway is now the sole historian backend (read + alarm SendEvent +
continuous WriteLiveValues). Document the final state and retire the Wonderware
sidecar from the docs/config/labels:
- CLAUDE.md: rewrite the Historian section — ServerHistorian /
ContinuousHistorization / AlarmHistorian config keys, the IHistorianProvisioning
EnsureTags hook, the GatewayAlarmHistorianWriter SendEvent path + ReadEvents
dependency on gateway RuntimeDb:EventReadsEnabled=true, gateway-side
prerequisites (RuntimeDb flags + historian:read/write/tags:write scopes),
migration note, and two KNOWN-LIMITATION callouts (live-validation gate +
empty historized-ref-set recorder follow-on).
- appsettings.json: fix the stale ServerHistorian block (Host/Port/SharedSecret/
ServerCertThumbprint -> Endpoint/ApiKey/UseTls/AllowUntrustedServerCertificate/
CaCertificatePath/CallTimeout, keep MaxTieClusterOverfetch); add a disabled
ContinuousHistorization block; prune the orphaned Wonderware keys from
AlarmHistorian (keep the SQLite knobs). ApiKey env-supplied via
ServerHistorian__ApiKey (commented; valid strict JSON via _comment keys).
- README.md + docs (Historian.md, AlarmHistorian.md, Configuration.md,
ServiceHosting.md, DriverLifecycle.md, drivers/README.md, Uns.md, VirtualTags.md,
AlarmTracking.md, Client.UI.md, README.md, TestConnectProbes.md): retire the
Wonderware historian backend from current-backend descriptions; fix the stale
ServerHistorian/AlarmHistorian config tables (now gateway shape); convert
drivers/Historian.Wonderware.md to a retired stub pointing at the gateway.
- Source/UI labels (descriptive text only, no behavior change):
OtOpcUaServerHostedService.cs, HistoryPaging.cs, OtOpcUaSdkServer.cs,
HistorianAdapterActor.cs, VirtualTagModal.razor, ScriptedAlarmModal.razor,
AlarmsHistorian.razor now name the HistorianGateway backend.
Build clean (0 errors); AdminUI.Tests green (514 passed).
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
The HistorianGateway driver is now the sole historian read/write+alarm backend, so the
Wonderware sidecar projects are dead code. Removes the 5 Wonderware projects (driver,
.Client, .Client.Contracts, + their 2 test projects) from the solution and tree, and fully
retires the vestigial 'Historian.Wonderware' driver type (UI/probe-only; it had no driver
factory): the Host probe registration, the AdminUI driver-config surface (driver page,
tag-config editor/model/validator entry, address picker/builder, driver-type catalog +
dropdown + edit-router entries), and their tests. Prunes the now-unused Wonderware
connection fields (Host/Port/UseTls/ServerCertThumbprint/SharedSecret) from
AlarmHistorianOptions (keeping Enabled + the SQLite store-and-forward knobs) and refreshes
the stale XML docs that named Wonderware as the production backend.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
Addresses T18 review: GatewayHistorianValueWriter is a DI singleton holding a gRPC
channel — make it IAsyncDisposable so the container closes the channel gracefully at
shutdown. Tighten the blank-OutboxPath warning to state startup will fail.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii