- ALARM: selectors (HeidenhainAlarmSelector, Contracts): ALARM:*, ALARM:OTHER,
ALARM:CLASS=<r>[/GROUP=<r>][/NUMBER=<r>] (<r> = n | lo..hi; negative numbers allowed).
An ALARM: address and the cross-driver alarm object only work together — the factory
refuses either alone, so editor, save path, CSV and deploy inspector agree. Data type
fixed Boolean; never a value (ReadAsync BadNotSupported), never in a data subscription.
- HeidenhainDriver implements IAlarmSource: one condition per ALARM: tag at its RawPath,
driven by the SAME allowlisted R_RI 27/28 walk on the control's single loop, on the new
Polling.AlarmMs cadence (default 2000 ms, only for controls carrying an ALARM: tag).
FOCAS #647 transition rules (Raise / Retrigger / Clear), identity = class+group+number+text,
deterministic display order, told-record on the driver instance, recorded only while a
handler listens. A failed walk (refusal, overflow, comms loss) is quality-only, never a clear.
- Acknowledge is LOCAL-ONLY: AcknowledgeAsync is a no-op success (FOCAS/MTConnect posture);
Lsv2ReadOnlyPolicy is unchanged — no ack or write request exists.
- Opt-in per tag, no driver flag (FOCAS #647 / MTConnect #626 precedent); Alarms/* arrays unchanged.
- IRediscoverable: a reconnect whose R_VR identity (model / NC / PLC / options) differs from
the previous session raises OnRediscoveryNeeded once (advisory re-browse chip). No extra traffic.
- AdminUI: Heidenhain joins NativeAlarmModel's alarm drivers; the typed editor fixes ALARM:
tags at Boolean and seeds/drops the alarm object with the selector; driver form gains
"Alarm conditions (ms)". (HeidenhainDriverFormModel also carries the #830 credential-notice change.)
Tests: HeidenhainAlarmTests (grammar, pairing, rules, simulator e2e with the captured iTNC 530
alarm record, local-only ack = zero bytes sent, quality-only outage/refusal, rediscovery),
Runtime.Tests HeidenhainNativeAlarmEndToEndTests (real DriverHostActor condition), a
DraftValidator case, and the NativeAlarmDriverSetGuard now scans the Heidenhain driver.
The Test-Connect probe set is resolved inside the AdminOperations Akka starter; resolving
ISecretResolver there walks AddZbSecrets -> IAuditWriter -> ActorAuditWriter, whose ctor needs
AuditWriterActorKey (registered later in the same builder). Found by the docker-dev live gate.
Regression test: resolving the probe set never resolves ISecretResolver (fails before the fix).
Also: TagRowProblem doc comment re-attached; Heidenhain credential help text names the
secret:heidenhain/ and env:OTOPCUA_HEIDENHAIN_ namespaces.
- Review 1: RawTreeService Create/UpdateDriver and Create/UpdateDevice refuse a Heidenhain
config whose password fields are not blank / secret:heidenhain/... / env:OTOPCUA_HEIDENHAIN_...
(DriverConfigSaveGate over HeidenhainOptionsParser.DescribeCredentialProblems: top level,
Access, Devices[], case-insensitive keys; the value is never echoed), so a literal password
never reaches the draft DB. The driver and device modals show the reason and disable Save.
- Review 8: CreateTag/UpdateTag/ImportTags (tag modal, manual entry, CSV import, browse commit)
refuse a ReadWrite Heidenhain tag or a Tag.DataType that disagrees with what the driver
publishes (HeidenhainTagRules: catalog type, Float64 => Double, or the binding's dataType).
The tag modal and manual-entry grid fix the access level at Read and derive the data type from
the address (RawTagRowDefaults). New deploy gate HeidenhainTagDataTypeMismatch.
- docs/drivers/Heidenhain.md: credential namespace convention + why, the save-path and deploy
enforcement, optional-role credential behaviour, BadConfigurationError, backoff/ordering notes.
Tests: HeidenhainSavePathTests (service save path; red with the gates disabled) and new
DraftValidatorHeidenhainTests cases.
- Credential exfiltration (review 2): password references are scoped to
secret:heidenhain/<name> and env:OTOPCUA_HEIDENHAIN_<NAME> only. Enforced by
HeidenhainOptionsParser.TryParseCredentialReference (parser, probe, deploy gate) AND again at
resolve time in HeidenhainCredentials (fail closed without consulting the store or the
environment), so Test Connect can no longer send env:ConnectionStrings__ConfigDb or another
subsystem's secret to an arbitrary Host. The probe also refuses an unsendable password.
- Optional-role credentials (review 6): an unresolvable/NUL/non-Latin-1/>247-byte DNC or DATA
credential never sends a login and never fails the session; the reads needing that role are
BadConfigurationError (capability ConfigurationError) and INSPECT telemetry continues. A
policy refusal inside AcquireAsync is per-tag, not a session teardown.
- Start after DisposeAsync is a no-op (review 3); initial subscription push and Publish are
ordered under one lock (review 4); JSON-null sections are normalised and the acquisition loop
catches every fault (review 5); backoff resets only after a session published a poll batch,
with clamped delays (review 7).
Tests: HeidenhainReviewFixTests + namespace/normalisation tests in HeidenhainConfigTests;
each was confirmed red against the reverted fix.
Review of af5c9744:
1. UNS reference variables (s=Area/Line/Equip/Eff) of a moved or renamed
equipment stayed readable/writable under the OLD names' grants: they now
resolve as ReferenceVariable and are authorized at their split path only
while it equals their live equipment folder's placement (live chain ==
generation chain) + one name; otherwise denied (Read and Write).
2. TryPlaceScriptedCondition now also requires the owner folder's live chain
to match the generation (AuthorizeScriptedCondition gains ownerFolderChain),
so a moved equipment's alarm/children/commands follow its folder.
3. Identifiers containing NUL are denied before the decision cache, keeping
client ids disjoint from the NUL-prefixed resolved-scope keys (a client
could otherwise poison a real folder's cached verdict for its key shard).
4. An id no live node holds is Unknown: placed at [\0unknown] so only
Cluster / Namespace-uns grants decide it (a removed opaque id can no longer
split onto a same-named narrow grant; narrow grantees get no NodeDeleted for
removed UNS folders/vtags/conditions — documented); 4-segment
reference-shaped ids keep their split.
5. A wire test drives placements from DeploymentArtifact.ParseDataPlaneAuthority.
Baseline updates: #797 owner tests (unit + wire) and Sdk2RepeatedAlarmAuthority
now install folder scopes; Sdk2HistoryAuthority's UNS alias used the RAW path
as its UNS id (never minted in production) and now carries EqA/HistoryAlias.
Each new guard was falsified (reverting it fails its test).
UNS Area/Line/Equipment folders are minted under their opaque entity ids
(s=UA-/UL-/EQ-...), virtual tags under s=EQ-.../Name and scripted conditions
(+ #629 children) under s=<ScriptedAlarmId>[/...], while every UNS grant is
planted at a NAME path. DataPlaneAuthorizer split those ids, so with
Security:Acl:Enabled a narrow (Area/Line/Equipment) grant could not Browse,
Read, subscribe or HistoryRead them, and Server-object delivery never reached
it — so a narrow key never held the EventId Ack/Confirm/AddComment need.
- The generation carries UnsFolderScopes (folderId -> path + id chain), built
by DeploymentArtifact from the same AclScopePathResolver as the grants; ids
two entity kinds share are dropped; plumbed through IDataPlaneAuthoritySink.
- OtOpcUaNodeManager.ResolveUnsAclSubject reports live facts (folder id
ancestry / scripted owner binding); attached by the Authorizer setter.
- Evaluate places the subject against the CURRENT generation before the
decision cache, which now caches the walk keyed on the resolved scope.
Folders require live chain == generation chain (a moved equipment is denied
under old and new line until the rebuild). Owned nodes (vtags, conditions,
children) get owner path + a reserved segment, so Tag grants and their
Browse transit never expose them. Conditions share TryPlaceScriptedCondition
with the #797 command gate.
- Server-object visibility of a scripted condition is decided on the
condition alone, so a moved alarm cannot reach its old owner there.
Tests: UnsFolderScopeWireTests (opaque ids, end-to-end browse -> EventId ->
Acknowledge on an Equipment grant; sibling denied; Tag-only grant; moved alarm
and moved equipment stale windows). Rig tests now install folder scopes
explicitly (ServerEventRig.FolderScopes); the #797 recreate test deliberately
asserts the moved alarm is invisible to the Cluster observer in the window.
- HeidenhainDeployChecks (wired into DraftValidator): HeidenhainTagWritable refuses a
ReadWrite access level on any Heidenhain tag, so no node is ever advertised writable;
HeidenhainCredentialPersisted refuses a literal password in DriverConfig/DeviceConfig
(only blank / secret: / env: references; the value is never echoed);
HeidenhainConfigInvalid for out-of-range settings or a tagged device without an endpoint.
- EquipmentTagConfigInspector maps Heidenhain to HeidenhainTagDefinitionFactory.Inspect.
- Driver validates only devices that carry tags (an unconfigured default Device1 no longer
faults the driver).
- Lift an Agent's MTConnectError body under a non-2xx status (cppagent 2.x serves
OUT_OF_RANGE as HTTP 400, NO_DEVICE as 404) into the refusal-marked
InvalidDataException, reading at most 64 KiB. The 400 used to be a transport
fault, so the OUT_OF_RANGE re-baseline never ran against a real 2.x Agent.
- Run the instanceId restart test on every re-baseline snapshot: on 2.x a restart
is first seen there (the old cursor gets a 400), and was adopted silently.
- Report the stream Degraded after 3 consecutive re-baselines with no /sample
chunk (it read Healthy for ever); LastSuccessfulRead keeps advancing.
- Prohibit DTDs on the /probe and write-answer parses; bound the streams walk to
64 levels (unbounded recursion = uncatchable StackOverflowException).
- Skip structural elements under <Components>/<Devices> instead of failing the probe.
- Never serve a non-finite float as Good; serve integer-valued decimals on
integral tags losslessly (a real fraction stays BadOutOfRange).
- Merge sibling browse containers that resolve to one folder name.
Unit 678 -> 714, integration 18 -> 20 (live fixture); every gap test failed first.
Native LSV2 TCP transport (default port 19000; no Java/Python/vendor SDK), ported from
the ignitionoee v0.20.3 reference driver:
- Lsv2ReadOnlyPolicy: payload-aware outbound allowlist (A_LG INSPECT/DNC/DATA, R_VR, R_PR,
R_RI 22-28/30-34/51, bounded R_MB, R_DP), applied in Lsv2Codec.Frame before any byte is
written; no public raw-command API.
- Lsv2Client: serialized transactions, one monotonic deadline per transaction, EOF/oversize/
unexpected/trickle close the client; Close never waits on the gate.
- Lsv2Data / HeidenhainBindingCodec: reference decoders, R_PR byte-capacity + element-index
rules, next-area cap, DATA Boolean 00/01/FF, strict non-truncating coercion.
- HeidenhainSession: per-batch wire cache, refusal suppression, provisional DNC denial retry,
alarm cursor (57 = end, overflow = BadOutOfRange), capability strings.
- HeidenhainDeviceRuntime: one loop per control, generation-guarded publication, all-node
BadNoCommunication on comms loss, bounded exponential reconnect.
- HeidenhainDriver: cached ReadAsync, push subscriptions deduped on (value,status), static
catalog discovery (no connect), host status, diagnostics, skipped-tag report. No IWritable.
- Probe (INSPECT login + version) and factory registered in DriverFactoryBootstrap (probe on
admin nodes too); DriverTypeNames.Heidenhain.
Tests: 159 unit tests against an in-process LSV2 simulator incl. the Java fixtures' captured
iTNC 530 replies as golden vectors; env-gated LiveIntegration category for real hardware.
Client.Shared now project-references Driver.OpcUaClient.Contracts (Core.Abstractions
only, no NuGet/SDK; pinned by ContractsIsDependencyLightTests) and delegates the
host/port rewrite to OpcUaEndpointUrlRewriter, deleting its own copy.
The two copies differed; reconciled toward the client so its pinned behaviour is
unchanged (EndpointSelectorRewriteParityTests, written green against the old copy):
- no-op rewrite (same host case-insensitively + same port) now returns the advertised
string verbatim in the shared rewriter too (it re-serialised: added a trailing slash
and case-folded a case-only host difference);
- a real rewrite serialises via AbsoluteUri, not Uri.ToString(), which un-escaped the
advertised path (/x%20y became /x y) in the driver + browser;
- unusable URLs: the rewriter still falls back to the configured URL (driver/browser);
the client keeps its loud failure as call-site validation (null -> InvalidOperation,
unparseable -> UriFormatException).
Review of 3d1b86b4: OpcUaPublishActor installs a new authority generation
before applying its address space, and an apply that throws keeps the old one.
A scripted alarm moved from equipment A to B therefore stayed commandable with
A's grant under B's generation (briefly before the rebuild, or indefinitely
after a failed apply).
The generation now carries ScriptedAlarmOwners (ScriptedAlarmId -> EquipmentId,
decoded by ParseDataPlaneAuthority from the artifact's ScriptedAlarms rows, the
same rows the composition materialises from). AuthorizeScriptedCondition denies
unless the node manager's live binding names the same owner as the generation:
a moved alarm is denied under the old owner's, the new owner's and a Cluster
grant until the address space re-binds it; an alarm the generation no longer
deploys is denied. Install/apply order unchanged.
Tests: window (a) generation moved / binding stale => both owners and Cluster
denied, then rebuild under the new owner => new owner allowed, old denied;
window (b) apply failed after install => denied across clock and further
generations, then a successful rebuild restores the new owner only; undeployed
alarm denied; artifact decode of the owner map.
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.
- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
EquipmentId it was materialised under (only when it hangs under that folder);
dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
[uns, Area, Line, Equipment]) decoded from the artifact by the same
AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
generation per call (uncached) and evaluates at the owner path; unbound,
replaced or unplaceable owners deny under every grant. No id-split or
realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
NodeIds and AlarmCommand.AlarmId are unchanged.
Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808
(folder ids + Server-object event visibility for narrow UNS grants).
The AdminUI OPC UA browse picker connected to the EndpointUrl the server
advertised in GetEndpoints verbatim, so behind NAT / a container port
publish it dialled the server's private hostname + internal port and
failed DNS where the runtime driver (which rewrites per #676) connected.
- Move the rewrite to the shared OpcUaEndpointUrlRewriter (.Contracts,
pure Uri logic, no SDK dependency) and the policy+mode selection to
OpcUaEndpointSelection (.Session leaf). Driver and browser both select
through it, so the browse connects exactly where the driver does.
- Policy/mode filter, server certificate and strict browse PKI
(no auto-accept) are unchanged.
- Unit tests: rewrite (host/port differ, same, IPv6 both sides, path
kept, port-less, scheme mismatch untouched), browser selection seam.
- Live NAT tests (Fixture=opc-plc-nat, OPCUA_NAT_ENDPOINT): browse via a
published port with a premise check that the advertised host:port
differs and does not resolve, nsu= round-trip, unreachable endpoint
fails cleanly, SignAndEncrypt reaches the server and is refused
BadCertificateUntrusted. Verified red without the rewrite.
Refs #806
Owner decisions §14 #5/#6 as built (design §12.5):
- Scripting:Worker:Identity (default unset, Windows only, fail-closed validation): each worker
starts under a restricted token derived from the host's. Every privilege but SeChangeNotify is
removed; the restricting SIDs are NT SERVICE\OtOpcUaScriptWorker's SID + Everyone + Users +
RESTRICTED; the token and default DACLs are host + SYSTEM + identity + RESTRICTED. The worker
is created suspended, put in its Job Object before it runs, inherits only its stdio pipes, gets
an ACL'd work dir as TEMP, and runs with DOTNET_EnableDiagnostics=0. The identity is granted on
the host's window station and desktop, because USER32 init made coreclr.dll fail with
ERROR_DLL_INIT_FAILED on windev. The logon SID is not used because the host's process DACL
gives it PROCESS_VM_READ.
- The worker pipe on Windows always has an explicit protected DACL: host account + identity
only. There is no owner ACE, so an elevated host's Administrators gets no access.
- The worker treats access denied on its parent-pid poll as alive; the Job Object covers that case.
- scripts/install/Install-ScriptWorkerIsolation.ps1 + ScriptWorkerIsolation.psm1 are idempotent
and support -WhatIf, -Uninstall and -PlanOnly. They create the disabled anchor service, the
PeCacheDir ACL (protected, no Users, key and markers host-only, pe\ Modify for the identity),
read+execute on script-worker\, a ReadData deny on the install root, the outbound firewall
block on the worker exe, and optionally the host-service env.
- Tests: the dry-run harness scripts/install/tests/Test-ScriptWorkerIsolation.ps1 (46
assertions, mutation-checked); ScriptWorkerIdentityTests; WorkerIsolationTests, which cover
the pipe ACL, token access and a real restricted worker running a script, all green on windev.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
ForbiddenTypeAnalyzer now denies System.AppContext, System.Console, GCSettings, ProfileOptimization,
EncodingProvider/CodePagesEncodingProvider, TypeDescriptor and CryptoConfig as types, and the ambient
CultureInfo.{DefaultThreadCurrentCulture,DefaultThreadCurrentUICulture,CurrentCulture,CurrentUICulture}
and TimeZoneInfo.ClearCachedData members (member deny-list now covers properties and member-access reads).
Shadow-mode tests diverge via culture-sensitive string.Compare (worker is InvariantGlobalization) instead of
AppContext.BaseDirectory, with a premise test. Mutation-proved: 21 new cases fail with the analyzer reverted.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
- ShadowScriptRunner (Core.Scripting): IScriptShadow.Mirror copies the inputs and queues the shadow run on the
pool; compares value (structural), CLR type, status and failure class (compile / budget / threw+message /
unsupported_type); runner-fault shadow outcomes (Unavailable, worker busy) are not compared. Bounded:
Scripting:Shadow:MaxInFlight (256) and one per script; drops counted (behind | key_busy).
- Metrics otopcua.script.shadow.{compared,mismatch{script},dropped,inflight}; one rate-limited Warning per
script and reason with a diff summary (Scripting:Shadow:MismatchLogsPerMinute, re-armed at the seam's deploy).
- The VirtualTag, Calculation and scripted-alarm seams recognise the shadow and keep their in-process path
byte-for-byte (no coalescer, one-at-a-time pump, in-process engine), mirroring after each compiled run.
- ScriptRunnerSelection builds the shadow over an OutOfProcessScriptRunner whose lines carry
ScriptRunnerRole=Shadow; Status() is null under Shadow so readiness never sees the shadow pool; the
script-runner health entry stays Healthy and reports the shadow counters as data.
- docker-dev/docker-compose.script-runner-shadow.yml; docs/VirtualTags.md "Shadow mode".
- Tests: comparison table, per-script metric + once-per-reason log, rate limit, hung/blocking/throwing shadow
never reaches the caller, MaxInFlight drop accounting, input copy; real-worker divergent + unsupported-type
scripts counted against exactly those scripts, a worker-only runaway killed/quarantined there with every
published value intact, alarm transitions identical to in process across a kill -9 of the shadow worker.
Mutation-proved (16 mutants, 15 red; the one survivor added an assertion).
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
- IScriptRunner.RunBatch: one EvalBatch frame per worker for every evaluation ready to run; per-item, streamed results.
The default (InProcessScriptRunner) is RunAsync per item. Used by the Calculation pump (dequeue all, split at a
repeated tag, publish in dequeue order), the VirtualTag seam (ScriptBatchCoalescer, no timer) and the scripted-alarm
engine (whole dirty set). In process the pump and the engine stay one at a time, unchanged.
- Exact per-item deadlines: the worker hands work to an idle evaluation thread or defers it (EvalResults
deferred_eval_ids); the host stops that run's clock and restarts T then G when it starts (started_eval_ids). A run
queued behind a runaway is neither timed out nor struck and is a victim, not the culprit, at the kill.
- Scripted-alarm seam behind Scripting:Runner:Seams; unset Seams now means VirtualTag + Calculation, so alarms run out of
process only when listed. Load still compiles each predicate (to PE bytes only) so a broken one fails the load; passes
batch and apply in the serial order under the gate. Script faults freeze the condition BadInternalError; runner faults
freeze it BadResourceUnavailable and re-evaluate on recovery; a dead worker never clears an alarm. IScriptRunnerProvider
carries the runner to DriverHostActor.
- Perf harness: batch throughput (RunBatch vs RunAsync x n) and alarm-pass latency (in process / batched / serial);
design §12.3 records macOS + windev. On windev the serial out-of-process alarm pass misses 250 ms from ~500 alarms;
batched p99 <= 53 ms at 1,000.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Proven broken first: VirtualTagToVirtualTagFlowTests (real mux + host + Roslyn
evaluator) failed on master - VT A evaluated, VT B reading A by its key never did.
VT outputs only reached their OPC UA node; the mux carried driver values only.
- VirtualTagHostActor also sends each real result (not re-asserts) and a disabled
tag's BadOutOfService to the mux as VirtualTagOutput, keyed by the VT's UNS
NodeId identifier {EquipmentId}/{Name}. Publish path unchanged (single source).
- DependencyMuxActor pins VT outputs (retained with no subscriber, no grace,
immune to SourceRemoved) and replays them; VirtualTagOutputsRemoved releases
keys that leave the deployed set.
- DraftValidator: blocking VirtualTagDependencyCycle (A->B->A, self-read, loops
through Calculation tags, {{equip}} refs resolved); disabled VTs are not nodes.
EquipReferenceUnresolved names the key form when {{equip}}/<name> is a VT.
- Runtime backstop: the host re-detects VT cycles per apply and does not route
outputs of tags on one.
- AdminUI ScriptTagCatalog lists VTs by key (the bare leaf name never resolved).
- docs/VirtualTags.md documents the routing, key, retention and cycle rules.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Unsubscribe paths now delete through the existing DeleteSubscriptionAsync seam so a test can hold the delete open >grace. Mutation: dropping the post-delete restamp fails both slow-delete tests.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Revises 963b0d66, which dropped a disabled VirtualTag from the runtime plan so a
bound client got BadNodeIdUnknown. Now the plan carries Enabled (part of value
equality): AddressSpaceComposer.Compose and DeploymentArtifact.BuildEquipmentVirtualTagPlans
keep the row with Enabled=false (byte-parity), the applier materialises the node as
normal, and VirtualTagHostActor spawns no VirtualTagActor for it but publishes
BadOutOfService (new OpcUaStatus constant) with a null value stamped at deploy, on
every apply. Enabled flips are node-irrelevant to the change classifier; enabled->disabled
stops the child, disabled->enabled resumes evaluation. Validator exemption and name
uniqueness unchanged. Scripted alarms keep their not-materialised convention.
Tests updated; new wire test DisabledVirtualTagWireTests. docs/VirtualTags.md updated.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV