No read or write loop checked _plcDead between items: on a frozen-but-
established peer the first op blew its deadline and marked the handle dead,
and every remaining span / tag / write still went to the wire and could wait
its own deadline under _gate (a 20-span pass ~100 s), with Degraded and the
comms-loss watchdog's clock deferred until the pass ended.
- The span loop, the multi-var chunk loop, the per-tag loop and the write
loop stamp BadCommunicationError without I/O once _plcDead is set.
- A multi-var chunk that dies on a transport loss (socket / IO / timeout /
ConnectionError) marks the handle dead instead of falling back to one
doomed per-tag read per member. The framing class is deliberately excluded
there: snap7/S7.Net report a multi-var with one refused item as
ReadData(WrongNumberReceivedBytes) over a healthy stream.
- Live gate via an in-test freezable TCP proxy (counts request frames, not
seconds). Mutation shows S7.Net 0.20 already self-closes on a cancelled op,
so the gate pins the end-to-end property; the driver guard itself is proven
by the unit tests (an op that ignores its token keeps the socket open).
Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
A deterministic PLC refusal (object does not exist, address out of range,
type inconsistent...) degraded driver health, and an all-refused driver (a
wrong DB number) sat Degraded with LastSuccessfulRead frozen, so the 90 s
comms-loss watchdog reconnected it forever against a reachable PLC.
- IsRefusal / IsAccessDenied classify over the whole exception chain. Live
probe on the snap7 fixture: S7.Net's READ paths raise the item error as a
BARE Exception ("Received error from PLC: ..."), its write paths as
PlcException(WriteData). The old PlcException-only match missed the read
shape entirely, so a real read access-denied was BadCommunicationError +
Degraded instead of the Faulted PUT/GET alert; the Test Connect probe had
the same blind spot.
- A refusal (read or write) is BadDeviceFailure with a once-per-tag Warning,
no health write and no reopen; it counts as answered, so it advances
LastSuccessfulRead and restores Healthy after a comms fault. An undecodable
buffer (S7ValueRangeException) also counts as answered.
- A write batch the CPU answered without a failure advances
LastSuccessfulRead and retires a Degraded the write side itself published.
- Tests that used ReadData as their generic "device fault" now use SendData
so their Degraded leg is still exercised.
Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The init-time tag guards THREW: one mis-authored tag (DB1.DBZ0, DB1.DBW0 typed
Float64, T5 typed Int32, a writable Bool array) faulted the whole driver and the
actor retried the same init every 10 s forever, darkening every tag on the PLC.
Neither the editor nor the deploy gate checked any of it.
- S7AddressParser moves to S7.Contracts (same namespace) and a new
S7TagShapeRules there is the single authority on servable shapes.
- S7TagDefinitionFactory.FromTagConfig applies it, so the AdminUI editor, the
deploy gate (Inspect, with the specific reason) and the driver init refuse
the same tags. Init now skips a refused tag (ISkippedTagReporter) instead of
throwing; the throwing RejectUnsupportedTagConfigs is gone.
- New rules on top of the old guards: a narrow type at the wrong access width
(every read failed) and a Bool array not starting at bit 0 (U4: DB1.DBX0.3
silently read bit 0 of bytes 0..n).
- AdminUI test fixtures that used addresses the driver could never serve
(DB1.DBS0, a browse "SomeAddress", Int32/Float32 on DBW) now use real ones.
Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- Galaxy: deadline bounds the wait, not the subscribe RPC; BadTimeout for all tags and late handles unsubscribed; doc comment relocated
- S7: probe connect runs on the connect deadline so a timeout opens the backoff window
- S7: a successful write only retires a Faulted the write side owns
- S7: null array elements rejected (BadTypeMismatch); multi-PDU array writes documented non-atomic
- S7 integration: array write test gated on S7_SIM_ALLOW_WRITES=1
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
STAB-21 ConnectionBackoff in EnsureConnectedAsync; STAB-22 write-pass accumulator with a
write-side Faulted that a clean read does not erase; _health on the Volatile idiom;
S7-016 contiguous array write (Bool arrays stay refused).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Replace pre-declared options.Tags (typed <Driver>TagDefinition lists) with
options.RawTags (IReadOnlyList<RawTagEntry>) across all 6 Docker-gated driver
integration suites so they COMPILE against the v3 driver API.
Each project gets a local <Driver>RawTags helper mirroring the unit-test
project's helper: it serialises a typed def back to its TagConfig blob via the
driver's <Driver>TagDefinitionFactory.ToTagConfig and packages it as a
RawTagEntry (RawPath = def.Name; DeviceName = def.DeviceHostAddress for the
multi-device drivers AbCip/AbLegacy/TwinCAT/FOCAS). Test intent (addresses,
data types, device routing, assertions) is unchanged — only the
tag-authoring/config-delivery shape was migrated.
Docker-gated: these still skip at runtime without fixtures; COMPILE is the gate.
The S7 Plc was opened once in InitializeAsync and never re-opened: a transient
PLC reboot / network blip permanently killed the driver until redeploy. Introduce
an IS7Plc / IS7PlcFactory seam (mirrors TwinCAT's ITwinCATClientFactory) and a lazy
EnsureConnectedAsync that disposes a dead handle and re-opens a fresh connection on
the next data call. Reads/writes mark the handle dead on a connection-fatal fault
(socket drop / ErrorCode.ConnectionError) but NOT on a data-address error; the probe
loop routes through EnsureConnectedAsync as a backstop.
The seam also closes the S7 TEST-1 gap — the reconnect state machine is now unit-
testable without a live PLC (S7.Net.Plc is sealed with no in-process fake).
Verification:
- 4 deterministic unit guards (fatal→reopen, data-error→no-reopen, raw socket→reopen,
reopen-fail→degrade-then-recover); full S7 unit suite 234/234 green.
- LIVE end-to-end proof against real python-snap7 (S7_1500ReconnectTests, double-gated
on sim reachability + S7_RECONNECT_BOUNCE_CMD): bounced the container, driver observed
the outage and resumed Good reads with NO redeploy. Baseline smoke 3/3 still green.
Introduces Driver.S7.Contracts (dependency-free POCO project) and moves
S7DriverOptions / S7ProbeOptions / S7TagDefinition / S7DataType into it.
Adds S7CpuType enum mirroring S7.Net.CpuType exactly (7 values with
explicit integer codes). Runtime S7CpuTypeMap bridges S7CpuType →
S7.Net.CpuType at the single Plc construction site in S7Driver.InitializeAsync.
S7DriverFactoryExtensions and S7CommandBase updated to use S7CpuType; test
files updated to match (S7_1500Profile, S7DriverScaffoldTests). AdminUI can
now reference Driver.S7.Contracts without pulling in S7netplus.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.
- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
integration, install).
Build green (0 errors); unit tests pass. Docs left for a separate pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>