test(opcuaclient,mtconnect): live-fixture cases for the lane G1 fixes
Against opc-plc (opc.tcp://10.100.0.35:50000): a shutdown with three live subscriptions is bounded and the same instance re-initialises and reads (O-9 + lifecycle generation through the real SDK); a server-refused write (BadTypeMismatch) passes through and keeps the driver Healthy with its stamp advanced (health contract); the browse side-panel reports a live variable's type, shape and access (O-5). Against the MTConnect fixture Agent: the headers-only ping reaches it and fails on a dead port (T-7); a delivering /sample stream serves reads and reports its lag and effective count on the diagnostics bag (T-4/T-5). Refs #743 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
+57
@@ -92,4 +92,61 @@ public sealed class OpcUaClientSmokeTests(OpcPlcFixture sim)
|
||||
|
||||
await drv.UnsubscribeAsync(handle, TestContext.Current.CancellationToken);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Review 2026-10-21 O-9 + lifecycle generation, through the real SDK: a shutdown with several live
|
||||
/// subscriptions completes inside the one teardown budget, lands Unknown, and a re-initialise of the same
|
||||
/// instance reconnects and reads.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task Shutdown_with_live_subscriptions_is_bounded_and_the_instance_reinitialises()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
var ct = TestContext.Current.CancellationToken;
|
||||
|
||||
var options = OpcPlcProfile.BuildOptions(sim.EndpointUrl);
|
||||
await using var drv = new OpcUaClientDriver(options, driverInstanceId: "opcua-smoke-lifecycle");
|
||||
await drv.InitializeAsync("{}", ct);
|
||||
for (var i = 0; i < 3; i++)
|
||||
await drv.SubscribeAsync([OpcPlcProfile.FastUInt1Ref], TimeSpan.FromMilliseconds(250), ct);
|
||||
|
||||
var sw = System.Diagnostics.Stopwatch.StartNew();
|
||||
await drv.ShutdownAsync(ct);
|
||||
sw.Stop();
|
||||
|
||||
sw.Elapsed.ShouldBeLessThan(TimeSpan.FromSeconds(10), "one 4 s budget bounds the whole teardown");
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Unknown);
|
||||
|
||||
await drv.InitializeAsync("{}", ct);
|
||||
var read = await drv.ReadAsync([OpcPlcProfile.StepUpRef], ct);
|
||||
read.Single().StatusCode.ShouldBe(0u, "the re-initialised instance must be fully usable");
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Healthy);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The health contract against a real server: a write the server REFUSES (a string into the UInt32 StepUp —
|
||||
/// BadTypeMismatch) is a reply — the refusal status passes through and the driver stays Healthy with its stamp
|
||||
/// advanced.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task A_server_refused_write_is_a_reply_and_keeps_the_driver_healthy()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
var ct = TestContext.Current.CancellationToken;
|
||||
|
||||
var options = OpcPlcProfile.BuildOptions(sim.EndpointUrl);
|
||||
await using var drv = new OpcUaClientDriver(options, driverInstanceId: "opcua-smoke-refused-write");
|
||||
await drv.InitializeAsync("{}", ct);
|
||||
var before = drv.GetHealth().LastSuccessfulRead.ShouldNotBeNull();
|
||||
var deadline = DateTime.UtcNow + TimeSpan.FromSeconds(5);
|
||||
while (DateTime.UtcNow <= before && DateTime.UtcNow < deadline) await Task.Yield();
|
||||
|
||||
var result = await drv.WriteAsync([new WriteRequest(OpcPlcProfile.StepUpRef, "not-a-number")], ct);
|
||||
|
||||
(result.Single().StatusCode & 0x80000000u).ShouldNotBe(0u, "opc-plc refuses a string written into a UInt32");
|
||||
result.Single().StatusCode.ShouldNotBe(0x80050000u, "a server refusal is not a local comms error");
|
||||
var h = drv.GetHealth();
|
||||
h.State.ShouldBe(DriverState.Healthy);
|
||||
h.LastSuccessfulRead.ShouldNotBeNull().ShouldBeGreaterThan(before);
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue