10 Commits

Author SHA1 Message Date
Joseph Doherty 1d7a4b7a53 test: pass TestContext.Current.CancellationToken at xUnit1051 call sites (analyzer code fix, 451 sites) (lmxopcua#725)
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:19:34 -05:00
Joseph Doherty e7e84e0577 fix(mqtt): review minors - QoS 0 is not answer evidence, caller cancels stay cancels, rebirth wait cap, bound/trie pins (R06 G2 MQTT review minors 2 3 4 6 7 8)
2: only a PUBACKed (QoS >= 1) publish advances LastSuccessfulRead; a QoS 0 Sparkplug
command completing means only that the bytes left the local socket.
3: a no-verdict SUBSCRIBE caused by the caller's own cancellation now throws
OperationCanceledException (refs still Bad + pending), so the breaker no longer
counts a pipeline timeout as a failure.
4: the rebirth wait is the window capped at 15 s, below the AdminUI 20 s per-call
timeout.
6: a 10-topic test pins the 8-in-flight publish bound. 7: partial-level wildcards and
$share filters are pinned never to confirm. 8: the intended init-vs-shutdown
supersede is commented at the re-check.

Refs #744
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:39:24 -04:00
Joseph Doherty d77a538e17 test(mqtt): pass the test cancellation token to the wedged-init lifecycle test
Refs #744
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:17:09 -04:00
Joseph Doherty c529948745 perf(mqtt): publish a write batch concurrently, serialised per topic; writes feed health (R06:M-8)
WriteAsync published one awaited QoS 1 round-trip per request, so 50 writes to a
stalled broker cost 50 publish deadlines. Different topics now publish concurrently
(at most 8 in flight); same-topic writes stay in request order. A caller cancel still
fills every slot. A successful publish advances LastSuccessfulRead. MiniBroker now
frames packets properly and records/PUBACKs PUBLISHes.

Refs #744
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:42:50 -04:00
Joseph Doherty 43f45bb978 fix(mqtt): dispose an unpublished connection and stamp lifecycle generations (R06:M-3, M-10)
A refused initial connect (or a failed Sparkplug establish) now disposes the
MqttConnection it built. Every lifecycle operation takes a generation (initialize
inside the gate; shutdown/dispose before waiting for it): a wedged initialize that
completes after a timed-out ShutdownAsync's ungated teardown releases its session
instead of publishing it, and a superseded operation's health/host-state writes are
refused. TeardownAsync captures every field before disposing so an ungated teardown
never reaches into a later initialize's state.

Refs #744
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:26:55 -04:00
Joseph Doherty 01efd39177 fix(mqtt): retry failed SUBSCRIBEs via a pending set; throw on no-verdict subscribe (R06:M-1, M-11)
A failed SUBSCRIBE (refusal or no broker verdict) used to drop its topic from every
retry set while SubscribeAsync returned a live handle, leaving tags dark behind a
Healthy connection until a redeploy. Failed topics now join a pending set retried by
the next SubscribeAsync and by every reconnect (not counted toward the reconnect's
total-failure verdict, so an ACL-denied topic cannot reconnect-loop). A no-verdict
subscribe degrades its refs then throws so the actor's reconcile re-subscribes. A
subscribe with no transport attached is recorded pending, never established (M-11).
MiniBroker now answers SUBSCRIBE.

Refs #744
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:22:17 -04:00
Joseph Doherty 1ea1da8236 refactor(runtime): delete the dead in-place ApplyDelta seam; config change = respawn only (#665)
Since #516 a DriverConfig change is stop + respawn, so DriverSpawnPlan.ToApplyDelta
was always empty and the in-place path had no producer. #663 and #664 were both
latent bugs in it. This deletes it:
- host: ApplyChildDelta, _pendingDelta, HandleApplyResult and HandleDeltaApplied
- plan: DriverSpawnPlan.ToApplyDelta
- actor: the ApplyDelta, ApplyResult and DeltaApplied messages, the Connected
  reinit handler and the mid-connect AdoptConfigDuringInit
- tests: the actor tests that drove the seam

IDriver.ReinitializeAsync and each driver's implementation and unit tests stay.
Comments and docs that cited AdoptConfigDuringInit as the reason a driver must
release prior state at init now cite the IDriver contract and overlapping
retries, which still apply.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 11:23:16 -04:00
Joseph Doherty ad108f6a02 test(mqtt): tag 16 wall-clock-bound tests Category=SlowUnit; document local opt-out (#606)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:02:44 -04:00
Joseph Doherty 6874a562f3 test+docs(mqtt): end-to-end Bad-then-identical-replay recovery 2026-08-20 09:55:11 -04:00
Joseph Doherty 2b4b3fcbbf fix(mqtt): session-rebind subscriptions, re-init teardown, timeout clamp
Findings from the per-module review of Driver.Mqtt at b990adae
(code-reviews/Driver.Mqtt/findings.md records all ten; these are the fixed
ones).

Driver.Mqtt-001 (High) — MqttSubscriptionManager._subscribedTopics is a claim
about the broker session it established filters on, and AttachTo never cleared
it, but the manager OUTLIVES a session rebuild (AdoptOptions keeps it whenever
the ingest identity is unchanged). After a driver-host reconnect
(ShutdownAsync + InitializeAsync, the #527 watchdog's retry) or a
ReinitializeAsync that only changed the endpoint/credentials, the host's
re-subscribe resolved an empty pending set, sent no SUBSCRIBE at all, and left
the driver Connected/Healthy on a session carrying ZERO subscriptions — no
error, no Bad status, values frozen until the new session happened to drop.
AttachTo now forgets them, mirroring SparkplugIngestor.AttachTo's reset.

Driver.Mqtt-002 (High) — InitializeCoreAsync published _connection and
_primaryHost over whatever the driver already held, so a second initialize
stranded a connected, self-supervising broker session (plus a second Sparkplug
primary-host claim) that no later dispose could reach. Reachable without any
teardown of ours via DriverInstanceActor.AdoptConfigDuringInit. Now tears down
first, under the gate both callers already hold.

Driver.Mqtt-003 (Medium) — connectTimeoutSeconds is [Range]-annotated but
unvalidated on the runtime path; 0 makes every deadline fire immediately and a
negative value throws ArgumentOutOfRangeException out of ShutdownAsync and
DisposeAsync. Normalized once, at the seam every options instance passes.

Also: ShutdownAsync keeps the live last-message instant (-004), three usings
left behind by #512 removed (-005), stale remarks corrected (-009, -010), and
docs/drivers/Mqtt.md now distinguishes the two kinds of reconnect.

Tests 708 -> 713. All three regression tests were confirmed to fail against
the un-fixed code, with two controls that pass in either state.
2026-08-10 06:59:18 -04:00