Commit Graph

16 Commits

Author SHA1 Message Date
Joseph Doherty 397f9b783a feat(runtime): spawn+apply VirtualTagHostActor on deploy apply and restore 2026-06-07 05:41:04 -04:00
Joseph Doherty c7661d0510 feat(opcua): parse Equipment VirtualTag plans from the deployment artifact 2026-06-07 05:09:53 -04:00
Joseph Doherty 1b7f995aea feat(runtime): DriverHost spawns + subscribes only its own ClusterId's drivers 2026-06-07 03:19:22 -04:00
Joseph Doherty 4fca4e1aca feat(runtime): node-scoped ParseComposition filters address space by ClusterId 2026-06-07 03:15:46 -04:00
Joseph Doherty 7b2f64fdb8 refactor(runtime): case-insensitive ClusterId/NodeId match + suppress short-circuit + edge tests (review) 2026-06-07 03:12:09 -04:00
Joseph Doherty 24796f2c12 feat(runtime): ClusterId scope resolution + node-scoped driver-spec parse 2026-06-07 03:05:02 -04:00
Joseph Doherty aaf869145a fix(opcua): equipment-tag planner diff + folder-scoped NodeIds (review findings)
Two bundle-review fixes + idempotency coverage:
- CRITICAL: the planner ignored EquipmentTags, so an incremental deploy changing only
  equipment tags produced an empty plan and HandleRebuild short-circuited before
  materialising them. Add TagId to EquipmentTagPlan + Added/Removed/ChangedEquipmentTags
  to Phase7Plan (diffed by TagId, in IsEmpty, driving Apply's needsRebuild) — mirroring
  the GalaxyTags treatment.
- IMPORTANT: equipment variable NodeId was the raw driver FullName, which collides across
  identical machines (e.g. two PLCs both exposing register 40001) — the second variable
  was silently dropped. NodeId is now folder-scoped (parent/Name); FullName stays on
  EquipmentTagPlan for the later values-routing milestone.
- Task 4: SDK-backed idempotency test (double-apply -> single variable); restart-safety
  confirmed (RestoreApplied reuses the same RebuildAddressSpace -> HandleRebuild path).
- Minor: align composer equipment-tag sort with the artifact decoder (coalesce FolderPath).
2026-06-06 15:02:50 -04:00
Joseph Doherty 08cddfe128 fix(opcua): UNS equipment folders browse by friendly Name, NodeId stays the logical Id
Equipment folder DisplayName was the colloquial MachineCode; the live rebuild (artifact
ReadEquipmentNode) + composer now use the UNS level-5 Name segment, matching Area/Line
folders + EquipmentNodeWalker. NodeId stays the logical EquipmentId so browse-path
resolution + ACLs are unaffected.
2026-06-06 14:51:12 -04:00
Joseph Doherty febe462750 feat(opcua): carry Equipment-namespace tags through the deployment composition
Add EquipmentTagPlan + an init-only EquipmentTags member on Phase7CompositionResult
(mirror of GalaxyTags). Populate it compose-side (Tag.EquipmentId != null AND owning
namespace Kind == Equipment) and artifact-decode-side via BuildEquipmentTagPlans, with
FullName extracted from Tag.TagConfig. Init-only member (not a 7th positional param) so
existing convenience constructors + call sites are untouched.
2026-06-06 14:42:38 -04:00
Joseph Doherty c1ce5833e9 feat(runtime): wire driver SubscribeBulk pass so tag values stream
v2-ci / build (push) Failing after 51s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Materialised SystemPlatform/Galaxy variables previously stayed
BadWaitingForInitialData because nothing told the driver to subscribe
(OpcUaPublishActor TODO 'on a future SubscribeBulk pass') and published
values were only forwarded to the VirtualTag mux, never the OPC UA sink.

DriverHostActor now, after each apply, groups the deployment's galaxy tag
MXAccess refs by driver and sends DriverInstanceActor.SetDesiredSubscriptions;
the actor retains the set and (re)subscribes on every Connected entry, so
values resume after reconnects/redeploys (closes the F8b/#113 gap). Published
values are also forwarded to OpcUaPublishActor as AttributeValueUpdate
(NodeId == galaxy MxAccessRef) so the materialised variable shows live data.

Verified live in docker-dev: galaxy TestMachine_001 tags go Good with a
changing TestChangingInt. +1 unit test.
2026-06-06 12:31:55 -04:00
Joseph Doherty 64e3fbe035 docs: backfill XML documentation across 756 files
v2-ci / build (push) Failing after 1m43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
2026-05-28 08:10:17 -04:00
Joseph Doherty 7e22e2250c feat(runtime): #109 OpcUaPublishActor — load artifact, compose, plan-diff, apply
v2-ci / build (push) Failing after 45s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (push) Has been skipped
Closes the loop between F10b (SDK NodeManager) and F14 (Phase7Plan +
Phase7Applier). DriverHostActor's successful apply now triggers a
RebuildAddressSpace on the publish actor, which loads the latest
deployment artifact + walks composer → planner → applier through the
sink. The OPC UA address space tracks the deployed composition.

DeploymentArtifact:
  - New ParseComposition(blob) → Phase7CompositionResult that decodes
    Equipment + DriverInstance + ScriptedAlarm arrays into the
    projection records Phase7Planner consumes. Pascal-case property
    names mirror ConfigComposer.SnapshotAndFlattenAsync's output.
  - Each entity reader is tolerant: missing-id rows are dropped,
    natural-key sort matches Phase7Composer's contract.

OpcUaPublishActor:
  - New Props params: dbFactory + applier. When wired, RebuildAddressSpace
    does:
      1. LoadLatestArtifact (most recent Sealed Deployment.ArtifactBlob)
      2. ParseComposition → Phase7CompositionResult
      3. Phase7Planner.Compute(lastApplied, next) → Phase7Plan
      4. Empty plan ⇒ no-op (deploy of unchanged composition is benign)
      5. applier.Apply(plan) drives sink.RebuildAddressSpace +
         WriteAlarmState for removed nodes
      6. lastApplied = next so the next rebuild diffs forward
  - Without dbFactory/applier wiring, falls back to raw
    sink.RebuildAddressSpace — the dev/Mac path before #108 binds prod.

DriverHostActor:
  - New Props param opcUaPublishActor (IActorRef?). After successful
    ApplyAndAck (status Applied, ACK sent), tells the publish actor
    RebuildAddressSpace with the same correlation id so the audit trail
    threads through. Null publish actor ⇒ no trigger (admin-only nodes).

Tests: Runtime 63 -> 69 (+6):
- ParseComposition reads Equipment/Driver/Alarm sorted by natural key
- ParseComposition returns empty for empty blob
- Rebuild with dbFactory + sealed deployment artifact triggers exactly
  one sink.Rebuild call (Equipment topology added)
- Rebuild with no artifact is idempotent no-op
- Second rebuild with same composition is empty-plan no-op
- Rebuild without dbFactory falls back to raw sink.Rebuild (legacy path)

All 6 v2 test suites green: 173 tests passing.

Closes #109. Engine-wiring data flow is now end-to-end through:
  Deploy → DriverHostActor.ApplyAndAck → driver spawn + ACK +
    RebuildAddressSpace → OpcUaPublishActor → Phase7Applier → SDK
    NodeManager → subscribed OPC UA clients see the change.
2026-05-26 09:55:11 -04:00
Joseph Doherty 3e3f7588bd feat(runtime,host): close F7 — driver subscribe + write paths + Host DI
v2-ci / build (push) Failing after 42s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (push) Has been skipped
Three pieces landed in one batch, closing F7-residual + Host DI #106:

Runtime/DriverInstanceActor:
  - Subscribe / Unsubscribe message contracts; the Connected state
    handles them via IDriver.ISubscribable. On every OnDataChange
    event the actor publishes AttributeValuePublished to its parent
    (DriverHostActor → OpcUaPublishActor). OPC UA StatusCode is
    mapped to the 3-state OpcUaQuality enum via severity bits
    (00=Good, 01=Uncertain, 10/11=Bad).
  - DetachSubscription tears the handler off the driver on
    DisconnectObserved, Unsubscribe, and PostStop so a stale handler
    never pushes to a dead actor.
  - WriteAttribute now dispatches IWritable.WriteAsync (batch of one)
    with a 5s CancellationTokenSource; status-code propagated to
    WriteAttributeResult on non-Good results.

Host:
  - New ProjectReferences to Core + every cross-platform driver
    assembly (AbCip/AbLegacy/FOCAS/Galaxy/Modbus/S7/TwinCAT).
    Galaxy is net10 (gRPC client to mxaccessgw); the COM-bound net48
    Wonderware Historian driver stays out of the Host's reference
    closure — its .Client gRPC wrapper is what binds for historian
    needs.
  - New DriverFactoryBootstrap.AddOtOpcUaDriverFactories() registers
    a singleton DriverFactoryRegistry, invokes each driver's
    Register(registry, loggerFactory), and binds IDriverFactory to
    DriverFactoryRegistryAdapter. Replaces the F7 NullDriverFactory
    default so deploys actually materialise real IDriver instances
    on driver-role nodes. ShouldStub() still gates per-platform
    behaviour at spawn time.
  - Program.cs wires AddOtOpcUaDriverFactories() before AddAkka so
    the runtime extension can resolve IDriverFactory from DI.

Tests: Runtime 46 -> 52 (+6):
- Write returns success when StatusCode = Good
- Write propagates non-Good status code in failure Reason
- Subscribe forwards OnDataChange to parent as AttributeValuePublished
- Quality translation: Uncertain (0x40...) and Bad (0x80...)
- Subscribe against non-ISubscribable returns failure
- DisconnectObserved detaches handler so late events are dropped

All 6 v2 test suites green: 152 tests passing.

Closes F7. F7-residual sub-tasks #110 (subscribe) and #111 (write)
both shipped. Host DI binding #106 shipped.
2026-05-26 09:28:34 -04:00
Joseph Doherty da141497f8 feat(runtime): F7 spawn lifecycle + F20 ShouldStub gate
DriverHostActor.ApplyAndAck now reads the deployment artifact and
reconciles its set of DriverInstanceActor children — spawn the missing,
ApplyDelta to those with changed config, stop the removed/disabled.
The diff lives in pure DriverSpawnPlanner so it can be unit-tested
without an ActorSystem.

Adds IDriverFactory in Core.Abstractions (consumed by Runtime) +
DriverFactoryRegistryAdapter in Core.Hosting that wraps the existing
v1 DriverFactoryRegistry — Runtime stays decoupled from Polly/Serilog,
the Host wires the adapter once driver assemblies have registered.

ShouldStub(type, roles) is now actually called on every spawn — Galaxy
+ Wonderware-Historian boot stubbed on macOS/Linux or whenever the host
carries the dev role. Missing factory ⇒ stub fallback, never a crash.

Tests: 24 → 34 in Runtime (+10):
- DriverSpawnPlannerTests x7 (diff cases, type change ⇒ stop+respawn)
- DeploymentArtifactTests  x5 (empty/malformed/missing fields tolerant)
- DriverHostActorReconcileTests x4 (spawn count, stub fallback,
  ShouldStub gate, second-apply stops the removed)
All 6 v2 test suites green: 120 tests passing.

Closes F20 (ShouldStub wired). F7 marked partial — subscription
publishing + write path still stubbed in DriverInstanceActor itself.
2026-05-26 08:57:16 -04:00
Joseph Doherty 64c627f8d6 feat(runtime): DriverInstanceActor state machine with Connecting/Connected/Reconnecting 2026-05-26 05:05:36 -04:00
Joseph Doherty ed130135ca feat(runtime): DriverHostActor state machine with PreStart recovery + DispatchDeployment + stale fallback 2026-05-26 05:02:42 -04:00