Two bundle-review fixes + idempotency coverage:
- CRITICAL: the planner ignored EquipmentTags, so an incremental deploy changing only
equipment tags produced an empty plan and HandleRebuild short-circuited before
materialising them. Add TagId to EquipmentTagPlan + Added/Removed/ChangedEquipmentTags
to Phase7Plan (diffed by TagId, in IsEmpty, driving Apply's needsRebuild) — mirroring
the GalaxyTags treatment.
- IMPORTANT: equipment variable NodeId was the raw driver FullName, which collides across
identical machines (e.g. two PLCs both exposing register 40001) — the second variable
was silently dropped. NodeId is now folder-scoped (parent/Name); FullName stays on
EquipmentTagPlan for the later values-routing milestone.
- Task 4: SDK-backed idempotency test (double-apply -> single variable); restart-safety
confirmed (RestoreApplied reuses the same RebuildAddressSpace -> HandleRebuild path).
- Minor: align composer equipment-tag sort with the artifact decoder (coalesce FolderPath).
Equipment folder DisplayName was the colloquial MachineCode; the live rebuild (artifact
ReadEquipmentNode) + composer now use the UNS level-5 Name segment, matching Area/Line
folders + EquipmentNodeWalker. NodeId stays the logical EquipmentId so browse-path
resolution + ACLs are unaffected.
Add EquipmentTagPlan + an init-only EquipmentTags member on Phase7CompositionResult
(mirror of GalaxyTags). Populate it compose-side (Tag.EquipmentId != null AND owning
namespace Kind == Equipment) and artifact-decode-side via BuildEquipmentTagPlans, with
FullName extracted from Tag.TagConfig. Init-only member (not a 7th positional param) so
existing convenience constructors + call sites are untouched.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
Closes the loop between F10b (SDK NodeManager) and F14 (Phase7Plan +
Phase7Applier). DriverHostActor's successful apply now triggers a
RebuildAddressSpace on the publish actor, which loads the latest
deployment artifact + walks composer → planner → applier through the
sink. The OPC UA address space tracks the deployed composition.
DeploymentArtifact:
- New ParseComposition(blob) → Phase7CompositionResult that decodes
Equipment + DriverInstance + ScriptedAlarm arrays into the
projection records Phase7Planner consumes. Pascal-case property
names mirror ConfigComposer.SnapshotAndFlattenAsync's output.
- Each entity reader is tolerant: missing-id rows are dropped,
natural-key sort matches Phase7Composer's contract.
OpcUaPublishActor:
- New Props params: dbFactory + applier. When wired, RebuildAddressSpace
does:
1. LoadLatestArtifact (most recent Sealed Deployment.ArtifactBlob)
2. ParseComposition → Phase7CompositionResult
3. Phase7Planner.Compute(lastApplied, next) → Phase7Plan
4. Empty plan ⇒ no-op (deploy of unchanged composition is benign)
5. applier.Apply(plan) drives sink.RebuildAddressSpace +
WriteAlarmState for removed nodes
6. lastApplied = next so the next rebuild diffs forward
- Without dbFactory/applier wiring, falls back to raw
sink.RebuildAddressSpace — the dev/Mac path before #108 binds prod.
DriverHostActor:
- New Props param opcUaPublishActor (IActorRef?). After successful
ApplyAndAck (status Applied, ACK sent), tells the publish actor
RebuildAddressSpace with the same correlation id so the audit trail
threads through. Null publish actor ⇒ no trigger (admin-only nodes).
Tests: Runtime 63 -> 69 (+6):
- ParseComposition reads Equipment/Driver/Alarm sorted by natural key
- ParseComposition returns empty for empty blob
- Rebuild with dbFactory + sealed deployment artifact triggers exactly
one sink.Rebuild call (Equipment topology added)
- Rebuild with no artifact is idempotent no-op
- Second rebuild with same composition is empty-plan no-op
- Rebuild without dbFactory falls back to raw sink.Rebuild (legacy path)
All 6 v2 test suites green: 173 tests passing.
Closes#109. Engine-wiring data flow is now end-to-end through:
Deploy → DriverHostActor.ApplyAndAck → driver spawn + ACK +
RebuildAddressSpace → OpcUaPublishActor → Phase7Applier → SDK
NodeManager → subscribed OPC UA clients see the change.
DriverHostActor.ApplyAndAck now reads the deployment artifact and
reconciles its set of DriverInstanceActor children — spawn the missing,
ApplyDelta to those with changed config, stop the removed/disabled.
The diff lives in pure DriverSpawnPlanner so it can be unit-tested
without an ActorSystem.
Adds IDriverFactory in Core.Abstractions (consumed by Runtime) +
DriverFactoryRegistryAdapter in Core.Hosting that wraps the existing
v1 DriverFactoryRegistry — Runtime stays decoupled from Polly/Serilog,
the Host wires the adapter once driver assemblies have registered.
ShouldStub(type, roles) is now actually called on every spawn — Galaxy
+ Wonderware-Historian boot stubbed on macOS/Linux or whenever the host
carries the dev role. Missing factory ⇒ stub fallback, never a crash.
Tests: 24 → 34 in Runtime (+10):
- DriverSpawnPlannerTests x7 (diff cases, type change ⇒ stop+respawn)
- DeploymentArtifactTests x5 (empty/malformed/missing fields tolerant)
- DriverHostActorReconcileTests x4 (spawn count, stub fallback,
ShouldStub gate, second-apply stops the removed)
All 6 v2 test suites green: 120 tests passing.
Closes F20 (ShouldStub wired). F7 marked partial — subscription
publishing + write path still stubbed in DriverInstanceActor itself.