HistorianAdapterActor now subscribes to the redundancy-state DPS topic,
caches the local node's RedundancyRole, and SKIPS the durable-sink enqueue
when the local node is Secondary or Detached. Unknown/null role default-writes
so single-node deploys and the boot window never silently drop historization.
GetStatus stays ungated.
PREMISE: verified the actor is registered but FED BY NOTHING in production —
there is no AlarmHistorianEvent producer and nothing resolves its registry key
to Tell it. This is a FORWARD-LOOKING / DEFENSIVE guard, not a fix for a live
double-write: the moment a per-node feeder lands (engine -> historian, expected
as a per-node cluster broadcast like the alerts topic), only the Primary will
write to the durable sink (exactly-once across all alarm sources).
Mirrors the sibling A1 treatment of ScriptedAlarmHostActor (06c4155) and
OpcUaPublishActor's redundancy-state handler. localNode threaded through
HistorianAdapterActor.Props from ServiceCollectionExtensions (roleInfo.LocalNode).
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
Reshapes the placeholder buffered-counter actor into a thin fire-and-forget
bridge over the existing IAlarmHistorianSink contract. Default sink is
NullAlarmHistorianSink; production deployments override the DI binding to
SqliteStoreAndForwardSink wrapping WonderwareHistorianClient (the v1
components in src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Historian.Wonderware*
are reused verbatim — actor is just a mailbox-friendly entry point).
- HistorianAdapterActor.Props(IAlarmHistorianSink?) — null defaults to NullAlarmHistorianSink
- Receive<AlarmHistorianEvent>: fire-and-forget sink.EnqueueAsync
- Receive<GetStatus>: returns sink.GetStatus() (queue depth + drain state)
- ServiceCollectionExtensions.AddOtOpcUaRuntime registers the default sink
- WithOtOpcUaRuntimeActors spawns the actor + registers HistorianAdapterActorKey
- Program.cs calls AddOtOpcUaRuntime when hasDriver
Tests: 2 new (forward-to-sink + GetStatus). Runtime suite 17 → 18.