Blazor does not serialize OnParametersSetAsync against its own outstanding
task, and the modal's `_open` bool cannot tell two opens apart. ResetAndResolveAsync
awaits LoadMergedProbeConfigAsync and ResolveGroupContextAsync and then wrote
_driverType/_mergedConfig/_effectiveDeviceId/_groupPrefix/_canBrowse/_disabledReason
with no staleness re-check, so a close-reopen onto another device let the first
open's late continuation install its device's browse context under the displayed
modal — "Connect & browse" would silently dial the wrong controller and the commit
would land under the wrong tag-group.
Ports the per-open `_openGeneration` counter proven in the two sibling modals
(RawManualTagEntryModal, RawTagModal, 2026-08-05) to every post-await write here:
after both awaits, in the catch's error banner, and in the finally. The finally is
the one departure from the sibling shape and it is load-bearing — this modal resolves
inside a try/finally, so a stale `return` still runs the tail and would drop the LIVE
open's spinner mid-resolve.
Pinned by four RawBrowseModalStaleOpenTests facts, each observed red before the guard
and each re-falsified afterwards by reverting only its own guard. The modal calls
StateHasChanged on the open path, which throws without a render handle, so the test
attaches an inert Renderer subclass (file-local BL0006 pragma); [Parameter]s are set
by reflection per the BL0005 convention.
AdminUI suite 1117/1117 green.
Follow-up to 20a816db: mxaccessgw published the full MxStatusDetail enum
(gateway.md @ 75c71ad, "MxStatus Detail Vocabulary", lifted from
Interop.aaMxDataConsumer.MxStatusDetail), confirming the live-captured codes
(1007 = MX_E_NotWriteable, 1008 = MX_E_WriteAccessDenied). FromCategory now
maps the write-relevant band per code before falling back to the category
bucket: 1004 -> BadOutOfRange, 1005 -> BadTypeMismatch, 1006 -> BadNotReadable,
1007 -> BadNotWritable, 1008/1012/1013/1016/1017 -> BadUserAccessDenied,
1010/1011 (initializing, transient) -> BadOutOfService. 8000
(MX_E_AutomationObjectSpecificError) deliberately stays category-level — the
object supplies its own semantics. Codes <= 0xFF are value-ambiguous with the
OPC DA quality-byte space and keep the quality path (still Bad-family).
Four new named constants, all validated by StatusCodeParityTests against the
pinned SDK. Live refusal smoke re-run green (read-only refusal now surfaces
BadNotWritable instead of generic Bad).
The mxaccessgw OnWriteComplete correlation is live (server b948e69, worker
53f69cd — all four unary write kinds), so every write reply's statuses[0] now
carries the real COM commit outcome. Live-gating the cutover on windev found
and fixed three defects:
- StatusCodeMap.FromMxStatus truncated the correlated failure row's MxStatus
detail code to a byte (1007 & 0xFF = 239 -> OPC DA Good band), mapping a
REFUSED write to Good. New invariant: a row that is not IsSuccess() never
maps Good — details > 0xFF (and contradictory Good-band substatuses) route
by category (SECURITY_ERROR -> BadUserAccessDenied, named const covered by
StatusCodeParityTests; COMMUNICATION/CONFIGURATION keep their codes).
- The borrow-from-subscription-registry write optimization could never commit:
a subscription handle is plain-advised, and MXAccess refuses both the
no-login write through it (SECURITY_ERROR detail 1008, live-captured) and
the supervisory advise upgrade (E_INVALIDARG) — one advise per HANDLE, not
per attribute. Removed: writer subscribedHandleSource ctor param + borrow
branch, GalaxyDriver wiring, SubscriptionRegistry.TryResolveItemHandle +
its forward index and test file. The writer always AddItems its own
supervisory-advised handle, which commits fine while the same attribute is
subscribed (live-proven; pinned by the new write-while-subscribed smoke).
- (gateway-side, fixed there) the correlation initially covered WriteSecured
only, while the dominant no-login path emits plain Write.
Live gate, all legs PASSED against windev: happy write Good off a confirmed
status row with galaxy.writes.unconfirmed + advise_failed both FLAT; read-only
refusal surfaces Bad-family (the #5 node-revert input Galaxy could never
produce before); WriteCompletionWaitMilliseconds=0 control -> provisional Good
+ metered unconfirmed (override removed after, restoration re-verified). New
env-gated smokes: Live_correlated_write_statuses_confirm_commit_and_surface_refusal,
Live_write_to_subscribed_tag_commits_via_own_handle (replaces the borrow
smoke), GatewayGalaxyWriteMeterLiveTests (run filtered — meters are
process-wide).
The connect path was the one capability call the resilience pipeline never
saw, so a driver that could not connect contributed zero breaker input and
the /hosts resilience panel read 'All targets healthy' against a dead
endpoint. InitializeAsync now routes through the invoker as
DriverCapability.Initialize, keyed on the driver-instance id.
- No pipeline retry: the actor's RetryConnect timer is the retry loop
(parser forces retryCount overrides to 0, same funnel as write-shaped).
- Breaker threshold 2, not the Read-sized 5: the breaker samples 30 s and
the reconnect timer fires every 10 s, so at most three attempts fit one
window — threshold 5 could never open. Pinned by its own test.
- An open breaker fast-fails into the same InitializeFailed path as a real
connect failure; the 15 s break window costs at most one extra tick.
The best-effort teardown ShutdownAsync stays unwrapped.
- Companion fix: DriverCapabilityInvokerFactory.Create now invalidates the
instance's tracker snapshots with its pipelines — a respawn during an
outage discarded the only breaker whose OnClosed could clear the OPEN
flag, stranding a false 'Breaker OPEN' chip forever.
Live gate PASSED on docker-dev (image symbol-verified per container):
rtu-gate against dead 10.100.0.35:5021 opened its Initialize breaker on
both centrals with the red 'BREAKER OPEN' chip on /hosts; a socat
5021→5020 forwarder recovered it (both breakers closed within 1 s, panel
back to 'All targets healthy'); healthy MAIN-modbus recorded zero breaker
events. Full suite 50/50 green. Evidence:
docs/plans/2026-08-07-adminui-followups-and-live-gates.md §7.
The Secrets:Replication _comment claimed the feature was KNOWN NON-FUNCTIONAL
against ZB.MOM.WW.Secrets.Replicator.AkkaDotNet 0.2.0 and said "do not enable
until the library is fixed". That has been false since 0.2.2 — 0.2.1 fixed the
shadowed ISecretReplicator registration and 0.2.2 the hosted-process DI
deadlock — and the 2026-08-07 three-mesh live gate proved replication works
(PASS 4/4, docs/plans/2026-08-07-secrets-pair-local-live-gate.md).
Replaced with the truthful operator-facing note: functional since 0.2.2, still
default-off, PAIR-LOCAL in scope (mesh Phase 6 gives each application cluster
its own 2-node mesh, so a secret converges within its pair and nowhere else),
same KEK required per pair, and rewrap-all runs per node because re-wraps do
not replicate.
Comment-only; no behaviour change.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
A CNC can report duplicate sibling names — the wonder Makino returns two
axes both called AA — which made the Axes/ subtree untrustworthy: the
browser offered two identical folders the commit gate had to refuse, and
the poll loop's name-keyed snapshot cache let the second axis silently
overwrite the first. Spindles and servo loads had the same collision in
their own keying, plus a resolve-to-first-match on the spindle read path.
Scheme: every member of a collision set gets a 1-based occurrence-ordinal
suffix in slot order (AA_1, AA_2); unique names stay bare. Chosen over the
alternatives deliberately:
- Names, not slot numbers, stay the primary identity — the segment map is
re-derived from the live device each session, so a name-keyed path
follows the physical axis across config changes, where a slot-qualified
path would silently rebind on any axis-list shift and rename every axis
on every machine for one pathological CNC.
- The WHOLE collision set is suffixed: bare AA ceases to exist when
ambiguous, so a tag authored against it reads BadNodeIdUnknown rather
than one arbitrary axis's data — the #534/#540 silent-wrongness class.
- Occurrence ordinal, not absolute slot: inserting/removing an unrelated
axis never renames an existing duplicate pair. If the collision-set
membership itself changes, segments change on the next browse and stale
authored segments read Bad, never another axis's data.
One pure helper (FixedTreeNames.Disambiguate, collision-proof against
genuine names by suffix escalation) feeds FocasFixedTreeCache.AxisSegments
/ SpindleSegments, and the emitter, axis snapshot keys, servo-load keys
(cnc_rdsvmeter answers in slot order, so the k-th AA load belongs to the
k-th AA axis) and the spindle read resolution all consume those — they can
no longer disagree. The nameless-spindle S{n} fallback applies before
disambiguation so a fallback name colliding with a real one is handled
like any other duplicate.
Tests are red-first on the pre-fix driver (all five driver-level tests
fail on master's code): browse emits AA_1/AA_2 and no bare AA, each
duplicate reads its own position and servo load, duplicate spindles
resolve per slot, bare AA reads Bad. The wire half runs live against
focas-mock (duplicate names survive the managed wire parse and publish as
suffixed segments); the mock's dynamic store is name-keyed so the
distinct-values half stays with the offline tests. FOCAS 327/327,
integration 11/11, FOCAS.Cli 52, AdminUI 1113, ControlPlane 231.
Closes#548.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
The two discovery-path libplctag tags (@tags symbol-list enumerator, @udt
template reader) still passed the bare Gateway host, so a browse against a
device authored on a non-default port silently browsed whatever answers on
44818 — #534's defect surviving in its discovery half. Both sites now consume
AbCipTagCreateParams.LibplctagGateway, with the Tag construction extracted
into internal static builders so the seam is unit-assertable (the #534 tests
pinned the property's composition but nothing pinned each site's consumption,
which is exactly how these two survived).
New guard: LibplctagGatewayConsumptionGuardTests scans both AB drivers'
sources and fails on any libplctag Tag built from the bare Gateway, so a
future call site cannot reintroduce the silent 44818 redirect.
Live-gated against the fixture host: browse of ab://10.100.0.35:44818
returns the nine-tag symbol table; browse of ab://10.100.0.35:44999 (nothing
listening — the issue's exact repro) now fails ErrorTimeout where it
previously returned the 44818 fixture's table.
Closes#539.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
ConfigServeAuthInterceptor and LocalDbSyncAuthInterceptor gained HasExactlyOnePublicConstructor
pin tests in this branch but lacked the sibling-standard <remarks> paragraph naming them
(TelemetryStream/MeshCommand/CentralCommand all carry it). Cosmetic consistency item from the
#543 code review.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
The proxyOptions local in WithOtOpcUaControlPlaneSingletons was already unused on master
(pre-existing dead code, not orphaned by the deletion commit — every registration passes
singletonOptions); removed while the file is open. The phase-6-1 compliance script still
Assert-Deferred'd the FleetStatusHub /hosts follow-up — an item that is now deleted, not
deferred — replaced with a retirement comment.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
DriverStatusPanel decides whether to subscribe exactly once, in
OnInitializedAsync (`if (!Enabled) return;`), and exposes no OnParametersSet
hook. The detail row was keyed only by DriverInstanceId, so a live config edit
that flipped a row's Enabled true->false — surfaced on the page by the 5 s
LoadConfigAsync refresh — reused the same panel instance: the markup correctly
switched to "Disabled - not deployed" while the panel's two store SnapshotChanged
subscriptions and its 5 s staleness timer stayed wired underneath, until the
operator happened to collapse the row.
Including the flag in the detail row's key recycles the component instead. Both
directions verified against the panel's own lifecycle: true->false disposes the
old instance (unsubscribing both stores, draining both timers) and mounts one
that skips subscription setup entirely; false->true disposes an instance that
never subscribed (the unsubscribes are no-ops, both timers null) and mounts one
that subscribes and primes from the stores.
The data row's key is unchanged. No behaviour change when Enabled is stable.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
#542 filed FleetStatusBroadcaster as blind to site nodes since the Phase 6 per-cluster mesh
split: it derives "the fleet" from central's own Akka gossip ring, which after the split is
just central's own pair. Scoping the cross-mesh rewrite found the deeper truth — the whole
chain is dead end to end, so this deletes it rather than reviving it.
- Zero consumers. FleetStatusBroadcaster published FleetStatusChanged on the DPS
"fleet-status" topic; FleetStatusSignalRBridge forwarded it to FleetStatusHub
("/hubs/fleet-status"); nothing anywhere connected. The AdminUI bans self-connecting
HubConnections, no browser JS subscribes, and /fleet (Fleet.razor) reads
NodeDeploymentState from the ConfigDb plus IClusterRoleInfo on a 5 s poll instead.
- Its second input never existed. DriverHostStatusHeartbeat had no production sender —
only the broadcaster's own test told it — so CurrentRevision was always null and the
30 s staleness -> Degraded flip could never fire.
- Post-Phase-6 DPS is pair-local, so even the central-only view it did produce was an
accident of topology rather than a design.
The fleet visibility that actually works is unchanged and already cross-mesh-correct:
/fleet over NodeDeploymentState, and the four Phase 5 per-node telemetry dials.
Precedent for deleting inert machinery rather than activating it: #522 (driver stability
tiers), #507 (discovered-node injection), #525 (GetMemoryFootprint).
Deleted: FleetStatusBroadcaster (+ its nested DriverHostStatusHeartbeat), its admin
singleton registration and FleetStatusBroadcasterKey, FleetStatusSignalRBridge and its
key, FleetStatusHub and its route mapping, and the FleetStatusChanged / FleetNodeStatus /
FleetNodeHealth messages. Both Fleet/ directories survive — ControlPlane keeps
ClusterNodeAddressReconciler, Commons keeps GetDiagnostics. Docs swept where they claimed
a fleet-status channel exists (Telemetry.md's Phase 5 non-migrated channels,
Configuration.md, CLAUDE.md); completed-program plan docs under docs/plans and docs/v2 are
left as the historical record they are.
Build 0 errors, 868 warnings — byte-identical to master's rebuild baseline.
ControlPlane.Tests 231/231, AdminUI.Tests 1109/1109.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
DriverStatusPanel was orphaned — zero references repo-wide — so the Restart and
Reconnect driver commands had NO reachable UI at all, despite working end to end
over the new gRPC mesh transport. Nothing failed to build, test or deploy while
that was true, which is why it went unnoticed.
The panel is now reachable per driver row on /hosts, behind a per-row "Controls"
expander that is collapsed by default: the table stays scannable, and only the
opened panels hold snapshot-store subscriptions. Expansion state is a HashSet
keyed by DriverInstanceId held on the page, so it survives the 5 s refresh that
replaces every row record. Both rows are @key'd by instance id so the panel —
which binds its DriverInstanceId once in OnInitializedAsync — can never be diffed
onto a different driver.
The panel's Enabled parameter is fed from real config rather than defaulted:
HostsDriverInstanceInfo/HostsDriverRow now carry DriverInstance.Enabled, which
LoadConfigAsync already had in hand. A snapshot with no matching configured
instance is treated as enabled — the row exists only because live health arrived,
so "Disabled — not deployed" would contradict the same row.
The expander is visible to every AuthenticatedRead viewer; the panel self-gates
only its Reconnect/Restart buttons on DriverOperator.
A source-scan pin (HostsPanelWiringTests) asserts /hosts still renders the panel
and still binds it to the row's own driver, cluster and enabled state — removing
the tag would silently restore the orphaned state.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
TelemetryStreamAuthInterceptor, ConfigServeAuthInterceptor and
LocalDbSyncAuthInterceptor all decided "is a key configured?" with
string.IsNullOrEmpty. A whitespace-only configured value therefore passed
that guard and fell through to the constant-time comparison — where it is
satisfied by a whitespace-only bearer token. The gate would be open to
anyone who guessed a blank credential.
This backports the check the two NEW mesh interceptors already use:
MeshCommandAuthInterceptor (and its central-side clone) validate with
string.IsNullOrWhiteSpace, so the four/five planes now answer the same way
to the same misconfiguration. Nothing else changes — the denial status
codes (PermissionDenied / Unauthenticated / PermissionDenied respectively)
and every denial message are untouched, and no key material is logged.
No deployment configures a whitespace key: the docker-dev rig and
production both set real keys, so this is a fail-closed hardening of an
unreachable-today misconfiguration rather than a live exposure.
Tests: each of the three test files gains a ..._WithBlankKeyConfigured_IsDenied
fact mirroring MeshCommandAuthInterceptorTests.ExecuteMethod_WithBlankPskConfigured_IsDenied
(configured key " ", presented "Bearer "), verified red before the fix.
ConfigServeAuthInterceptor and LocalDbSyncAuthInterceptor also gain the
HasExactlyOnePublicConstructor pin their two siblings already had —
Grpc.AspNetCore silently stops invoking an interceptor with more than one
public constructor, which would disable auth without failing anything.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
MeshPaths.CentralCommunication / .NodeCommunication (the "/user/..." full-path constants) had
ZERO production consumers after the ClusterClient deletion: both gRPC services resolve their
comm actor through ActorRegistry by typed key, never by ActorSelection over a path. Only the
path-probe test still read them, while the class doc went on calling them "the wire contract
of the central↔node boundary" — a claim that stopped being true the moment nothing addressed
an actor across a process boundary by name.
- The two full-path constants are deleted; the two Name constants remain.
- MeshPaths' doc now says what it is (the local actor-naming convention the registry-keyed
services are spawned under) and records what it stopped being, so the next reader does not
re-derive a contract from the file's history.
- MeshCommActorPathTests composes "/user/" + Name itself — the absolute path is that test's
own addressing detail now, not something the product declares. Renamed
Both_mesh_comm_actors_exist_at_their_contract_paths ->
..._are_spawned_under_their_declared_names, because what it still pins is that the two
registration sites actually ran on a real booted node; a rename is now a compile error, so
"contract" was the wrong word for what would break.
- NodeCommunicationActor's summary no longer cross-references the deleted constant or calls
the name an address. CentralCommunicationActor was checked and makes no such claim.
MeshGrpcBoundaryTests replaces the MeshClusterClientBoundaryTests deleted in step 1. Three
self-seeded single-member clusters sharing the ActorSystem name, joined ONLY by gRPC, driving
the REAL CentralCommunicationActor -> MeshGrpcCommandDialer -> Kestrel h2c ->
MeshCommandAuthInterceptor -> NodeCommandGrpcService -> NodeCommunicationActor -> EventStream:
1. No_cross_mesh_Akka_association_forms_between_central_and_either_site — the program's own
point, kept as a test rather than a live-gate note: each cluster stays single-member and
none ever holds another's address as a member.
2. One_dispatch_through_central_reaches_a_node_in_every_cluster_mesh — the fan, with each
site holding its OWN per-cluster PSK, so a dial that selected the wrong cluster's key
would be refused at the far side.
3. Falsifiability_control_a_dial_carrying_the_wrong_cluster_key_delivers_nothing — without
it, (2) cannot distinguish "the gRPC boundary carried it" from "something else in the
process did". The same node then accepts the right key, so the silence is the auth gate
and not a dead endpoint.
All three run fully offline — no Docker fixture — and pass.
Comment sweep across every remaining clusterclient|receptionist hit in src/ and tests/:
the program label becomes "mesh gRPC command plane", and every comment that described the
deleted transport as live now describes what actually runs (Dps = pair-local default,
Grpc = cross-mesh). mesh_transport.proto's header/service comments are reworded; no message,
field or enum is touched — the contract is locked. MeshCommActorPathTests is reshaped rather
than retired: the two paths still exist and still matter, but what a mismatch costs is now a
misleading Unavailable from the gRPC ingress rather than a silently dropped receptionist send.
The only surviving mentions of the old names are the ones that must survive: the fail-closed
rules that name "ClusterClient" as a retired value refused at boot, their tests, and this
test class's own account of what it replaces.
MeshTransportOptions.ModeClusterClient is gone. MeshTransportOptionsValidator accepts Dps or
Grpc and nothing else, so a node left carrying the string "ClusterClient" is now REFUSED at
boot naming MeshTransport:Mode and both remaining values — deliberately fail-closed rather
than falling back to Dps, which on a split-topology node would deliver nothing at all. A new
fact pins exactly that.
SplitTopologyTransportValidator tightens from an allow-list of two to Grpc only, as its own
comment said it would once ClusterClient was deleted. Dps on a cluster-role node stays
refused; the rule is still an explicit allow-list, so a typo'd mode fails too.
Tests: the two ClusterClient-mode facts in MeshTransportOptionsValidatorTests are deleted
(their Dps siblings already assert the same rule for the one remaining non-Grpc mode), the
SplitTopology fixtures move to Grpc, and the three-mode Theories in
ControlPlaneStarterOrderTests / CentralCommunicationActorTests become two-mode.
The property, the four validator rules that graded it (empty / non-akka.tcp / actor-path
suffix / one-bad-among-good) and all twelve docker-compose entries (6 nodes x 2) are gone.
The compose comment blocks that explained "/system/receptionist is appended at construction
time" and the client's contact rotation go with them, and the surrounding prose now
describes the Grpc command plane it actually runs.
CentralGrpcEndpoints' doc no longer says it "replaces" the Akka contact points — there is
nothing left to replace — and ContactRefreshSeconds' failure message names the node
dispatch set rather than the ClusterClient contact points.
`rg CentralContactPoints src tests docker-dev` is now empty.
akka.extensions loses ClusterClientReceptionistExtensionProvider and the whole
akka.cluster.client block (buffer-size / reconnect-timeout / receptionist.role) goes with
it. The DistributedPubSub extension and the maximum-frame-size / log-frame-size-exceeding
canary both stay — DPS is the pair-local transport and the frame canary guards every
remoting message, neither of which the cross-mesh deletion touches.
MeshTransportHoconTests drops its three ClusterClientSettings/ClusterReceptionistSettings
asserts and keeps the frame-size pin and the DPS-extension pin, renamed since it no longer
has a receptionist to survive alongside.
Central's CentralCommunicationActor and a node's NodeCommunicationActor no longer register
with a receptionist; the ActorRegistry entry each already carried is now the whole
reachability story, and it is what CentralCommandGrpcService / NodeCommandGrpcService
resolve to hand an inbound message over. Both `using Akka.Cluster.Tools.Client` directives
are gone with them.
WithOtOpcUaRuntimeActors no longer builds a ClusterClient from
MeshTransport:CentralContactPoints, and NodeCommunicationActor.Props takes only the gRPC
IApplyAckSender. The ackRouter gate narrows from `useClusterClient || useGrpc` to `useGrpc`,
and the CentralClusterClientName constant is gone.
NodeCommunicationActor's no-transport warning now names MeshTransport:CentralGrpcEndpoints
and MeshTransport:Mode only — the old text pointed an operator at a key that no longer
exists.
Ripples in this step: the two ClusterClient-shaped facts in NodeCommunicationActorTests
(Send-not-SendToAll, and sender-wins-over-a-client) are deleted — the first has no subject
left, the second guarded a both-transports-present state that is now unconstructible. The
Runtime ServiceCollectionExtensions fact keeps its ackRouter pin and drops its
"no ClusterClient actor exists" half for the same reason.
IMeshClusterClientFactory/DefaultMeshClusterClientFactory are gone, along with
CentralCommunicationActor's _clients map, RebuildClient, the SendToAll fan and the
receptionist-address half of the contact load. LoadContactsFromDb SURVIVES — it feeds the
gRPC dialer's endpoint resolution and the known-cluster gate — but now projects only the
columns those two need (the AkkaPort/ActorPath.TryParse parse and its Malformed list went
with the receptionist addresses).
Ripples fixed in this step because the build must be green at every commit:
- ControlPlane/ServiceCollectionExtensions drops the factory argument.
- CentralCommunicationActorTests: the six ClusterClient-only facts are deleted (each has a
Grpc counterpart that already asserted the same property independently), the three
transport-agnostic facts move to Grpc mode, and the Dps fact keeps its own coverage.
- MeshClusterClientFactoryTests deleted (its subject is gone).
- MeshClusterClientBoundaryTests deleted here rather than in step 7: it drives
DefaultMeshClusterClientFactory directly, so it cannot compile past this commit. Its
replacement, MeshGrpcBoundaryTests, lands in step 7 and keeps the load-bearing assertion
(two separate meshes, no cross-mesh Akka association).
Follow-up to a94eb8a3, addressing CHANGES REQUESTED on code review. Production
logic was confirmed correct on all spec points; this commit fixes the review's
test/comment findings only.
IMPORTANT-1: A_permanently_unresolvable_pskProvider_is_reported_once_per_incarnation_not_once_per_refresh
did not prove the second refresh ran — its Expect(0) window gated on a dialer
dispatch landing, but LoadContactsFromDb is fire-and-forget and the first
block's AwaitCondition already re-Tells MeshCommand per poll, so the dialer
call count could reach the threshold before PublishKnownClusters was ever
re-invoked by the second load. Fixed by having the PSK factory count its own
invocations and gating both AwaitConditions on that count directly (pskCalls
>= 2 proves the first retry; pskCalls > pskCallsAfterFirstLoad, awaited INSIDE
the Expect(0) window, proves the second one). Bite-checked: with
_pskProviderAbsenceReported's guard temporarily removed, the test now
correctly fails ("Received 1 message too many... received 1 that matched
filter"); guard restored and reverified green.
MINOR-2: reworded four comments (CentralCommunicationActor.cs ~109, ~259,
~305-309, ~853) from narrating the change ("this fix removes", "already
existed, unchanged", "added by this fix", "the old two-call-site shape") to
stating the timeless invariant.
MINOR-3: added A_supplied_dialer_factory_that_always_throws_still_drops_each_command_loudly_while_PreStart_stays_quiet
— the symmetric case to the existing never-supplied-dialer test, exercising
Resolve's catch + firstUse:true path (a factory that WAS supplied and always
throws) rather than the null-factory path. Asserts PreStart plus the first
contact load stay silent and DispatchOverGrpc's existing per-dispatch Error
still fires on every dispatch, unguarded.
MINOR-4: "Check the ControlPlane registration wires IMeshPskProvider" ->
"Check that the ControlPlane registration wires up IMeshPskProvider"; no test
pinned the old substring, so no test update was needed for this one.
Skipped item 5 (restart-re-arms pin) per instruction — out of scope.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
PreStart's eager resolve of IMeshCommandDialer/IMeshPskProvider loses a
millisecond-wide race against the Akka builder's remaining starters on
essentially every admin boot (live gates: 1A 2/3 boots, 1B 4/4 boots) and
self-heals at the memoized Dialer/PskProvider properties' first use. Before
this change that produced two FALSE Errors per healthy boot, which made a
soak error-grep on a healthy rig impossible.
Resolve() now takes a `firstUse` flag and logs at Debug on BOTH call sites
(PreStart and the memoized properties' retry) — from inside Resolve a lost
race and a genuinely broken factory are indistinguishable, so severity is
decided by the CONSUMER of a still-null result after the retry, not by
Resolve itself:
- Dialer: DispatchOverGrpc's existing per-dispatch Error ("no command
dialer is wired") is unchanged and is now the ONLY loud signal for that
dependency.
- PskProvider: PublishKnownClusters gained a new Error carrying the old
PreStart guard's diagnostic content (gate never published, cached keys
never dropped, rotated key needs restart), guarded to fire ONCE per
actor incarnation via `_pskProviderAbsenceReported` — that handler runs
on the contact-refresh timer for the actor's whole life, so an
unguarded Error there would repeat every ContactRefreshSeconds forever.
Design choice for the "factory never supplied" case (Dps/ClusterClient test
constructions that pass no factories at all): kept silent at BOTH call
sites for both dependencies, same as before. For the dialer this was
already true (DispatchOverGrpc's check doesn't care why the dialer is
null). For the PSK provider the new once-guarded Error is gated on
`_pskProviderFactory is not null` specifically so the many existing
ClusterClient/Dps facts in CentralCommunicationActorTests that never wire a
PSK provider (using the bare Spawn helper) keep passing unmodified — a
never-supplied factory is a deliberate wiring/test choice, not a resolve
failure, and Resolve() already stayed silent about it for the same reason.
Two new tests pin the net behavior: a healthy boot (factories that throw
once then succeed) produces zero Warning/Error end-to-end through PreStart,
the first contact load and the first dispatch; a permanently-broken PSK
provider logs the absence exactly once across two contact loads, not once
per refresh.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
CRITICAL. The ack deadline was one absolute DateTime computed once for the whole
endpoint walk. Against the characteristic WAN failure — a central that HANGS
(SYN black-hole, frozen host) rather than refusing — endpoint 1 burned the whole
AckTimeoutSeconds and endpoint 2 was then dialled with a deadline already in the
past: instant DeadlineExceeded, no packet leaving the node, the surviving central
never really tried. Failover looked like it ran and did not. It also contradicted
MeshTransportOptions' own documented "applied per endpoint, not per ack". The
deadline is now computed fresh inside the loop; headers stay hoisted (read-only,
sequential walk).
Two test gaps that let that survive are closed: nothing pinned the ackRouter gate
(narrowing it back to ClusterClient-only compiled and passed every test while
dead-ending every Grpc ack to DPS), and the deadline fact's lower bound accepted
any positive timeout at all. Both new pins are mutation-verified.
Docs corrected where they overstated the case: duplicate acks CANNOT mis-seal a
deployment — ConfigPublishCoordinator.HandleAck keys _acks by NodeId behind an
expected-set guard, so a duplicate overwrites its own entry. The single-endpoint
rule is defence in depth and a bound on wasted work, not a correctness
dependency; and the walk is at-least-once on the deadline path, not at-most-once.
Task 1B.2 — the node→central half of the ClusterClient→gRPC migration.
GrpcApplyAckSender walks MeshTransport:CentralGrpcEndpoints in order and
STOPS AT THE FIRST SUCCESS. That single `return` is the whole single-count
guarantee: the transport it replaces was ClusterClient.Send, deliberately not
SendToAll, because both central nodes forward to the SAME
ConfigPublishCoordinator singleton proxy — an ack posted to both would have the
coordinator count one node twice and could seal a deployment on a doubled count.
The list is an availability list, not a fan-out list.
No retry beyond that one ordered pass, no queue: the receptionist buffered
nothing and retried nothing, and this is like-for-like, not an upgrade to
delivery guarantees. All endpoints failing is still a DROP — but a loud one,
naming the node, deployment, correlation id and the status each endpoint
answered with, which is what separates "central is down" from "central rejected
this node's key". The bearer never reaches a log; only endpoints and status
codes do. Per-endpoint GrpcChannel cache and the endpoint loop clone
GrpcDeploymentArtifactFetcher; the cluster id in x-otopcua-cluster comes from
this node's own cluster-<id> role via RoleParser, off the same bound
Cluster:Roles ClusterRoleInfo reads.
SendAsync never throws: the caller discards the task, so an escaping exception
would become an unobserved fault — a drop with no log line, the exact failure
mode this migration removes.
NodeCommunicationActor gains an OPTIONAL ackSender; every existing test compiles
and passes unedited. It is checked before the ClusterClient so the two can never
both fire. The registration arm creates no ClusterClient under Grpc.
NOTE — one wiring change beyond the actor: DriverHostActor's ackRouter is now
`useClusterClient || useGrpc ? nodeComm : null`. Left at ClusterClient-only, a
Grpc node's ack would have gone out on the DPS deployment-acks topic and never
reached the sender at all.
Two review items from Task 1B.1, both diagnostic:
1. CentralCommandGrpcService's "actor not ready" Warning omitted the peer and
the correlation id while the decode-failure Warning six lines above carried
both. These are the only two ways an ack fails to reach the coordinator, and
an operator has to correlate either against the node's own log. Decoding has
already succeeded on this path, so the DECODED correlation id is free.
2. A fused driver,admin,cluster-MAIN node under Mode=Grpc owes BOTH validator
surfaces at once (driver keys AND ConfigServe:GrpcListenPort). The two blocks
are independent `if`s; chained as `else if` a fused central node would be
graded on one surface only and boot with nowhere for any ack to land. Pinned
from both sides plus the fully-configured pass.
Phase 1A live gate defect 4. Neither central node booted on this branch,
in ANY transport mode:
Akka.Hosting.MissingActorRegistryEntryException: No actor registered
for key ...ControlPlane.AuditWriterActorKey
at AdminUI.Audit.ActorAuditWriter..ctor(ActorRegistry registry)
at ControlPlane.ServiceCollectionExtensions.<WithOtOpcUaControlPlaneSingletons>
WithOtOpcUaControlPlaneSingletons' first WithActors starter resolved
IMeshCommandDialer and IMeshPskProvider eagerly for the Props. Their
graph reaches back into the registry — dialer -> IMeshPskProvider ->
ISecretResolver -> AddZbSecrets -> IAuditWriter -> ActorAuditWriter,
whose ctor calls registry.Get<AuditWriterActorKey>() — and
WithSingleton<AuditWriterActorKey> is registered ~60 lines LATER in the
same builder. Boot died before the entry existed. Mode-independent: the
resolve happened before anything consulted MeshTransport:Mode, so Dps
(the default, and the rollback target) died exactly like Grpc.
Both dependencies now arrive as Func<> and are invoked in PreStart, by
which point the host is fully built — the same shape, for the same
class of reason, as the coordinator proxy Func one argument earlier.
PreStart re-resolves on restart rather than caching across one; both
are container singletons, so a restart gets the same instances. A
resolution throw is caught and logged rather than propagated: a throw
out of PreStart is an actor failure, the supervisor answers it with a
restart, and a broken DI graph is not transient — that is an unbounded
restart loop that would take the transport-independent ack path down
with it.
Regression pin: ControlPlaneStarterOrderTests boots a REAL admin host
through WithOtOpcUaClusterBootstrap + WithOtOpcUaControlPlaneSingletons
in production starter order, with the production graph from
IMeshCommandDialer down to a registry-bound IAuditWriter, and asserts
StartAsync itself — the failure occurs while the builder's starters
execute, so building a ServiceProvider and resolving by hand cannot
reproduce it. Verified RED against the eager resolve: 3/3 modes fail
with MissingActorRegistryEntryException. A second fact pins that the
deferral did not become 'never resolved' — the actor must resolve the
provider from the container and drive it through the contact refresh,
signalled by a TaskCompletionSource (PreStart runs on the actor thread
and the contact load is a piped DB read, so no synchronous assertion
after StartAsync is correct).
Why nothing caught this: the dialer's container-activation test resolves
from a collection with no secrets registration, so its graph stops one
hop in; the actor facts inject fakes and never touch DI; and the
existing whole-host boots register no mesh provider, so the eager
lookups returned null and walked nothing.
Two aggravators recorded by the gate, no code here: the failed process
did not exit (docker Up while /health/ready 503s — Phase 2 readiness
concern, tracked), and this is the third instance of the same
eager-resolve-during-AddAkka class after scadaproj#1 and mesh Phase 6's
IClusterRoleInfo boot crash.
ControlPlane.Tests 236 -> 240, Host.Tests 92, Cluster.Tests 184,
0 warnings in every touched project.
The known-cluster gate published only under Mode=Grpc, but the
interceptor it feeds is registered on every admin node and 1B maps
CentralCommandService by LISTENER PORT — neither consults the mode. A
dark-switch rollback to ClusterClient or Dps would therefore have left
that endpoint serving with the gate permanently inactive, silently
restoring both the timing oracle and the pre-auth secret-store/audit
flood, as a side effect of a rollback nobody would connect to
authentication. The gate is central's cluster inventory, not transport
state, so it is now decoupled from the mode entirely:
- SetKnownClusters + InvalidateAll run on EVERY successful contact load
in EVERY mode, and the contact-refresh timer starts in all three.
Under Dps this is a ConfigDb query every ContactRefreshSeconds that
did not run before; central always has a ConfigDb, and one indexed
read a minute is the cheaper half of the trade.
- The GATE set is built from ALL ClusterNode rows. The eligibility
filter moved out of the query's WHERE and into the loop, so the FAN
set is byte-for-byte what it was (enabled && !maintenance) while the
gate widens. This also dissolves the maintenance coupling flagged in
1A.2: a cluster whose nodes are all disabled or in maintenance can
still ack, and refusing it would make maintenance mode an
authentication switch. Central still refuses clusters it has never
heard of.
- HandleContactsLoaded keeps a documented order — targets adopted, gate
published, cache dropped — now pinned by test.
Guards: PreStart mirrors the null-dialer error for a null PSK provider
(silent absence is the worst outcome there — nothing malfunctions, so
nothing is investigated, while the gate never publishes and keys never
rotate); a failed contact load now says out loud that the gate is stale
and, before any load has succeeded, inactive; MeshGrpcCommandDialer
clamps a non-positive DispatchTimeoutSeconds to 10 with a construction
Warning, because the validator for that key is driver-role-scoped and a
pure-admin central reads it unvalidated; the dialer's local PSK refusal
was shortened so its remediation survives the actor's 200-char
truncation of remote-authored status detail; the portless-node warn-once
set is rebuilt each refresh, so a node that regains then loses a port
warns again — the regression is the occurrence worth seeing.
Docs/pins: dialer disposal comment no longer claims one-way; the two
interceptor-test comments claiming Matches has a default implementation
corrected (it deliberately has none); new pins for per-refresh
invalidation, the SetKnownClusters-before-InvalidateAll order, and one
channel per endpoint via a new CachedChannelCount.
The_known_cluster_set_is_not_published_by_the_other_two_modes is
replaced — its premise is obsolete — by three facts: every mode
publishes, gate set is a strict superset of the fan set, and the handler
ordering.
ControlPlane.Tests 230 -> 236, Host.Tests 92, Cluster.Tests 184,
0 warnings.
MeshGrpcCommandDialer places one NodeCommandService.Execute call on one
node: a GrpcChannel cached per endpoint (the GrpcDeploymentArtifactFetcher
shape), the TARGET node's cluster's bearer plus x-otopcua-cluster naming
that cluster, and a per-call deadline linked to the caller's token. A
cluster with no resolvable key is refused locally with Unauthenticated —
there is no arm on which a command leaves central unauthenticated, even
one the far side would have rejected.
CentralCommunicationActor gains the third mode branch. The contact load
now also projects GrpcPort and, from the SAME rows in the SAME pass,
builds the dispatch set — which is what makes 'the gRPC fan reaches
exactly the SendToAll recipient set' structural rather than two queries
that have to keep agreeing. A row with a null GrpcPort is skipped
warn-once (the TelemetryNodeSource precedent). Per-node results are
piped back for LOGGING ONLY: named node, gRPC status, dropped. No retry,
no queue.
Every dial is scheduled on the thread pool rather than called from the
receive. Found by review and pinned red-first: an async method runs
synchronously to its first await, and the dialer's pre-await work is
TryGetPsk, which blocks on the secret store — bounded but seconds, and
repeated after every refresh since the refresh drops the cache. Dialing
inline parked the actor's mailbox, so deployment acks queued behind a
slow node; the regression test tells an ApplyAck while a dial is held
and fails without the hop.
The contact refresh also wires the Phase 1A register: it publishes the
loaded cluster ids as the PSK provider's known-cluster set and drops the
key cache, so a rotated key takes effect within one ContactRefreshSeconds.
Neither happens under Dps or ClusterClient.
Both existing mode branches are behaviourally untouched and every
existing fact passes unmodified. The one edit to shared text: the
Status.Failure warning drops the word 'ClusterClient', since that handler
now serves all three transports.
ControlPlane.Tests 205 -> 230, Host.Tests 92, Cluster.Tests 184, 0 warnings.
Phase 1A security register items 1 and 2, landed ahead of the command
fan-out because they are independently testable and the fan-out is the
first caller of TryGetPsk.
Item 1 — known-cluster gate. MeshPskProvider gains SetKnownClusters, an
atomic whole-set swap consulted by TryGetPsk BEFORE the config map and
before the secret store. A cluster id outside the set is refused in O(1)
with no store read and no audit write, which closes two things at once:
the pre-auth store/audit flood an unauthenticated caller could drive with
a forged x-otopcua-cluster header, and the timing oracle that defeated
CentralCommandAuthInterceptor's uniform denial text (unknown clusters are
never cached, so they paid a store read on every probe while known ones
answered from memory). Empty or never-published leaves the gate inactive
— central publishes the set from its DB contact refresh, and 'the DB told
me nothing' must not become a fleet-wide authentication outage during
admin boot.
Item 2 — bool Matches(clusterId, presented) on IMeshPskProvider, with
FixedTimeEquals inside the provider. CentralCommandAuthInterceptor now
calls it and never holds key material; its two provider-side denial logs
collapse into one (the provider answers both as false) and the operator
hint is restated there.
No production caller publishes a cluster set yet, so behaviour is
unchanged until the fan-out commit wires the contact refresh.
ControlPlane.Tests 190 -> 205, Host.Tests 91 -> 92.
Found on the docker-dev live gate, not in tests. Two drivers that faulted
during initialise (rtu-gate, opcua1) each rendered "0 tags" on /hosts against
two authored tags apiece, because a ledger that had never committed returned
SkippedTagReport.Empty.
A zero report is a positive claim -- "this driver skipped nothing" -- and
making it on behalf of a driver that never got as far as looking is exactly
the quiet inaccuracy #541 exists to remove. GetSkippedTags() and
SkippedTagLedger.Snapshot() now return null until the first committed build,
so the column renders the same em-dash it already used for a driver that
cannot report at all. Both are 'no answer'; neither is 'nothing skipped'.
Knock-on: a FOCAS driver whose only init threw now reports null rather than a
zero report, which is strictly more honest than the assertion the test
originally made.
A driver builds its RawPath -> definition table at init and tolerates a
per-tag miss: an unmappable TagConfig, an unparseable address, a
capability-matrix rejection. That tolerance is right -- one bad tag must not
take down the other few thousand. What was missing is any statement of the
fact afterwards. A skip is not an error and happens before any read, so the
driver stays Healthy, errors/5 min stays 0, Last error stays empty, and Last
read advances live off the tags that did map. On the wonder Makino in #540
that reading held while focas-z-34184 ignored 20 of its 22 tags.
New optional capability ISkippedTagReporter, backed by a shared
SkippedTagLedger so the reset/commit/cap rules are one implementation rather
than one per driver. The report -- authored count, exact skipped count, and a
capped sample of RawPath + reason -- rides DriverHealthChanged to a new Tags
column on /hosts, over the Phase 5 telemetry stream. No table: a driver-only
node has no ConfigDb to write to, the lesson from #521.
The issue named eight drivers. It is twelve -- every driver in
DriverTypeNames.All has an authored-tag skip path. Calculation (no scriptId),
MTConnect (no readable DataItem id), Galaxy (no attributeRef) and OpcUaClient
(no nodeId) were unlisted, and OpcUaClient's was the quietest of the twelve:
NamespaceMap drops such an entry with a bare `continue` and not even a log
line. SkippedTagReporterFleetTests pins the invariant reflectively over every
IDriver in src/Drivers/, so a thirteenth cannot re-introduce the silence.
Sql drops a tag at TWO points and its report is the union of both: a blob
that does not map, AND an identifier the 8.1 catalog gate rejects against the
live catalog. The second is what schema drift produces -- a renamed column, a
dropped view -- months after a deployment sealed green, and reporting only
the first would have that driver claim "0 skipped" while polling half its
tags, which is worse than reporting nothing because the column would then be
actively reassuring.
Deliberately additive to driver state, never a change of it. Latching
non-Healthy for a config problem would satisfy both halves of the #527
comms-loss conjunction -- 90 s without a successful read AND non-Healthy --
and a driver whose tags were ALL skipped has no successful reads by
construction, so it would reconnect-loop forever against a healthy device.
Three details that are load-bearing rather than incidental:
- The skip digest is part of the publish fingerprint. A skipped tag leaves
every other fingerprint component identical to a clean driver's, so without
it PublishHealthSnapshot's dedup swallows exactly the publish carrying the
signal -- the trap that already bit the rediscovery and host-status
channels. The digest covers the sample, not just the counts: a redeploy
that fixes one tag and breaks another leaves both counts unchanged.
- The count is exact; only the sample is capped, and the tooltip says so when
it is showing fewer than it counted. A truncated list that looked complete
would have an operator fix twenty tags and believe the job done.
- The ledger stages and commits, so an init that throws part-way leaves the
previous report standing. A partial snapshot would read as "we now skip
fewer tags", the opposite of the truth.
The proto field needs no companion presence flag, unlike host_statuses: a
singular message field carries real presence in proto3, and a has_ flag would
collide with protoc's generated HasSkippedTags.
Verified red-first three ways: dropping SkippedTagDigest from the fingerprint
fails the two dedup tests, removing the seam from one driver fails the fleet
guard, and dropping the catalog-gate leg fails the Sql union test. Full
solution builds with zero new warnings against 4e22f024.
Authoring FOCAS tags through /raw -> Browse device... produced tags the driver
could never read. Every committed tag read BadNodeIdUnknown forever, and the
failure was silent end to end: the AdminUI accepted it, the deploy gate sealed
green, and the driver reported Healthy with 0 errors while ignoring the tags.
Net effect: the whole fixed-tree surface could not be published through any v3
authoring path. Found cutting wonder-app-vd03 over to v3 against a real Makino
Pro 5 / Fanuc 30i, where 0 of 20 committed tags read while two hand-authored
MACRO: tags on the same device read Good.
A captured browse leaf's id IS its DriverAttributeInfo.FullName, and the fixed
tree emitted "{deviceHost}/{path}" there -- an internal cache key, not an
address. Both authoring paths wrote it verbatim into TagConfig.address, and
FocasAddress.TryParse accepts no such form, so the driver skipped the tags at
init.
Fixed at the emitter rather than by stripping the host at commit, which fixes
the browse-commit flow and the manual picker's tree-select together and leaves
one canonical address form:
- FocasAddress gains a fourth kind, FIXED:<path>, and moves to Contracts so the
AdminUI and ControlPlane can parse without referencing the runtime driver
(#526). A FIXED: read is served from the fixed-tree snapshot the poll loop
already maintains -- no area read, no connection. Writes refuse: nothing in
that tree is a writable location on the CNC.
- The address carries no device. A tag's device comes from its Device row, and
a second routing channel for one fact is what created this defect.
- An authored FIXED: tag arms the fixed-tree poll loop by itself. Enabled
defaults false and the browser force-enables it only for a browse, so the
operator would otherwise browse, commit, deploy, and land on a driver whose
loop never starts -- every tag Bad with a correct address.
- Fixed-tree values are now dated from the last answered poll and go
BadCommunicationError once it is stale (8 cadences, floored at 30s). The poll
loop swallows a failed tick by design, so a dead CNC would otherwise serve its
last snapshot as Good indefinitely -- harmless while nothing could bind to the
tree, not harmless now.
Guardrails, so this class cannot recur silently:
- FocasTagConfigModel.Validate() runs the real parser instead of a non-empty
check, and FocasTagDefinitionFactory.Inspect() warns at the deploy gate, which
covers CSV/API config that never touches the modal.
- The manual picker offered axis/spindle/program/status "parameter groups" --
none of which is a FOCAS addressing space -- and its own default value,
axis:5, was unusable. It now composes PMC / PARAM: / MACRO: through
FocasAddress, so what it emits is parseable by construction.
Tests assert addresses ROUND-TRIP through the parser rather than matching an
expected string: the previous FocasAddressBuilderTests pinned "axis:5" exactly,
which is how a green suite coexisted with a picker nobody could use. Verified
red-first against the old emitter. FOCAS 308, AdminUI 1095, ControlPlane 169,
Core 581 -- all pass, 0 warnings.
The remaining half of #540 -- a driver reporting Healthy/0 errors while
skipping tags at init -- is fleet-wide (eight drivers do this) and is filed
separately rather than patched per-driver.
SqlDriverProbe.DefaultDialectFor was left SqlServer-only when the provider
gates were widened, so AdminUI Test Connect failed for both new providers
with InvalidOperationException while Deploy and browse worked. Found by the
live chrome/AdminUI gate the plan deferred, not by any test: every case in
SqlDriverProbeTests builds its probe through ForTest(), which injects the
dialect and never reaches the production switch.
Widen the switch arm-for-arm with SqlDriverFactoryExtensions.CreateDialect,
and cover the gate directly via an internal seam — plus a reserved-provider
falsification control and an end-to-end production-constructor case.