Joseph Doherty a0b5095b3b docs(drivers): un-stale the MQTT README rows + track every known gap as an issue
v2-ci / build (push) Successful in 4m41s
v2-ci / unit-tests (push) Failing after 16m11s
The cross-driver README still described MQTT as pre-P2 — "Sparkplug B is P2
(`mode: SparkplugB` is a placeholder)" and "Sparkplug B has no fixture yet (P2)".
Both were false as of the P2 merge (c3a2b0f7): SparkplugB is a fully implemented
mode and the live suite is 15 tests (7 plain + 8 Sparkplug) against a
project-owned C# edge-node simulator. Mqtt.md and the scadaproj index were both
already correct; only this file missed the P2 sweep.

Filed the nine Known-gaps rows as tracking issues and linked them, so the table
stops being the only record of them:

  #507  IRediscoverable is inert in v3 (platform gap — also Galaxy/TwinCAT/AbCip)
  #508  write-through (IWritable) — NCMD/DCMD + plain publish
  #509  a metric name containing '/' cannot be browse-committed
  #510  _canRebirth captured at browse-open — reaped session still draws button
  #511  Sparkplug primary-host STATE publishing (ActAsPrimaryHost)
  #512  .Browser references .Driver — extract the client-options builder
  #513  editor writes a meaningless payloadFormat into a Sparkplug blob
  #514  Request-rebirth unarmable on a plant that birthed before the window
  #515  DataSet / Template / PropertySet metric support

#507 is the one worth reading: it is a v3 platform gap, not an MQTT bug —
DriverHostActor.HandleDiscoveredNodes hard-returns, so every IRediscoverable
driver fires into a void and the edge gaining a point needs a redeploy to show up.

No code change; docs + issue links only.
2026-07-27 13:52:08 -04:00
Joseph Doherty d5bd4226ee docs(mqtt): Sparkplug P2 live-verified; MQTT driver complete
Task 26 — the P2 milestone gate. Ran the live /run verification on an isolated
docker-dev rig (project otopcua-mqtt, ports 9210/4850-4851/14350, image built
from this branch) against the real Mosquitto TLS+auth broker and the C#
Sparkplug edge-node simulator on 10.100.0.35, and recorded the result.

The gate found three defects. Two are the same defect class the P1 gate found
twice — a hand-maintained AdminUI surface left behind by a driver-side feature —
and the third is a pre-existing cross-driver bug that only a Sparkplug flow
could surface.

  1. CRITICAL, FIXED — MqttDriverForm still shipped its P1 Sparkplug PLACEHOLDER.
     Switching Mode to SparkplugB rendered a "not available yet" notice and NO
     Group ID field, so with Sparkplug ingest fully shipped there was still no
     way to author a Sparkplug driver from the AdminUI at all. Sparkplug.GroupId
     is the driver's entire subscription filter (spBv1.0/{GroupId}/#): blank ⇒
     connected, Healthy, ingesting nothing. Now authors all five Sparkplug keys,
     MERGES over the existing sub-object rather than replacing it (so a key a
     newer driver adds inside it survives an older AdminUI), leaves it untouched
     in Plain mode, and validates the group id as the topic segment it is.
     Pinned by 8 MqttDriverFormModelTests cases, verified falsifiable — 8 RED
     with the fix stubbed out.

  2. PRE-EXISTING + CROSS-DRIVER, FIXED — every node label in the shared
     DriverBrowseTree was an <a href="#">. In a Blazor Web App, blazor.web.js's
     enhanced-navigation click interceptor resolves a bare "#" against
     <base href="/">, so clicking ANY browse-tree node label navigated the whole
     AdminUI to "/", tore down the circuit, and destroyed the hosting modal —
     losing the browse session AND the tag selection. @onclick:preventDefault
     does not help: it suppresses the browser's default action, not Blazor's own
     interceptor. Labels are now <button type="button">. Dates to the component's
     introduction (2026-05-28) and affects EVERY driver's picker; it surfaced
     only now because choosing a rebirth scope is the first flow that requires
     clicking a label rather than the ▶ toggle (always a button, always fine).

  3. FIXED (mitigation) — the browse tree rendered exactly once, at open, and
     never again, while OpenAsync returns as soon as the SUBSCRIBE is granted.
     On Sparkplug that means it is almost always empty forever, because births
     are never retained. Added a Refresh button that re-reads the root against
     the SAME session (nothing reconnects, nothing observed is lost, the tag
     selection is kept, only the armed rebirth scope is cleared).

Live gate result (all against the real broker + simulator, group OtOpcUaSim):

  - driver authored end-to-end through the fixed MqttDriverForm; blob is
    Mode:SparkplugB + Sparkplug.GroupId:OtOpcUaSim with enums as names
  - browse: BROWSER OPEN chip, Sparkplug-only rebirth panel, tree renders
    Group → EdgeNode → [Device] → Metric with the device folder Filler1 and
    node-level metric leaves SIDE BY SIDE, and "Node Control/Rebirth" as ONE
    leaf (the metric-name-is-not-a-topic-segment rule holding)
  - rebirth: group scope names the group + the 32-node cap, Cancel published
    NOTHING (simulator log unchanged); edge-node scope → "1 command published"
    and the simulator logged "rebirth NCMD #1 received; republishing metadata";
    group scope → "2 commands published", both edge nodes re-birthed; a device
    and a metric both resolve UP to "edge node EdgeA"; the panel does NOT render
    for a Plain MQTT device
  - browse-commit wrote bindable tuples with no topic/address key —
    {"groupId","edgeNodeId","metricName","deviceId"} for the device metric and
    deviceId ABSENT (not blank) for the node-level one, datatypes inherited from
    the birth (Int64 / Float)
  - deployed (Sealed), and both nodes served live changing values through OPC UA
    at the 2 s cadence — Good 0x00000000, no BadNodeIdUnknown
  - death→STALE: stopping the simulator drove both nodes to 0x80000000 with an
    empty value ~2 s later, and restarting it recovered them to Good on the new
    birth (FillCount back to its birth-declared 1000, then counting)
  - rediscovery fired exactly TWICE (once per authored scope: OtOpcUaSim/EdgeA
    7 metrics, OtOpcUaSim/EdgeA/Filler1 3 metrics) and was then gated across
    many subsequent births/rebirths — the anti-storm change gate working, and
    EdgeB correctly filtered out as an unauthored scope
  - tag editor: opens in SparkplugB (mode inference on reopen) with all four
    descriptor fields populated; blank group → "A Sparkplug group ID is
    required."; "Plant/1" rejected; "Node Control/Rebirth" ACCEPTED and saved
    with the slash whole; dataType override persists and its key is ABSENT again
    after selecting "(from birth certificate)"

Two things are NOT verified, and are recorded rather than claimed:

  - Rediscovery is INERT in v3 and this is a platform gap, not an MQTT one:
    nothing subscribes to IRediscoverable.OnRediscoveryNeeded and
    DriverHostActor.HandleDiscoveredNodes hard-returns. A DBIRTH introducing a
    metric does NOT change the OPC UA tree; redeploy. Verified from the driver's
    log line only, exactly as far as it can be verified.
  - A metric name containing "/" cannot be BROWSE-COMMITTED: the derived raw tag
    Name is a RawPath segment and may not contain "/", so the spec-mandatory
    "Node Control/Rebirth" is refused ("Row 3: Name must not contain '/'"). The
    refusal is loud and all-or-nothing, never a silently mis-bound tag, and
    Manual entry is the working path. Fixing it needs a name-sanitisation policy
    with a collision answer, so it was recorded rather than guessed at.

Also left open + documented: an empty browse tree cannot arm a rebirth (the
scope comes from a tree click, and the session side already accepts a bare
{group}/{edgeNode} — only a UI path is missing); _canRebirth is captured at
browse-open; the tag editor injects the Plain-only payloadFormat key into a
Sparkplug blob (cosmetic — the factory routes on the tuple).

Suites: offline 1528 passed / 0 failed (581 Driver.Mqtt + 809 AdminUI + 138
Core.Abstractions); live 15/15 against the broker + simulator.

Docs: docs/drivers/Mqtt.md brought fully up to date for P2 (Sparkplug config
sub-object, both tag shapes, the ingest state machine, rediscovery, browse +
rebirth + Refresh, a Known-gaps table); Mqtt-Test-Fixture.md gains the simulator
and drops its "Sparkplug has no fixture" claims; infra/README.md §3 gains the
simulator row; CLAUDE.md gains the simulator endpoint facts; the tracking doc
marks MQTT/Sparkplug COMPLETE. docker-dev/docker-compose.mqtt.yml is the
isolated-rig overlay the gate ran on.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-25 01:11:56 -04:00
Joseph Doherty 8d9155682d fix(mqtt): browse-commit writes a bindable address + a Request-rebirth affordance
Two gaps the Task 23/24 review found, both blocking Task 26's live gate.

Gap 1 — browse-commit produced a silently dead MQTT tag. RawBrowseCommitMapper
had no `Mqtt` case, so a committed leaf fell through to the generic
`{"address": …}` key. Neither MqttTagDefinitionFactory entry point reads
`address`: the tag deployed clean and reported BadNodeIdUnknown forever, with
no signal at commit time. Predates Task 23 (Plain was affected too), but Task 23
built the Sparkplug metric tree precisely so an operator could browse and commit
a binding.

The address is a DESCRIPTOR, not a reference string, and it cannot be recovered
from the browse node id: `{group}/{node}[/{device}]::{metric}` where a metric
name legitimately contains `/` (`Node Control/Rebirth`) — the ambiguity
MetricSeparator's remarks already name. So the session STATES it, via a new
`AttributeInfo.AddressFields` seam, and the mapper reads it. Which keys are
emitted is also how the mapper learns Plain vs Sparkplug — the driver type
reaching it is just `Mqtt`, and the mode lives on the driver config. Key names
are single-sourced in the new `MqttTagConfigKeys` (producer, mapper, factory),
with the literals pinned by a test so a symmetric rename cannot silently unbind
already-persisted blobs. A leaf with no stated address is refused at commit in
words rather than committed dead.

Gap 2 — RequestRebirthAsync had no UI. Task 23 shipped it backend-only; Task 26
step 1 assumes the button, and Task 25's runbook notes the picker tree stays
empty until a birth lands, so it is the only way to fill it on demand. Added to
the /raw browse modal: scope = the clicked tree node (device/metric resolve up to
their edge node, group fans out and is refused whole past 32), an explicit
two-click confirm naming the resolved scope and its consequence, the outcome or
the refusal shown rather than swallowed. Offered only for a Sparkplug session
(new `IRebirthCapableBrowseSession.RebirthAvailable` — one session class serves
both modes, so a type test alone would draw a button that can only throw) and
only to a DriverOperator; the server-side gate remains the boundary.

Tests: MQTT 545 → 581, AdminUI 781 → 800. The round-trip tests feed the emitted
blob to the REAL factory and were falsified by mutating the emitted key name.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 23:43:07 -04:00
Joseph Doherty 92ba120964 feat(mqtt): MqttDriverForm + MqttDeviceForm — the driver/device config forms P1 omitted
The P1 live gate had to insert MQTT driver config directly via SQL: DriverConfigModal and
DeviceModal both fell through to "No typed config form for driver type Mqtt" with no raw-JSON
fallback, so broker host/port/TLS/credentials were unauthorable from the AdminUI. Task 12 built
the *tag* editor; these are the driver + device surfaces.

MqttDriverForm authors the whole MqttDriverOptions connection surface (host/port/clientId,
TLS + CA pin, credentials, protocol version/clean-session/keep-alive, connect timeout, reconnect
backoffs, mode, maxPayloadBytes, and the Plain sub-object). The Sparkplug sub-object stays P2 —
a marked placeholder mirroring MqttTagConfigEditor's stub, with any existing sparkplug keys
preserved untouched.

The connection is authored on the DRIVER, not the device — unlike Modbus/S7/OpcUaClient and
contrary to what docs/drivers/Mqtt.md said. DriverDeviceConfigMerger merges a device's keys up
only when the driver has exactly ONE device, so a device-authored broker connection vanishes
silently the moment a second device is added. MqttDeviceForm is therefore informational (the
GalaxyDeviceForm shape) and round-trips DeviceConfig verbatim; it flags legacy connection keys
left on a device by a pre-form deployment, because those still win via merge-up.

Serialization goes through the ONE shared MqttJson.Options instance (Task 9's decision), never a
fifth per-form copy — pinned by an assertion that an ordinal-only reader CANNOT bind the emitted
blob, and by extending the fleet-wide DriverPageJsonConverterTests guard to resolve a form's
serializer from an explicit external-instance registry when it has no _jsonOpts field. Dropping
the converter from MqttJson.Options reddens 3 tests and leaves the symmetric round-trip green —
the Task 9 lesson, reproduced.

RawTags is stripped from the emitted blob (the deploy artifact owns it) and unknown top-level
keys survive a load->save. Validation mirrors the driver's own [Range] bounds inline, and
ToOptions() additionally clamps, so an ignored error still cannot persist a
connectTimeoutSeconds:0 driver-brick. A non-blank clientId raises the P1 live-gate warning
inline (fixed ids make redundant pair nodes evict each other while both report Healthy).

AdminUI 761/761 green (was 730), TWAE-clean; Driver.Mqtt 266/266 green.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 20:41:48 -04:00
Joseph Doherty 07a4a5ff5e docs(mqtt): P1 plain-MQTT milestone live-verified; endpoint recorded
Task 14 — the P1 milestone gate. Ran the live /run verification on a docker-dev
rig against the real Mosquitto TLS+auth fixture, and recorded the result.

The gate did its job: it found MQTT was unauthorable in production.

  RawDriverTypeDialog's driver-type list is a hand-maintained array that nobody
  added MQTT to, so the /raw "New driver" picker never offered it — with every
  other layer (contracts, driver, browser, factory, host registration, typed tag
  editor) complete and 266 green unit tests. Nothing tied that array to
  DriverTypeNames and AdminUI has no bUnit, so no offline test could see it.
  Fixed, plus RawDriverTypeDialogParityTests: a reflection parity guard that
  fails for ANY DriverTypeNames entry missing from the picker. Verified
  falsifiable — RED with "…cannot be authored from the /raw New-driver picker,
  so they are unreachable in production: Mqtt" before the one-line fix.

A second gap is left OPEN and documented, not fixed (no task ever covered it):
MqttDriverForm / MqttDeviceForm do not exist, and DriverConfigModal/DeviceModal
have no raw-JSON fallback — so an operator can create an MQTT driver but cannot
author its broker endpoint or credentials. P1 is not operator-complete until
those two razor forms land. The gate authored config via SQL to get past it.

Live gate result (isolated 2-node MAIN stack, image built from this branch,
fixture at 10.100.0.35:8883, AllowUntrustedServerCertificate rather than
pinning the CA into the rig):

  - typed MQTT tag editor renders and round-trips; Json shows the JSON-path
    field, Raw/Scalar hide it; wildcard topic a/+/c blocked at save; data-type
    list offers Float64 and no Double; qos/retainSeed absent on "(driver
    default)" and qos:2 written as a number; isHistorized/historianTagname
    survive a topic-only edit; SparkplugB renders the P2 placeholder and
    switching back keeps Plain values; jsonPath is guidance not a gate in all
    three shapes ($ seeded only for a brand-new blank tag, blank stays absent,
    clearing saves fine)
  - deployed, and both editor-written blobs resolved and served changing live
    values through OPC UA (22.8 / 1629, StatusCode Good) — no BadNodeIdUnknown
  - the bespoke #-observation browser drove a real broker session and rendered
    the fixture's actual topic tree (line1/{counter,state,temperature},
    noise/chatter, retained/seed); a Modbus device's picker still correctly
    reports "Browsing unavailable"

Also found live and documented (not a code change): both nodes of a redundant
pair run the driver, so a FIXED clientId makes them evict each other forever —
the broker logs "already connected, closing old connection" and both nodes
reconnect every ~2s while still reporting Healthy. Unset (the default) is
correct; confirmed 0 reconnects/60s on both nodes after removing it.

Suites: offline 1134 passed / 0 failed (266 Driver.Mqtt + 730 AdminUI incl. the
3 new guards + 138 Core.Abstractions); live 7/7 against the fixture.

Docs: new docs/drivers/Mqtt.md + Mqtt-Test-Fixture.md (the per-driver + fixture
convention every other driver follows), MQTT rows in docs/drivers/README.md,
TestConnectProbes.md, root README.md, and infra/README.md §3.

CLAUDE.md drift corrected while adding the MQTT endpoints:
  - the "every fixture carries project: lmxopcua" claim was false — only the
    MQTT fixture does; the filter returns one stack, not the fleet
  - lmxopcua-fix.ps1 is Windows-VM-only; on macOS drive the host over ssh/rsync
    (and the docker-dev rig itself runs locally under OrbStack)

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW